Inca HC SS
the high powered hideaway
high capacity insert
°
for custom cabinets and hoods
°
stainless steel finish
°
540 cfm
°
2 halogen lights
°
3 speed control
°
dishwasher safe grease filters
°
convertible to recirculating
°
BUILT-IN
standard SERIES
top or direct rear venting
°
built-in mounting system
°
sone range: 3.5 - 6.5
°
6” round duct
°
Size/Color/Model #
29 Stainless
Inca HC can be used with custom cabinetry
a
and hoods 30" wide and up. Choose either
c
a custom liner or our Standard Liner in
c
standard 30" and 36" widths.
e
s
Liners
s
Create a perfectly-sealed, non-combustible
o
perimeter around the Inca HC SS. Depth
adjustable from 18” - 21 1/2”.
r
i
Standard Liner 30 Stainless
e
Standard Liner 36 Stainless
s
630002752
620000304
620000305
The Inca HC (high capacity) power pack is perfect for the
homeowner who needs powerful ventilation, but does not want
to see a rangehood at all. This exceptionally finished power
pack installs effortlessly into your custom cabinet or hood.
Charcoal Filters 6093034
For recirculating installations, high
quality, heavy duty filters ensure the
removal of smoke and odors from the
kitchen. Some ductwork is required
to exhaust the unit out of the cabinet.
p.o. box 435 • Wayland, MA 01778 • tel: (508) 358-5353 • fax: (508) 358-5730 • e-mail: info@faberonline.com • www.faberonline.com
Dimensional Diagrams
Front View
Note: The Inca HC comes standard in the
top vent position. The direct rear vent
position can be achieved by rotating the
blower housing.
Cut-Out
Side View
Bottom View
Pre-Planning Your Ductwork -
Make your ductrun as straight and short
as possible. The ductrun should not
exceed 35 equivalent feet if ducted with
the required minimum of 6" round duct.
Important: Consult the installation instructions before you begin installing this rangehood.
Recirculating Installations
For installations where ductwork is impossible or highly impractical Charcoal Filters, which
attach to the blower assembly, absorb smoke and odors.
Count 45º angles as 3 feet, 90º elbows
as 5 feet, and 90º flat elbows as 12 feet.
ceiling
soffit
vent grate
ceiling
For best results, use no more than
three 90° elbows. Make sure that
there is a minimum of 24" of straight
duct between elbows if more than
one is used. Do not install two
elbows together. If you must elbow
right away , do it as far away from the
hood's exhaust opening as possible.
cabinet
23456789
6” round
duct
vent grate
cabinet
6” round
duct
For more efficient airflow when
venting to the rear: Rotate the Inca
HC blower housing so that the 6”
hood
round exhaust outlet faces the back,
rather than running ductwork up and
elbowing back.
WARNING! Product specifications are subject to change without notification. Consult the installation instructions before
Some ductwork must
be installed
to exhaust
the rangehood back into
the kitchen, either at the
top of the cabinet or at the
face of the soffit. A plastic
vent grate supplied with
the rangehood can be
used to cover the duct
opening. This duct work
must not terminate into a
dead air space.
Rev.05/04
you begin installing this rangehood.