Extron electronics VN-Matrix 225 Series Setup Manual

VN-Matrix® 225 • Setup Guide
ab
eg jk
cdfh i
The Extron VN-Matrix 225 Series provides real-time transmission of high resolution audio visual content across standard IP networks for live viewing, collaboration, storage, and playback. The VN-Matrix 225 Series encodes video or graphics sources at resolutions up to HD or WUXGA, streams the video and audio over an IP network, then decodes the content back to the original source resolution. VN-Matrix applies the Extron PURE3™ Codec, a unique wavelet-based compression technology. The VN-Matrix 225 Series offers real-time streaming and low latency, making it ideal for remote collaborative and interactive or control applications. It can be deployed in live event streaming and high level conferencing for specialized projects.
NOTE: For full installation, configuration, and operation details, refer to the VN-Matrix 225 User Guide, at www.extron.com.
Before You Connect to a Network
Before connecting each VN-Matrix to a network you must change its default network settings. On an existing network, check with the network administrator for a range of suitable IP addresses.
On a closed network, used exclusively by VN-Matrix, we recommend that you use addresses in the range 192.168.0.1 to 192.168.0.254 with a subnet mask of 255.255.255.0. The following diagram shows an example addressing scheme for a simple system comprised of four VN­Matrix units:
Controller
IP Address: 192.168.0.101 Subnet mask: 255.255.255.0
LAN-1 LAN-2 STATUS
VN-MATRIX 225 SERIES
RGB/DVI OVER IP
LAN-1 LAN-2 STATUS
IP Address: 192.168.0.102 Subnet mask: 255.255.255.0
VN-MATRIX 225 SERIES
RGB/DVI OVER IP
TCP/IP
Network
IP Address: 192.168.0.103 Subnet mask: 255.255.255.0
LAN-1 LAN-2 STATUS
VN-MATRIX 225 SERIES
RGB/DVI OVER IP
LAN-1 LAN-2 STATUS
IP Address: 192.168.0.104 Subnet mask: 255.255.255.0
VN-MATRIX 225 SERIES
RGB/DVI OVER IP
VN-Matrix Controller
One VN-Matrix device in a group must be designated as the “controller.” All system configuration is achieved via a web interface that is served up by the controller. In the above example, the unit at address 192.168.0.101 is designated the controller for this group of VN­Matrix devices. Note that the controller IP value on each device is set to this address.
Setup Procedure
Follow the step-by-step instructions in the “Initial Setup” section for each VN-Matrix, then follow the “Operation” section instructions to create a simple VN-Matrix system. For more detailed information and advanced setup procedures refer to the user guide.
Rear Panel Features
RS-232
OVER LAN
INDVI-IOUT/LOOP
POWER
12V DC 5A MAX
AUDIO SPDIF
IN
OUT/ LOOP
1 — LAN — 2
TO PCIN
REMOTE
DC power connector — The VN-Matrix 225 requires a 12 VDC regulated power supply (rated at 5A) via this connector. A suitable power supply unit
a
(PSU) is provided.
Digital audio connectors — Use these two female RCA connectors for input or output digital audio signals through S/PDIF coaxial
b
cables.
Network connectors (I and II) — Two female RJ-45 connectors are used to connect the VN-Matrix 225 to an Ethernet network.
c
Typically, port I is used for data streaming and device configuration (using the Web interface). Port II is reserved for future use and special applications.
Peripheral keyboard connector — Connect the keyboard to the PS/2 port.
d
1
VN-Matrix 225 • Setup Guide, cont’d
VN Matrix (R) Maintenance Console: ver3.3c
192.168.0.1 login:
Password:
K
Peripheral mouse connector — Connect the mouse to the PS/2 port.
e
PC keyboard connector — Connect the VN-Matrix 225 PS/2 keyboard port to the PS/2 keyboard port of the PC.
f
PC mouse connector — Connect the VN-Matrix 225 PS/2 mouse port to the PS/2 mouse port of the PC.
g
DVI-I output connector — Connect the computer monitor to this female DVI-I output port.
h
DVI-I input connector — Connect the DVI-I output port of the computer to this female DVI-I input port.
i
Remote serial input-output connector — This male 9-pin port is used to configure the VN-Matrix 225. Connect it to RS-232 (com) port
j
of the PC.
RS-232 over LAN serial input-output connector — This male 9-pin port is used to transmit and receive data across a network.
k
Initial Setup
1. Connect the PC to the 9-pin Remote port
of the VN-Matrix 225.
j
2. To initiate communication between the computer and the VN-Matrix 225, run HyperTerminal from the PC. Set the
communications settings as shown below.
3. Connect the power supply to the VN-Matrix 225
4. After receiving the following “login:” prompt, type config then press the <Enter> key.
a
.
When prompted for Password:, type config then press the <Enter> key. The option menu is displayed.
NOTE: The version of the firmware shown here may not match the version fitted to your Matrix devices.
5. Change the settings as needed by typing the option number and then press the <Enter> key. Next, type in the new
setting and press the <Enter> key.
NOTE: Do not include any extra zeros when typing in IP addresses. For example, type 192.168.0.18; do not type
192.168.000.018.
Once all the changes have been made, type automatically reboot to implement the new settings.
6. Reboot each VN-Matrix 225 once it is connected to the network by inserting
a very small screwdriver or straightened paperclip into the small hole on the front panel just to the left of the LED indicators as shown in the figure.
9 and press the <Enter> key to exit the menu. The VN-Matrix 225 will
Reset Hole
LAN-1 LAN-2 STATUS
VN-MATRIX 225 SERIES
RGB/DVI OVER IP
7. A typical VN-Matrix network includes an Encoder (PC input), a Decoder (display output), and a PC (control). See the
K
following example connection diagram and explanations.
IP Address:
192.168.0.101
POWER
12V DC
AUDIO
5A MAX
SPDIF
VN-Matrix Encoder
IP Address:
192.168.0.102
POWER
12V DC
AUDIO
5A MAX
SPDIF
VN-Matrix Decoder
IN
OUT/ LOOP
1 — LAN — 2
IN
OUT/
LOOP
1 — LAN — 2
TO PCIN
TO PCIN
RS-232
REMOTE
OVER LAN
INDVI-IOUT/LOOP
PC (video source)
å
TCP/IP
Network
REMOTE
RS-232
OVER LAN
INDVI-IOUT/LOOP
Display
Local Monitor Display (optional)
Control PC (web browser control)
ç
a. Connect a video source to the VN-Matrix Encoder as shown above.
NOTE: An optional local monitor may be connected to the Encoder.
b. Connect a video display to the VN-Matrix Decoder as shown above.
c. Connect a PC to the network for control, as shown above.
NOTE: The control computer must be on the same subnet as the VN-Matrix units.
Operation
Once all VN-Matrix 225 devices have been correctly set up, any further system configuration and operation is via the VN-Matrix 225 network interface. Built-in HTML pages provide access to various system parameters. The VN-Matrix 225
device that you designated as the controller in the “ network server. The HTML pages can be viewed by any web browser, such as Mozilla® Firefox®, ver. 1.3 or newer (preferred),
®
or Microsoft
Internet Explorer®, ver. 6.0 or newer.
NOTE: Whichever browser you use must be configured to accept cookies and be Javascript-enabled.
Start up and Login
1. Connect a computer through the network to the VN-Matrix 225 device that is configured as the controller.
2. Enter the IP address of the VN-Matrix 225 unit that is configured as the controller into the address bar of the web
browser.
3. Press the keyboard <Enter> key. The login screen displays.
4. Enter the username and password.
NOTE: The VN-Matrix 225 devices have two user accounts (usernames):
admin — allows full read/write access to all setup parameters
public — allows read-only access to setup parameters As shipped from the factory, the password for both accounts is the same as the user name (the
password is “admin” for the admin user account and “public” for the public account).
• The username and password are case sensitive.
• For the intial setup, use the admin username.
Before you Connect to a Network” procedure functions as the
5. Click the Login button or press the keyboard <Enter> key. The VN-Matrix 225 web page opens to the Device List tab,
shown on the next page. This page lists all VN-Matrix devices that are connected to the system controller.
32
VN-Matrix 225 • Setup Guide, cont’d
ab
eg jk
cdfh i
Congure the VN-Matrix 225 Units as Encoders or Decoders
The Mode column on the Device List tab shows how each VN-Matrix 225 unit is configured using the following icons:
= Encoder = Decoder = Recorder or a playback device = Undefined
NOTE: The VN-Matrix Recorder/Undefined option is not documented here. The device list may show more devices than
are in your system. This is because the controller maintains a list of devices that have been used previously, but may not be currently available. In this case, the IP address entry for that device is blank.
Configure the device as an encoder or decoder as follows:
1. In the device list double-click any of the list entries for a device
to be configured. The following web page displays.
2. In the Device Setup box
create source
encoder or click the create display device as a decoder. See “Device Setup” on the Help tab for more configuration details.
button to configure the device as an
b
3. After configuring the device, set the Mode to enable
and save the configuration by selecting the Save All tab
4. From the Display page of the decoder select an encoder source
device. See the illustration below.
shown to the right, click the
a
button to configure the
c
d
e
.
Local Monitor and Display Messages
NOTE: The following messages may be displayed on the local monitor connected to the decoder.
“No Source Present” An encoder message indicating that
either no source device is connected or it is not compatible with the VN-Matrix 225.
“No Source Datastream” A decoder message indicating that
either no encoder is selected or the chosen encoder is not streaming.
Front Panel LED indicators
The top power LED lights green when the unit
receives power; it flashes green when an over temperature, overload, or underload condition occurs. Cycle the power on and off to reset the unit.
LAN-1 and LAN-2 LEDs indicate the status of the indicated network ports. They light or flash orange to indicate that
data is being transmitted or received; an unlit state indicates no network or data activity.
The Status LED lights green when source data is present but not being streamed (unit disabled or in standby mode); it
flashes green when the source data is being streamed and received; an unlit state indicates that source data is neither detected nor received.
Extron USA - West
Headquarters
+800.633.9876 Inside USA/Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
4
Extron USA - East
Extron Europe
Extron Asia
+800.633.9876
Inside USA/Canada Only
+1.919.863.1794 +1.919.863.1797 FAX
+800.3987.6673
Inside Europe Only
+31.33.453.4040 +31.33.453.4050 FAX
© 2011 Extron Electronics. All rights reserved. www.extron.com
+800.7339.8766
Inside Asia Only
+65.6383.4400 +65.6383.4664 FAX
LAN-1 LAN-2 STAT US
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China
+400.833.1568
Inside China Only
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800 +971.4.2991880 FAX
68-2120-50
Rev. A
06 11
Loading...