Extron Electronics Extender User Manual

User’s Manual
Extender Series
VGA –UXGA Line Drivers With Audio
68-552-01 Rev. K
02 09
Precautions
Safety Instructions • English
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
Caution
Read Instructions • Read and understand all safety and operating
instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future
reference.
Follow Warnings • Follow all warnings and instructions marked on the
equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not
recommended by the equipment manufacturer because they may be hazardous.
Consignes de Sécurité • Français
Ce s ymbole s ert à a vertir l ’utilisa teur qu e la documentation fournie avec le matériel contient des instructions importantes concernant l’exploitation et la maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de
sécurité et d’exploitation avant d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de pouvoir
les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et consignes
marqués sur le matériel ou présentés dans la documentation utilisateur.
Eviter les pièces de xation • Ne pas utiliser de pièces de fixation ni d’outils
non recommandés par le fabricant du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dies es Sym bol so ll dem Benut zer in der i m Li efe rum fan g e nth alt ene n Do kum ent ati on besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen , daß im I nneren des Gehäuses d ieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden,
sollten Sie alle Sicherheits-und Bedienungsanleitungen genau durchlesen
und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit
des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf
zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und
Anleitungen auf dem Gerät oder in der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte,
die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Instrucciones de seguridad • Español
Este símbolo se util iza para advertir al usuario sobre instruc ciones importantes de ope ración y mantenimiento (o cambio de partes) que se desean destac ar en el c ontenido de la docume ntación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de operación y
seguridad, antes de usar el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad para
futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones marcadas
en el equipo o en la documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no
sean especificamente recomendados por el fabricante, ya que podrian implicar riesgos.
Warning
Power sources • This equipment should be operated only from the power source
indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all power
cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to be
stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-
serviceable parts inside. To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are
provided to prevent overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly
replaced. Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation
indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger,
déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de
manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-
maintenance par un technicien qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orices • Si le boîtier de l’appareil comporte des fentes ou des orifices, ceux-ci
servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d’explosion s’ll y a remplacment incorrect de la batterie.
Remplacer uniquement avec une batterie du meme type ou d’un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene
Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte
Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese
sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen, sollten
Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht im
Weg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbar
dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualiziertem Servicepersonal
durchgeführt werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist,
dienen diese zur Vermeidung einer Überhitzung der empndlichen Teile im
Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt
wird. Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo
de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la acometida
de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben
instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal
calificado. En el interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento,
es para evitar el sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición
incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías usadas siguiendo las instrucciones del fabricante.
安全须知 中文
这个符号提示用户该设备用户手册中 有重要的操作和维护说明。
这个符号警告用户该设备机壳内有暴
露的危险电压,有触电危险。
注意
阅读说明书 用户使用该设备前必须阅读并理
解所有安全和使用说明。
保存说明书 • 用户应保存安全说明书以备将来使
用。
遵守警告 • 用户应遵守产品和用户指南上的所有安
全和操作说明。
避免追加 • 不要使用该产品厂商没有推荐的工具或
追加设备,以避免危险。
警告
电源 该设备只能使用产品上标明的电源。 设备
必须使用有地线的供电系统供电。 第三条线 (地线)是安全设施,不能不用或跳过。
拔掉电源 • 为安全地从设备拔掉电源,请拔掉所有设备后
或桌面电源的电源线,或任何接到市电系统的电源线。
电源线保护 妥善布线, 避免被踩踏,或重物挤压。 维护 所有维修必须由认证的维修人员进行。 设备内部没
有用户可以更换的零件。为避免出现触电危险不要自己 试图打开设备盖子维修该设备。
通风孔 • 有些设备机壳上有通风槽或孔,它们是用来防止
机内敏感元件过热。 不要用任何东西挡住通风孔。
锂电池 • 不正确的更换电池会有爆炸的危险。 必须使用与
厂家推荐的相同或相近型号的电池。 按照生产厂的建 议处理废弃电池。
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
N
This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used
with the unit to ensure compliance with FCC emissions limits.

Table of Contents

Chapter OneIntroduction ................................................... 1-1
About this Manual ....................................................................1-2
About the Extender Series VGA Line Drivers ...................1-2
Differences between the models .......................................... 1-2
Features .................................................................................. 1-3
Chapter TwoInstallation ..................................................... 2-1
UL Guidelines .............................................................................. 2-2
Installation Instructions ...........................................................2-2
Preparing the Site and Installing the Wall Box ................ 2-2
Considerations .......................................................................2-2
Procedure ................................................................................ 2-3
Front Panel Features and Cabling ........................................ 2-6
Top/Rear/Bottom panel Features and Cabling ................. 2-9
Mounting the Extenders ....................................................... 2-14
Mounting the Extender AAP or Extender AAP EX
into an AAP wall plate or device faceplate ........................ 2-14
Pre-installation testing/troubleshooting ...........................2-16
If the image does not appear or there is no sound ...........2-16
If the image is not displayed correctly ................................2-16
Mounting the Extender WM, Extender WM AAP,
or Extender WM AUS to the wall box ................................ 2-17
Mounting the Extender D ...................................................2-18
Mounting the Extender MK to the knockout box ............. 2-19
Application Diagrams ............................................................. 2-20
PRELIMINARY
Appendix AReference ..........................................................A-1
Specications ..............................................................................A-2
Ordering Information ...............................................................A-7
Accessories ...................................................................................A-7
Mounting accessories ............................................................A-7
Cables......................................................................................A-8
Dimensions ..................................................................................A-9
Extender AAP and Extender AAP EX dimensions ................A-9
Extender WM dimensions ...................................................A-10
Extender WM AAP dimensions ...........................................A-11
Extender WM AUS dimensions ...........................................A-12
Extender MK dimensions ....................................................A-13
Extender Series • Table of Contents
TOC-i
Table of Contents, cont’d
Extender AKM UK dimensions ............................................A-14
Extender AKM MAAP dimensions ......................................A-15
Extender D dimensions ........................................................A-16
Templates ...................................................................................A-17
Extender WM template .......................................................A-17
Extender WM AAP template ...............................................A-18
PRELIMINARY
All trademarks mentioned in this manual are the properties of their respective owners.
Extender MK template ........................................................A-19
Extender WM AUS template ...............................................A-20
68-552-01 Rev. K
02 09
TOC-ii
Extender Series • Table of Contents
Extender Series
Chapter One
1
Introduction
About this Manual
About the Extender Series VGA Line Drivers
Introduction

About this Manual

This manual contains information about the Extron Extender series line drivers, and on how to operate and congure them. “Extender” or “line driver” are used to refer to all models interchangeably when instructions apply to more than one model.
PRELIMINARY

About the Extender Series VGA Line Drivers

The Extron Extender Series are one-input VGA–UXGA line drivers with audio. There are nine models in the series:
• Extender AAP
• Extender AAP EX
• Extender WM
• Extender D
• Extender WM AAP
• Extender WM AUS
• Extender MK
• Extender AKM UK AAP
• Extender AKM MAAP. They boost the video signal between a laptop or desktop
computer and a monitor or projector. Each has a 300 MHz (-3 dB) video bandwidth.
Each line driver accepts one computer-video input and one stereo audio input. Each Extender also features one buffered VGA-type RGB output and one stereo audio output. With an optional Mac/VGA adapter, the Extender can also buffer Macintosh signals.

Differences between the models

All Extender models are functionally identical but they have different mounting options.
For details about mounting the Extender AAP, Extender WM, Extender D, Extender WM AAP, Extender WM AUS, and the Extender MK, see “Preparing the Site and Installing the Wall Box” in chapter 2.
For Extender AAP EX mounting instructions, refer to the user’s manual or installation manual for the appropriate model of HSA Hideaway Surface Access enclosure.
For Extender AKM UK AAP mounting instructions, refer to the AKM UK Series Installation Guide, available at
http://www.extron.com.
1-2
Extender Series • Introduction
For Extender AKM MAAP mounting instructions, refer to the Extender AKM MAAP Installation Guide, available at
http://www.extron.com.

Features

Video signal boosting — The selectable gain/peaking settings
Sync restoration — Each Extender restores low level sync
Audio buffering — Unbalanced stereo audio inputs can be
PRELIMINARY
boost video signals to compensate for signal degradation caused by long cables. The Extender can send a high resolution signal up to 250 feet (75 m) through Extron’s M59 Series mini high resolution cable.
voltages found on many laptop PCs (as low as two volts) to normal TTL levels.
output as balanced audio for long cable runs.
Extender Series • Introduction
1-3
Introduction, cont’d
PRELIMINARY
1-4
Extender Series • Introduction
Extender Series
Chapter Two
2
Installation
UL Guidelines
Installation Instructions
Preparing the Site and Installing the Wall Box
Front Panel Features and Cabling
Top/Rear/Bottom panel Features and Cabling
Mounting the Extenders
Application Diagrams
Installation
C
Installation and service must be performed by authorized personnel only. This product should be used with a UL approved electrical box. See “UL Guidelines”, below.

UL Guidelines

1. The Extender must be installed in an Underwriters
PRELIMINARY
Laboratories (UL) listed junction box. The UL approved electrical wall box (junction box) is not included with the unit; the installer is responsible for obtaining and installing the box.
2. The unit must be installed with accordance with the
National Electrical Code and with local electrical codes.

Installation Instructions

Depending on the model, the Extenders can be mounted into furniture, a wall, an Ackermann oorbox, or an Extron HSA 400 Series or HSA 800 Series enclosure.
For Extender AKM UK AAP mounting instructions, refer to the AKM UK Series Installation Guide.
For Extender AKM MAAP mounting instructions, refer to the AKM MAAP Installation Guide.
C
For Extender AAP EX mounting instructions, refer to the user’s manual or installation manual for the appropriate model of HSA Hideaway Surface Access enclosure.
N
The Extender must be installed in a UL listed wall box,
which the installer is responsible for obtaining.
The Extender AAP EX does not require a wall box if
it will be installed into an Extron HSA 400 Series or HSA 800 Series surface access product. If you install an Extender AAP EX without an HSA, you must use a wall box.

Preparing the Site and Installing the Wall Box

Considerations

Choose a location that allows cable runs without interference. Allow enough depth for both the wall box and the cables. You may need to install the cables into the wall, furniture, or conduits before installing the line driver.
• The Extender AAP or Extender AAP EX can be installed
in an Extron two-gang, four-gang, or half rack width AAP Architectural Adapter Plate or in the faceplate of another Extron device that accepts AAP plates, such as an interface
2-2
Extender Series • Installation
or distribution amplier. Refer to the mounting instructions for the adapter plate or device.
• The Extender AAP EX is usually installed into an
HSA 400 Series or HSA 800 Series surface access enclosure.
• The Extender WM can be installed in a standard or compact
one-gang electrical wall box. This is also true for the Extender D, though it requires a standard Decora©-style wall plate.
• The Extender WM AUS can be installed in a standard or
compact Australian one-gang electrical wall box.
• The Extender WM AAP can be installed in a three-gang wall
box, and its faceplate accepts up to four single height Extron Architectural Adapter Plates (AAPs).
• The Extender MK can be mounted into a standard, shallow
knockout switch box (also known as a KO box or MK box) that is used in Singapore, the United Kingdom, and Australia.
The installation must conform to national and local electrical codes and to the Extender’s size requirements. Dimensional drawings and templates are provided in the appendix.

Procedure

1. Refer to the template that corresponds to the Extender
N
2. Mark the guidelines for the opening on the wall or furniture.
3. Cut out the material from the marked area.
4. Check the opening size by inserting the wall box (if used)
5. Feed cables through the wall box punch-out holes, and
6. Exposed cable shields (braids or foil) are potential sources
PRELIMINARY
model and wall box being used.
The templates are not shown at full size. Pay attention to
the measurements shown on the templates.
If the Extender will be installed in a wall box, place the box against the installation surface and draw a line on it around the outside of the box.
If the Extender will be installed without a wall box (using mud rings or fastening it directly to the wall or furniture), measure and mark the surface for the cutout area indicated in the template.
or the Extender (if no box is used) into the opening. The box and line driver should t easily into the opening. Enlarge or smooth the edges of the opening if needed.
secure them with cable clamps to provide strain relief.
of short circuits. Trim back and/or insulate shields with heat shrink.
Extender Series • Installation
2-3
Installation, cont’d
Connecting Shields.eps
Metal Wall Box
Screw
Braided Shield
Install Cable
Foil Shield
Cable Clamp
1-gang wall box.eps
Installation Cable
Cable Clamp
Wall Stud
Installation Cable
Cable Clamp
Wall Stud
Screws or NailsScrews or Nails
PRELIMINARY
Grounding outer braided and foil shields
W
To prevent short circuits, the outer foil shield can
be cut back to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable.
7. Insert the wall box into the opening, and attach it to the
wall, stud, or furniture.
For the Extender WM, Extender WM AAP, Extender WM AUS, Extender D, and the Extender AAP or Extender AAP EX (if installed in a two- or four-gang AAP plate), attach the wall box to the wall stud or furniture with nails or screws, leaving the front edge ush with the outer wall or furniture surface. See the following illustration, which applies to one-, two-, three-, and four-gang wall boxes.
2-4
Attaching a wall box to a wall stud
Extender Series • Installation
Pull mounting tab forward.
If attaching the wall box to wood, use four #8 or #10
screws or 10-penny nails. A minimum of ½" (1.3 cm) of screw threads must penetrate the wood.
If attaching the wall box to metal studs or furniture,
use four #8 or #10 self-tapping sheet metal screws or machine bolts with matching nuts.
For the Extender MK, pull the knockout box’s mounting tabs forward to secure them against the back side of the wallboard or furniture as shown in the following illustration.
Securing the MK knockout box to a wall or furniture
PRELIMINARY
8. Set the gain switch, and cable and test the line driver
before fastening the line driver into the wall box. The switch and cables will be inaccessible after installation. See “Top/Rear/Bottom Panel Features and Cabling” in this chapter for details.
Extender Series • Installation
2-5
Installation, cont’d
EXTENDER AKM MAAP
AUDIO IN COMPUTER IN
EXTENDER MK
COMPUTER IN
AUDIO IN
EXTENDER WM AUS
COMPUTER IN
AUDIO IN
1
2 3
1
4
2 3 1 4
6
Jack Screw Nuts

Front Panel Features and Cabling

PRELIMINARY
Faceplate screws — These secure the
a
faceplate to the rest of the line driver. Faceplate dimensions are provided in the appendix of this manual.
N
To replace the standard faceplate with a customized faceplate:
1. Set the line driver in an accessible place (do not do this while
2. Fasten the new faceplate to the line driver with the
3. Reattach the jack screw nuts.
Power/signal LED — This LED lights
b
amber to indicate that the Extender is receiving power
green to indicate that an active sync signal is present at the input
N
2-6
Extender Series • Installation
Do not remove these faceplate screws or the jack screw nuts on
either side of the PC Input connector while the line driver is attached to the wall. If these screws are removed, the detached line driver may fall down inside the wall.
the line driver is installed in a wall or furniture), and remove the faceplate screws and the jack screw nuts on either side of the PC Input connector.
faceplate screws.
and the Extender is receiving power
The LED remains lit amber when the input signal is HDTV
component video, RGsB, or RsGsBs.
EXTENDER
COMPUTER IN
AUDIO IN
1
1
EXTENDER AKM UK AAP
AUDIO IN
COMPUTER IN
EXTENDER WM AAP
AUDIO IN
EXTENDER WM
COMPUTER IN
AUDIO IN
COMPUTER IN
COMPUTER IN
AUDIO IN
2
3
4
2 3
1
1
4
5 1
1
2 3
4
Sleeve ( )
Ring (R)
Tip (L)
3.5 mm Stereo Plug Connector
(unbalanced)
PRELIMINARY
Audio input connector
c
Plug a 3.5 mm stereo plug into this jack for unbalanced audio input. Wire the male plug as shown in the gure at right.
RGB video input connector
d
(Computer In) — Attach a cable from the computer to the Extender via this female 15-pin HD connector.
Opening for Architectural Adapter Plates (AAPs) — The
e
Extender WM AAP can have up to four optional adapter plates attached here at one time. The Extender AKM UK can hold up to three optional adapter plates at one time. The adapter plates allow for a variety of types of audio/video connectors or another device such as the Extender AAP to be added to the faceplate.
Blank plates are included with the Extender WM AAP, Extender AKM UK, and Extender AKM MAAP to cover unused spaces.
Extender Series • Installation
2-7
Installation, cont’d
EXTENDER WM AAP
COMPUTER IN
AUDIO IN
#4-40 Nut with Captive Washer
Extender WM AAP
(up to 4 plates)
Adapter Plate
Extron Extender AKM MAAP
Line Driver
EXTENDER AKM
MAAP
COMPUTER IN
AUDIO IN
#4 - 40 Screws
Other adapter plates must be ordered separately. They also must be attached to the faceplate and cabled before the line driver is installed in the wall or furniture. The screws needed for installing the adapter plates are built into the plates, so no additional screws are needed.
1. Remove the blank plates from the Extender by unscrewing
the nuts that fasten the plates to the faceplate.
PRELIMINARY
2. Insert the adapter
plate screws through the holes in the faceplate. Attach the adapter plates to the faceplate with the provided captive washers and #4-40 nuts.
3. Attach the output
cables to the rear connectors of the adapter plates. Soldering is required for some connectors. Attach foil and braided shields to ground connections.
Opening for Mini Architectural Adapter Plates (MAAPs)
f
The Extender AKM MAAP can have up to three optional MAAP adapter plates attached here at one time to allow for a variety of types of audio/video connectors or another device to be added to the faceplate.
2-8
Extender Series • Installation
One double-size and one single-size blank plate are included with the Extender AKM MAAP to cover unused spaces. Other adapter plates must be ordered separately. They also must be attached to the faceplate and cabled before the line driver is installed in the wall, oor box, or furniture. The screws needed for installing the adapter plates are included with the MAAPs, so no additional screws are needed.
Refer to the picture at right and the following steps.
1. Insert the MAAP into the
Extender AKM MAAP’s faceplate opening.
2. Using an Allen wrench,
secure the MAAP to the faceplate with the provided machine screws.
3
1
1
3 4
3
4
1
2
2
Extender MK, Extender AAP, Extender AAP EX, Extender WM AUS,
Extender AKM UK AAP, and Extender AKM MAAP
top view
Extender WM, Extender WM AAP, and Extender D rear view
Extender MK/AAP/AAP EX,
Extender AKM UK AAP,
Extender AKM MAAP,
Extender WM AUS
rear view
Extender MK, Extender AAP, Extender AAP EX, Extender WM AUS,
Extender AKM UK AAP, and Extender AKM MAAP
bottom view
(Side)
a
Audio output connector — page
2-10
b
RGB video output connectors
page 2-11
c
Power connector — page 2-11
d
Gain switch — page 2-11

Top/Rear/Bottom panel Features and Cabling

PRELIMINARY
Extender Series • Installation
2-9
Installation, cont’d
Extender Ser
ies
9-18 VDC
Power
Gain
(Switch is on t
he lower circuit
board.)
Maxim
um
Max. peakin
g
& gain
Medium
– Mid-le
vel
peaking &
gain
Normal
Unity
gain
w
w
w
.extron.com
33-612-02
R
ev
. C
02 05
L
Audio
R
Audio
Unbalanced Output
Left Tip
NO Ground Here
Sleeve (s)
Right Tip
NO Ground Here
Balanced Output
Sleeve (s)
Left Tip
Right Tip
Left Ring
Right Ring
Sleeve (s)
Left Tip
Right Tip
Left Ring
Right Ring
L
Audio
R
L
Audio
R
9-18 VDC
Power
CAUTION
For unbalanced audio, connect the sleeve(s) to the ground contact.
DO NOT connect the sleeve(s)
to the negative (-) contacts.
Do not tin the wires!
Audio output connector — Insert wires into and tighten the
a
screws on this 3.5 mm, 5-pole direct insertion captive screw connector for unbalanced or balanced audio output. Wire the connector as shown in the following illustrations.
C
PRELIMINARY
Connect the sleeve to ground (Gnd). Connecting the
sleeve to a negative (-) terminal will damage the audio output circuits.
Extender WM AUS is shown here wired for balanced audio output; the circuit board configuration is the same
for the Extender MK, Extender AAP, Extender AAP EX, Extender AKM UK AAP, and Extender AKM MAAP
2-10
Extender Series • Installation
Sleeve (s)
Left Tip
Right Tip
Left Ring
Right Ring
9-18 VDC
Power
Audio
Unbalanced Output
Left Tip
NO Ground Here
Sleeve(s)
Right Tip
NO Ground Here
Balanced Output
Sleeve(s)
Left Tip
Right Tip
Left Ring
Right Ring
L
Audio
R
L
Audio
R
Do not tin the wires!
CAUTION
For unbalanced audio, connect the sleeve(s) to the ground contact.
DO NOT connect the sleeve(s) to the
negative (-) contacts.
+ or – – or +
9-18 VDC
Power
Do not tin the wires!
PRELIMINARY
Extender WM is shown here wired for balanced audio output; the circuit board configuration is the same
for the Extender WM AAP and the Extender D
RGB video output connectors — Attach coaxial cables from the
b
Extender to the display device via these female BNC connectors. These BNCs are on pigtail wires secured to the Extender by tie wrap.
Power connector — Connect a 9 VDC to 18 VDC power supply
c
to this 3.5 mm, 2-pole direct insertion captive screw connector. Wire the connector as shown here. Polarity is not important.
C
For best results and to reduce the risk of short circuits,
trim just 3/16” (5 mm) of the jacket from the wires. Do not tin the wires.
Extender Series • Installation
2-11
Installation, cont’d
4
Maximum
Max. peaking
and gain
Medium – Mid-level
peaking and gain
Normal
Unity
gain
4
Maximum
Max. peaking
& gain
Medium – Mid-level
peaking & gain
Normal
Unity
gain
Circuit
board
Faceplate
COMPUTER IN
AUDIO IN
SW1
Maximum
Max. peaking
and gain
Medium
Mid-level
peaking
and gain
Normal – Unity gain
Circuit
board
4
Gain switch
d
PRELIMINARY
Extender MK, Extender AAP, Extender AAP EX, Extender WM AUS, Extender AKM UK AAP, and Extender AKM MAAP gain switch location (access from the rear)
2-12
Extender WM and Extender WM AAP gain switch location
(access from the side)
Extender D gain switch location
(like the Extender WM switch, but accessible from the front)
Extender Series • Installation
PRELIMINARY
To compensate for cable resistance and capacitance, use a small screwdriver to slide this switch to select the level of video gain that yields the sharpest, smear-free picture.
Normal — unity gain (no signal boost)
Medium — mid-level peaking and gain
Maximum — maximum amount of peaking and gain. Select
this for use with longer cables.
N
Adjust the gain before installing the Extender into a
wall, furniture, or equipment, as the gain switch will be inaccessible after installation.
Extender Series • Installation
2-13
Installation, cont’d
Installation Cable
Cable Clamp
Screws or Nails
Wall Stud
#4-40 Nut w/ Captive Washer
Extron
Extender AAP
AAP 102
AAP 102
EXTENDER
COMPUTER IN
AUDIO IN

Mounting the Extenders

Mounting the Extender AAP or Extender AAP EX into an AAP wall plate or device faceplate

The Extender AAP or Extender AAP EX and any other adapter plates must be attached to a device faceplate or AAP wall
PRELIMINARY
plate and cabled before the device or wall plate is pretested or installed in a wall or furniture.
1. Before any user-supplied cables are attached, insert
the Extender AAP or Extender AAP EX’s output BNC connectors and wires through the opening in the front of the wall plate or device faceplate.
2. Insert the AAP’s threaded standoffs through the holes in
the device’s faceplate or AAP wall plate.
3. Using the provided #4-40 nuts and captive washers, secure
the Extender to the faceplate/wall plate.
2-14
Mounting the Extender AAP or Extender AAP EX to a device or wall plate
Extender Series • Installation
RGB - 20”
HV - 18”
Connects to AAP Cable
Front Panel
Extron HSA 822
Tw o Screws Each Side
#4-40 Nut w/ Captive Washer
HSA 822
Cable
Extron Extender AAP EX
COM
PUTER IN
AUD
IO IN
PRELIMINARY
Mounting the Extender AAP EX to an HSA faceplate
4. Repeat steps 1, 2, and 3 to mount other AAPs. Cover any
openings in the faceplate with blank plates (provided).
5. Be sure to include the AAP connectors as part of the
installation pretest before nal installation of the faceplate.
For more detailed installation information, refer to the
installation guide shipped with the faceplate or the HSA.
Extender Series • Installation
2-15
Installation, cont’d

Pre-installation testing/troubleshooting

Before mounting the line driver, test the system to make sure that the connections and settings are correct.
1. Apply power to the line driver. The power/signal LED on
the line driver lights amber to indicate that it is receiving power.
PRELIMINARY
2. If the LED does not light, check the wiring at both the line
driver and the power supply, and make sure the power supply is connected to a power source.
If the image does not appear or there is no sound
1. Make sure that all the devices are powered on.
2. Ensure that the connectors are wired correctly at both
ends of the cables. Audio cables must be wired for an unbalanced stereo input signal and for the appropriate (unbalanced or balanced) output signal.
3. If the input is from a laptop computer and no picture
appears, use a laptop breakout cable for the input connection. Check the computer’s user ’s guide or contact Extron to determine if special commands are required to output video to the external video port. Also, many laptops’ screens shut off after the external video port is activated.
4. Call the Extron S3 Sales and Technical Support Hotline if
the image still does not appear or there is no sound.
2-16
If the image is not displayed correctly
1. If the picture is too bright or too dark, if the edges of the
image seem to exceed their boundaries, or if thin lines and sharp edges look thick and fuzzy, change the gain setting. See “Gain switch” on page 2-12.
If the picture appears and is stable, but it has ghosting
or blooming, verify that the video input is properly terminated. If the problem is not resolved by changing the termination, try using a different input cable. Poor quality or damaged cable can cause ghosting and blooming.
2. If the picture still is not displayed correctly, call the Extron
S3 Sales and Technical Support Hotline.
Once the system has been cabled and tested, the line driver can be installed in the wall, furniture, or equipment.
Extender Series • Installation
Extender WM AAP Install.eps
Installation Cable
Cable Clamp
Wall Stud
Screws or Nails
Extender WM AAP
EXTENDER WM
AAP
C
O
M
PU
TER
IN
AUD
IO IN

Mounting the Extender WM, Extender WM AAP, or Extender WM AUS to the wall box

1. Remove power from the line driver by disconnecting the
power supply.
2. Place the line driver through the opening in the wall or
furniture and into the wall box. Take care not to damage the output cables, which t behind the line driver at the back of the wall box.
3. Mount the line driver’s faceplate to the wall box with
machine screws as shown in the following illustration.
PRELIMINARY
Mounting the line driver to the wall box
4. Reconnect the power supply and restore power to the
equipment.
Extender Series • Installation
2-17
Installation, cont’d
COM
PUTE
R I
N
AUD
IO IN
Wall opening
is flush with
edge of box.
Wall Box
Decora
Faceplate
Extron Extender D
VGA-QXGA Line Driver with Audio

Mounting the Extender D

1. Remove power from the line driver by disconnecting the
power supply.
2. Place the Extender D through the opening in the wall or
furniture and into the wall box. Take care not to damage the output cables, which t behind the line driver at the
PRELIMINARY
back of the wall box.
3. Mount the Extender D to the wall box with machine screws
as shown in the following illustration.
2-18
Mounting the Extender D to the wall box
4. Attach the Decora wall plate to the Extender D as shown in
the illustration above.
5. Reconnect the power supply and restore power to the
equipment.
Extender Series • Installation
M59 Cable
Extender MK
COMPUTER IN
AUDIO IN
EXTENDER MK
3.5 x 30 mm Screw
Double Wide Dry Lining Box

Mounting the Extender MK to the knockout box

1. Remove power from the line driver by disconnecting the
power supply.
2. Place the line driver through the opening in the wall or
furniture and into the knockout box. Take care not to damage the cables, which lie next to the line driver at the side of the box.
3. Mount the line driver’s faceplate to the knockout box with
machine screws as shown in the following illustration.
Mounting the Extender MK to the knockout box
PRELIMINARY
4. Reconnect the power supply and restore power to the
equipment.
Extender Series • Installation
2-19
Installation, cont’d
Exterder WM.eps
Mini HR Cable
Wall Stud
EXTENDER W
M
COMPUTER IN
AUDIO IN
Projector
Laptop w/ Audio
Extender WM
Audio
INPUT
MON
ITOR
H. SHIFT
AUD
IO
MIN/MAX
R
G
B
46
8
WITH
ADSP
T
M
MON
ITOR
NO MONITO
R
E
XT
E
N
D
E
R
COMPUTER IN
A
U
D
IO
IN
Mini HR
Cable
Laptop w/ Audio
Extender AAP
RGB 468xi
Projector
SVGA Compatible
Computer w/ Audio
Extron Extender AKM MAAP
Line Driver
Laptop
Projector
EXTENDER AKM
MAAP
COMPUTER IN
AUDIO IN

Application Diagrams

PRELIMINARY
2-20
Extender Series • Installation
Extender Series
Appendix A
A
Reference
Specifications
Ordering Information
Accessories
Dimensions
Templates
Reference
Specifications
Video
Gain ................................................. 0 dB, 0.6 dB, 1.2 dB, selectable (when
input is 0.7 Vp-p, output is 0.7 V, 0.75 V,
0.8 Vp-p)
Bandwidth ...................................... 300 MHz (-3 dB)
PRELIMINARY
N
Video input
Number/signal type ..................... 1 VGA–QXGA RGBHV, RGBS, RGsB,
Connectors ..................................... (1) 15-pin HD female
Nominal level ................................ 1.0 Vp-p for Y of component video
Minimum/maximum levels ........ Analog: 0.3 V to 1.5 Vp-p with no offset at
Impedance ...................................... 75 ohms
Horizontal frequency .................... 15 kHz to 135 kHz
Vertical frequency .......................... 30 Hz to 170 Hz
Input coupling ............................... DC
Video output
Number/signal type ..................... 1 VGA–QXGA RGBHV, RGBS, RGsB,
Connectors
Nominal level ................................ 1.0 Vp-p for Y of component video
Minimum/maximum levels ........ Analog: 0.3 V to 1.5 Vp-p with no offset at
Impedance ...................................... 75 ohms
DC offset ......................................... ±5 mV with input at 0 offset
Return loss ...................................... <-35 dB @ 5 MHz
ID bits are terminated (pins 4 and 11).
RsGsBs, HDTV component video
0.7 Vp-p for RGB and for R-Y and B-Y of component video
unity gain
RsGsBs, HDTV component video
Extender AAP EX .............. 5 BNC female on 18" (HV) and 20" (RGB)
pigtails
All other models ................ 5 BNC female on 3" pigtails
0.7 Vp-p for RGB and for R-Y and B-Y of component video
unity gain
A-2
Extender Series • Reference
Sync
Input type ....................................... RGBHV, RGBS, RGsB, RsGsBs, bi-level
and tri-level component video sync
Output type .................................... RGBHV, RGBS, RGsB, RsGsBs, bi-level
and tri-level component video sync
Input level ...................................... 2.0 V to 5.0 Vp-p
Output level ................................... TTL: 5 Vp-p, unterminated
Input impedance ........................... 510 ohms
Output impedance ........................ 75 ohms
Max. propagation delay ............... 18.8 ns
Max. rise/fall time ........................ 4 ns
Polarity............................................ Positive or negative (follows input)
Audio
Gain ................................................. Unbalanced output: 0 dB;
balanced output: +6 dB
Frequency response ...................... 20 Hz to 20 kHz, ±0.5 dB
THD + Noise .................................. 0.025% @ 1 kHz, 0.020% @ 20 kHz at
nominal level
S/N .................................................. >90 dB at rated maximum output
Stereo channel separation ............ >75 dB @ 20 Hz to 20 kHz
Audio input
Number/signal type ..................... 1 stereo, unbalanced
Connectors ..................................... (1) 3.5 mm mini stereo jack
Impedance ...................................... >10k ohms unbalanced, DC coupled
Nominal level ................................ -10 dBV (316 mVrms)
Maximum level .............................. +6 dBV, (unbalanced) at 1% THD+N
Audio output
Number/signal type ..................... 1 stereo, balanced/unbalanced
Connectors
Extender WM, Extender WM AUS, Extender WM AAP, Extender D
(1) 3.5 mm direct insertion captive screw
connector, 5 pole
Extender AAP, Extender AAP EX, Extender MK, Extender AKM UK AAP, Extender WM AUS, Extender AKM MAAP
(1) 3.5 mm captive screw connector, 5 pole
Impedance ...................................... 50 ohms unbalanced, 100 ohms balanced
PRELIMINARY
Extender Series • Reference
A-3
Reference, cont’d
Nominal level ................................ -2 dBu, balanced; -10 dBV unbalanced
Maximum level (Hi-Z) ................. +14 dBu, balanced, at 1% THD+N
Maximum level (600 ohm) ........... +6 dBm, balanced, at 1% THD+N
N
0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV 2 dBu
General
PRELIMINARY
External power supply ................. 100 VAC to 240 VAC, 50-60 Hz, external; to
12 VDC, 1 A (max.), regulated
Power input requirements ........... 12 VDC, 0.2 A
Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) /
10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) /
10% to 90%, noncondensing
Cooling ........................................... Convection, no vents
Mounting
Floor box mount
Extender AKM UK AAP Ackerman UK oor box mountable Extender AKM MAAP Ackerman oor box mountable in either a
GB2 or a GB3 mounting space
Furniture mount
Extender AAP EX ...... Mountable in an optional HSA 800 Series
or HSA 400 Series Hideaway Surface
Access Enclosure, which can be mounted
in furniture
Extender WM AUS .... Wall or furniture mountable in a standard
Australian electrical wall box
Extender AAP ............ Wall or furniture mountable with optional
AAP mounting faceplates
All other models ........ Wall or furniture mountable in a standard
US electrical wall box
Enclosure type ............................... Metal (Extender D has a metal faceplate
and a plastic Decora wall plate.) Enclosure dimensions
Extender AAP, Extender AAP EX
Faceplate ..................... 1.4" H x 3.5" W x 0.1" D
(3.6 cm H x 8.9 cm W x 0.3 cm D)
(double space high AAP plate)
Buffer ........................... 1.1" H* x 2.75" W x 1.2" D
(2.8 cm H* x 7.0 cm W x 3.0 cm D)
(*Height excludes BNC connectors and
cables.)
A-4
Extender Series • Reference
Extender WM
Faceplate ..................... 4.5" H x 2.8" W x 0.1" D
(11.4 cm H x 7.1 cm W x 0.3 cm D) (1 gang)
Buffer ........................... 2.7" H x 1.8" W x 0.75" D*
(6.9 cm H x 4.6 cm W x 1.9 cm D*) (*Depth excludes BNC connectors and cables.)
Extender WM AUS
Faceplate ..................... 3.0" H x 4.7" W x 0.1" D
(7.6 cm H x 11.8 cm W x 0.3 cm D)
Buffer ........................... 2.75" H* x 1.1" W x 1.2" D
(7.0 cm H* x 2.8 cm W x 3.0 cm D) (*Height excludes BNC connectors and cables.)
Extender WM AAP
Faceplate ..................... 4.5" H x 6.4" W x 0.1" D
(11.4 cm H x 16.3 cm W x 0.3 cm D) (3 gang)
Buffer ........................... 2.7" H x 1.8" W x 0.75" D*
(6.9 cm H x 4.6 cm W x 1.9 cm D*) (*Depth excludes BNC connectors and cables.)
Extender MK
Faceplate ..................... 3.4" H x 5.7" W
(8.6 cm H x 14.4 cm W) (UK knockout box size)
Buffer ........................... 1.1" H* x 2.75" W x 1.2" D
(2.8 cm H* x 7.0 cm W x 3.0 cm D) (*Height excludes BNC connectors and cables.)
Extender AKM UK AAP
Faceplate ..................... 3.0" H x 8.1" W x 0.6" D
(7.6 cm H x 20.6 cm W x 1.5 cm D)
Buffer ........................... 1.1" H* x 2.75" W x 1.2" D
(2.8 cm H* x 7.0 cm W x 3.0 cm D) (*Height excludes BNC connectors and cables.)
Extender AKM MAAP
Faceplate ..................... 1.67" H x 6.12" to 7.85" W* x 3.0" D
(4.1 cm H x 15.5 cm to 19.9 cm W* x
7.6 cm D) *Width is adjustable.
Buffer ........................... 1.8" H x 4.4" W x 3.0" D
(4.6 cm H x 11.2 cm W x 7.6 cm D)
PRELIMINARY
Extender Series • Reference
A-5
Reference, cont’d
Extender D
Faceplate ..................... 2.6" H* x 1.3" W x 0.1" D
(6.6 cm H* x 3.3 cm W x 0.3 cm D) (Fits the opening in a 1 gang Decora faceplate. *Height is 3.8" [9.7 cm] including mounting tabs.)
PRELIMINARY
Product weight
Shipping weight
Vibration ......................................... ISTA 1A in carton (International Safe
Regulatory compliance
MTBF ............................................... 30,000 hours
Warranty ......................................... 3 years parts and labor
Buffer ........................... 2.7" H x 1.8" W x 0.75" D*
(6.9 cm H x 4.6 cm W x 1.9 cm D*) (*Depth excludes BNC connectors and cables.)
Extender AAP, Extender AAP EX, Extender WM
0.2 lbs (0.1 kg)
Extender WM AUS ............ 0.3 lbs (0.1 kg)
Extender WM AAP ........... 0.4 lbs (0.2 kg)
Extender MK ...................... 0.5 lbs (0.3 kg)
Extender AKM UK AAP .. 0.6 lbs (0.3 kg)
Extender AKM MAAP ...... 1.2 lbs (0.5 kg)
Extender D ......................... 0.2 lbs (0.1 kg)
Extender AAP, Extender AAP EX
2 lb (1 kg)
All other models ................ 3 lbs (2 kg)
Transit Association)
Safety ................................... CE, CUL, UL
EMI/EMC .......................... CE, C-tick, FCC Class A, ICES, VCCI
N
N
A-6
All nominal levels are at ±10%.
Specifications are subject to change without notice.
Extender Series • Reference

Ordering Information

This section lists part numbers for each Extender and Extender kit.
Model Part numbers
Extender AAP1 (black, white, RAL9010 white)
Extender AAP EX1 (black) Extender WM1 (black, white) 60-398-12, -22 Extender WM AAP1
(gray, black, white, RAL9010 white) Extender WM AUS1 (white) 60-398-32 Extender D1 (black, white) 60-759-12, -22 Extender MK1
(black & white, RAL9010 white) Extender AKM UK AAP Extender AKM MAAP
1
An international, 12 VDC, 2 A, external power supply (#70-055-01) and this user’s manual (#68-552-01) ship with all Extender products.
2
In addition, a double-size, blank AAP (#70-090-02); a single-size, blank AAP (#70-090-01); and the Extender AKM UK AAP Installation Guide ship with the Extender AKM UK AAP.
3
In addition, a double-size, blank MAAP (#991994-2); a single-size, blank MAAP (#991993-2); and the Extender AKM MAAP Installation Guide ship with the Extender AKM MAAP.
70-147-12, -22, -52
70-147-72
60-405-02, -12, -22, -52
60-406-12, -52
1, 2
(gray) 60-627-01
1, 2
(black) 60-727-02
PRELIMINARY

Accessories

Mounting accessories

AAP mounting accessories Part numbers
AAP 102 – 2 gang wall plate (gray, black, white, RAL9010 white)
AAP 104 – 4 gang wall plate (black, white, RAL9010 white)
AAP 201 – half rack wide, 1U high AAP mounting frame (gray, black, white)
AAP 201 – half rack wide, 1U high AAP mounting frame (black, white)
60-300-01, -02, -03,
-05
60-301-02, -03, -05
60-302-01, -02, -03
60-303 -02, -03
Extender Series • Reference
A-7
Reference, cont’d
Mud rings/mounting brackets Part numbers
MR 100 – 1-gang modular plastic mud ring (black, white)
MR 100D – 1-gang Decora®-style modular plastic mud ring (black)
PRELIMINARY

Cables

MR 300 – 3-gang modular plastic mud ring (black, white)
MR 300D – 3-gang Decora®-style modular plastic mud ring (black)
MK 2-gang metal mounting bracket/ mud ring (black, white, RAL9010 white
Miscellaneous cables Part numbers
SY VGAM-RGBHVM cable – 15-pin VGA male to 5 BNC male, 6'
SY VGAM-RGBHVF cable – 15-pin VGA male to 5 BNC female, 3'
70-519-12, -13
70-581-12
70-519-32, -33
70-581-32
70-086-16, -26, -56
26-533-02
26-548-12
A-8
Male-to-female VGA with audio cables
VGA-A M-F MD/3 /6 /12 /25 /35 /50 – with molded connectors – 3' (90 cm), 6' (1.8 m), 12' (3.6 m), 25' (7.6 m), 35' (10.6 m), 50' (15.2 m)
VGA-A M-F BK/3 /6 /12 /25 /35 /50 – with backshell connectors – 3' (90 cm), 6' (1.8 m), 12' (3.6 m), 25' (7.6 m), 35' (10.6 m), 50' (15.2 m)
Extender Series • Reference
Part numbers
26-491-01, -02, -03,
-04, -07, -08
26-491-09, -10, -11,
-12, -06, -05
0.583
0.250
0.860
1.266
2.125
2.917
3.250
3.500
COMPUTER IN
AUDIO IN
ø 0.125 THRU WITH ø 0.220 X 100° C'SINK NEAR SIDE (2 PLACES)
10°
(2 PLCS)
R 0.132“ (TYP)
ø 0.250” THRU
DETAIL A
DETAIL A
ø 0.125” THRU
ø 0.125 THRU
(2 PLCS)
0.984
0.806
0.224
0.449
R 0.040 (TYP)
0.345
(REF)
0.700 (REF)
0.250” (REF)
0.050” (REF)
3.000” (REF)
0.000
0.000
1.400
0.345
1.045
0.650

Dimensions

N
The drawings in this section are not full size.
Do not scale.
N
All dimensions are given in inches.

Extender AAP and Extender AAP EX dimensions

PRELIMINARY
Extender Series • Reference
A-9
Reference, cont’d
EXTENDER WM
4.500
3.890
0.610
1.107
1.550
2.010
2.570
3.392
COMPUTER IN
AUDIO IN
0.000
0.000
2.790
1.395
ø 0.156 THRU WITH ø 0.290 X 82° C'SINK (2 PLACES)
ø 0.330 THRU WITH ø 0.562 C'BORE
0.070 DEEP
ø 0.125 THRU

Extender WM dimensions

PRELIMINARY
A-10
Extender Series • Reference
EXTENDER WM AAP
4.500
3.890
0.610
1.107
1.550
1.930
2.490
2.950
3.393
COMPUTER IN
AUDIO IN
0.000 0.000”
1.200”
0.845”
1.900”
2.600”
3.300”
4.500”
0.000
6.400
1.388
2.780
2.650
2.390
5.013
5.520
5.650
ø 0.156” THRU WITH
ø 0.290” X 82° C'SINK
(4 PLACES MARKED C)
ø 0.330” THRU WITH
ø 0.562” C'BORE
0.070” DEEP
ø 0.170”
(8 PLCS)
ø 0.125” THRU
C C
C C
R 0.070" TOP EDGE
(ALL AROUND)
0.100
THK.
(REF)
2.810
+0.010
-
0.000
3.520
+0.010
-
0.000
0.050
+0.003
-
0.000
ø 0.125” THRU WITH
NEAR SIDE
(2 PLACES)
10° (2 PLCS)
DETAIL B
A
A
DETAIL B
ø 0.125 THRU
C'BORE
ø 0.250 x 0.50
DEEP (2 PLCS)
R 0.132
(TYP)
0.984
0.806
0.224
0.449
SECTION A–A
R 0.240”
(TYP)
R 0.070”
TOP EDGE
(ALL AROUND)
0.060”
0.060”

Extender WM AAP dimensions

PRELIMINARY
Extender Series • Reference
A-11
Reference, cont’d
EXTENDER WM AUS
COMPUTER IN
AUDIO IN
0.000
0.671
1.157
1.434
1.840
2.228
3.493
3.979
4.650
0.000”
3.000”
2X Ø 0.125” THRU
Ø 0.220” X 100°
Ø 0.250” THRU
Ø 0.125” THRU

Extender WM AUS dimensions

PRELIMINARY
A-12
Extender Series • Reference
EXTENDER MK
5.700
5.224
0.474
1.681
1.460
1.958
2.365
3.244
4.017
4.240
COMPUTER IN
0.000
0.000
3.380
1.690
ø 0.156” THRU WITH
ø 0.290” X 100° C'SINK
(2 PLCS)
ø 0.125” THRU WITH
ø 0.220” X 100° C'SINK NEAR SIDE (2 PLCS)
10°
(2 PLCS)
ø 0.250”
THRU
DETAIL A
DETAIL A
ø 0.125” THRU
ø 0.125” THRU
(2 PLCS)
0.984”
0.806
0.224”
0.449”
R 0.040” (TYP)
C'BORE 2.780 x 1.070 x 0.050 DEEP
(C’BORE FAR SIDE)
+0.003
-0.000
0.100”
THICK
R 0.070”
TOP EDGE
(ALL AROUND)
0.060”
AUDIO IN

Extender MK dimensions

PRELIMINARY
Extender Series • Reference
A-13
Reference, cont’d
B
B
7.156”
4X 1.500”
3.000”
Ø 0.174” THRU
2X Ø.125” THRU
w Ø.272” x 100°
MARKED B
0.590”
(7.156)
4X R 0.060”
3X 3.768”
3X 6.768”
6X Ø 0.180”
THRU
0.000”
0.325”
0.000”
0.272”
0.457”
R 0.030”
(TYP)
0.445”
7.428”
7.613”
3.898”
6.638”
5X 1.643”
1.895”
2.667”
1.016”
0.610”
Ø 0.125”
THRU
Ø 0.250”
THRU
DETAIL A
2X 2.200”
2X 0.800”
10°
(2 PLCS)
DETAIL A
ø 0.125 THRU
(2 PLCS)
ROTATED 90° C.W.
0.984
0.806
0.224”
0.449”
+0.020”
-0.000”
2.110

Extender AKM UK dimensions

PRELIMINARY
A-14
Extender Series • Reference
A
A
4X R 0.125”
2X R
2X R 0.062 2X 2.350
2X 0.650
1.975
1.750
1.250
1.025
2X 0.06” X 45°
2X 2.250”
3.000
+0.000
-0.015
2X Ø 0.150” THRU
2X 0.750”
0.000”
0.000
2X 2.250
2X 1.050
3.100
5.375
5.750 3X 5.000
2X 5.249
2X 5.713
6.020±020
1.675
0.275
0.000
(0.075”)

Extender AKM MAAP dimensions

PRELIMINARY
Extender Series • Reference
A-15
Reference, cont’d
2.610”
2.005”
1.545”
0.984”
0.000”
Ø 0.132” THRU
Ø 0.258” THRU
2X EXTRUSION FOR
#6-32 SCREW
TAPPING
0.111”
0.359
0.905”
(0.223”)
2X 0.125”
0.330”
0.399”
0.625”
2X 0.111”
BOTH SIDES
2X 0.062” X 45°
2X Ø 0.106” THRU
0.223”
0.333”
1.290”
0.000” 7X 0.645”
1.290”

Extender D dimensions

PRELIMINARY
A-16
Extender Series • Reference
4.50"
(11.43 cm)
Cut Out Line for Installing the Electrical Box
Top Panel
2.79"
(7.09 cm)
Extender WM
Cut-Out Template for the Extron
2.24"
(105 cm)
4.13"
(57 cm)
SURFACE
CUT-OUT
AREA FOR
MOUNTING
Location of Extender AAP Circuit Board
TEMPLATE IS FULL SIZE.
Please verify dimensions prior to cutting.

Templates

N

Extender WM template

Always check and use the dimensions given in this
appendix.
PRELIMINARY
Extender Series • Reference
A-17
Reference, cont’d
6.4"
(16.3 cm)
Top Panel
4.5” (11.43 cm)
Location of Extender AAP Circuit Board
Extender WM AAP
Cut-Out Template for the Extron
SURFACE
CUT-OUT AREA
FOR MOUNTING
Cut Out Line for Installing the Electrical Box
TEMPLATE IS FULL SIZE.
5.73”
(14.55 cm)
3.86” (9.80 cm)
Please verify dimensions prior to cutting.

Extender WM AAP template

PRELIMINARY
A-18
Extender Series • Reference
5.70"
(14.48 cm)
To install an Extender MK directly into furniture, cut along this line.
To p Panel
3.38"
(8.56 cm)
Extender MK
Cut-Out Template for the Extron
1.85"
(4.70 cm)
2.91"
(7.40 cm)
TEMPLATE IS FULL SIZE.
Location of Extender Circuit Board
SURFACE
CUT-OUT AREA
FOR MOUNTING
Please verify dimensions prior to cutting.

Extender MK template

PRELIMINARY
Extender Series • Reference
A-19
Reference, cont’d
4.65"
(11.81 cm)
Top Panel
3.00"
(7.62 cm)
Extender WM AUS
Cut-out Template for the Extron
TEMPLATE IS FULL SIZE.
1.85"
(4.70 cm)
2.91"
(7.40 cm)
SURFACE
CUT-OUT AREA
FOR MOUNTING
To install the Extender WM AUS directly into furniture, cut along this line.
Location of Extender Circuit Board
Please verify dimensions prior to cutting.

Extender WM AUS template

PRELIMINARY
A-20
Extender Series • Reference
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, and Central America:
Extron USA 1001 East Ball Road
Anaheim, CA 92805
U.S.A.
Europe, Africa, and the Middle East: Extron Europe
Hanzeboulevard 10 3825 PH Amersfoort
The Netherlands
Asia: Extron Asia 135 Joo Seng Road #04-01 PM Industrial Bldg. Singapore 368363 Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper
handling care, electrical or mechanical abuse, abnormal operating conditions or non­Extron authorized modification to the product.
If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), 65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you
assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
Japan: Extron Japan Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan
China: Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China
Middle East: Extron Middle East
Dubai Airport Free Zone F12, PO Box 293666 United Arab Emirates, Dubai
Extron USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
Extron USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794 +1.919.863.1797 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040 +31.33.453.4050 FA X
Extron Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400 +65.6383.4664 FAX
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China
+400.883.1568
Inside China Only
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800 +971.4.2991880 FAX
© 2009 Extron Electronics. All rights reserved.
www.extron.com
Loading...