Faber 630001088, 630001648, 630001087 User Manual

Diamante
a brilliantly cut gem
wall canopy rangehood
°
sleek styling
°
600 cfm PRO motor
°
Silent Kit noise reduction
°
2 halogen lights for 30”
°
3 halogen lights for 36” and 48”
°
3 speed push button controls
°
stainless steel baffle filters
°
°
convertible to ductless*
°
Easy Cube mounting system
°
sone range: 3.5 - 6.5
°
Designer Collection
6” round duct
°
* it is highly recommended that professional style cooking always be vented to the outside.
A streamlined shape combined with traditional styling makes the Diamante an updated alternative in canopy ventilation. To add subtle sparkle, the corners of the canopy and the chimney are angled in a diamond-like cut.
Size/Color/Model #
30 Stainless 36 Stainless 48 Stainless
a
24” High Backsplash
24” high, mounts to the wall beneath
c
the rangehood for a coordinated look
c
30 x 24 Stainless 36 x 24 Stainless
e s
30” High Backsplash
30” high, mounts to the wall beneath
s
the rangehood for a coordinated look
o
30 x 30 Stainless 36 x 30 Stainless
r
High Ceiling Chimney Kit
i
One 40” upper chimney to replace 16 1/8”
e
upper chimney that came with hood
s
Stainless 620000071
p.o. box 435 • Wayland, MA 01778 • tel: (508) 358-5353 • fax: (508) 358-5730 • e-mail: info@faberonline.com • www.faberonline.com
630001087 630001088 630001648
6098835 6098815
620000095 620000096
pro-style baffle filters with European flair and a built-in grease control system; bright halogen lights encircled by a stainless trim
Ductless Conversion Kit
Includes: • Lower Chimney with holes for duct­ing • Ductless Diverter Assembly • Vent Grates
• Charcoal Filter
Stainless
Replacement Charcoal Filter
620000072
620000041
upper
chimney
cover
ductless lower
chimney
cover
canopy
x = distance from hoo d to cooktop
(varies depending on installation) min - 24”, suggested max - 30”
cabinet base
10" min
16
1/8”
max
22"
3
3/8”
36”
22"
x
also consult co oktop
manufacturer's recommendation
min & max ceiling height examples
x = 30"
min
8'
5 3/8"
max
8'
11 1/2"
x = 28"
min
8'
3 3/8"
max
8'
9 1/2"
x = 26"
min
8'
1 3/8"
max
8'
7 1/2"
x = 24"
min
7'
11 3/8"
max
8'
5 1/2"
Dimensional Diagrams
upper
chimney
cover
lower
chimney
cover
canopy
x = distance from hoo d to cooktop
(varies depending on installation) min - 24”, suggested max - 30”
cabinet base
5
1/8” min
16
1/8” max
21
1/4”
3 3/8”
36”
22"
x
also consult co oktop
manufacturer's recommendation
min & max ceiling height examples
x = 30"
min
7'
11 3/4"
max
8'
10 3/4"
x = 28"
min
7'
9 3/4"
max
8'
8 3/4"
x = 26"
min
7'
7 3/4"
max
8'
6 3/4"
x = 24"
min
7'
5 3/4"
max
8'
4 3/4"
Ducted
Ductless
Pre-Planning Your Installation - Important: Consult the installation instructions before you begin installing this rangehood.
Ducted
For ducted installations, the
chimneys can be adjusted for ceilings between 7’ 5 3/4” and 8’ 10 3/4” depending on the distance between the bottom of the hood and the cooktop (distance x in Ducted diagram).
For ductless installations, the
chimneys can be adjusted for ceilings between 7’ 11 3/8” and 8’ 11 1/2” depending on the distance between the bottom of the hood and the cooktop (distance x in Ductless diagram).
For shorter ceilings, have the chimney cover(s) cut at a sheet metal shop. For
higher ceiling installations,
Note: If 24” or 30” High Backsplash is being installed, the distance between the bottom of the hood and the cooktop (distance x in
diagram) is equal to the height of the Backsplash.
Pre-Planning Your Installation - Important: Consult the installation
instructions before you begin installing this rangehood.
Make your ductrun as straight and short as possible. The ductrun should not exceed 35 equivalent feet if ducted with the required minimum of 6” round duct. Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º at elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24” of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood’s exhaust opening as possible.
WARNING! Product specifications are subject to change without notification. Consult the installation instructions before you begin installing this rangehood.
the High Ceiling Chimney Kit includes a new 40”
upper chimney which would replace the 16 1/8” upper chimney that came with the hood.
Ductless Installations*
For installations where ductwork is impos­sible or highly impractical, a Ductless Conversion Kit is available. A charcoal filter, which attaches under the blower assembly, absorbs smoke and odors. A ductless diverter assembly directs the air out to a lower chimney with vent grates cut into the sides.
* it is highly recommended that professional style cooking always be vented to the outside.
Ductless
Rev. 06/08