Series
XPA 1002, XPA 1002 Plus
XPA 1002-70V, XPA 1002-100V
XPA 2001-70V, XPA 2001-100V
Half-Rack Audio Power Amplifiers
User Guide
Audio Products
68-2354-01 Rev. B
04 16
Safety Instructions
Safety Instructions • English
WARNING:This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website,
www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website,
www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron,
www.extron.com.
Istruzioni di sicurezza • Italiano
AVVISO: Questo simbolo, ,quando viene utilizzato il prodotto, serve
ad avvisare l’utente della presenza di tensioni pericolose non isolate
all’interno del prodotto, che può presentare un rischio di scosse
elettriche.
ATTENTZIONE: Questo simbolo, , quando viene utilizzato il
prodotto, serve ad avvisare l’utente di importanti istruzioni di uso e
manutenzione (assistenza) nella letteratura fornita con l’apparecchiatura.
Per informazioni sulle linee guida di sicurezza, adempimenti normativi,
compatibilità EMI/EMF, accessibilità e argomenti correlati, vedere la sicurezza
di Extron e Regulatory Compliance Guide, parte numero
68-290-01, sul sito Web Extron,
www.extron.com.
Instrukcje bezpieczestwa • Polska
OSTRZEENIE: Ten symbol, , gdy uywany na produkt, ma na celu
poinformowa uytkownika o obecnoci izolowanego i niebezpiecznego
napicia wewntrz obudowy produktu, który moe stanowi zagroenie
poraenia prdem elektrycznym.
UWAGI: Ten symbol, , gdy uywany na produkt, jest przeznaczony do
ostrzegania uytkownika wane operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposaone w sprzt.
Informacji na temat wytycznych w sprawie bezpieczestwa, regulacji
wzajemnej zgodnoci, zgodno EMI/EMF, dostpnoci i Tematy pokrewne,
zobacz Extron bezpieczestwa i regulacyjnego zgodnoci przewodnik, cz
numer 68-290-01, na stronie internetowej Extron,
www.extron.com.
Инструкция по технике безопасности • Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии неизолированного опасного напряжения
внутри корпуса продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
and Regulatory Compliance Guide』 (P/N 68-290-01) をご覧ください。
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class B Notice
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part15 of the FCC rules. These limits provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. There is no
guarantee that interference will not occur. If this equipment does cause interference to radio
or television reception, which can be determined by turning the equipment off and on, you
are encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
• Consult the dealer or an experienced radio/TV technician for help.
In order to maintain compliance with FCC regulations, shielded cables must be used with
this equipment. Operation with non-approved equipment or unshielded cables is likely to
result in interference to radio and TV reception. The user is cautioned that changes and
modifications made to the equipment without the approval of the manufacturer could void
the user’s authority to operate this equipment.
the following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including interference that
may cause undesired operation.
connected.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/
EMF compatibility, accessibility, and related topics see the “Extron Safety and
Regulatory Compliance Guide” on the Extron website.
Over Temp Indicator LED ........................... 23
XTRA Series Half-Rack Audio Power Amplifiers • Contentsvi
Introduction
About this Manual
This manual contains information about the Extron XTRA Series of power amplifiers.
• XPA 1002 two-channel stereo audio power amplifier
• XPA 1002 Plus two-channel stereo audio power amplifier
• XPA 1002-70V two-channel audio power amplifier
• XPA 1002-100V two-channel audio power amplifier
• XPA 2001-70V mono audio power amplifier
• XPA 2001-100V mono audio power amplifier
Terms Used in this Manual
The terms “amplifier” and “power amplifier” are used interchangeably in this manual to refer
to all of the XPA models. “XPA 1002 series” refers to the XPA 1002, XPA 1002 Plus,
XPA 1002-70V, and XPA 1002-100V products. ”XPA2001” refers to both the XPA2001-70V
and the XPA2001-100V products.
Features
• Inputs — Balanced or unbalanced stereo or mono on a 3.5 mm, 5-pole captive screw
secure connections with 22 AWG to 12 AWG speaker cables.
• Continuous power output for larger rooms —
• XPA1002: 60watts rms per channel at 8 ohms; 100watts rms per channel at
4ohms.
• XPA 1002 Plus: 100 watts rms per channel at 4 and 8 ohms.
• XPA 1002-70V: 100 watts rms per channel for 70 volt speaker systems.
• XPA 1002-100V: 100 watts rms per channel for 100 volt speaker systems.
• XPA2001-70V: 200watts rms for 70volt speaker systems.
• XPA2001-100V: 200watts rms for 100volt speaker systems.
• Professional grade amplifier design —
• The XPA 1002 and XPA 1002 Plus features less than 0.05% total harmonic
distortion plus noise, and better than 105 dB signal-to-noise ratio.
• The XPA 1002-70V, XPA 1002-100V, and XPA 2001 series feature less than 0.1%
total harmonic distortion plus noise, and better than 100 dB signal to noise ratio.
• ENERGY STAR® qualified amplifier — The XTRA Series of amplifiers are energy
efficient products that conserve energy and reduce operating costs.
XTRA Series Half-Rack Audio Power Amplifiers • Introduction1
• Highly efficient Class D amplifier design — The XTRA Series of amplifiers
generate substantially less heat than conventional amplifier designs, making them
ideal for installation in equipment racks and lecterns with very limited ventilation. They
consume 10watts when idle and less than 1 watt in standby mode.
• Extron patented CDRS — Class D ripple suppression — A patented, exclusive
technology from Extron that eliminates the high frequency switching ripple and EMI
emissions found in typical Class D amplifiers. CDRS enables Extron power amplifiers
to be situated near wireless AV devices without RF interference.
• Convection cooled — The XTRA Series of amplifiers are convection cooled without
the need for fans, ensuring quiet, reliable operation.
• Ultra low inrush current — no need for power sequencing — Allows many
XTRA series amplifiers to be powered on simultaneously without overloading power
circuits. This eliminates the need for power sequencing.
• Flexible Conduit Adapter Kit — Suitable for use in other environmental air space in
accordance with section 300.22, (C) of the National Electrical Code only when used
with optional Flexible Conduit Adapter Kit.
• Auto-standby with fast power-up — The amplifiers automatically enter into a
standby mode after 25 minutes of inactivity, + or - 5 minutes, dramatically reducing
power consumption. They quickly return to full power status upon signal detection.
• Rear panel attenuation (level) controls — Provide attenuation of input signals for
setting proper audio system gain staging as well as two-zone applications. They are
located on the rear panel to prevent unauthorized or accidental tampering of the level
adjustments.
thermal overload, or DC faults to prevent damage to the amplifier and speakers.
• Remote standby port — Enables the amplifiers to be remotely powered down when
not in use, reducing operating cost.
• Remote volume and mute control port — This port allows the XPA 1002,
XPA 1002 Plus, and the XPA 2001 series to be remotely controlled using the optional
Extron VCM100 Series volume and mute or VC50 volume controllers.
• Bridgeable outputs — The power output of the XPA 1002 and XPA 1002 Plus can
be effectively doubled by bridging the output. A mono source is wired to both the left
and right input while the output is wired for bridged operation. Bridging allows power
to be output at 200 watts into 8 ohms. The minimum load impedance when bridging
is 8 ohms (see the Bridged Mono Output wiring instructions on page 20).
• Front and rear-mounted signal and protection indication LEDs — Provide
convenient indication of amplifier operation from both sides of an equipment rack.
• Internal international power supply — The 100-240 VAC, 50-60Hz universal
power supply provides worldwide power compatibility.
XTRA Series Half-Rack Audio Power Amplifiers • Introduction2
Installation
Blu-ray
This section discusses how to install the XTRA Series of audio power amplifiers.
Topics that are covered, include:
• Application Examples
• Mounting the XTRA Series Amplifiers
WARNING: Installation and service must be performed by authorized personnel only.
AVERTISSEMENT : L’installation et l’entretien doivent être effectués par le
personnel autorisé uniquement.
Application Examples
The following illustrations are application examples for the XPA 1002/1002 Plus, XPA
1002-70V/100V, and the XPA 2001 series.
Extron
XPA 1002 Plus
Power Amplier
VGA
Audio
Laptop
2
1
14
XPA 1002 Plus
18
26
SIGNAL
100-240V 0.5A, 50-60Hz
LIMITER/PROTECT
1606
IN
5
INPUTSOUTPUTS AUDIO INPUTS OUTPUTS REMOTE
HDMI
6
3
HDMI
4
1
LEB
MAX
-- A
CONFIGURA
100-240V ~ 50/60 Hz
2
HDMI
Audio
PC
Laptop
21
ATTENUATION
8
10
6
12
4
8
14
2
10
6
12
0
4
2
∞
0
∞
A
HDMI
B
2
8Ω / 4Ω OUTPUTS
1
REMOTE
STANDBY
10V 50mA
G
INPUTS
2
CLASS 2 WIRING
1
G
CV
Extron
IN1606
Scaling
Presentation
Switcher
R
+48V
5
L
R
6
R
+48V
L
3
L
R
4
R
L
1
L
R
2
L
DisplayPort
to HDMI
Adapter
1
MIC/LI
2
Audio
1 2
RIABLE
A
V
L R
NE
Audio
RESET
Audio
Extron
SM 26
SurfaceMount
Speakers
Extron
Extron
IPCP Pro 250
Control Processor
IPCPPRO250
IPCP PRO 250
1000
DIGITAL I/O
LINK
RELAYS
IR
ACT
1
IR/S
COM 2
I/O
34G
2
21
S
/
1
IR
LAN
G
eBUS
2
COM
COM 1
G
TxRx
-S
4
RTS
S
SG
+V+S
3
RELAY
CTS
G
eBUS
12C
Tx
TxRxRTSCTS
LIMIT
2
S
VOL
PWR OUT=6W
1
Rx
VCG
R
OVER
POWER12V
--A MAX
Ethernet
Audio
Microphones
1 and 2
HDMI with
Embedded
Audio
-232
RS
LAN
G
TxRx
Extron
TCP/IP
Network
Extron
TLP Pro 1020T
10” Ta bletop
TouchLink Pro
Touchpanel
1 2 3
Tuner
Doc
Volume
Cam
VCR
Presets
DVD
Mute
Channel
uner
PC
T
Laptop
3
More
Audio
Presets
2
Control
Last
6
1
System
Display
5
Off
9
On
4
8
Off
Enter
7
0
Mute
December 15, 2013 - 7:58 AM
Room
Control
Help
Screen
Lighting
Display
Display
HDMI with
Embedded
Audio
HDMI with
Embedded Audio
Figure 1. XPA 1002 and 1002 Plus Application Example
XTRA Series Half-Rack Audio Power Amplifiers • Installation3
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.