Faber 630002752 User Manual

Inca HC SS
the high powered hideaway
high capacity insert
°
for custom cabinets and hoods
°
stainless steel finish
°
540 cfm
°
2 halogen lights
°
3 speed control
°
dishwasher safe grease filters
°
convertible to recirculating
°
BUILT-IN
standard SERIES
top or direct rear venting
°
built-in mounting system
°
sone range: 3.5 - 6.5
°
6” round duct
°
Size/Color/Model # 29 Stainless
Inca HC can be used with custom cabinetry
a
and hoods 30" wide and up. Choose either
c
a custom liner or our Standard Liner in
c
standard 30" and 36" widths.
e s
Liners
s
Create a perfectly-sealed, non-combustible
o
perimeter around the Inca HC SS. Depth adjustable from 18” - 21 1/2”.
r
i
Standard Liner 30 Stainless
e
Standard Liner 36 Stainless
s
630002752
620000304 620000305
The Inca HC (high capacity) power pack is perfect for the homeowner who needs powerful ventilation, but does not want to see a rangehood at all. This exceptionally finished power pack installs effortlessly into your custom cabinet or hood.
Charcoal Filters 6093034
For recirculating installations, high quality, heavy duty filters ensure the removal of smoke and odors from the kitchen. Some ductwork is required to exhaust the unit out of the cabinet.
p.o. box 435 • Wayland, MA 01778 • tel: (508) 358-5353 • fax: (508) 358-5730 • e-mail: info@faberonline.com • www.faberonline.com
Dimensional Diagrams
0
Front View
Note: The Inca HC comes standard in the top vent position. The direct rear vent position can be achieved by rotating the blower housing.
Cut-Out
Side View
Bottom View
Pre-Planning Your Ductwork -
Make your ductrun as straight and short as possible. The ductrun should not exceed 35 equivalent feet if ducted with the required minimum of 6" round duct.
Important: Consult the installation instructions before you begin installing this rangehood.
Recirculating Installations
For installations where ductwork is impossible or highly impractical Charcoal Filters, which attach to the blower assembly, absorb smoke and odors.
Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.
ceiling
soffit
vent grate
ceiling
For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away , do it as far away from the hood's exhaust opening as possible.
cabinet
23456789
6” round
duct
vent grate
cabinet
6” round
duct
For more efficient airflow when venting to the rear: Rotate the Inca HC blower housing so that the 6”
hood
round exhaust outlet faces the back, rather than running ductwork up and elbowing back.
WARNING! Product specifications are subject to change without notification. Consult the installation instructions before
Some ductwork must be installed
to exhaust the rangehood back into the kitchen, either at the top of the cabinet or at the face of the soffit. A plastic vent grate supplied with the rangehood can be used to cover the duct opening. This duct work must not terminate into a dead air space.
Rev.05/04