Extron Electronics Extender Plus Setup Guide

a
a
Extender Plus Series • Setup Guide
ATTENTION: Potential Damage to Property. Installation and service must be
performed by authorized personnel only. These products must be used with UL approved, grounded electrical boxes.
Step 1
Configure EDID Minder at the display device. The Extender Plus models offer two ways of conguring EDID:
• EDID Record — Enables the device to record EDID
directly from a display.
1. Turn the rotary switch (a) to position 0.
NOTE: The DIP switch positions have no
effect in this mode.
2. Apply power to the Extender by connecting the
12 VDC power supply. The green LED (b) lights when power is available.
3. Connect the display device to the input of the Extender using a VGA cable.
4. Power on the display device.
5. Press and release the recessed EDID store button (c). The LED ashes red while
storing the EDID, then it turns solid green when the EDID data has been stored. The display can now be disconnected.
STORE
3
2
EDID
4
aa
SELECT
50
D
B
E
A
F
9
Hz
60
0
8
1
7
2
6
3
5
4
NOTE: If an external supply was used for recording, it can now be disconnected.
• Pre-programmed EDID — The Extender Plus models contain pre‑programmed EDIDs with
the most common display native resolutions for both 50 and 60 Hz.
1. See Table 1 on page 9 of the Extender Plus Series User Guide to see which
resolution corresponds to each rotary switch (a) position. Set the rotary switch to the native resolution of the display.
2. Set the rst DIP switch (d) to the vertical refresh frequency of the display (default is
ON, 60Hz).
Step 2
Turn all of the equipment off and disconnect the power cords from the power source.
Step 3
Select the installation location and install the electrical wall box. See Installation Instructions on page 2 of the Extender Plus Series User Guide for details on installing the
wall box and cables.
NOTE: The Extron Extender Plus AAP does not require a wall box if it is installed into an
Extron HSA 400 Series or HSA 800 Series surface access product.
Step 4
Attach and wire the cables as shown in the image below. The Extender Plus D has the same
circuit board configuration. See “Rear Panel Features and Cabling” in the Extender Plus Series User Guide for more details.
NOTE: If the Extender Plus AAP is installed in an Extron HSA 400 Series or 800 Series
surface access product, install the Extender into the faceplate before attaching the cables.
CAUTION
For unbalanced audio, connect the sleeve(s) to the ground contact. DO NOT connect the sleeve(s) to the negative (-) contacts.
SELECT
D
E
F
C
EDID
B
0
A
1
60
9
2
8
3
7
4
6
5
Hz
EXTENDER Plus D
COMPUTER
OUT
NOTE: Horizontal sync = black
Vertical sync = yellow
GAIN
HIGH
NORM
MED
AUDIO OUT
L R
ON
50
POWER
1 2
STORE
Left Ring
Left Tip
12V
0.2 A MAX
Right Tip
Sleeve (s)
Right Ring
Power
12 VDC
R
Audio
L
Unbalanced Output
R
Audio
L
Balanced Output
Do not tin the wires!
NO Ground Here
Right Tip Sleeve (s)
NO Ground Here
Left Tip
Audio
Right Ring Right Tip Sleeve (s) Left Ring Left Tip
Step 5
Connect power and turn the equipment on.
Step 6
GAIN
NORM
MED
HIGH
Test the system and set the gain switch. Ensure that all devices receive power. Check and adjust cabling and gain as needed.
Gain Switch
(viewed
from front)
Step 7
Disconnect power from all the devices.
Step 8
Mount the line driver into the electrical box or the Plus AAP model into the body of the HSA. For the Extender Plus D, install the Decora® faceplate.
Step 9
Restore power to the devices.
Extron USA Headquarters Extron USA - West Extron USA - East +800.633.9876 (Inside USA/Canada Only) +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX
© 2012 Extron Electronics All rights reserved. www.extron.com
68‑2320‑50
Rev. A
09 12
Loading...