P
OWER
12V .5
A
M
AX
INPUT O
UT
P
UT
C SYNC
SOG
C VIDEO
N/C
L
R
AU
D
IO
O
U
T
PUT
AV INPU
T
RGB
P
O
W
E
R
15V
.34A MAX
TP T 15HD
A
H-S
H IF
T
BUFFERE
DCOMPUTER
INPUT
AUDIO
ID PIN 4 ID PIN 11
LOCAL MONITOR
Plasma/LCD Display
Audio
Extron TP T 15HD A
Twisted Pair Transmitter
Extron SEQ 100 15HD
Skew Equalizer
CAT5/5e/6 UTP Cable
Extron TP R 15HD A
Twisted Pair Receiver
PC
INPUT OUTPUT
POWER
12V .5A MAX
GREENRED BLUE
Position Delay Position Delay Position Delay Position Delay
1 2 3
0 ns 3 ns 6 ns 9 ns
5 6 7
10 ns 13 ns 16 ns 19 ns
9 10 11
20 ns 23 ns 26 ns 29 ns
13 14 15
04812 30 ns
33 ns 36 ns 39 ns
This sheet provides quick start instructions for an experienced installer to set up and operate the SEQ 100 15HD Skew Equalizer.
Step 1 — Powering down and mounting
Power off all devices and disconnect them from the power source, then mount/locate the SEQ 100 as desired.
Step 2 — Connecting the input and output devices
Connect an RGB source to the 15-pin HD input connector, and connect an RGB display to the 15-pin HD output connector. See the example application illustration below.
Step 3 — Connecting power
Plug the 12 VDC power supply into the 2-pole captive screw connector.
Step 4 — Adjusting for skew equalization
The skew equalizer provides 3 separate time delay circuits on the red, green, and blue video lines. Each time delay circuit can be adjusted using the three rotary switches, from 0 to 39 nanoseconds, to properly align the red, green, and blue signals on the displayed image. To adjust the skew:
a. Rotate all 3 rotary switches to the zero ( ) position. b. Use UTP cable test equipment or examine the displayed video image with a critical eye
to determine which video signal (red, green, or blue) is most shifted to the left.
N A crosshatch test pattern is ideal dor determining pair skew.
d. Adjust the left-shifted video signal’s rotary switch one step at a time while monitoring
the display. Step the switch until the video signal is properly converged.
N The SEQ 100 cannot shift the rightmost video image to the left.
e. If either of the other signals is misconverged, repeat steps a and b. See the table below
for switch positions.
68-962-50