FAAC SD-6276-SS1Q User Manual

Slimline plate, “TOUCH/EXIT”
Slimline plate, “EXIT/SALIDA”
Slimeline plate, manual override
Single-gang plate, “TOUCH/EXIT”
Single-gang plate, “EXIT/SALIDA”
Single-gang plate, manual override
Piezoelectric push buttons for indoor
or outdoor use (IP65).
LED ring around button changes from
green to red or red to green when the button is pressed.
Timed or toggle output.
Includes separate manual override
button in case power to piezoelectric push button fails.
Relay rated 2A@30VDC with two
individually programmable outputs (NO/NC).
Note: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHS compliant.
Outdoor Piezoelectric
Request-to-Exit Pushbuttons
Manual
ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton
Operating voltage
12~24 VDC
Current drain 100mA@12VDC
Contact rating
2A@30VDC or 0.5A@125VAC
Ring LED
Colors reversible v a switch
Standby
Red
Active
Green
Output time
1~30 s, Toggle
IP rating
IP65
Operating temperature
32 ~158 F (0 ~70 C)
Plate material
Stainless steel
Weight
Single-Gang
3.5-oz (99g)
Single-Gang w/Manual
Override
4-oz (113g)
Slimline
2.6-oz (74g)
Slimline w/Manual
Override
3.1-oz (88g)
Single-Gang
Slimline
41/2”
(114mm)
LED ring
Manual override button2
Piezo­electric pushbutton
15/8” (42mm)
23/4” (70mm)
15/8” (42mm)
Side View
Rear View
(Plastic switch
cover removed)
Relay adjust
Output mode selection
Terminal blocks
Manual override button2
Buzzer adjust
LED color selection
Timer adjustment
Terminal Block
Specifications:
Parts List:
Piezoelectric push button ........................... 1 x Mounting screws .................................. 2 x
Wires for manual override 1 ........................ 2 x Manual ................................................. 1 x
Overview:
SD-6176-SSVQ and SD-6276-SSVQ with Manual Override button shown, other models similar.
Installation:
1. Prepare wiring to provide 12~24 VDC power and connect devices to the relay outputs.
Note: The device includes one relay with two outputs. Outputs trigger simultaneously but can be configured independently. To set the output modes, see Relay Output Modes on page 3.
2. Remove the plastic cover from the rear of the switch and carefully pierce the rubber grommet.
3. SD-6176-SSVQ and SD-6276-SSVQ: Wire the manual override button. See page 3.
4. Wire the switch according to the diagram on the right.
Connect (-) and (+) to a 12~24 VDC power source. Connect other devices to Outputs 1 or 2.
5. Replace the plastic switch cover and screw the plate
onto the mounting surface.
1
SD-6176-SSVQ and SD-6276-SSVQ only.
2 SECO-LARM U.S.A., Inc
Loading...