FAAC XBFA ON User Manual

g
859
/
06
3
LED-SIGNALS
S
The ORANGE LED fl ashes quickly.
The ORANGE LED fl ashes 1 x.
1
The ORANGE LED fl ashes 2 x.
2
The ORANGE LED fl ashes 4 x.
4
The ORANGE LED fl ashes 5 x.
5
The ORANGE LED is on.
The RED LED fl ashes quickly after an assisted setup.
The RED LED lights up sporadically.
PLEA SE KEEP FOR F URTHER U SE - DESIGNED FOR COLOU R PRINTING
The LED is off.
The reaction of
.1
V1
.7
instructions ina
ri
BEA
Manufactured by: BE A SA - LIEGE Science Park - Allée d es Noisetiers 5 - 4 031 Angleur - Belgium - T +32 4 3616565 - F +32 4 3612858 - info@bea.be - www.bea.be
the door does not correspond to the LED-signal.
FAAC S.p.A . - Via Calari, 10 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com
BEA hereby declares that the FAAC XBFA ON is in conformity with the basic requirements and the other relevant provisions of the directives 2004/108/EC and 2006/42/EC. Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen Angleur, June 2013 Pierre Gardier, Authorized representative and responsible for technical documentation
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)
A DIP-switch was changed without confi rmation.
The sensor signals an internal fault.
Irregularities in the power supply
The sensor receives not enough IR-energy.
The sensor receives too much IR-energy.
The sensor encounters a memory problem.
The sensor sees the door during the assisted setup.
The sensor vibrates.
The sensor sees the door.
The sensor is disturbed by lamps or another sensor.
The sensor is disturbed by the rain.
1
Confi rm the DIP-settings by a long push on the push button.
Cut and restore power supply.
1
If orange LED fl ashes again, replace sensor.
2
1
Check power supply. Check wiring.
2
Use the 1 m prism if possible (accessory).
1
Check the angle of the IR-curtains.
2
Use a low energy prism if possible (accessory).
1
Check the angle of the IR-curtains.
2
Cut and restore power supply.
1
If orange LED lights up again, replace sensor.
2
1
Check the angle of the IR-curtains. Launch a new assisted setup.
2
Attention: Do not stand in the detection fi eld!
Check if the sensor is fastened fi rmly.
1
Check position of prism and cover.
2 1
Launch an assisted setup and adjust the IR angle.
1
Choose a different frequency (DIP 2).
1
Choose the critical environment presetting (DIP 1).
Check connections to test output.
1
If your door controller is not able to test the sensor,
2
connect the red and blue cable to the power supply.*
Change the output confi guration (DIP 4).
1
*excludes EN 16005-conformity of the door system
User’s Guide for product version 0100 and higher See product label for serial number
DESCRIPTION
1
2
1. cover
2. IR-prism (2 m)
3. main connector
TECHNICAL SPECIFICATIONS
Supply voltage: Power consumption: Mounting height: Sensitivity of the test input: Temperature range: Degree of protection: Noise: Expected lifetime: Norm conformity:
Detection mode:
Technology:
Angle: Output:
Hold time output signal: Response time on test request:
12 V - 30 V DC -5%/+10% (to be operated from SELV compatible power supplies only) < 1.6 W
1.8 m to 3 m < 1 V : Log. L; > 10 V: Log. H (max. 30 V)
-25 °C to +55 °C IP54 < 70 dB 20 years MD 2006/42/EC; ROHS 2 2011/65/EU; EN 16005:2012; EN 12978:2009;
EN IEC 62061:2005 SIL2; EN 61496-1:2012 ESPE Type 2; EN ISO 13849-1:2008 Pl «c»
(under the condition that the door control system monitors the sensor at least once per door cycle)
Presence Typical response time: <256 ms Active infrared with background analysis Spot diameter: 0.1 m (typ) Number of spots: 24 Number of curtains: 2 From -4 ° to +4 ° (adjustable) Solid-state-relay (free of potential, free of polarity) Max. contact current: 100 mA Max. contact voltage: 42 V AC/DC
0.3 s to 1 s (not adjustable) Typical: < 5 ms
XBFA ON
Safety sensor for automatic sliding doors
4. IR-angle adjustment
5. push button for setup or DIP-setting confi rmation
6. DIP-switch
RED LED
pecifi cation s are subjec t to changes without pri or notice. All values measured in specifi c conditions.
ENGLISH
3 4
5
6
CAT.2
0
1
0
MOUNTING & WIRING
CLOSER
AWAY
1
SETTINGS (by DIP-switch)
3
max. 5 cm
The door control unit and the door cover profi le must be correctly earthed.
INFRARED FIELD - SAFETY
2
W
1
2 m
H
2
1
0
H W
2.20 m 2.30 m
2.50 m 2.55 m
3.00 m 2.80 m
WIDTH
0
1
2
Detection fi eld width indicate d according to conditions defi ned in EN 16005 and including dimension of test bo dy CA.
2
3
3
12-30 V DC
RELAY R1
RELAY R2
GREEN
BROWN
YELLOW
1
1
WHITE
SENSOR
PINK
GREY
2
RED
2
BLUE
1
Output status when sensor is operational
2
For compliance with EN 16005, connection
to door controller test output is required.
+
POWER SUPPLY
-
OPENING INPUT
SAFETY INPUT
+
TEST OUTPUT
-
PRESETTINGS
critical
environment
standard
1
Enhanced IR-immunity which excludes EN 16005-conformity of the door. system.
B
A
standard: standard environments (factory setting)
critical environment: enhanced immunity for critical environments (rain, snow, lamps...). Only 1 IR-curtain activated.
ENVIRONMENT R2 CONFIGURATIONFREQUENCY
extreme
standard
1
NO
NC
After changing a DIP-switch, the orange LED fl ashes.
RED LED
H
0
1
2
3
W
2
1
0
1
2
3
H W
1 m
2.20 m 1.20 m
2.50 m 1.40 m
3.00 m 1.60 m
Available as accessory
«click»
+
SETUP
4
QUICK SETUP
ORANGE OFF
LONG (> 3s)
Step outside of the detection fi eld before launching a setup.
OFF
RED-GREEN
SHORT
A LONG push on the push button confi rms the setting.
Always launch a setup after changes of the DIP-settings.
ASSISTED SETUP
+
OPEN+CLOSE
LONG
LONG (> 3s)
The yellow and white wires have to be connected to launch an assisted setup.
RED-GREEN
OFF
Launch an ASSISTED SETUP to verify wiring, position of the curtains and correct functioning of the sensor.
Check position of IR-curtains with Spotfi nder and adjust if necessary.
max.
ANGLE
5 cm
DOOR
ORANGE
Depth of curtain: 8-10 cm Depth of safety fi eld: 25 cm*
* in standard presetting
The size of the detection fi eld varies according to the m ounting height of the sensor.
CLOSER
AWAY
SAFETY INSTRUCTIONS
- Test the good functioning of the installation before leaving the premises.
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of the sensor.
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
- Only trained and qualifi ed personnel may install and setup the sensor.
- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel.
- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to neon lamps or moving objects.
- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.
Loading...