Extron Electronics RGB 120p User Manual

Specifications
Input Video Signal:
Input Sync Signal:
Output Signal:
Frequency Compatibility:
RGB Video Bandwidth:
Wall Mount Power Supply:
Below is an example of how an RGB 120p may be connected to a computer, through an MBC buffer.
Specifications
..Analog: .5 to 1.2 volts p-p ..ECL: .8 to 1 volt p-p
..Sync on Green (RGsB) ..Sync on Red, Green and Blue (RsGsBs)
..Composite Sync (RGBS) ..Separate H&V (RGBHV)
..Video: .5 to 1 volt p-p
..Horizontal: 15-125 kHz (automatic) ..Vertical: 30-170 Hz (automatic)
..200 MHz (2.1 nS Rise Time)
..115 VAC, 60 Hz to 15 VDC/900 mA
User’s Guide
Workstation
Extron Electronics
1230 South Lewis Street Anaheim, CA 92805
SM
714-491-1500 FAX 714-491-1517 U.S.A.
Local Monitor
MBC Buffer
Extron Electronics, Europe
Beeldschermweg 6C 3821 AH Amersfoort +31-33-453-4040 FAX +31-33-453-4050
The Netherlands
Large Screen Projector
Or
Data Monitor
Extron Electronics, Asia
41B Kreta Ayer Road Singapore 089003 +65-226-0015 FAX +65-226-0019 Singapore
79-04
68-292-01
Rev. C
OUTPUTS
RGB 120 Interface
pp
Installation and Operation
Installation and Operation
Description
The RGB 120p has a Video Bandwidth of 200 MHz and is compatible with any Analog or ECL computer system with a horizontal frequency range of 15-125 kHz. Using Extron MBC Cables and MBC Buffers, the RGB 120p is compatible with VGA, Super VGA, IBM PS/2, MAC, Sun, Silicon Graphics, XGA, XGA-2, DEC and many others. Call Extron or refer to Extron'S Handbook of Computer Interfacing for a complete listing.
Installation (See illustration)
1. Turn off computer and its Monitor.
2. Disconnect local Monitor cable from the computer and connect it to the local monitor port on the MBC buffer.
3. Connect MBC interface output cable to “Analog/ECL” on the RGB 120
4. Connect the MBC Power cable to the RGB 120
5. Connect the MBC’s CPU cable to the computer’s video output.
6. Apply power to the RGB 120 monitor.
Automatic Sync Output— See Sync Output
illustration. The RGB 120 output Sync on the coax cables being used, if they are terminated with less than 1K ohm.
• Sync on Green—Cables on R, G and B only.
• Composite Sync—Cables on R, G, B, and H/HV
(not V).
• Separate H&V Sync—Cables on R, G, B, H/HV and V.
Sync is automatically stripped from the Red,
Green and Blue channels.
p
.
p
.
OUTPUTS
p
will automatically
Rear Panel
ON
(off)
p
, the CPU and
CPU
MBC
Buffer
Display Output
Monitor
Power
Operation
Switch# Position Function
Power LED: Indicates if the RGB 120p is receiving power. Horizontal Center Control: With the H Center switch On/enabled,
the H Center Control [
] shifts the displayed image left or right.
Vertical Center Control: With the V Center switch On/enabled, the
V Center Control [
] shifts the displayed image up or down.
Front Panel
100%
0
V CENTER
50%
PEAK
Level Control: Increases (clockwise) the output video level from .3 to
1 volt p-p. This is similar to a contrast control on a monitor or projector.
Peaking Switch: Selects from three levels of peaking to compensate
for mid and high frequency signal losses due to cable length. This is similar to the sharpness control on a monitor. The 3 switch positions are 0 (for no peaking), 50% peaking and 100% peaking. Select the peaking level for the sharpest image on the display.
Note: Over-peaking will distort the displayed image.
Universal Input: Using E
XTRONS MBC input cables and buffers,
allows viewing on both the computer monitor and large-screen projector/monitor at the same time.
MBC Power Source: Use only to power E
XTRONS MBC buffers.
Termination Switch: 75 ohm video termination for applications with
no local monitor (Sw7, below).
1 ON Does not allow Sync on Green
OFF Normal-Automatic Sync Output Detection
2 ON Removes serration pulses
OFF Normal-serration pulses passed through
3 ON Vertical Sync Width (500 µs)
OFF Normal-Vertical Sync Width (150 µs)
4 ON Negative Sync at all times
OFF Normal-Sync output polarity tracking
5 ON No Sync Processing (disables center controls)
OFF Normal-Sync Processing
6 ON Separate H and V Sync at all times
OFF Normal - Automatic Sync output selection
7 ON 75 ohm Input termination (no local monitor)
OFF High Z Input termination (with local monitor)
1
Extron • RGB 120p Interface • User’s Guide
Extron • RGB 120p Interface • User’s Guide