WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron website,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit
d’une tension électrique dangereuse susceptible de provoquer un choc
électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation,
la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les
informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site
Extron, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind
und die einen elektrischen Schlag verursachen können.
Инструкция по технике безопасности • Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению
электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: www.extron.com,
номер по каталогу - 68-290-01.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der
im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise
zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad de
Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause interference. This interference must be corrected at
the expense of the user.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility,
accessibility, and related topics, see the “Extron Safety and Regulatory Compliance
VoiceLift System with PVS 405D Installation Guide • Contentsv
vi
VoiceLift System with PVS 405D Installation Guide • Contents
Introduction
This section provides an overview of the VoiceLift System and gives instructions for
planning the installation and preparing the site in which the system will operate. It also
provides a listing of the available system kits and their contents. Topics include:
• About this Guide
• About the VoiceLift System
• Application Diagram
• Planning the Installation
• Inventory
About this Guide
This guide provides steps to install and connect each component of the Extron VoiceLift
System. The VoiceLift VLR 102 receiver can be installed in a drop ceiling, a standard
junction box, an octagonal ceiling box, or a wall. It is assumed that the installer has
some knowledge of and experience with audio/video, electrical, or electronic device
installation.
ATTENTION:
• Installation and service must be performed by authorized personnel only.
• L’installation et l’entretien doivent être effectués par le personnel autorisé
uniquement.
• UL listed electrical boxes are recommended.
• Extron recommande d’installer le VLR 102 dans un boîtier d’encastrement
électrique mis à la terre, listé UL.
About the VoiceLift System
The VoiceLift System is a low-power classroom microphone amplication system
that ensures that an instructor can be clearly heard at a comfortable level throughout
the entire room (also referred to as a “soundeld system”). The pendant or hand-held
microphone picks up speech from the instructor or student and transmits it to the
VLR 102 receiver via an IR signal. From the receiver, the signal is sent to an Extron
PoleVault switcher, which amplies and powers speakers to improve the signal-to-noise
ratio to at least +15 dB.
Two types of VoiceLift system are available:
• VLM System — Consists of one or two pendant microphones or one pendant and
one handheld microphone, the IR receiver, and an optional charging station (this kit
can be added to an existing PoleVault system).
• VLS System — Consists of the VLM System kit components, a PoleVault switcher,
and two speakers.
See Inventory beginning on page 9 for more information on kit contents.
VoiceLift System with PVS 405D Installation Guide • Introduction1
Application Diagram
The application diagram below shows a typical classroom installation incorporating the
VoiceLift System.
N
O I
I
UD
A
L
R
N
O I
DE
VI
1
O
DE
I
V
Y
2
PLA
IS
D
UX
A
F
O
E
OF
D
I
V
3
N
O
PC
E
M
4
LU
E
O
V
G
A
M
G
E
I
I
F
T
N
U
O
C
M
s
u
Pl
P
I
4
0
1
LC
TCP/IP
Network
M
VLP 202
Pendant
Microphone
N
O I
DI
U
A
N
I
ER
T
U
MP
O
C
WR
P
E
G
AR
H
Ex
C
t
r
o
n
N
O
G
H
C
/
E
T
MU
OFF/
E
xtr
on
VLC 202
Desktop Charging
Station
Extron
FF 120
Plenum Flat
Field® Speakers
VLR 102
Receiver
xT
GS
PVS 405D
Twisted Pair
Switcher
Figure 1. Typical Classroom Installation
2
VoiceLift System with PVS 405D Installation Guide • Introduction
Planning the Installation
In
Receiver
Before you begin the installation, consider the major factors discussed in the following
sections to ensure that the installation of the VoiceLift System is as smooth and trouble
free as possible and that the result meets the needs of the users. Placement of the
receiver (sensor location) is very important for optimal performance of the VoiceLift
System. Because IR technology requires line-of-sight placement, take into consideration
anything that could affect or block the transmission of the IR signal from the microphone
to the receiver (see Room Considerations on the next page).
5 ft. (1.5 m) to 40 ft. (10.2 m)
Flat Field Speaker
Out
VLR 102
Figure 2. VoiceLift Connections and Signal Path
Receiver Coverage
The VoiceLift receiver has the same room coverage pattern whether it is mounted on the
ceiling or a wall.
PVS405D
PAGING
SENSOR
L
R
VOICELIFT
+V
AUXOVER PVT REMOTE
INPUT 5
L
R
POWER
12V
3A MAX
INPUTSOUTPUT AUDIO OUT
1/2
3/4
HDMI
SIGLINKSIG LINK
PVT IN PVT IN
PVS 405D PoleVault Switcher
VoiceLift
Receiver
VoiceLift
Microphone
AMPLIFIED AUDIO OUT
DO NOT
GROUND
OR SHORT
4/8
SPEAKER
Ω
OUTPUTS
RS-232
TxRxIRSG G
LR
LAN 1 LAN 2 LAN 3
Ceiling or Wall
Figure 3. VoiceLift Receiver Coverage
NOTE: Coverage is dependent mainly on the room environment, but also on the
microphone. You can attain maximum coverage when the batteries are fully
charged. Reception may decrease as the battery drains.
VoiceLift System with PVS 405D Installation Guide • Introduction3
Room Considerations
The following room factors are important to consider when you are planning the
installation of a VoiceLift system:
Interference and noise sources
Infrared and radio frequency noise can reduce the performance of the microphone
system. To minimize noise in the system, avoid mounting the VoiceLift receiver near the
following items:
• Lighting, fluorescent or incandescent — Keep the receiver at least 2 feet
(61 centimeters) away from a light source. Do not place the receiver where light can
shine directly into it.
• Sunlight — Place the receiver at least 6 feet (1.8 meters) away from windows and
skylights. If this is not possible, cover windows and skylights with curtains, blinds, or
other covering options.
• Plasma displays — Avoid placing plasma displays in close proximity to the
microphone system.
• Electrical equipment — Take placement of electrical equipment such as power
lines or supplies, projectors, dimmers, and computers into consideration, as these
could interfere with the IR signal.
• Cellular phones — Keep cell phones at least 2 feet (61 centimeters) away from
both the receiver and the microphone.
• Other IR devices — Take placement of other IR devices such as assistive listening
devices or IR remote controls into consideration, as these could interfere with the IR
signal.
IR
Transmitter
Window
6 Ft.
Blue Jay Graduation
Class of 2009
Anaheim Family YMCA
Children’s Station
Plasma
2 Ft.
VLR 102
Receiver
Ceiling
Lighting
PWR
CHARGEOFF/MUTE/CHG ON
Extron
Extron
Figure 4. Potential Causes of Noise Interference
4
VoiceLift System with PVS 405D Installation Guide • Introduction
Line-of-sight obstructions between microphone and receiver
A clear line of sight between the microphone and the receiver is critical for best
performance. Take the following potential obstructions to the IR signal into consideration
when placing the receiver:
• Movable furniture (such as desks, tables, and podiums)
• Installed furniture (such as bookcases, racks, cabinets, workbenches, and sinks)
• Support pillars
• I-beams
• Projectors
VLR 102
Ceiling
Beams
Receiver
Blue Jay Graduation
Class of 2009
Anaheim Family YMCA
Children’s Station
Extron
PWR
CHARGEOFF/MUTE/CHGON
Extron
Extron
Not Good
Figure 5. Potential Line-of-Sight Obstructions
VoiceLift System with PVS 405D Installation Guide • Introduction5
Reflection
Line of sight from the microphone to the receiver is ideal; however, reection of the IR
signal also plays a part in the coverage for most rooms. For example, if the speaker with
the microphone is facing a screen, the IR signal may reect off the screen surface to
the receiver in the middle of the room. Ideal conditions for reection are light colored,
smooth surfaces (for example, white drywall). Items to consider that may affect reection
include:
• Ceiling type (such as drop, spline, or hard lid)
• Wall type (such as drywall, cement, acoustical panel, or brick)
• Wall coverings (such as wall art, hangings, or dark colored paint)
• Curtains and blinds
• Furniture (such as bookcases or easels)
VLR 102
Extron
Receiver
Good
Extron
PWR
CHARGEOFF/MUTE/CHGON
Extron
Extron
Not Good
Blue Jay Graduation
Class of 2009
Anaheim Family YMCA
Children’s Station
Figure 6. Reflective Surfaces
6
VoiceLift System with PVS 405D Installation Guide • Introduction
Receiver Location
The best location to mount the receiver is on the ceiling in the center of the classroom.
If the receiver is wall-mounted, center it on the wall between 6 feet (1.8 meters) and
12 feet (3.6 meters) from the oor. These locations maximize the coverage and line of
sight to the microphone.
Avoid the corners of the room, alcoves, bays, or sheltered areas that can restrict
coverage. If the ceiling is over 12 feet (3.6 meters) high, consider mounting the receiver
on a pole to reduce the line-of-sight distance to the microphone.
PoleVault A-V Wallplate Location
Screen or White
Potential
VLR 102 IR
Receiver
Locations
TV / VCR / DVD
Inputs
Wall Mount
Board Location
Ceiling Mount
Student Desks
Figure 7. Diagram of a Classroom Installation
Instructor Desk
MLC Controller
Location
Projector and
Switcher
Location
Speaker
Locations
VoiceLift System with PVS 405D Installation Guide • Introduction7
PoleVault Switcher Location
t
The PoleVault switcher can be mounted anywhere in the room, because the volume
controls are on the microphone. However, placing the switcher near the ceiling makes
cabling and upgrading to a full PoleVault system easier.
WARNING: Structural ceiling failure could cause serious injury or death. Check the
structural ceiling to ensure that it can handle a load four times the weight of the
nal setup.
AVERTISSEMENT : Un défaut dans la structure du plafond pourrait provoquer
des blessures graves voire mortelles. Vérier la structure du plafond an de
vous assurer qu’il peut supporter une charge quatre fois supérieure au poids de
l’installation nale.
PVS 405D
Digital PoleVaul
Switcher
PVS 405SA IP
POLEVAULT SWITCHER
PAGING
SENSOR
AUDIO LEVEL ADJUST
PEAK
SENSITIVITY
NORMAL
SIGNAL
VOICELIFT
PEAK
NORMAL
SIGNAL
INPUT
AUDIO
INPUTS
5
AUX
3
4
1
SELECT
2
CONFIG
R
PMK 560
Projector Mount Kit
Figure 8. Mounting a PoleVault Switcher to a Projector Pole
Possible switcher mounting locations include:
• On a desk• Mounted to a wall
• Under a desk• Mounted to a ceiling pole
• In a cabinet• Above a drop ceiling (The PVS 405D is plenum rated.)
8
VoiceLift System with PVS 405D Installation Guide • Introduction
Inventory
The VoiceLift VLS System kit is available in three packaged congurations:
• VLS 1000D: Contains one VLP 102 Pendant Microphone, a VLR 102 Receiver, a
wall charger, and two FF 120 Flat Field speakers.
• VLS 2000D: Contains two VLP 102 Pendant Microphones, a VLR 102 Receiver, a
wall charger, a VLC 102 Charging Station, and two FF 120 speakers.
• VLS 2000DH: Contains one VLP 102 Pendant Microphone, one VLH 102 Handheld
Microphone, a VLR 102 Receiver, a wall charger, a VLC 202 Charging Station, and
two FF 120 speakers.
VoiceLift System with PVS 405D Installation Guide • Introduction9
NOTE: If any items in the VoiceLift System or FF 120 boxes are damaged or missing,
contact the Extron S
contact numbers).
10
VoiceLift System with PVS 405D Installation Guide • Introduction
3
Sales and Technical Support Hotline (see the rear cover for
Installation Tools
Extron recommends the following equipment (not provided) to ensure that the VoiceLift
System is properly installed.
Safety Goggles
Utility Knives
Flashlight
Cable Cutters
Handsaw for
Cutting Drywall
RJ-45 Crimpers and Connectors
Power Drill
3/4-inch Extension Bit for
Drilling Through Fire Breaks
Marker Pen, Pencil
Tools for Terminating Cable
Tape Measure
Screw Driver Set
Stud Finder
Zip Ties
Fish Tape
Vacuum Cleaner
VoiceLift System with PVS 405D Installation Guide • Introduction11
Items Not Included
The following items are not included. However, some or all of them may be needed for
the installation at your particular site.
• Additional length of RJ-45 cabling (CAT 5, 5e, or 6 with T568A or T568B
straight-through cabling)
• Installation hardware (may vary by installation):
• Electrical ceiling box
• Junction box
• Plaster ring
• Raceway
• Bolts for concrete structural ceilings where needed
• Dry wall anchors and screws
• Spare ceiling tiles in case of accidental damage during installation
• Safety wire, lag eye bolts, and strain reliefs
• Heat shrink
• Extension cord
Optional Items
The optional items listed below can be added to or substituted for items in the standard
VoiceLift System kits.
• VLP 202 Pendant Microphone (additional) or VLH 102 Handheld Microphone
• PVS 405D mounting options
• WMK 160 WallVault wall mounting kit
• PMK 560 pole mounting kit
12
VoiceLift System with PVS 405D Installation Guide • Introduction
Installation
Overview
This section provides an overview of the ve stages of installation for the VoiceLift
system and the steps required for each stage.
Stage 1 — Install the VLR 102 Receiver
Choose one of these installation types:
1a. Drop ceiling
c Cut a hole in the ceiling tile (page 17).
c Mount the receiver housing to the ceiling tile (page 17).
c (Optional) Attach a conduit to the back plate if needed (page 17).
1b. Junction box
c Install the junction box (page 18).
c Attach the receiver housing to the junction box (page 18).
c Attach a conduit to the junction box if needed (page 18).
1c. Wall or other hard surface
c Install a raceway if needed (page 19).
c Mark the mounting screw hole locations on the surface (page 19).
c If using a raceway, remove the appropriate knockout in the receiver
housing (page 19).
cMount the receiver housing to the surface (page 20).
1d. Pole
c Attach the pole to the ceiling (page 21).
c Mount the receiver housing to the pole (page 21).
Stage 2 — Install the FF 120 Speakers (VLS Only)
c Cut the ceiling tile (page 23).
c Install the speakers in the drop ceiling (page 23).
c (Optional) Install a seismic safety cable at each speaker location (page 24).
c Terminate the speaker cable for the PVS switcher (page 24).
Stage 3 — Install the PVS 405D Switcher (VLS Only)
cInstall the PoleVault switcher (page 26).
See the PoleVault Systems Featuring the PVS 405D Switcher Installation Guide for the procedures.
VoiceLift System with PVS 405D Installation Guide • Installation — Overview13
Stage 4 — Connect the VLR 102 Receiver to the PoleVault System
c Pull the cables to the receiver (page 29).
c Connect the cables to the receiver (page 29).
c Attach the receiver dome to the housing (page 30).
c Pull the cables to the PoleVault switcher (page 31).
c Connect the cables to the PoleVault switcher (page 32).
Stage 5 — Configure and Test the System
c Set up the microphones (page 33).
c Set the microphone gain and feedback suppressor (FBS) (page 34).
c Complete the installation (page 36).
Installation Procedures
The following sections contain instructions for installing the VoiceLift System. Where
possible, line drawings and photos from an actual installation are used to clarify some of
the steps discussed in the text. Each image has a circled number corresponding to the
step that is being described.
NOTES:
• Additional installation hardware is needed for this installation and should be
supplied by the installer (see Items Not Included on page 12 for a list of items
that you may need).
• Consider optional accessories for this installation (see Optional Items on
page 12 for a list of available accessories, or visit www.extron.com for details).
• See local building standards and codes to verify that the installation will meet
all the regulatory requirements. Observe all local and national building and
safety codes, UL requirements, and ADA Accessibility Guidelines.
• Before beginning the installation, be sure to check the contents of your
VoiceLift packages against the appropriate inventory list, beginning on page 9,
to ensure that you have received all of the necessary components.
VoiceLift System with PVS 405D Installation Guide • Installation — Overview14
Stage 1:
)
Conduit Knoc
Back Plate
Mounting the
Receiver
This stage consists of installing the VLR 102 receiver in a drop ceiling or on a wall.
Receiver Housing and Back Plate
kouts (2)
Figure 9. Receiver Housing and Back Plate
Where it goes: The housing attaches to the receiver dome, and the back plate
mounts to a ceiling tile or a wall.
What it does: Protects the receiver base plate and connectors. The housing
contains knockouts for different sizes of raceways, and the back
plate contains knockouts for a conduit.
Raceway Knockouts (2
Receiver
Housing
Z-bracket and Mounting Screw (for Installation in a Drop Ceiling)
Z-bracket
Figure 10. Z-bracket and Mounting Screw
Where it goes:The mounting screw passes through the receiver back plate, then through the hole in the ceiling tile. The bracket is attached to
the screw on the back of the ceiling tile.
What it does:Fastens the receiver to a tile in a drop ceiling.
Mounting Screw
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 115
Stage 1a: Installing the
VoiceLift Receiver in a Drop
Ceiling (page 17)
Stage 1b: Installing the
VoiceLift Receiver to a Junction
Box (page 18)
Stage 1c: Installing the
VoiceLift Receiver to a Wall
(page 19)
Stage 1d: Installing the
VoiceLift Receiver on a Pole
(page 21)
Figure 11. Diagrams of Stage 1 Mounting Options
NOTE: Observe all local and national building and safety codes to ensure that the
installation meets all regulatory standards.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 116
Stage 1a — Installing the Receiver in a Drop Ceiling
1. Cut a hole in the ceiling tile.
a. Remove the ceiling tile in which the receiver
will be installed.
b. Determine the receiver location, then cut a
hole in the ceiling tile 2 to 3.5 inches (5 to
9 cm) in diameter, using a circular saw (shown
at right) or other type of saw (saws are not
included).
NOTE: This hole should be large enough to
expose the conduit knockout and the hole for
the mounting screw in the receiver back plate,
but it should not exceed the diameter of the
receiver housing (4.75 inches [12.1 cm]).
2. Mount the receiver housing to the ceiling
tile.
a. Insert the ceiling bracket screw through the
back plate (attached to the housing) and the
hole in the ceiling tile.
Cut a hole in the ceiling tile.
Ï
b. Attach the Z-bracket loosely to the screw on
the back side of the ceiling tile.
c. Align the back plate knockout over the hole in
the tile.
d. Tighten the screw to secure the back plate
and the housing to the tile.
3. (Optional) Attach a conduit to the back plate
if needed (see figure 3).
NOTE: Observe all local and national building
and safety codes.
4. Replace the ceiling tile.
Secure the receiver back plate to the ceiling
Ø
tile and the Z-bracket.
Attach a conduit to the back plate if
3
desired.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 117
Stage 1b — Installing the Receiver to a Junction Box
Mounting Screws
x
Plaster
Ring
1. Install the junction box.
• Install the junction or ceiling box (not included)
flush with the mounting surface (follow the
instructions provided with the junction box).
• Use a one-gang plaster ring (Raco772) if the
junction box is larger than one-gang.
WARNING: Improper installation may result
in electrical shock or serious injury. All
electrical installation should be performed
by qualied personnel in accordance with
local and national building codes, re
and safety codes, and local and national
electrical codes.
AVERTISSEMENT :
Une installation
non-conforme peut entraîner un choc
électrique ou des blessures graves. Toute
installation électrique devrait être effectuée
par un personnel qualié, conformément
aux codes du bâtiment, aux codes incendie
et sécurité, et aux codes électriques locaux
et nationaux.
Attach the junction box flush with the
1
mounting surface.
2. Attach the receiver housing to the junction
box.
a. Align the receiver housing with the junction
box.
b. Secure the housing in place with the
appropriate screws (not included).
3. Attach a conduit to the junction box if
needed.
NOTE: Observe all local and national building
and safety codes.
Junction Bo
Mounting
Holes (2)
Ceiling Box
Mounting
Holes (2)
Attach the receiver housing to the junction
Ö
box.
Attach a conduit to the junction box if
3
needed.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 118
Raceway
Stage 1c — Installing the Receiver on a Wall or Other Hard Surface
1. Install a raceway if needed.
If using a raceway for the cables, install it at the
appropriate location on the mounting surface.
NOTE: Raceway knockouts on the receiver
housing fit common types of raceways
such as the Wiremold 500/700 series
and the Wiremold 2400 series. Follow the
instructions provided by the manufacturer
to install the raceway.
Install the raceway (if needed).
1
2. Mark the mounting screw locations on the
surface.
Use the screw holes in the receiver housing
as guides to mark the screw locations on the
mounting surface.
3. If using a raceway, remove the appropriate
knockout in the receiver housing.
a. Use a knife to score around the edge of the
selected raceway knockout to create a clean
edge.
b. Press on the scored section to remove it.
Mark mounting screw locations in the
2
surface.
Knockouts (2)
Remove a raceway knockout from the
3
housing, if needed.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 119
4. Mount the receiver housing to the surface.
If not using a raceway:
Mount the receiver housing and base to the
surface, using the appropriate screws for the type
of surface.
NOTE: Screws and wall anchors are not
included.
If using a raceway:
Position the receiver housing with the raceway
inserted through the knockout.
Mounting without a raceway
4
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 120
Mounting with a raceway
4
Stage 1d — Installing the Receiver on a Pole
1. Attach the pole to the ceiling.
Attach the required length of ¾-inch (19 mm)
diameter electrical metal tubing (EMT) or downrod
to the ceiling.
NOTE: You can use ½-inch tubing for the
pole. However, the RJ-45 connector on the
twisted pair communication cable does not
fit through this size pole. To use tubing this
size, you must remove the connector from
the cable, pull the cable through the pole,
then reterminate the cable.
Example: If desired, you can attach the pole to a
junction box as shown at right.
2. Mount the receiver housing to the pole.
a. Remove a large knockout from the receiver
back plate to accommodate the ¾-inch
(19 mm) pole (see figure Õ at right).
Attach the pole to the ceiling (junction box is
1
optional).
b. Attach a ¾-inch (19 mm) clamp, compression,
or set screw connector to the other end of the
pole (see figure Ö below).
Attach a ¾-inch connector to the pole.
Ö
c. Remove the lock nut from the connector and
insert the connector into the large knockout
space on the metal back plate.
Remove the large knockout (outer ring).
Õ
d. Replace the lock nut onto the connector
and tighten it to secure the connector to the
housing.
–
×
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 121
Attach the pole to the receiver back
Ø
plate.
Stage 2:
T- rails (2)
eet (10.6 m)
Mounting the
FF 20 Speakers
This stage consists of installing and connecting the FF 120 speakers (VLS only).
NOTE: The installation must conform to national and local electrical codes and UL
requirements (see the FF 120 Flat Field Speakers User Guide for details).
FF 120 Flat Field Ceiling Speakers
Speaker Cable
FF 120 Speakers (2)
Seismic Tabs
(1 at each end)
Te rminal Cover
Cable Clamps (2)
Anchor Rings (2)
Figure 12. FF 120 Ceiling Speaker
Where they go: Installed in ceiling tiles at locations selected for best acoustics
What they do: Receive and output the audio signal from the PVS 405D
switcher.
SPK 18, 35 f
Figure 13. SPK 18 Speaker Cable
What it does: For speaker installation, connects the ceiling speakers to the switcher.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 222
Speaker Mounting Procedure
1. Cut the ceiling tile.
See the FF 120 Flat Field Speaker User Guide,
available at www.extron.com, for instructions.
a. Remove the ceiling tiles where the speakers
will be installed.
TIP: For ease of working on the speaker
when it is replaced on the T-frame,
remove the adjacent tiles.
b. Mark a line 12 inches (30 cm) from and
parallel to one of the short edges of the tile.
c. Cut along the line and discard the short part.
TIPS:
• Use a ne hacksaw blade to cut the
tile without damaging the face.
• Place an empty box under the tile for
support and to collect the waste.
2. Install the speakers in the drop ceiling.
a. At the speaker location, lay one of the
supplied T-rails 12 inches (30 cm) from one
end of the T-frame. The speaker will be placed
into the small section.
b. Remove the terminal cover from the rear of a
speaker and attach the anchor ring and cable
clamp to the cover.
Mark a line on the ceiling tile.
Ï
Cut the ceiling tile on the marked line.
Ð
c. Place the speaker onto the T-frame and pass
the speaker cable through the cable clamp.
d. Connect the speaker wires to the terminals:
the red wire is positive (+) and the black
wire is negative (–)
e. Reattach the terminal cover and, if possible,
bend the seismic tabs down over the T-rails.
f. Replace the ceiling tile.
g. Repeat steps 2a through 2f for each speaker
that needs to be installed.
Place the T-rails on the T-frame.
Õ
Remove the terminal cover and attach the
Ö
ring and clamp to it.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 223
3. (Optional) Install a seismic safety cable at
ATTENTION:
• Repeated bending of the tab
may cause it to break off.
• Le fait de plier l’attache de
façon répétitive peut la casser.
Bend Up Tab
Anchor this end to a
suitable secure point.
Route the seismic
line through the
line retainer and
bendout tab.
Seismic
Safety
Cable
Top
Te rminal
Cover
Seismic
Anchor
Ring
Locking
Ring
Cable Clamp
Adapter
each speaker location.
a. Mark, drill, and install a lag eye bolt for the
seismic safety cables (not included) in the
ceiling above the speaker location.
b. Pass the seismic cable through the anchor
ring down to the nearest seismic tab and twist
the end around the cable five times.
c. Pass the other end of the cable up through
the lag eye bolt (see step 3a) and twist that
end around the cable five times.
- Þ Attach the seismic safety cable.
Ý
4. Terminate the speaker cable for the
PVS switcher.
To terminate the cable, strip the end of the cable
0.2 inch (5 mm) and secure the wires into the
supplied 4-pole captive screw connector.
NOTE: The correct speaker impedance
loading must be observed when you are
setting up a speaker system (see figure 14
on the next page for examples).
Speaker 1Speaker 2
Audio Output
to Speakers
4-pole Captive
Screw Connector
AMPLIFIED OUTPUTS
LR
PVS Switcher
Rear Panel
Wire the captive screw connector.
4
4/8
Ohms
Speaker
Wire Color
To PVS 405D
Terminal (Left and
Right)
RedPositive (+)
BlackNegative (-)
4-pole Captive
Screw Connector
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 224
ers
AMPLIFIED OUTPUTS
Stereo or Dual Mono Output Using Parallel Speaker Wiring
FIG_Speaker Wiring Examples
AMPLIFIED OUTPUTS
Dual Mono Output
AMPLIFIED OUTPUTS
Mono +
Mono –
Stereo Output
8
ohms
8 Ohms
LR
8 Ohm Load
Mono +
or
Stereo L+
8
ohms
Mono –
or
Stereo L-
Mono +
Mono –
LR
4/8 Ohms
Stereo L+
Stereo L–
Mono +
or
Stereo R+
Mono –
or
Stereo R-
LR
8
ohms
4 Ohm Total Load4 Ohm Total Load
8 Ohms
Stereo R+
Stereo R–
8 Ohm Load
Two 8 ohm speak
wired in parallel
equal a 4 ohm load.
8
ohms
Figure 14. Speaker Wiring Examples
NOTE: By default, the switcher-amplifier is set for dual mono output. Use the Universal
Switcher Control software or the Extron Special Instruction Set (SIS™) commands to change
the setting to stereo if desired. For full details, see the PoleVault Systems Featuring the PVS 405D Switcher Installation Guide, available at www.extron.com.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 225
Stage 3:
Po
Paging
Installing the
PoleVault Switcher
This stage consists of installing the PVS 405D PoleVault Switcher (VLS only). See the
PoleVault Systems Featuring the PVS 405D Switcher Installation Guide, delivered with
your PVS 405D switcher and also available at www.extron.com, for complete switcher
installation procedures.
PVS 405D PoleVault Switcher
LAN 1 LAN 2 LAN 3
L R
AMPLIFIED AUDIO OUT
4/8
DO NOT
Ω
GROUND
OR SHORT
SPEAKER
OUTPUTS
REMOTE
RS-232
IR
OVER PVT
TxRx
PVS 405SA IP
PAGING
SENSOR
VOICELIFT
R
AUDIO OUT
+V
L
OUTPUT
AUX
R
INPUT 5
INPUTS
L
HDMI
3/4
1/2
SIG LINK SIG LINK
PVT IN
POWER
12V
3A MAX
PVT IN
S G G
Audio Out
Port
Sensor
Port
Output to
Speaker
SIG LINK SIG LINK
POWER
12V
3A MAX
wer Supply
Connector
Figure 15. PVS 405D Switcher, Cable, and Power Supply
Where it goes:The PVS 405D and power supply can be installed in the following locations:
What it does: Receives input video and audio signals from the AV source input
wall plates and audio signals from the VoiceLift VLR 102 Receiver.
Outputs and switches the signals to a projector and ceiling
speakers.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 326
INPUTSOUTPUT AUDIO OUT
1/2
3/4
HDMI
PVT INPVT IN
PVS 405D
PAGING
SENSOR
L
R
VOICELIFT
+V
AUXOVER PVT REMOTE
INPUT 5
L
R
AMPLIFIED AUDIO OUT
DO NOT
GROUND
OR SHORT
4/8
SPEAKER
Ω
OUTPUTS
RS-232
IR
Tx Rx
SGG
LR
LAN 1LAN 2LAN 3
VoiceLift
Receiver Port
• A projector ceiling pole, with an Extron PMK 560 Pole Mount Kit
• A table top, cabinet, or shelf (Attach the four provided rubber
feet to the bottom of the unit.)
• On a wall, with an Extron WMK 160 WallVault Wall Mount Kit
PoleVault Switcher Installation
1. For assistance in selecting a location for the PVS 405D switcher within the room,
see Room Considerations on page 4.
2. Install the PVS 405D, following the instructions in the PoleVault Systems Featuring
the PVS 405D Switcher Installation Guide and the provided mounting kit user guide.
3. Make sure that the PVS 405D front and rear panels are accessible until installation
and testing of the VoiceLift System is complete.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 327
Stage 4:
DIP Switches
Connecting the
Cables
This stage consists of connecting the receiver and speakers to the PoleVault switcher.
Receiver Dome
RJ-45 Connectors
Locking
Tab (4)
Locking Tab
with Arrow
Captive Screw Connectors
Figure 16. Receiver Dome Features
Where it goes: Attaches to the receiver housing.
What it does: Receives signals from the microphone and sends them to the
switcher or amplier. Its top panel contains photodiode IR sensors (inside), captive screw connectors for auxiliary input,
RS-232, contact input, and relay output; RJ-45 connectors for
power, communication, and audio output; and DIP switches.
STP Cable
Figure 17. STP Cable
Use a CAT 5, 5E, 6, 7 screened shielded twisted pair cable with T568A or T568B
straight-through wiring.
Where it goes:Attaches to the receiver RJ-45 Out port and to the VoiceLift Receiver RJ-45 port on the PVS 405D switcher.
What it does:Provides power to the receiver and enables communication and audio between the receiver and the PoleVault switcher.
28
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 4
Procedure
1. Pull the cables to the receiver.
a. Pull the STP cable through the receiver
base, along with any other cables that will be
attached to the receiver (RS-232, STP cable
to a secondary receiver, and so on).
b. If mounting the receiver to a wall and using a
raceway, place the cables in the raceway and
replace the raceway cover.
2. Connect the cables to the receiver.
a. Connect the STP cable to the Receiver Out
port (the RJ-45 connector closest to the DIP
switches on the receiver base).
Pull the cables through the receiver base.
Î
Place the cables in the raceway and replace
Ï
the raceway cover.
Connect the STP cable to the Receiver Out
Õ
RJ-45 port.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 429
2. Connect the cables to the receiver
(continued).
b. Install any optional devices and connect their
cables to the appropriate ports on the receiver
base.
c. If desired, set the Tone DIP switch on the
receiver base:
• Up: Enable the microphone volume
change alert tone (default).
• Down: Disable the microphone volume
change alert tone.
NOTE: The Mix DIP switch should always
be set to Down. Leaving it in the Up
position could cause noise.
3. Attach the receiver dome to the housing.
OUTIN
O
N
CTS-2
12
MIX
TONE
Tx
RS-232
Rx
AUX IN
+
IN
CTC
NO
RLY
C
12
O
N
CTS-2
Base Plate
TONE
MIX
Set the Tone and Mix DIP switches (optional).
Ö
a. Place the dome onto the housing, aligning the
arrow etched on the dome locking tab with
the raised arrow on the housing rim. The two
tabs in the housing should slide into the two
Ta b
Arrow
slots in the base.
Arrow on Housing
Dot
Ta b
Arrow
Receiver
Dome
Arrow on Tab
Twist to
Lock
Align the arrows on the housing rim and the
Ü
Align Arrows
dome tab.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 430
3. Attach the receiver dome to the housing
(continued).
b. Twist the dome to the right (clockwise) until
it locks in place (approximately 1/8 turn). The
dot on the rim of the housing should now
align with the arrow on the dome locking tab.
4.
Pull the cables to the PoleVault switcher.
a. Remove the bottom covers of the PMK 560
projector mount.
b. Pull the cables from the receiver and from
the speakers in VLS systems to the PoleVault
switcher location.
Dot on Housing
Arrow on Tab
The arrow aligns with the dot when the dome
Ý
is in place.
c. Run the cables down through the projector
pole and the PMK mounting bracket.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 431
Audio Output
Receiver
5. Connect the cables to the PoleVault
switcher.
a. Disconnect the power cable from the
PoleVault switcher.
b. Plug the STP cable into the VoiceLift Receiver
RJ-45 port on the switcher.
c. Connect cable from the speakers to the
Amplified Audio Out connector on the
switcher (VLS systems only).
d. Reconnect the power cable to the switcher.
to Speakers
Speaker
Wire Color
PVS Terminal
(Left and Right)
Red Positive (+)
Black
Negative (–)
ìì
PVS 405D
PAGING
SENSOR
VOICELIFT
+V
AUXOVER PVT REMOTE
ëë
AMPLIFIED AUDIO OUT
DO NOT
GROUND
OR SHORT
SPEAKER
OUTPUTS
IR
SGG
VoiceLift
RS-232
Tx Rx
4/8
Ω
LR
LAN 1LAN 2LAN 3
POWER
12V
3A MAX
INPUTSOUTPUT AUDIO OUT
1/2
3/4
SIGLINK SIGLINK
PVT INPVT IN
HDMI
L
INPUT 5
L
R
R
Figure 18. Connecting the Receiver to a PVS 405D Switcher
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 432
Stage 5:
Testing the System
This stage consists of conguring, setting up, and testing the VoiceLift System.
1. Set up the microphones.
Set up each microphone in your VoiceLift system
as follows:
a. Set the channels using the rotary switch. A
and C are at 2.3 MHz, and B and D are at
2.8 MHz.
NOTES:
• Each microphone must be set to a
different frequency; in other words,
only channels A and B, A and D,
B and C, or C and D can be used
together (on the VLH 102 Handheld
Microphone you can select only
channels A and B).
• If the student is using a pendant
microphone, it is recommended
that you disable the volume buttons
by setting the channel to C or D.
This prevents the student from
inadvertently pressing both volume
buttons simultaneously and sending
an instant alert (see Installation
Example — Setting Up an Instant
Alert beginning on page 37).
b. (Pendant microphone only) Apply a Teacher,
Student, Mic 1, or Mic 2 label to the back of
the microphone.
A
B
C
D
ÎÎ
VLP 202 Pendant Microphone
A
B
ÎÎ
A
B
VOLUME
c. Remove the battery cover and insert the
battery.
d. Replace the battery cover.
VLH 102 Handheld Microphone
– Ð Set up the microphone.
Î
33VoiceLift System with PVS 405D Installation Guide • Installation — Stage 5
1. Set up the microphones (continued).
e. Attach the lanyard to the VLP 202 (pendant
microphone only).
i. Press the lanyard into the guides on either
side of the lanyard clip.
Guides on Lanyard Lock
Press lanyard into guides.
Clip
Top View
ii. Press the top of the microphone rear clip
to raise it.
iii. Slide the lanyard lock under the clip and
release the clip.
f. Charge the microphone for 5 hours.
2. Set the microphone gain and feedback
suppressor (FBS).
The VoiceLift feedback suppressor eliminates
feedback from the microphone. Follow these
steps to achieve the best performance from the
FBS:
a. Power on the VoiceLift system. The Power
LEDs on the microphone and receiver should
light green.
If the microphone has been in operation, cycle
power on the receiver to clear any existing
lters.
Lock
Attach the lanyard to the pendant
Ò
microphone.
Power LED
Power Switch
Power LED
Power Switch
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 534
Power on the microphone.
Õ
Set the microphone gain and feedback
counterclockwise.
2.
suppressor (FBS) (continued).
b. Instructor: Place the lanyard with the
pendant microphone around your neck
and adjust the lanyard by sliding it through
the lanyard lock until the microphone is
approximately 4 inches (10.2 cm) below your
chin (see figure
Ö
).
Breakaway
Clasp
Student: Hold the pendant or handheld
microphone approximately 4 inches (10.2 cm)
from your mouth.
c. Turn off all program audio sources.
d. Lower the microphone input gain on the
PoleVault switcher to minimum by turning the
encoder counterclockwise two full rotations.
R
W
P
Extron
N
O
UTE
OFF/M
Instructor: Place the microphone on the
Ö
~ 4 inches (10.2 mm)
Lanyard
lanyard and adjust it.
AUDIO LEVEL ADJUST
INPUT
PEAK
VOICELIFT
NORMAL
SIGNAL
Tu rn the encoder
Lower the input gain on the PoleVault
Ø
PEAK
NORMAL
SIGNAL
PAGING
SENSOR
SENSITIVITY
switcher.
Lanyard
Lock
PVS 405D
POLEVAULT SWITCHER
e. Raise the volume on the VoiceLift microphone
to maximum by pressing and holding the
Volume Up button until the microphone stops
beeping.
f. Slowly raise the microphone gain level
on the PVS switcher while talking into the
microphone until feedback occurs. One click
of the encoder is 1 dB. The dynamic filters
begin to engage and to eliminate feedback. If
the feedback persists, lower the microphone
gain on the switcher until the feedback stops.
g. To set additional filters, walk around the
room while talking into the microphone. If the
feedback persists, lower the microphone gain
on the switcher and walk around the room
again.
NOTE: The highest gain achieved without
feedback is the maximum gain for the
VoiceLift system.
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 535
Volume Up
Volume Up
A
B
VOLUME
Volume Down
– Ú Volume Up and Down buttons on the
Ù
Volume Down
VoiceLift microphone.
h. Lower the volume on the microphone to an
L R
DO NOTGROUNDOR SH
ORT
SPEA
KER
OUTPUTS
4/8Ω
3A MAX
POWER
12V
HDMI
1/2
SIG LINKSIG
LINK
3/4
INPUTS
OUTPUT
AUDIO OUT
PVS 405SA IP
AMPL
IFIED AUDIO
OU
T
PAGING
SENSOR
PVT IN
PVT IN
L
R
AUX
OVER
PV
T
REMO
T
E
VOICELIFT
LAN
1 LAN 2 L
AN 3
INPUT 5
+V
L
R
R
S-232
T
xRx
IR
SG
G
PVS 405D
Switcher
Projector
Pole
Cable Access Slot
Cable Slot
Cover
Power Supply
Power Cord Slot
appropriate level:
• The level of your speaking voice should be
enhanced, but not loud enough to sound
like a paging system.
• Check the LEDs on the PVS switcher. The
green Normal LED should light when you
speak, with the red Peak LED blinking
occasionally.
NOTE: The microphone audio should be
barely audible to the person speaking
into it. Have another person listen for
the audio levels and check for sound
quality.
3.
Complete the installation.
a. Test any optional devices that have been
installed.
b. Complete the mounting and installation of the
PoleVault switcher if necessary.
Level set too high.
PEAK
NORMAL
SIGNAL
Lower input gain.
Level has been
properly adjusted.
Signal threshold
-20 dBV (-18 dBu)
Check the PVS switcher LEDs while lowering
#
the microphone volume.
Complete the mounting of the PVS 405D.
Ý
VoiceLift System with PVS 405D Installation Guide • Installation — Stage 536
Installation
Example — Setting
Up an Instant Alert
This section describes an example of an optional instant alert setup, in which the relay
port of the VLR 102 is connected to a Digital I/O port of an Extron MLC 104 IP Plus. This
enables you to send out e-mail alerts from the classroom by holding down both Volume
buttons for 3 seconds.
1. Connect the receiver to the
MLC 104 IP Plus.
a. Wire one of the provided two-pole
captive screw connectors to one end of a
communication cable as follows:
• Connect the red wire to the NO (Normally
Open) pin.
• Connect the black wire to the C (Common
or ground) pin.
b. Plug the communication cable into the Rly
port on the receiver (see the illustration at
NOTE: If the controller and the switcher use
right.
separate power supplies, ground the common
(C) pin of the Rly port to the receiver using
a jumper between the common pin and the
ground pin on the Contact input (CTC), the
Aux Input (Aux In), or the RS-232 port (see the
illustration at right).
Connect a communication cable to the
Ï
VLR 102 Rly port.
VoiceLift System with PVS 405D Installation Guide • Installation Example
37
1. Connect the receiver to the MLC 104 IP Plus
(continued).
c. Pull the other end of the communication cable
to the MLC 104 IP Plus location.
d. Connect the other end of the communication
cable to one of the direct-insertion Digital I/O
ports on the MLC:
• Insert the black wire into the Ground port.
• Insert the red wire into the first available
Digital I/O port.
2. Configure the MLC 104 IP Plus.
a. Using Global Configurator, configure the MLC
Digital I/O port for digital input with pull-up.
Connect the communication cable to the
Ñ
Digital I/O port of the MLC.
SelectInputWithPull-up.
Õ
b. Configure a monitor to send an e-mail when
the Digital I/O port closes.
NOTE: To configure the MLC, refer to the
Global Configurator help file.
3. Test the instant alert notification.
a. Ensure that the MLC 104 IP Plus is connected
to the network.
b. Press and hold the two Volume buttons on
the microphone simultaneously for 3 seconds.
The receiver LED blinks alternating amber and
green.
NOTE: Ensure the microphone is set for
either channel A or channel B.
c. Check for the arrival of the e-mail notification.
Configure the MLC Digital I/O port for
Ö
digital input with pull-up.
Press and hold both
halves of the Volume
button simultaneously.
A
B
VOLUME
Press and hold
both Volume
buttons
simultaneously.
VoiceLift System with PVS 405D Installation Guide • Installation Example38
Press and hold both Volume buttons for
Ý
3 seconds.
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three
years from the date of purchase. In the event of malfunction during the warranty period attributable directly to
faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or
components, to whatever extent it shall deem necessary to restore said product to proper operating condition,
provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America,
and Central America:
Extron Electronics
1230 South Lewis Street
Anaheim, CA 92805
U.S.A.
Europe and Africa:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
Asia:
Extron Asia Pte Ltd
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical
or mechanical abuse, abnormal operating conditions, or if modications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA
(Return Authorization) number. This will begin the repair process.
USA: 714.491.1500 or 800.633.9876 Europe: 31.33.453.4040
Asia: 65.6383.4400 Japan: 81.3.3511.7655
Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Middle East:
Extron Middle East
Dubai Airport Free Zone
F12, PO Box 293666
United Arab Emirates, Dubai
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or
damage during shipment. Returned units must include the serial number and a description of the problem, as
well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its
quality, performance, merchantability, or tness for any particular use. In no event will Extron Electronics be liable
for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics
has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty
may not apply to you.
Contact Information
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX