Flexible Conduit Kit Installation Guide
The Extron® Flexible Conduit Kit for is a 6-foot (1.8 m) length of electrical conduit with three
7.5-foot (2.3 m), 14-gauge power wires connected to a mounting plate compatible with
Extron Cable Cubby®. The kit provides a simple means to replace the permanent or IEC power
cord of the Extron Cable Cubby with conduit where required by local codes.
UL Guidelines
The Underwriters Laboratories (UL) guidelines listed below pertain to the installation of the
flexible conduit kit into an Extron Cable Cubby.
WARNING: Installation and service must be performed by a qualified electrician only.
1. This unit is not to be used beyond its rated voltage range.
2. This unit must be wired to a UL-listed distribution box. The installer is responsible for obtaining and installing the box.
3. This unit must be installed in accordance with the National Electrical Code and with all local codes.
Removing the Old Cable
NOTE: If the power box is installed in a Cable Cubby, remove the Cable
Cubby from the table in which it is installed, if necessary, and
remove the power box from the Cable Cubby. See the Cable
Cubby User’s manual.
US/Domestic power boxes have power cords that are
permanently connected to the power box.
International power boxes have standard IEC power
connectors.
1. Unplug any device(s) plugged into the Cable Cubby power box and
disconnect power.
2. Remove and retain the four Phillips head screws on the side of the
power box and remove the side plate (shown at right).
3. Remove the two Phillips head screws on the power input connector
plate on the back (bottom) side of the power box and gently pull the
plate back as far as the wires inside the power box will allow (below right).
4. Cut the cable exiting the power input connector plate as indicated at
right.
• US/Domestic power box — Extend the power cord and cut it
about 8 inches (20 cm) from the front of the power box.
NOTE: Ensure that you cut the power cord after the point
where the separate wires from the front plate outlets
are joined in heat shrink.
• International (IEC) power box — Extend the power cord and cut
the wires as close to the back side of the power IEC connector as
possible.
5. Strip away 1.5 inches (3.8 cm) of the outer jacket (US/Domestic power
box) and 0.5 inches (1.3 cm) of the individual wires’ insulation.
6. Gently pull the three cut wires out of the side of the power box.
Remove 4 scre
and side plate.
Remove the power input
plate.
Remove 2 screws.
1
Flexible Conduit Kit Installation Guide (Continued)
Installing the Replacement Cable
1. Place the conduit plate from the Flexible Conduit Kit on the bottom side
of the power box. Insert the provided Philips head screws through the
conduit plate and engage the threads on the screws with the threaded
holes in the power box.
NOTE: If necessary, reorient the conduit nut and wires for the best
fit.
2. Tighten the screws to secure the conduit plate in place.
3. Twist together the two supply (blue) wires (one from the power outlets
and one from the conduit assembly), the two return (brown) wires, and
the two ground (green/yellow) wires in the power box. Twist one of
the provided wire nuts onto each twisted pair.
4. Use the provided tie wrap to bundle the
power cables.
5. Gently tuck the power cables and wire
nuts into the power box.
Install the conduit
connector panel.
6. Place the side plate on the power box and
secure it in place with the Phillips head
screws removed in Removing the Old
Cable, step 2, on the previous page.
NOTE: If the power box was installed
in a Cable Cubby, reinstall
the power box into the Cable
Cubby and, if necessary,
reinstall the Cable Cubby in the
table. See the applicable Cable
Cubby User’s Manual.
WARNING: Ensure power is removed from the UL-listed AC
distribution box before connecting the power cable
and conduit. Lethal voltages are present in the AC
distribution box.
7. Remove power from the AC distribution box.
NOTE: Ensure the AC distribution box is rated for and equipped with
a 15-amp circuit breaker.
8. Wire the free end of the AC power cable and conduit into the AC distribution box.
Replace 4 screws
and side panel.
Extron USA - West
Headqu arters
+80 0.633 .987 6
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517 FAX
Extron USA - East
+80 0.633 .987 6
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797 FA X
Extron Europe
+80 0.398 7.6673
Inside Europe Only
+31.33. 453. 404 0
+31.33. 453. 4050 F AX
Extron Asia
+80 0.7339 .8766
Inside Asia Only
+65.6 383 .440 0
+65.6 383 .466 4 FAX
© 2010 Extron Electronics. All rights reserved.
Extron Japan
+81.3.3 511.7655
+81.3.3 511.7656 FA X
Extron China
+40 0.88 3.1568
Inside China Only
+86. 21.376 0.1568
+86. 21.376 0.1566 FAX
Extron Middle East
+971.4. 299 1800
+971.4. 299 1880 FA X
68-734-01
Rev C
04 10
2