WARNING:This symbol, ,when used on the product, is
intended to alert the user of the presence of uninsulated dangerous
voltage within the product’s enclosure that may present a risk of electric
shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und
die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA:Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di tensione non isolata pericolosa
all’interno del contenitore del prodotto che può costituire un rischio di
scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di importanti istruzioni di funzionamento
e manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности • Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению
электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
All trademarks mentioned are the property of their respective owners..
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks (®), registered service marks (SM), and trademarks (TM) are the property of RGBSystems, Inc. or
ExtronElectronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause interference.
This interference must be corrected at the expense of the user.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and Regulatory
Compliance Guide on the Extron website.
Conventions Used in this Guide
Notifications
In this user guide, the following are used:
WARNING: Potential risk of severe injury or death.
AVERTISSEMENT : Risque potentiel de blessure grave ou de mort.
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
• Risk of property damage.
• Risque de dommages matériels.
NOTE: A note draws attention to important information.
This guide contains information about the Extron RGB-DVI300, RGB-HDMI300, and
RGB-HDMI300A video scalers and converters with instructions for experienced installers on
how to install, configure, and operate the equipment.
Unless otherwise specified, references in this guide to the “video converter” or “video scaler”
relate to the features or operation of all models. “RGB-HDMI300A” refers specifically to the
scaler with an audio input and “RGB-HDMI300” refers specifically to the scaler without an audio
input. “RGB-HDMI300(A)” refers to both versions of the RGB-HDMI300.
This section provides the following information:
• About the RGB-DVI 300 and RGB-HDMI 300 (A)
• RGB-DVI 300 and RGB-HDMI 300 (A) Features
• RGB-DVI 300 and RGB-HDMI 300 (A) Application Diagram
About the RGB-DVI 300 and RGB-HDMI 300 (A)
The RGB-DVI 300, RGB-HDMI300, and RGB-HDMI300A are analog to digital video converters
with built-in scaling. The scalers accept a single RGB or HDTV component (R-Y, Y, B-Y) input
video signal at any standard RGB or HDTV component resolution, through a female 15-pin HD
connector.
The RGB-HDMI300 and RGB-HDMI300A units are identical except that the RGB-HDMI300A
model has a rear panel, 3.5 mm TRS connector to accept an unbalanced audio signal. The audio
signal is embedded in the HDMI® output.
A single video output at any of a large range of scaled resolutions and refresh rates is provided
through a DVI-I (RGB-DVI 300) or HDMI (RGB-HDMI 300 and RGB-HDMI 300 A) connector.
Input and output settings, picture controls, and advanced settings can be adjusted through the
front panel menu with on-screen display, using the Extron Signal Processing Products Control
Program (SPPCP), or by RS-232, using the Extron Simple Instruction Set (SIS) commands.
RGB-DVI 300 and RGB-HDMI 300 (A) Features
Accept all standard RGB and HDTV YUV inputs — These signals are input via a female 15pin HD connector (see page 4).
Scaling — Input sources are scaled to fit the native rate (or pixel size) of a display device. For a
list of valid resolutions, see the Output Resolutions and Refresh Rates table on page 9.
Multiple output resolutions — These units output an extensive range of DVI (or HDMI)
resolutions (from 640x480 to 1920x1200, including 1080p) and refresh rates (23.98 Hz to 75Hz).
See the Output Resolutions and Refresh Rates table on page 9.
Extended Display Identification Data (EDID) emulation — The video converter emulates
EDID information on the VGA input to ensure the output device produces a signal to match the
requirements of the application.
Auto-Image™ — This feature automatically optimizes the image to the scaled output rate,
eliminating complex setup (see page 16).
Signal Processing Products Control Program (SPPCP) — This Windows® based software
provides a simple and intuitive graphical user interface to adjust input and output signals (see
page 23).
On-screen display menu — The menu options are accessed using front panel controls to
easily adjust input and output signals (see page 14).
RGB DVI 300 and RGB HDMI 300 (A) • Introduction1
Simple Instruction Set commands — RS-232 ports on the front and back panels allow easy
ay
Analog RGHBV Output
configuration and picture adjustment by a host device, using SIS commands (see page 28).
Presets — Sixteen input presets (see page 36) and three user presets (see page 18) make it
easy to save and recall commonly used input sources.
HDMI Data — This feature enables or disables ancillary data that can be embedded within the
HDMI output signal (see page 10). When the data are included in a signal passed to a DVI-only
display, the displayed images can be erratic.
Audio Input (RGB-HDMI 300 A only) — The RGB-HDMI 300 A model embeds audio in the
HDMI output signal (see page 4).
Variable Audio Delay (RGB-HDMI 300 A only) — This feature eliminates “Lip sync” effects by
delaying the audio signal to compensate for video processing by other signal processors and
display devices in the system beyond the RGB-HDMI 300 A (see page 19). The RGB-HDMI300
A automatically adds an audio delay to compensate for internal video processing.
Front panel security lockout — This feature locks all front panel controls to prevent accidental
or unauthorized reconfiguration (see page 14).
Behind flat panel mounting — The compact size allows the unit to be concealed by mounting
it to the wall behind a flat panel display. There are a wide range of mounting options (see Wall
Mounting on page 40).
RGB-DVI 300 and RGB-HDMI 300 (A) Application Diagram
Extron
MVX 128 VGA A
VGA & Audio
Matrix Switcher
Analog RGBHV
RESET
7
or Component
LAN
OUTPUTS
8
5
RS232/RS422
6
REMOTE
3
4
1
OUTPUTS
2
11
1 2 3 4 5 6 7 8
12
9
INPUTS
10
7
8
9 10 11 12
5
6
3
INPUTS
4
1
2
LISTED
1T23
I.T.E.
U S
C
1 2 3 4 5 6 7 8
HD PTZ Camera with
1080i Analog Component
Video Output
Audio
Laptop Computer with
1280x800 Analog
RGBHV Output
DVD Player with
480p Analog Component
Video Output
Extron
RGB-HDMI 300 A
RGB to HDMI Scaler
RS-232
TxRx
HDMI OUTPUT
RGB - HDMI 300 A
RGB/R-Y,Y,B-Y INPUT AUDIO IN
POWER
12V
1.0A MAX
Flat Panel Displ
1080p
1080p HDMI
Digital Signal
PC with 1440x900
Figure 1. RGB-HDMI 300 A Application Diagram
RGB DVI 300 and RGB HDMI 300 (A) • Introduction2
Cabling
14
POWER
w Connector
Exter
(12 VDC, 1.5 A max.)
This section describes how to connect cables to the RGB-DVI300, RGB-HDMI300, and
RGB-HDMI300 A:
• Rear Panel Cabling
• Front Panel Cabling
Rear Panel Cabling
Figure 2 shows the rear panel features of the RGB-HDMI 300 A (upper panel) and RGB-DVI300
(lower panel). The RGB-HDMI300 is identical to the RGB-HDMI 300 A except that it does not
have an audio input (c).
POWER
12V
1.0A MAX
INPUT
RS-232
RGB/R-Y,Y,B-Y
22331
POWER
12V
1.0A MAX
Power input
1
RGB input
2
Audio Input (RGB HDMI 300 A model only)
3
RGB/ R-Y, Y, B-Y INPUT
AUDIO
RGB - HDMI 300 A
RGB - DVI 300
44
DVI-D OUTPUT
Digital output
4
RS-232 connector
5
HDMI OUTPUT
455
Figure 2. RGB-HDMI 300 A (Upper Panel) and RGB-DVI 300 (Lower Panel)
Power input — Connect the 12VDC power supply (provided) to the front panel captive
1
screw connectors.
12V
1.0A MAX
Back Panel
Power Receptacle
DC Power Cord
Captive Scre
Tx Rx
RS-232
Tx Rx
RidgedSmooth
+12 VDC input
– Return
Ground
nal Power Supply
all Devices
Figure 3. Power Supply Connection
RGB DVI 300 and RGB HDMI 300 (A) • Cabling3
ATTENTION:
(R-Y) (B-Y)Y
• Always use a power supply supplied by or specified by Extron. Use of an unauthorized
power supply voids all regulatory compliance certification and may cause damage to the
supply and the end product.
• Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute certification de
conformité réglementaire, et peut endommager la source d’alimentation et l’unité.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The power supply is to be located within the same vicinity as
the Extron AV processing equipment in an ordinary location, Pollution Degree 2, secured
to the equipment rack within the dedicated closet, podium, or desk.
• Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation
dans les espaces d’aération ou dans les cavités murales. La source d’alimentation doit
être placée à proximité de l’équipement Extron dans un emplacement ordinaire soumis
à un degré de pollution de catégorie II, solidement fixé au rack d’équipement d’une baie
technique, d’un pupitre, ou d’un bureau.
• The installation must always be in accordance with the applicable provisions of National
Electrical Code ANSI/NFPA 70, article 75 and the Canadian Electrical Code part 1,
section 16. The power supply shall not be permanently fixed to building structure or
similar structure.
• Cette installation doit toujours être conforme aux dispositions applicables du Code
américain de l’électricité (National Electrical Code) ANSI/NFPA 70, article 725, et du Code
canadien de l’électricité, partie1, section16. La source d’alimentation ne devra pas être
fixée de façon permanente à la structure de bâtiment ou à d’autres structures similaires.
• The length of the exposed wires in the stripping process is critical. The ideal length is
3/16 inches (5 mm). Any longer and the exposed wires may touch, causing a short circuit
between them. Any shorter and the wires can be easily pulled out even if tightly fastened
by the captive screws.
• La longueur des câbles exposés est primordiale lorsque l’on entreprend de les dénuder.
La longueur idéale est de 5mm (3/16inches). S’ils sont trop longs, les câbles exposés
pourraient se toucher et provoquer un court-circuit. S’ils sont trop courts, ils peuvent être
tirés facilement, même s’ils sont correctement serrés par les borniers à vis.
NOTE: Do not tin the wires. Tinned wire does not hold its shape and can become loose over
time.
RGB input — The RGB-DVI 300, RGB-HDMI
2
300, and RGB-HDMI300A accept RGB (RGBHV,
RGBS, RGsB, and RsGsBs) and HDTV component
(YUV) signals. Connect the input signal to the
female 15-pin HD connector on the back of the
scaler.
If necessary, use a BNC to VGA adapter cable (see
figure 4).
Figure 4. BNC to VGA Adapter
Cable
RGB DVI 300 and RGB HDMI 300 (A) • Cabling4
Audio input (only in RGB-HDMI 300 A model) — The 3.5 mm TRS audio input accepts
DVI-D OUTPUT
HDMI OUTPUT
3
unbalanced stereo signals. The audio signal is embedded in the HDMI output signal.
Digital signal output — All models output digital signals. The RGB-DVI300 outputs a
4
DVI-D signal through a female DVI-I connector; the RGB-HDMI 300 and RGB-HDMI 300 A
output an HDMI signal through a female HDMI connector.
Use the female DVI-I connector (RGB-DVI 300) or the female HDMI connector (RGB-HDMI
300 and RGB-HDMI 300 A) to pass the output signal to the display device.
Figure 5. Digital Output Sockets
NOTE: Although the RGB-DVI 300 has a rear panel DVI-I connector, the output signal is
DVI-D (digital only).
For the RGB-HDMI 300, secure the HDMI cable with the LockIt HDMI lacing bracket
provided. Connect a HDMI source device to the HDMI input connector on the
RGB-HDMI 300.
To secure each cable to the unit, attach an Extron LockIt bracket to the unit and secure it to
the cable with a zip tie as follows:
1. Plug the HDMI cable into the panel connection
(see figure 6, 1).
3
2. Loosen the HDMI connection mounting screw
from the panel enough to allow the LockIt
lacing bracket to be placed over it (2). The
screw does not have to be removed.
3. Place the LockIt lacing bracket on the screw
and against the HDMI connector (3), then
tighten the screw to secure the bracket (4).
4. Loosely place the included tie wrap around
the HDMI connector and the LockIt lacing
bracket as shown (5).
5. While holding the connector securely against
the lacing bracket, tighten the tie wrap, then
remove any excess length.
Complete details on LockIt installation are
available in the LockIt HDMI Cable Lacing Bracket Installation Guide at www.extron.com.
3
2
2
11
3
4
4
5
5
Figure 6. Securing HDMI cable
with LockIt Lacing
Bracket
RGB DVI 300 and RGB HDMI 300 (A) • Cabling5
RS-232 (rear panel) — The video scalers accept SIS commands from a host device such as
Pin
Function
RS-232
3 Pin Captive Screw Connector
Male DB9 Connector
(Gnd)
5 Sleeve
Ground ( )
5
a computer running the Extron DataViewer utility or other control system. Control commands
can be sent through this port or the Config port on the front panel (see “Front Panel
Cabling”).
T
Transmit data
x
R
Receive data
T R
xx
x
Signal ground
Figure 7. RS-232 Wiring
This RS-232 port can also be used to provide control by the SPPCP. For more information
about controlling these video scalers, see SIS Commands on page 29 or Signal
Processing Products Control Program (see page 25).
NOTES:
• The wiring in the RS-232 cables must cross over so that the transmit port of the
control device connects with the receive port of the video converter and vice versa.
• Only one serial port can be used at a time. If the front port is in use, the rear captive
screw connector must be disconnected from the computer or other control device.
Likewise, if the captive screw port is in use, the Config port on the front panel must
be disconnected from the computer or other control device.
Front Panel Cabling
To connect the host device to the config port
on the front panel, use the optional Extron
female 9-pin D to 2.5 mm TRS Configuration
Cable. The same port is also used to provide
control using the SPPCP.
The pin configuration is shown in figure 9.
15
Tip
69
2.5 mm TRS Connector
Pin Configuration
Male TRS RS-232
Pin Function
2 Tip Transmit (Tx)
3 Ring Receive (Rx)
Ring
Sleeve
Figure 9. DB9 and TRS Wiring for RS-232 Signal
CONFIG
Figure 8. Front Panel Config Port
RGB DVI 300 and RGB HDMI 300 (A) • Cabling6
Configuration
Total Pixels
T
Lines
Single Line of Analog Video
0.0V (black)
This section discusses the configuration of the scalers using front panel controls and the
on-screen display. It is divided into five topics:
• Terminology
• Front Panel Indicators and Controls
• Configuration Procedure
• Front Panel Menu Controls
• On-screen Menus
Terminology
The figure below shows how many of the settings of a video signal are defined. The active area
is the image seen on the screen. The blanking area is the part of each frame containing no video
information that allows the display device to position the image.
otal
Voltage
Ver tical
Start
Active
Lines
Horizontal
Start
Active Pixels
Blanking Area
Active Area
Single Frame of Video
0.7V (white)
H Sync
Figure 10. Video Frame and Line Definitions
Time
H Sync
RGB DVI 300 and RGB HDMI 300 (A) • Configuration7
Input Signal
Video settings
Signal type — RGB or HDTV component (Y, R-Y, B-Y)
Total pixels — The total number of pixels in a line, including blanking on both sides of the
input active area (active, horizontal sync width, back porch, and front porch). The values can be
adjusted from the default value ±512.
NOTE: The total number of lines per frame, including the blanking above and below the
active area is determined by the input signal and is not user adjustable.
Default values for the detected input resolution for total pixels, active pixels, and active lines are
shown with an asterisk (*) in the on-screen display.
Start — The horizontal start defines the number of pixels in the blanking area to the left of the
active area; the vertical start defines the number of lines above the active area.
NOTE: The vertical and horizontal starts and the active area must be set to frame the active
area of the input signal. If these values are set incorrectly, the scaler may crop trailing
edges (right or bottom) or partially mask the leading edges (left or top).
Active pixels — The number of pixels per line that are inside the active area. The baseline for
the active pixels corresponds to the horizontal resolution of the input signal. The values can be
adjusted from the default value ±512.
NOTE: The active pixels and total pixels adjustments are interactive. Setting one of these
variables may require the other to be adjusted.
Active lines — The number of horizontal lines inside the active area. The baseline for the active
lines corresponds to the vertical resolution of the input signal. The values can be adjusted from
the default value ±256.
Phase — The timing of sampling by the digital scaler. Sampling at the optimum pixel phase
results in a bright, stable output.
NOTE: Total pixels and active pixels must be correctly set before adjusting phase.
EDID Emulation — Emulates EDID on a VGA input to provide timing parameters to a source
such as a PC. To work correctly, each cable and connection between the source and the scaler
VGA input must pass pins 10, 12, and 15. EDID communication is not possible if the input cable
is broken out to BNC cables.
Many VGA sources read EDID only when the device is initially powered on, for example, when a
PC goes through the BIOS POST screen. In these cases, EDID must be set on the scaler before
the VGA source is powered on. By default, the EDID provided by the scaler matches the current
output resolution. Use the EDID SIS command to set a specific EDID other than the current
output resolution.
NOTE: 1920x1080 (also known as 1080p) and 1920x1200 standard blanking PC resolutions
exceed the maximum sampling rate of the scaler (162 MHz). If the standard blanking
version of these rates is applied to the scaler, they are undersampled, leading to soft
output. To overcome this undersampling, set the scaler EDID emulation to 1080p or
1920x1200 before the VGA source is powered on. The scaler EDID provides the source
with reduced blanking times that allow the scaler to sample the input pixel for pixel.
RGB DVI 300 and RGB HDMI 300 (A) • Configuration8
Loading...
+ 35 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.