FAAC 1815-051 User Manual

Weigand Keypad Installation and Programming
These instructions apply to the following DoorKing Digital Keypads: 1815-050, 1815-051, 1815-052, 1838-120, 1504-120. When used to control entry through an automated vehicular gate system, the
keypad must be mounted a minimum of 10-feet away from the gate and gate operator, or mounted in such a way that the person using the keypad cannot come into contact with the gate or gate operator.
WIRING Use Belden 9418 or 9931 for wiring.
TERM 1 Input power 12-24 volt AC or DC NEGATIVE / WEIGAND COMMON (BLACK) TERM 2 Input power 12-24 volt AC or DC POSITIVE (RED) TERM 3 Earth Ground TERM 4 Weigand COMMON TERM 5 Not Used TERM 6 Weigand DATA 0 (GREEN) TERM 7 Weigand DATA 1 (WHITE) TERM 8 Not Used
1815-064-F-8-12
Master Code
12345678
White
Red
Black
Green
Belden 9418
LED
Lights
Gray
12-24 Volt
Orange White - DATA 1
Green - DATA 0 Red - POWER Black - COMMON
AC or DC
To Access
Controller

PROGRAMMING

MASTER CODE
1. Press the master code button on the circuit board once.
2. Enter a four-digit code _ _ _ _ then press * (beep).
FACILITY CODE
1. Press * 4 and the four-digit master code _ _ _ _ (beep).
2. Enter a three-digit facility code _ _ _ (000-255) then press * (beep).
3. Press 0 # together to end the programming (beeeeeep).
4. NOTE: If facility codes are not used, skip this step.
ENTRY CODE BOUNDARIES
Entry codes between the boundary limits will weigand out to the controller. Entry codes outside the boundary limits will not weigand out. Set the boundary limits so that the entry codes do not duplicate any card or transmitter codes that are programmed into the controller. For example, if transmitter codes 01000 through 02000, and card codes 06000 through07000 are already being used and programmed into the access controller, you could set the lower boundary to 03000 and the upper boundary to 05000. This prevents a five-digit entry code from accidentally duplicating a card or transmitter code.
FIVE DIGIT BOUNDARIES
1. Press * 5 and enter the four-digit master code _ _ _ _ (beep).
2. Enter a five-digit lower boundary _ _ _ _ _ then press * (beep).
3. Enter a five-digit upper boundary _ _ _ _ _ then press * (beep). (To remove five-digit boundaries, enter 0 0 0 0 0 in step 2, and 65405 in step 3.)
4. Press 0 # together to end the programming (beeeeeep).
FOUR DIGIT ENTRY CODE (USING THE # KEY) BOUNDARIES
This programming sequence allows a 5-digit weigand code to mimic 4-digit entry codes programmed into the telephone entry system. For example, to open the gate from the telephone entry system keypad, the tenant presses “#-1-2-3-4” (or whatever the 4-digit code is). Using this feature, the tenant would still enter “#-1-2-3-4” on the weigand keypad to open the gate. The # automatically defaults to “0”, so if “#-1-2-3-4” is entered on the keypad, the 5-digit code “0-1-2-3-4” is actually sent to the controller. The gate will open provided that the 5-digit weigand code “0-1-2-3-4” is programmed as a device code.
Use the programming sequence below to set the lower and upper boundary limits of the 4-digit entry codes that will open the gate. To allow ALL four-digit entry codes to be valid, enter 0 0 0 0 in step 2, and 9 9 9 9 in step 3. To disable the four-digit code feature, enter # # # # in step 2, and # # # # in step 3.
1. Press * 8 and enter the four-digit master code _ _ _ _ (beep).
2. Enter a four-digit lower boundary _ _ _ _ then press * (beep).
3. Enter a four-digit upper boundary _ _ _ _ then press * (beep).
4. Press 0 # together to end the programming (beeeeeep).