Extron electronic P-N 68-412-02 User Manual

Page 1
Configuration and ConnectionsHughes Installation
SYSTEM 4xi
PROJECTOR COMMUNICATIONS KIT
ATTENTION!
PLEASE READ THIS DOCUMENT FOR IMPORTANT
THIS KIT HAS BEEN SHIPPED WITH THE FOLLOWING COMPONENTS:
Kit Type: HUGHES
Included Communications Adapter(s):
Quantity Part Number Description
1 26-467-01 ADP, UNV, “A”
THE TABLE BELOW LISTS THE POSSIBLE CONFIGURATION(S) AND CORRESPONDING COMMUNICATIONS ADAPTER(S) FOR YOUR PROJECTOR MANUFACTURER’S VARIOUS MODELS. PLEASE NOTE THAT YOUR SWITCHER HAS BEEN CONFIGURED AS
INDICATED BY THE IN THE CONFIG AS COLUMN. IF YOUR PROJECTOR MODEL DIFFERS FROM THIS CONFIGURATION, YOU MUST RECONFIGURE YOUR SWITCHER
WITH THE CORRECT SETTINGS. PLEASE REFER TO THE FOLLOWING PAGES FOR COMPLETE CONFIGURATION AND
SIGNAL CONNECTION INSTRUCTIONS.
THIS SWITCHER HAS BEEN CONFIGURED FOR: HUGHES
CONFIG MODEL SW1 SW2 SW3 SW4 SW5 SW6 PROJ COMM
AS 1 2 3 4 CABLE ADAPTER
Hughes-JVC off on off on 0 0 5 6 0 J15 26-467-01
Hughes DILA off on off on 0 0 8 F 0 J15 26-467-01
Extron • System 4xi Switcher Series • User’s Manual • P/N 68-412-02 Rev. A
Page 2
Hughes Installation Configuration and Connections
y
)
Connecting System 4xi to Hughes/JVC Projectors
If the System 4xi is already configured for a Hughes/JVC projector, go to step 4. If it is not set up correctly, it will be necessary to change switch settings on the System 4xi s Main Controller Board. Begin at Step 1 to verify the correct configuration.
1. Use the Front Panel to display the Information Menu to verify that the System 4xi is already set up for the Hughes/JVC projector. Apply power to the System 4xi and do the following:
[System 4 model and software
version displayed here]
(See note.)
(See note.)
(See note.)
(Note: Information depends on
stem 4 setup.
S
(See note.)
a. Press b. Press c. Press d. Press
}
yours will show the System 4xi model name, the software version and the following information: PRJ = HUGHES PRJ BAUD = 19200 UNIT No.= 000 HST BAUD = 9600 (value depends upon setup Menu 3)
to display the MENU SELECT on the LCD screen.
or to step to Menu 8.
to select this menu.
or to display the configuration. The example to the left is general,
2. Go to the procedure on page 2-3 to remove the System 4xi cover and then go to page 2-4 to set up the Main Controller board. Return to Step 3 (below) when the configuration is correct.
Config Projector SW1: 1-2-3-4 SW2 SW3 SW4 SW5 SW6 Prj Cable Comm
as Adapter
Hughes-JVC off-on-off-on 0 0 5 6 0 J15 26-467-01
SW3
SW5
SW2
SW4
3. Double-check your work and be sure the System 4xi cover is on securely.
4. Install the System 4xi in its place of operation (i.e. rack), but do not connect the power cable.
__________ Changes in some switch configurations are not detected until the power is
removed at the AC cord, and then restored.
Follow the correct cable connection diagram for your Hughes projector and continue the installation.
5. The UNV ADP, “A” (26-467-01) has two 9-pin connectors, one male and one female. Plug the 9-pin female connector onto the 9-pin male marked Control Out (Port B) on the Hughes projector back panel.
Extron System 4xi Switcher Series Users Manual P/N 68-412-02 Rev. A
J15
SW1
4
3
2
1
ON
Page 1
Page 3
6. Plug the 15-pin HD connector of the Projector Communications Extension cable (CC 50' or CC 100') into the PJ Comm port on the System 4. The other end has a 9-pin female connector. Plug this end into the other 9-pin male D connector on the HU COM adapter.
______ Secure all of the connector screws.
7. Plug the (4 or 5) BNC connectors from one end of the (user-supplied) RGBS/HV cable onto the System 4 output and those on the other end onto the matching BNCs on the Hughes panel. See cable diagram in Figure 2-18a or 2-18b.
____________ If installing the Hughes HJT 100/200, you must also follow the special setup
instructions on page 4.
System 4xi - Hughes/JVC Model 300/400 Series Connections
Use illustration below as a guide when connecting the System 4xi to a Hughes/ JVC model 400 projector. Refer to Hughes/JVC documentation to continue the installation.
Configuration and ConnectionsHughes Installation
ADP UNV "A" 26-467-01
"A"
Connecting the System 4xi to a Hughes/JVC Model 400 Projector
____________ In a rack mount, do NOT allow the weight of the cables to be supported by the
xi
System 4
. See page 2-5 for cabling guidelines.
Extron System 4xi Switcher Series Users Manual P/N 68-412-02 Rev. A
Page 2
Page 4
Hughes Installation Configuration and Connections
System 4xi - Hughes/JVC Model HJT 100/200 Series Connections
Use the illustration below as a guide when connecting the System 4xi to a Hughes/JVC HJT 100/200 projector. Refer to Hughes documentation to continue the installation.
Hughes HJT 200 Projector
Terminal In
Port A
UNV ADP "A" 26-467-01
Control Out
(Port B)
"A"
CC 50'
3, 4, or 5 BNC Cable
Connecting the System 4xi to a Hughes/JVC HJT 200 Projector
____________ In a rack mount, do NOT allow the weight of the cables to be supported by the
xi
System 4
. See page 2-5 for cabling guidelines.
Extron System 4xi Switcher Series Users Manual P/N 68-412-02 Rev. A
Page 3
Page 5
Special Instructions for the HJT Model 100/200 Series
The projector documentation provides instructions on how to set up and configure the Model 100/200 Series Projector for proper operation with the System 4xi.
The baud rate for the Extron switchers is 19200. Since Port A is locked to a baud rate of 9600, Port B should be used for Extron Switchers. The projector port assignment must be selected and the VIC channel assignment must be edited for a switcher. Following is a description of the HJT 100/200 Series Menu.
To select the Baud Rate from the Projector:
1. Go to Main Menu, select #7,
2. From the Comm. Setup menu, select Port B Speed.
3. From the Speed selection list, select 19200.
4. Press Escape to go back to the Comm. Setup level.
To set the projector port assignment from the Projector:
1. From the Comm. Setup menu, select Port B Device.
System
, then #4,
Configuration and ConnectionsHughes Installation
Comm. Setup
.
2. From the Device type list, select #3,
3. Turn power off at the remote control.
4. Wait until the Arc Lamp fans have stopped running, and provide a system cold boot by toggling the circuit breaker on the projector rear panel to Off, then back to On.
To edit the VIC channel assignment from the Projector:
(see the Model 200 Users Guide, Section 5.3.1 for more information on editing):
1. From the Channels list, select the channel that the switcher will be assigned to.
2. Press Mode. This is a toggle key that brings up a submenu for editing. (Press Mode again to remove the submenu.)
3. Select Edit from the submenu and press Enter.
4. Use the right arrow key to toggle over to the third VIC column.
5. Press Enter and use the up/down arrow keys to select the current switcher channel number. Press Enter when the current switcher channel number is shown.
6. Press Escape to exit the Edit mode.
Video Switcher
.
Extron System 4xi Switcher Series Users Manual P/N 68-412-02 Rev. A
Page 4
Page 6
Hughes Installation Configuration and Connections
y
)
Connecting System 4xi to Hughes-JVC DILA G1000/G10 Projectors
If the System 4xi is already configured for a Hughes-JVC DILA projector, go to step 4. If it is not set up correctly, it will be necessary to change switch settings
on the System 4xi s Main Controller Board. Begin at Step 1 to verify the correct configuration.
1. Use the Front Panel to display the Information Menu to verify that the System 4xi is already set up for the Hughes-JVC DILA projector. Apply power to the System 4xi and do the following:
to display the MENU SELECT on the LCD screen.
or to step to Menu 8.
to select this menu.
or to display the configuration. The example to the left is general,
[System 4 model and software
version displayed here]
(See note.)
(See note.)
(See note.)
(Note: Information depends on
stem 4 setup.
S
(See note.)
a. Press b. Press c. Press d. Press
}
your display will show the System 4xi model name, the software version and the following information: PRJ = HUGHES PRJ BAUD = 19200 UNIT No.= 000 HST BAUD = 9600 (value depends upon setup Menu 3)
2. Go to the procedure on page 2-3 of the
System 4xi Users Manual
to remove the System 4xi cover. Then go to page 2-4 and refer to the configuration below to set up the Main Controller board. Continue with Step 3 (below) when the configuration is correct.
Config Projector SW1: 1-2-3-4 SW2 SW3 SW4 SW5 SW6 Prj Cable Comm
as Adapter
Hughes/JVC DILA off-on-off-on 0 0 8 F 0 J15 26-467-01
SW3
SW5
SW2
SW4
3. Double-check your work and be sure the System 4xi cover is on securely.
4. Install the System 4xi in its place of operation (i.e. rack), but do not connect the power cable.
__________ Changes in some switch configurations are not detected until the power is
removed at the AC cord, and then restored.
Refer to the following connection diagrams for your Hughes projector and continue the installation. Use the UNV ADP “A” (26-467-01) provided by Extron.
Extron System 4xi Switcher Series Users Manual P/N 68-412-02 Rev. A
J15
SW1
4
3
2
1
ON
Page 5
Page 7
5. The Hughes Adapter has two 9-pin connectors, one male and one female. Plug the 9-pin female connector onto the 9-pin male marked Control Out (Port B) on the Hughes projector back panel.
6. Plug the 15-pin HD connector of the Projector Communications Extension cable (CC 50' or CC 100') into the PJ Comm port on the System 4xi. The other end has a 9-pin female connector. Plug this end into the other 9-pin male D connector on the HU COM Adapter.
______ Secure all of the connector screws.
7. Plug the (4 or 5) BNC connectors from one end of the (user-supplied) RGBS/HV cable onto the System 4xi output and those on the other end onto the matching BNCs on the Hughes panel.
System 4xi Series – Hughes-JVC DILA Projector Connections
Use the illustration below as a guide when connecting the System 4xi to a Hughes-JVC DILA projector. Refer to Hughes documentation to continue the installation.
Configuration and ConnectionsHughes Installation
ADP UNV "A" 26-467-01
"A"
____________ In a rack mount, do NOT allow the weight of the cables to be supported by the
System 4
xi
. See page 2-5 for cabling guidelines.
Extron System 4xi Switcher Series Users Manual P/N 68-412-02 Rev. A
Page 6
Loading...