04 16
Page 2
Safety Instructions
Safety Instructions • English
WARNING:This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within
the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website,
www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website,
www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron,
www.extron.com.
Istruzioni di sicurezza • Italiano
AVVISO: Questo simbolo, ,quando viene utilizzato il prodotto, serve
ad avvisare l’utente della presenza di tensioni pericolose non isolate
all’interno del prodotto, che può presentare un rischio di scosse
elettriche.
ATTENTZIONE: Questo simbolo, , quando viene utilizzato il
prodotto, serve ad avvisare l’utente di importanti istruzioni di uso e
manutenzione (assistenza) nella letteratura fornita con l’apparecchiatura.
Per informazioni sulle linee guida di sicurezza, adempimenti normativi,
compatibilità EMI/EMF, accessibilità e argomenti correlati, vedere la sicurezza
di Extron e Regulatory Compliance Guide, parte numero
68-290-01, sul sito Web Extron,
www.extron.com.
Instrukcje bezpieczestwa • Polska
OSTRZEENIE: Ten symbol, , gdy uywany na produkt, ma na celu
poinformowa uytkownika o obecnoci izolowanego i niebezpiecznego
napicia wewntrz obudowy produktu, który moe stanowi zagroenie
poraenia prdem elektrycznym.
UWAGI: Ten symbol, , gdy uywany na produkt, jest przeznaczony do
ostrzegania uytkownika wane operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposaone w sprzt.
Informacji na temat wytycznych w sprawie bezpieczestwa, regulacji
wzajemnej zgodnoci, zgodno EMI/EMF, dostpnoci i Tematy pokrewne,
zobacz Extron bezpieczestwa i regulacyjnego zgodnoci przewodnik, cz
numer 68-290-01, na stronie internetowej Extron,
www.extron.com.
Инструкция по технике безопасности • Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии неизолированного опасного напряжения
внутри корпуса продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
and Regulatory Compliance Guide』 (P/N 68-290-01) をご覧ください。
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
Page 4
FCC Class B Notice
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part15 of the FCC rules. These limits provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. There is no
guarantee that interference will not occur. If this equipment does cause interference to radio
or television reception, which can be determined by turning the equipment off and on, you
are encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
• Consult the dealer or an experienced radio/TV technician for help.
In order to maintain compliance with FCC regulations, shielded cables must be used with
this equipment. Operation with non-approved equipment or unshielded cables is likely to
result in interference to radio and TV reception. The user is cautioned that changes and
modifications made to the equipment without the approval of the manufacturer could void
the user’s authority to operate this equipment.
the following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including interference that
may cause undesired operation.
connected.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/
EMF compatibility, accessibility, and related topics see the “Extron Safety and
Regulatory Compliance Guide” on the Extron website.
Over Temp Indicator LED ........................... 23
XTRA Series Half-Rack Audio Power Amplifiers • Contentsvi
Page 7
Page 8
Introduction
About this Manual
This manual contains information about the Extron XTRA Series of power amplifiers.
• XPA 1002 two-channel stereo audio power amplifier
• XPA 1002 Plus two-channel stereo audio power amplifier
• XPA 1002-70V two-channel audio power amplifier
• XPA 1002-100V two-channel audio power amplifier
• XPA 2001-70V mono audio power amplifier
• XPA 2001-100V mono audio power amplifier
Terms Used in this Manual
The terms “amplifier” and “power amplifier” are used interchangeably in this manual to refer
to all of the XPA models. “XPA 1002 series” refers to the XPA 1002, XPA 1002 Plus,
XPA 1002-70V, and XPA 1002-100V products. ”XPA2001” refers to both the XPA2001-70V
and the XPA2001-100V products.
Features
• Inputs — Balanced or unbalanced stereo or mono on a 3.5 mm, 5-pole captive screw
secure connections with 22 AWG to 12 AWG speaker cables.
• Continuous power output for larger rooms —
• XPA1002: 60watts rms per channel at 8 ohms; 100watts rms per channel at
4ohms.
• XPA 1002 Plus: 100 watts rms per channel at 4 and 8 ohms.
• XPA 1002-70V: 100 watts rms per channel for 70 volt speaker systems.
• XPA 1002-100V: 100 watts rms per channel for 100 volt speaker systems.
• XPA2001-70V: 200watts rms for 70volt speaker systems.
• XPA2001-100V: 200watts rms for 100volt speaker systems.
• Professional grade amplifier design —
• The XPA 1002 and XPA 1002 Plus features less than 0.05% total harmonic
distortion plus noise, and better than 105 dB signal-to-noise ratio.
• The XPA 1002-70V, XPA 1002-100V, and XPA 2001 series feature less than 0.1%
total harmonic distortion plus noise, and better than 100 dB signal to noise ratio.
• ENERGY STAR® qualified amplifier — The XTRA Series of amplifiers are energy
efficient products that conserve energy and reduce operating costs.
XTRA Series Half-Rack Audio Power Amplifiers • Introduction1
Page 9
• Highly efficient Class D amplifier design — The XTRA Series of amplifiers
generate substantially less heat than conventional amplifier designs, making them
ideal for installation in equipment racks and lecterns with very limited ventilation. They
consume 10watts when idle and less than 1 watt in standby mode.
• Extron patented CDRS — Class D ripple suppression — A patented, exclusive
technology from Extron that eliminates the high frequency switching ripple and EMI
emissions found in typical Class D amplifiers. CDRS enables Extron power amplifiers
to be situated near wireless AV devices without RF interference.
• Convection cooled — The XTRA Series of amplifiers are convection cooled without
the need for fans, ensuring quiet, reliable operation.
• Ultra low inrush current — no need for power sequencing — Allows many
XTRA series amplifiers to be powered on simultaneously without overloading power
circuits. This eliminates the need for power sequencing.
• Flexible Conduit Adapter Kit — Suitable for use in other environmental air space in
accordance with section 300.22, (C) of the National Electrical Code only when used
with optional Flexible Conduit Adapter Kit.
• Auto-standby with fast power-up — The amplifiers automatically enter into a
standby mode after 25 minutes of inactivity, + or - 5 minutes, dramatically reducing
power consumption. They quickly return to full power status upon signal detection.
• Rear panel attenuation (level) controls — Provide attenuation of input signals for
setting proper audio system gain staging as well as two-zone applications. They are
located on the rear panel to prevent unauthorized or accidental tampering of the level
adjustments.
thermal overload, or DC faults to prevent damage to the amplifier and speakers.
• Remote standby port — Enables the amplifiers to be remotely powered down when
not in use, reducing operating cost.
• Remote volume and mute control port — This port allows the XPA 1002,
XPA 1002 Plus, and the XPA 2001 series to be remotely controlled using the optional
Extron VCM100 Series volume and mute or VC50 volume controllers.
• Bridgeable outputs — The power output of the XPA 1002 and XPA 1002 Plus can
be effectively doubled by bridging the output. A mono source is wired to both the left
and right input while the output is wired for bridged operation. Bridging allows power
to be output at 200 watts into 8 ohms. The minimum load impedance when bridging
is 8 ohms (see the Bridged Mono Output wiring instructions on page 20).
• Front and rear-mounted signal and protection indication LEDs — Provide
convenient indication of amplifier operation from both sides of an equipment rack.
• Internal international power supply — The 100-240 VAC, 50-60Hz universal
power supply provides worldwide power compatibility.
XTRA Series Half-Rack Audio Power Amplifiers • Introduction2
Page 10
Installation
Blu-ray
This section discusses how to install the XTRA Series of audio power amplifiers.
Topics that are covered, include:
• Application Examples
• Mounting the XTRA Series Amplifiers
WARNING: Installation and service must be performed by authorized personnel only.
AVERTISSEMENT : L’installation et l’entretien doivent être effectués par le
personnel autorisé uniquement.
Application Examples
The following illustrations are application examples for the XPA 1002/1002 Plus, XPA
1002-70V/100V, and the XPA 2001 series.
Extron
XPA 1002 Plus
Power Amplier
VGA
Audio
Laptop
2
1
14
XPA 1002 Plus
18
26
SIGNAL
100-240V 0.5A, 50-60Hz
LIMITER/PROTECT
1606
IN
5
INPUTSOUTPUTS AUDIO INPUTS OUTPUTS REMOTE
HDMI
6
3
HDMI
4
1
LEB
MAX
-- A
CONFIGURA
100-240V ~ 50/60 Hz
2
HDMI
Audio
PC
Laptop
21
ATTENUATION
8
10
6
12
4
8
14
2
10
6
12
0
4
2
∞
0
∞
A
HDMI
B
2
8Ω / 4Ω OUTPUTS
1
REMOTE
STANDBY
10V 50mA
G
INPUTS
2
CLASS 2 WIRING
1
G
CV
Extron
IN1606
Scaling
Presentation
Switcher
R
+48V
5
L
R
6
R
+48V
L
3
L
R
4
R
L
1
L
R
2
L
DisplayPort
to HDMI
Adapter
1
MIC/LI
2
Audio
1 2
RIABLE
A
V
L R
NE
Audio
RESET
Audio
Extron
SM 26
SurfaceMount
Speakers
Extron
Extron
IPCP Pro 250
Control Processor
IPCPPRO250
IPCP PRO 250
1000
DIGITAL I/O
LINK
RELAYS
IR
ACT
1
IR/S
COM 2
I/O
34G
2
21
S
/
1
IR
LAN
G
eBUS
2
COM
COM 1
G
TxRx
-S
4
RTS
S
SG
+V+S
3
RELAY
CTS
G
eBUS
12C
Tx
TxRxRTSCTS
LIMIT
2
S
VOL
PWR OUT=6W
1
Rx
VCG
R
OVER
POWER12V
--A MAX
Ethernet
Audio
Microphones
1 and 2
HDMI with
Embedded
Audio
-232
RS
LAN
G
TxRx
Extron
TCP/IP
Network
Extron
TLP Pro 1020T
10” Ta bletop
TouchLink Pro
Touchpanel
1 2 3
Tuner
Doc
Volume
Cam
VCR
Presets
DVD
Mute
Channel
uner
PC
T
Laptop
3
More
Audio
Presets
2
Control
Last
6
1
System
Display
5
Off
9
On
4
8
Off
Enter
7
0
Mute
December 15, 2013 - 7:58 AM
Room
Control
Help
Screen
Lighting
Display
Display
HDMI with
Embedded
Audio
HDMI with
Embedded Audio
Figure 1. XPA 1002 and 1002 Plus Application Example
XTRA Series Half-Rack Audio Power Amplifiers • Installation3
Page 11
RS-232 (1)
Po
Microphone
RESET
LAN
TxRxG
23
23 G
RS-232 (2)
1
REMOTE
I/O
TxRxG
45 6 G
OUTPUTS
MIC
+48V
21
1 2 3
1
5 6
4
dium
Extron
DMP 64
Digital Matrix
Processor
Wireless
Microphone System
DMP 64
4 53 46
POWER
12V
MIC/LINE INPUTS
1.0A MAX
Extron
XPA 1002-70V
Power Amplier
100-240V x.xA MAX, 50-60Hz
LIMITER/PROTECT
100-240V x.xA MAX, 50-60Hz
2
70V OUTPUTS
1
REMOTE
STANDBY
G
2
INPUTS
CLASS 2 WIRING
1
HPF
80 Hz
2
8
ATTENUATION
10
6
1
12
4
2
14
8
10
6
2
0
12
4
OFF
1
XPA 1002-70V
2
14
18
0
26
SIGNAL
LIMITER/PROTECT
Extron
SI 3CT LP
Full-Range
Ceiling Speakers
Extron
XPA 1002-70V
Power Amplier
2
70V OUTPUTS
1
REMOTE
STANDBY
G
2
INPUTS
CLASS 2 WIRING
1
HPF
80 Hz
2
8
ATTENUATION
10
6
1
12
4
2
14
8
10
6
2
0
12
4
OFF
1
XPA 1002-70V
2
14
18
0
6
2
SIGNAL
Extron
SI 3CT LP
Full-Range
Ceiling Speakers
Figure 2. XPA 1002-70V/100V Application Example
Extron
Extron
Extron
Extron
Extron
Extr
Extron
on
Extron
V OUTPUT
70
REMOTE
50mA
STANDBY
0V
1
G
2 WIRING
INPUTS
CLASS
R
(SUMMED)
HPF
L
GCV
NUATION
ATTE
80 Hz
8
10
6
F
F
O
12
4
14
2
XPA 2001-70V
18
0
26
∞
GNAL
SI
ITER/PROTECT
100-240V 0.5A, 50-60Hz
LIM
Extron
XPA 2001-70V
Power
Amplier
R
L
-D / AUDIO
VI
D
OUTPUT
8
2
1
OWER
P
12V
MAX
4A
0.
Extron
SW8 DVI A Plus
DVI Switcher
W/ Audio
S
T
DVI / AUDIO INPU
4
3
DVI
7
6
5
DVI
SW8 DVI A PLUS
VCR
DVD
DOC
AM
C
LAPTOP
PC
ON
OFF
DISPLAY
UTE
M
SCREEN
UP
CREEN
S
DOWN
TouchLink
Control
TCP/IP
System
®
00
1
RELAY
LINK
ACT
31
INPUT
IR
3
1
4
31
COM
2
X
4
XR
T
2
IPL 250
1
42
2
R
3
RS-232
MOTE / AUTO-SW
RE
A S
TxRx
DVI
DVI
PC with DVI Out
Extron
Extron
Extron
SF 228T
Plenum 2' x 2'
Ceiling Speaker
Projector with DVI In
Figure 3. XPA 2001 Series Application Example
Laptop with DVI Out
PC with DVI Out
XTRA Series Half-Rack Audio Power Amplifiers • Installation4
Page 12
Mounting the XTRA Series Amplifiers
The XPA 1002 series and XPA 2001 series of audio amplifiers can be set on a table,
mounted on a rack shelf, or mounted in the plenum space above a ceiling-mounted
projector.
Tabletop Use
Four self-adhesive rubber feet are included with the audio amplifier.
For tabletop use, attach one foot at each corner of the bottom side of the unit and place
the unit in the desired location.
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines pertain to the installation of the
equipment in a rack.
1. Elevated operating ambient — If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consider installing the equipment in an environment compatible
with the maximum ambient temperature specified by the manufacturer [Tma = +32 to
+122 °F (0 to +50 °C)].
2. Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
3. Mechanical loading — Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
4. Circuit overloading — Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
5. Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to supply connections
other than direct connections to the branch circuit (such as the use of power strips).
Rack Mounting
The XPA 1002 series and XPA 2001 series can be mounted in a rack shelf using the
optional RSU 129 1U Universal rack shelf or the 1U Basic rack shelf, as follows.
1. If feet were installed on the bottom of the amplifier, remove them.
2. Place the amplifier on one half of the rack shelf.
3. Align the front of the amplifier with the front of the shelf, and align the threaded
holes on the bottom of the amplifier with the holes in the rack shelf.
4. Attach the amplifier to the rack shelf with the two provided 4-40 x 3/16" machine
screws.
ATTENTION:
• Using screws longer than 3/16" will damage the unit and void the warranty.
• L’utilisation de vis plus longues que 3/16" endommagera l’unité et annulera
la garantie.
XTRA Series Half-Rack Audio Power Amplifiers • Installation5
Page 13
5. Insert the screws from the underside of the shelf, and securely fasten them into
diagonally-opposite corners.
1U Universal Rack Shelf
1/2 Rack Width Front False
Faceplate
Front false
faceplate
uses 2
screws.
(2) 4-40 x 3/16"
Screws
Use 2 mounting holes on
opposite corners.
Figure 4. Rack Mounting of the Amplifier
6. Attach the false front panel (provided with rack shelf) to the unoccupied side of the
rack (as shown on the previous page), or install a second half-rack-width device in
that side by repeating steps 1 through 5.
7. Attach the rack shelf to the rack using four 10-32 x ¾" bolts (provided). Insert the
bolts through #10 beveled washers, then through the holes in the rack, as shown
above.
Rack Mounting Ventilation Recommendations
Excessive heat can decrease the optimal lifetime of the power amplifier. An over temp
indicator LED on the front panel of the amplifier lights red whenever the recommended
operating temperature has been exceeded (see Front Panel Features and Operation
on page 10).
To reduce the chances for an over temp condition, the XPAs should be arranged in a
rack environment so that adequate airflow is available both above and below the XPA
whenever possible. No more than two XPAs should be arranged one-on-top-of-the-other
in a rack without an open space between them, as shown in the following illustration. An
XPA can also be arranged above or below another non-XPA device, but there must be an
open space both above and below those devices (see the image below).
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
XTRA Series Half-Rack Audio Power Amplifiers • Installation6
Page 14
Flexible Conduit Adapter Kit Installation
WARNING:
AVERTISSEMENT :
• The circuit breaker used for this connection should be rated no lower than 20
amps and no greater than 30 amps.
• Le disjoncteur utilisé pour cette connexion devrait avoir une cote comprise entre
20 et 30amps.
• This unit must be installed in accordance with the National Electrical Code and
with all local codes.
• L’unité doit être installée conformément au NationalElectricCode et aux normes
électriques et de sécurité locales.
• An ALL-POLE MAINS SWITCH with a contact separation of at least 3 mm in
each pole shall be incorporated in the electrical installation of the building. The
installation shall be carried out in accordance with all applicable installation rules.
• Un interrupteur omnipolaire avec une séparation contact d’au moins 3mm dans
chaque pôle, devra être incorporée dans l’installation électrique du bâtiment.
L’installation doit être réalisée conformément à toutes les règles d’installation
applicables.
• Installation and service must be performed by a qualified electrician only.
• L’installation et l’entretien doivent être effectués uniquement par un électricien
qualifié.
• Make sure that the source device and the XPA are turned off and disconnected
from the power source before you begin.
• Éteindre tous les appareils d’entrée et de sortie puis retirer les câbles
d’alimentation. Vérifiez que le XPA soit déconnecté de la source d’alimentation
avant de procéder.
• To reduce the risk of fire or electric shock, do not expose this apparatus to rain
or moisture.
• Afin de réduire les risques d’incendie ou de choc électrique, protégez cet
appareil de la pluie ou de l’humidité.
• The Product is a Class I product, which must be connected only to a mains
socket outlet with a protective earthing (grounding) connection.
• Ce produit est un produit de ClasseI, qui doit être connecté seulement à une
prise femelle secteur équipée d’une connexion de mise à la terre.
• The mains plug/appliance coupler is used as the disconnect device and shall
remain readily operable.
• La fiche secteur ou le coupleur est un système de déconnexion dont le
fonctionnement immédiat constitue un facteur essentiel.
ATTENTION:
• A UL-listed electrical distribution box is recommended for the termination of the
conduit opposite the XPA (see the UL Requirements section on page 8).
• Un boîtier de distribution électrique listé UL est recommandé pour la terminaison
du conduit à l’opposé du XPA.
The optional Flexible Conduit Adapter Kit consists of:
• One EMT adapter plate
• One 6-foot long electrical conduit
• Three 7.5 feet, 18-gauge spade connector power wires
XTRA Series Half-Rack Audio Power Amplifiers • Installation7
Page 15
• One UL rated zip tie wrap
• Three auxiliary crimp style spade connectors designed for 14- to 16-gauge wires
NOTE: If needed, Extron recommends using a UL-rated crimp tool to terminate
the spade connectors. One recommended choice is the Molex crimp tool.
The kit provides a convenient means to replace the IEC power cord of the XPA with
conduit, where required by local codes.
UL Requirements
The UL requirements listed below pertain to the installation of the flexible conduit onto an
XPA 1002 series or XPA 2001 series product.
• This unit is not to be used beyond its rated voltage range.
• This unit must be wired to a UL-listed distribution box.
NOTE: The UL-approved electrical distribution box is not included with either
the XPA or the Flexible Conduit Adapter Kit. The installer is responsible for
obtaining and installing the box.
Installing the Flexible Conduit Kit
ATTENTION:
• Electrostatic discharge (ESD) can damage IC chips even though you cannot feel
it. You must be electrically grounded before touching anything inside the XPA. A
grounding wrist strap is recommended.
• Les décharges électrostatiques peuvent endommager les puces de circuit
même si vous ne pouvez pas les sentir, les voir ou les entendre. Vous devez être
électriquement relié à la terre avant de toucher quoique ce soit à l’intérieur du
XPA. Un bracelet de mise à la terre est recommandé.
Install flexible conduit to the XPA by following the steps below.
1. Unplug the IEC power cord from the power amplifier.
2. Remove the 8 screws from the top and sides of the XPA and lift off the cover
(see figure 5).
Lift Cover Straight Up
Remove (8)
screws
2
8Ω / 4Ω OUTPUTS
1
REMOTE
STANDBY
10V 50mA
G
INPUTS
2
CLASS 2 WIRING
1
GCV
21
ATTENUATION
8
10
6
12
4
8
14
2
10
6
2
12
0
4
1
14
XPA 1002
2
∞
18
0
26
∞
SIGNAL
100-240V 0.5A, 50-60Hz
LIMITER/PROTECT
Figure 5. Removing the Cover
XTRA Series Half-Rack Audio Power Amplifiers • Installation8
Page 16
3. Remove the 2 screws holding the hot (line) and neutral wires from the terminal block
on the PCB (see figure 6).
Blue Wire
L
N
Remove nut
Brown Wire
100-240V 1.3A
50-60Hz
Remove screws
(both sides) to release
IEC connector plate.
Figure 6. Removing the IEC Connector
4. Remove the ground wire nut from the grounding stud on the bottom of the enclosure,
as shown above.
5. Remove the 2 screws from the IEC plate, and remove the IEC connector plate and
the attached wires through the rear panel of the XPA, as shown in the previous figure.
6. Thread the 18-gauge power wires through the length of the electrical conduit tube.
7. Install the EMT adapter plate with conduit attached into the opening from which the
IEC connector was removed in step 5.
8. Slide the conduit nut over the bundle of wires exiting the conduit and onto the conduit
itself. Hand tighten the conduit nut to the conduit.
9. Attach the EMT adapter plate assembly to the XPA using the 2 screws that were
removed in step 5.
10. Connect the black hot (line) and white neutral wires to the terminal block on the PCB
using the 2 screws that were removed in step 3. Use the included zip tie wrap to
secure the two wires together close to the terminals (see figure 7).
WARNING: Ensure that you observe correct wire polarity. The following
illustration shows the location of the hot (Line) and neutral terminals.
AVERTISSEMENT :Respecter la polarité correcte des câble. L’illustration
suivante indique l’emplacement des bornes de ligne et de neutre.
Zip-Tie
LINE
NEUTRAL
EMT Adapter Plate
Te rminal Block
L
N
Conduit Nut
Hot
Te rminal (Black)
Neutral
Te rminal (White)
Ground
Wire Nut
Figure 7. Installing the EMT Adapter Plate Assembly
11. Connect the ground wire, as shown above, to the grounding stud on the bottom of
the enclosure using the nut that was removed in step 4.
12. Replace the cover of the XPA by attaching the 8 screws that were removed in step 2.
XTRA Series Half-Rack Audio Power Amplifiers • Installation9
Page 17
Operation
X
This section discusses how to operate the XTRA Series of half-rack audio power
amplifiers. Topics that are covered, include:
• Front Panel Features and Operation
• Rear Panel Features and Operation
• Troubleshooting
Front Panel Features and Operation
BC
12
OVER
A
TEMP
XPA 1002 Series
Front Panel
B
D
C
LIMITER/PROTECT
SIGNAL
XPA 1002
A Power Indicator LED
B Over Temp Indicator LED
Limiter/Protect Indicator
C
LEDs
A
PA 2001 Series
Front Panel
A Power indicator LED — This LED lights:
B Over Temp indicator LED — This LED lights red when the amplifier exceeds the
OVER
TEMP
LIMITER/PROTECT
SIGNAL
XPA 2001
D Signal Indicator LEDs
D
Figure 8. XPA 1002 and XPA 2001 Series Front Panel
• Green when the amplifier is receiving full power.
• Amber when the amplifier is in Standby mode. Standby mode turns off all outputs
from the amplifier, although the amplifier is still receiving power (see G and Hof
“Rear Panel Features and Operation” on pages 14 and 15, respectively).
recommended operating temperature for optimal lifetime. The LED will turn off after
the amplifier has cooled down sufficiently.
Should the LED light, check the following:
• Verify that the placement of the amplifier allows for adequate ventilation and
airflow.
• Avoid placing other equipment on top of the amplifier.
• Verify that the operating temperature is within the specified range.
XTRA Series Half-Rack Audio Power Amplifiers • Operation10
Page 18
CLimiter/Protect indicator LEDs — These LEDs (representing their respective output
channels) light red under three circumstances:
12
LIMITER/PROTECT
• When the output wiring is shorted together.
• When audio clipping occurs, the LED of the corresponding channel blinks once
per clip occurrence.
• When the amplifier overheats, both LEDs are lit. The LEDs are not lit after the
amplifier recovers from the overheated condition.
NOTE: These LEDs are also located on the rear panel.
DSignal indicator LEDs — These LEDs (representing their respective output
channels) light green only when an input signal is detected on the corresponding
channel.
12
SIGNAL
NOTE: These LEDs are also located on the rear panel.
XTRA Series Half-Rack Audio Power Amplifiers • Operation11
Page 19
Rear Panel Features and Operation
B
100-240V 0.5A, 50-60Hz
A
XPA 1002
Rear Panel
100-240V 0.5A MAX, 50-60Hz
A
XPA 1002 Plus
Rear Panel
100-240V 0.5A MAX, 50-60Hz
A
XPA 1002-70V
Rear Panel
100-240V 0.5A MAX, 50-60Hz
A
XPA 1002-100V
Rear Panel
100-240V 0.5A, 50-60Hz
A
XPA 1002
LIMITER/PROTECT
SIGNAL
XPA 1002 Plus
LIMITER/PROTECT
SIGNAL
XPA 1002-70V
LIMITER/PROTECT
SIGNAL
XPA 1002-100V
LIMITER/PROTECT
SIGNAL
XPA 2001-70V
LIMITER/PROTECT
SIGNAL
REMOTE
10V 50mA
C
V
G
G
STANDBY
8Ω / 4Ω OUTPUTS
1
CLASS 2 WIRING
ATTENUATION
2
1
10
12
8
6
14
14
18
4
2
26
0
∞
INPUTS
1
21
10
12
8
0
∞
2
6
4
2
CD EG I
B
1
ATTENUATION
2
12
14
18
26
1
10
8
14
6
4
2
0
1
10
12
8
0
2
6
4
2
INPUTS
2
10V
REMOTE
V
50mA
G
C
G
STANDBY
8Ω / 4Ω OUTPUTS
1
CLASS 2 WIRING
CDEG I
B
ATTENUATION
1
1
2
10
12
8
14
14
6
18
4
26
2
0
DCEHI
INPUTS
HPF
2
1
2
80 Hz
10
12
8
6
4
2
0
OFF
K
REMOTE
G
100V OUTPUTS
STANDBY
CLASS 2 WIRING
1
B
ATTENUATION
1
1
2
10
12
8
14
14
6
18
4
26
2
0
DCEHI
INPUTS
HPF
2
1
2
80 Hz
10
12
8
6
4
2
0
OFF
K
REMOTE
G
100V OUTPUTS
STANDBY
CLASS 2 WIRING
1
B
ATTENUATION HPF
10
12
8
6
14
80 Hz
18
4
2
26
0
∞
INPUTS
10V
L
(SUMMED)
R
OFF
REMOTE
50mA
GCV
G
70 V OUTPUT
STANDBY
CLASS 2 WIRING
2
AC Power Connector
2
A
B Limiter/Protect Indicator
LEDs
C Signal Indicator LEDs
D Attenuation Potentiometers
E Audio Input Receptacle
2
(XPA 1002 Series)
F Audio Input Receptacle
(XPA 2001 Series)
G Remote Control Port
(XPA 1002, XPA 1002 Plus,
and XPA 2001 only)
H Remote Control Port
2
(XPA 1002-70V/100V only)
I Stereo Audio Output
Receptacle (XPA 1002
Series)
J Mono Audio Output
Receptacle (XPA 2001
Series)
K High Pass Filter
(XPA 1002-70V/100V and
2001 Series)
XPA 2001-70V
Rear Panel
100-240V 0.5A, 50-60Hz
A
XPA 2001-100V
Rear Panel
Figure 9. XTRA Series Rear Panel
NOTE: Control signal ground pins may be labeled as , , or “G”. Audio ground pins
may be labeled as or .
The wiring and function are the same, whichever way your product is labeled.
XPA 2001-100V
LIMITER/PROTECT
SIGNAL
CD KFGJ
B
ATTENUATION HPF
10
12
8
6
14
18
4
2
26
0
∞
INPUTS
50mA
10V
L (SUMMED)
R
G
80 Hz
OFF
STANDBY
GCV
CLASS 2 WIRING
100 V OUTPUT
REMOTE
CD KFGJ
XTRA Series Half-Rack Audio Power Amplifiers • Operation12
Page 20
AAC power connector — Connect a standard IEC AC power cord here for power
input (100 VAC to 240 VAC, 50/60 Hz) to the internal, autoswitching power supply.
This connector may be replaced by the Flexible Conduit Adapter Kit as described in
Flexible Conduit Adapter Kit Installation on page 8.
BLimiter/Protect indicator LEDs — These LEDs light red under certain
circumstances (see C of Front Panel Features and Operation on page 11 for
more details).
CSignal indicator LEDs — These LEDs light green only when an input signal is
detected on the corresponding channel (see D of Front Panel Features and
Operation on page 11 for more details).
DAttenuation potentiometers — Use a small screwdriver to adjust the audio input
level for the corresponding channel. The analog potentiometers control the level from
(full attenuation) to 0 dB.
=
ATTENUATION
21
10
12
14
18
26
∞
XPA 1002 SeriesXPA 2001 Series
10
12
8
8
6
6
14
4
4
2
0
2
0
∞
ATTENUATION
10
12
8
6
14
18
4
2
26
0
∞
LEVEL
12
00
XPA 1002XPA 2001 Series
LEVEL
0
NOTES:
• On the XPA 2001 models, the single control adjusts the levels of both
channels simultaneously prior to summing them together.
• On some models (early XPA 1002, XPA 2001), this adjustment is referred to
as “level”. The function is the same, whichever way your product is labeled.
To adjust the attenuation level of the XPA amplifier, do the following:
1. If connecting to a source device with a volume control (variable output), ensure
that the volume on the source device is set to its lowest point, then adjust the
attenuation of the XPA fully counterclockwise.
2. Set the volume of the source device to its maximum volume level. No sound
should come out.
3. Return to the XPA amplifier and raise the attenuation until sound distortion
occurs, then lower the level slightly until any distortion disappears. This setting
ensures that, whatever the source device volume setting may be, no clipping
occurs.
EBalanced or unbalanced stereo or mono audio input receptacle
(XPA 1002 series) — Wire the 3.5 mm 5-pin captive screw connector for balanced
or unbalanced input as shown in the diagram on the following page.
NOTE: When setting volume control through a source device, ensure that the
volume of the device is set to variable out. Consult the user manual of the
device for detailed instructions on its calibration.
XTRA Series Half-Rack Audio Power Amplifiers • Operation13
Page 21
NOTE: The power output of the XPA 1002 and XPA 1002 Plus amplifiers can
LR
Sleev
Sleev
be effectively doubled by bridging the output. A mono source is wired to both
the left and right input while the output is wired for bridged operation. Bridging
allows power to be ,output at 200 watts into 8 ohms. The minimum load
impedance when bridging is 8 ohms (see the Bridged Mono Output wiring
instructions on page 20).
2
LR
Tip
Ring
Sleeve
or
Balanced Mono Input
INPUTS
2
1
LR
Tip
Sleeve
Tip
Sleeve
Unbalanced Stereo Input
NOTE: On the XPA 1002 and XPA 2001, the
LR
Tip
Ring
Sleeves
Tip
Ring
Balanced Stereo Input
LR
Sleeve
Do not tin the wires!
Do not tin the wires!
Tip
Unbalanced Mono Input
input receptacle may be labeled one of two ways.
INPUTS
1
The wiring and function are the same, whichever
your product is labeled.
FBalanced or unbalanced stereo or mono audio input receptacle
(XPA 2001 series) — Wire the 3.5 mm 5-pin captive screw connector for balanced
or unbalanced input.
NOTE: For mono input on the XPA 2001 series, because the left and right
channels are summed, only the left channel needs to be wired. No jumpering to
the right channel is needed.
Tip
e
Tip
e
Unbalanced Stereo Input
LR
Tip
Ring
Sleeves
Tip
Ring
Balanced Stereo Input
LR
Tip
Sleeve
Unbalanced Mono Input
LR
Tip
Ring
Sleeve
Balanced Mono Input
NOTE: On the XPA 1002 and XPA 2001, the
input receptacle may be labeled one of two ways.
The wiring and function are the same, whichever
way your product is labeled.
GRemote control port (XPA 1002, XPA 1002 Plus, and XPA 2001 only) — The
3.5 mm, 5-pin captive screw port is used to remotely control two functions (see the
circuit diagram on the following page).
Do not tin the wires!
INPUTS
L
(SUMMED)
R
INPUTS
L(MONO)
R
or
XTRA Series Half-Rack Audio Power Amplifiers • Operation14
Page 22
NOTE: The remote control port on the XPA 1002 and XPA 2001 may be labeled
one of two ways (see the image below). The wiring and function are the same,
whichever way your product is labeled.
Pins V, C, and G (1, 2, and 3) control volume by varying the DC voltage from 0 V
(full attenuation) to 10 V (maximum volume) with full muting in effect when pin C is
connected to ground (pin G). Use the included 3-pin captive screw connector (see
Remote Volume Control on page 18).
10V50 mA
123
or
MUTE SWITCH
VOL/MUTE
STANDBY
1 V
2 C
3
45
MUTE
VOLUME
G
MAX
10K OHMS
MIN
REMOTE
10V 50mA
GCV
2K OHMS
G
STANDBY
Pin 5 connected to ground (pin 4) places the amplifier in standby mode. Standby
mode turns off all output, although the amplifier is still receiving power. Use the
included 2-pin, 3.5 mm captive screw connector to remotely ground pin 5.
The power indicator LED lights amber when the amplifier is in standby mode.
REMOTE
10V 50mA
GCV
or
10V50 mA
VOL/MUTE
G
STANDBY
Remote Switching to Standby Mode
V
GC
10V
50mA
G
STANDBY
HRemote control port (XPA 1002-70V, XPA 1002-100V) — This 3.5 mm,
2-pin captive screw receptacle is used to remotely place the amplifier into
standby. The standby pin connected to ground (G) places the amplifier in
standby mode. Standby mode turns off all output, although the amplifier
is still receiving power. Use the included 2-pin, 3.5 mm captive screw
connector to remotely ground the standby pin. The power indicator LED
lights amber when the amplifier is in standby mode.
IStereo audio output receptacle (XPA 1002 series) — Marked “1” and “2” for the
123 45
STANDBY
REMOTE
G
STANDBY
XTRA Series Half-Rack Audio Power Amplifiers • Operation15
Page 23
output channels, wire the included 5 mm, 4-pole screw lock captive screw connector
12
OUTPUT
XPA 1002
XPA 1002 Plus
XPA 1002-70V
XPA 1002-100V
CLASS 2 WIRING
1
2
8Ω/4Ω OUTPUTS
or
XPA 1002
to output audio. Observe the correct polarities for each channel (see the following
steps). For the low impedance models, the output is designed to power 4 or 8 ohm
speakers and is rated at 100 watts per channel at 4 ohms and 60 watts per channel
at 8 ohms for the non-Plus model, and 100 watts per channel at 4 and 8 ohms for the
Plus model.
For the high impedance models, the output is designed to power 70 volt
(XPA 1002-70V) or 100 volt (XPA 2001-100V) line distribution systems and is rated at
100 watts per channel.
NOTES:
• You must use Class 2 wiring for this output to comply with UL requirements.
• On the XPA 1002 and XPA 2001. the audio output receptacle may be
labeled one of two ways (see the images below). The wiring and function are
the same, whichever way your product is labeled.
ATTENTION:
• Do not tie channel output pins to each other or to ground. Doing so will
short out the outputs, damage the amplifier, or both.
• Ne pas lier les sorties 1 et 2 des canaux entre elles ou à la terre. Les
sorties pourraient être court-circuitées et/ou l’amplificateur pourrait être
endommagé.
NOTE: The power output of the XPA 1002 and XPA 1002 Plus can be effectively
doubled by bridging the output. A mono source is wired to both the left and
right input while the output is wired for bridged operation. Bridging allows
power to be output at 200 watts into 8 ohms. The minimum load impedance
when bridging is 8 ohms (see the Bridged Mono Output wiring instructions
on page 20).
To wire the stereo audio output connector:
Step 1: Strip and insert the speaker wires into the connector and tighten the
captive screws. Be sure to observe the correct polarity.
XTRA Series Half-Rack Audio Power Amplifiers • Operation16
Page 24
Do not tin the wires!
XPA 2001-70V
XPA 2001-100V
Step 2: Insert the wired connector into the amplifier output and secure the locking
screws on either side.
2
8Ω / 4Ω OUTPUTS
1
CLASS 2 WIRING
JMono audio output receptacle (XPA 2001 series) — Wire the included 2-pole,
5 mm screw lock captive screw connector for mono audio (see the steps below).
Output is designed to power 70 V (XPA 2001-70V) or 100 V (XPA 2001-100V) line
distribution systems and is rated at 200 watts.
NOTES:
• You must use Class 2 wiring for this output to comply with UL requirements.
• On the XPA 2001, the mono audio output receptacle may be labeled one
of two ways (see the mages below). The wiring and function are the same,
whichever way your product is labeled.
70 V OUTPUT
CLASS 2 WIRING
OUTPUT
70V
oror
100 V OUTPUT
CLASS 2 WIRING
OUTPUT
100V
ATTENTION: Do not tie channel output pins to each other or to ground. Doing
so will short out the outputs, damage the amplifier, or both.
To wire the mono audio output connector:
Step 1: Strip and insert the speaker wires into the connector and tighten the
captive screws. Be sure to observe the correct polarity.
XTRA Series Half-Rack Audio Power Amplifiers • Operation17
Page 25
Do not tin the wires!
HPF
Step 2: Insert the wired connector into the amplifier output and secure the locking
100V, XPA 2001 series) — Use a small screwdriver to toggle this
HPF
80 Hz
recessed two-position toggle switch that alternates between Off (no
filtering) and 80 Hz (default). Setting the switch to 80 Hz prevents
the saturation of 70 V and 100 V speaker input transformers by low
frequency signals. Saturation can result in severe distortion of the
80 Hz
OFF
or
OFF
speaker output signal.
NOTES:
• The high pass filter may be safely turned off if it is applied to the source
output signal upstream of the amplifier. Otherwise, it should be left on.
• The high pass filter toggler switch on the XPA 2001 may be labeled one
of two ways. The wiring and function are the same, whichever way your
product is labeled.
Options for the remote control of the XPA amplifiers include the Extron VCM 100 and
VC 50 volume controllers. Third party 10k potentiometer volume controllers can also be
connected to this port.
As shown in the following illustration, pin V (1) on the XPA is a 10 VDC reference voltage.
Pin C (2) is the volume control DC voltage input. The range is 0 to 10 V, where 0 V is mute
and 10 V provides maximum volume. Pin G (3) is ground.
NOTE: All nominal levels are at ±10%.
XTRA Series Half-Rack Audio Power Amplifiers • Operation18
Controlling Multiple Amplifiers with One Volume Controller (XPA 1002, XPA
1002 Plus, XPA 2001 Series)
Multiple XPA 1002, XPA 1002 Plus, and XPA 2001 series units can be daisy-chained so
that one volume controller can simultaneously regulate the volume of all the amplifiers.
NOTES:
• As additional amplifiers are added to the daisy chain, the sensitivity of the
volume potentiometer will change. The maximum volume level (fully clockwise)
will not be affected. However, the effectiveness of the minimum volume level
(fully counterclockwise) in reducing the volume to inaudible levels decreases as
more amplifiers are added to the daisy chain.
• When more than two XPA Half-Rack units are attached to the chain, sound
may be heard even if the levels have been set to their lowest. The muting of the
output can be remedied with a contact closure button attached between the
Vol/Mute and the Ground pin of the first XPA Half-Rack unit in the chain.
To regulate multiple amplifiers with a single volume controller:
1. Attach all three pins of the volume controller to the corresponding pins on the first
XPA Half-Rack unit only — Ground to G (ground), Vol/Mute to C (Vol/Mute),
and 10 V to V (10 V).
2. Use jumper wires to connect the C (Vol/Mute) pins of the first amplifier and each
successive amplifier.
3. Use jumper wires to connect the G (ground) pins of the first amplifier and each
successive amplifier.
XTRA Series Half-Rack Audio Power Amplifiers • Operation19
Page 27
Extron
VCM 100 AAP
10V
VOL/
MUTE
REMOTE
10V50mA
Extron
XPA Half-Rack
daisy chain
REMOTE
10V50mA
REMOTE
10V50mA
G
STANDBY
GCV
10V50 mA
VOL/MUTE
12345
STANDBY
Figure 11. Regulating Multiple Amplifiers with a Single Volume Controller
NOTE: The 10 V pin of the volume controller connects to the first XPA Half-Rack
unit only. There are no jumper wires linking it to subsequent amplifiers.
Bridged Mono Output (XPA 1002, XPA 1002 Plus)
The power output of the XPA 1002 and XPA 1002 Plus can be effectively doubled by
bridging the output. Bridging allows power to be output in mono at 200 watts at 8 ohms.
G
GCV
10V50 mA
VOL/MUTE
12345
STANDBY
STANDBY
G
GCV
10V50 mA
VOL/MUTE
12345
STANDBY
STANDBY
or
NOTES:
• The bridging instructions that follow apply only to the XPA 1002 and XPA 1002
Plus.
• The minimum load impedance when bridging is 8 ohms.
To bridge the output, follow the steps and refer to the diagram below:
1. Unplug the IEC power cord from the power amplifier.
2. Fully attenuate the potentiometers.
3. Wire the output as shown in the following diagram.
4. Wire the input as shown in the following diagram.
5. Connect the IEC power cord and power up the amplifier.
6. Adjust the input levels of channels 1 and 2 identically.
NOTE: See D of Rear Panel Features and Operation on page 13 for more
details.
XTRA Series Half-Rack Audio Power Amplifiers • Operation20
Page 28
100-240V 0.5A, 50-60Hz
T
XPA 1002
LIMITER/PROTECT
SIGNAL
ATTENUATION
1
2
10
12
14
18
26
∞
INPUTS
1
21
2
10
12
8
8
6
6
14
4
4
2
2
0
0
∞
10V 50mA
1
2
G
STANDBY
8Ω / 4Ω OUTPUTS
REMOTE
Balanced Wiring
From
Mono
Source
Un-Balanced Wiring
From
Mono
Source
Levels should be set
identically.
3.5 mm
Captive Screw
5 mm
Captive Screw
Input
1
2
1
2
Amplified
Output
1
o 8 Ohm Minimum
Speaker Load
2
NOTE: During bridged mono output, the + output from channel 1 becomes the
positive terminal and the + output from channel 2 becomes the negative
terminal.
Figure 12. Bridging the Output of the XPA 1002 and XPA 1002 Plus
XTRA Series Half-Rack Audio Power Amplifiers • Operation21
Page 29
Troubleshooting
Amplifier Fails to Exit Standby Mode Promptly
The front and rear panels have LED warning indicators, as described in the following
diagnostic information.
The input channel (channels 1 and 2) Signal LED lights green per indicated input channel
when an input signal is detected.
Power LED
Color
AmberNot litNo output signalNo input detected, verify the
Green or
Amber
AmberLitNo output signalAmplifier has been placed in
AmberLitDC Fault is detected
Signal LED
State
Lit
intermittently
Problem DescriptionProblem Solution
input signal.
If input is present, raise input
level until signal LED lights.
Does not promptly exit
standby mode with
signal present.
on either channel. Unit
does not exit standby.
The output signal level of the
source may be too low to cross
the signal detection threshold
of the amplifier (see amplifier
specifications for details).
Increase the signal level of the
source until the signal LED
lights consistently.
standby mode and output has
been turned off. Check remote
port. DC Fault may have been
detected (see below).
Disconnect power then
disconnect the remote port (if
connected). Next, reconnect
power to the unit to determine
if the unit continues to go
into immediate standby upon
power up. In such a case, the
unit should be serviced.
Amplifier Enters Standby Mode Too Early
The input channel (channels 1 and 2) Signal LED lights green per indicated input channel
when an input signal is detected.
Power LED
Color
Green or
Amber
Signal LED
State
Lit
intermittently
XTRA Series Half-Rack Audio Power Amplifiers • Troubleshooting22
Problem Description Problem Solution
Enters standby mode
early.
The output signal level of the
source may be too low to cross
the signal detection threshold
of the amplifier (see amplifier
specifications for details).
Increase the signal level of the
source until the signal LED
lights consistently.
Page 30
Limiter/Protect LED Warning Indicators
The output channel (channels 1 and 2) Limiter/Protect LED lights red per indicated output
channel as shown in the following diagnostic information.
LED StateProblem DescriptionProblem Solution
BlinksAudio clipping is occurring at the rate
of one blink per clip.
Lights steady The amplifier may be overheating.Determine the reason for the
Output channel leads are shortedCheck speakers and speaker
Reduce the power output to
avoid overdriving the amplifier
and causing clipping.
overheated state and allow the
amplifier to cool. The LED will not
be lit after the amplifier recovers
from the overheated state.
wiring for shorts.
Over Temp Indicator LED
This indicator does not represent a hard failure of the unit. It is meant as a warning that
the amplifier has exceeded the recommended operating temperature for optional product
lifetime.
LED StateProblem DescriptionProblem Solution
Lights steady Amplifier has exceeded the
recommended operating
temperature. The LED turns off after
the amplifier cools down sufficiently.
• Verify that the placement of the
amplifier allows for adequate
ventilation and airflow.
• Avoid placing equipment on top
of the amplifier.
• Verify that the operating
temperature is within the
specified range.
XTRA Series Half-Rack Audio Power Amplifiers • Troubleshooting23
Page 31
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is
returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America,
and Central America:
Extron Electronics
1230 South Lewis Street
Anaheim, CA 92805
U.S.A.
Europe and Africa:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Asia:
Extron Asia Pte Ltd
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Middle East:
Extron Middle East
Dubai Airport Free Zone
F13, PO Box 293666
United Arab Emirates, Dubai
Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical
or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
USA: 714.491.1500 or 800.633.9876 Europe: 31.33.453.4040
Asia: 65.6383.4400 Japan: 81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage
during shipment. Returned units must include the serial number and a description of the problem, as well as the
name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been
advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may
not apply to you.