Extron electronic MLC 52 RS VC MK, MLC 52 RS MK User Manual

Page 1
MediaLink
MediaLink®
Controllers for
MK Junction Boxes
MLC 52 RS MK
MLC 52 RS VC MK
Simply take control of
your A/V system
Universal display control
Discrete ON and OFF display power
controls
Volume control using buttons or
integrated volume control knob
buttons
Three easy ways to configure:
IR learning, preconfigured display drivers, and IR beaming
Inactivity timer for display shutoff
Front panel security lockout
Designed to mount in a 47 mm deep
MK junction box for UK, Singapore, Hong Kong and other markets that use MK-type junction boxes
Available with white or brushed
aluminum faceplate
www.extron.com
Page 2
Introduction
MLC 52
Extron MLC 52 RS MK and MLC 52 RS VC MK MediaLink Controllers are economical control panels ideally suited for conference room or classroom A/V systems. Each model fits in a standard MK wall or junction box and offers IR control and unidirectional RS-232 control. The MLC 52 RS VC MK adds an integrated volume control knob for use with any Extron power amplifier or preamplifier with a remote volume control port. By providing easy input selection, power, and volume control, these controllers make classroom A/V operations simple. Both models are available in a white or brushed aluminum finish to complement a wide range of environments.
Consistent A/V Control in Every Room
Each MLC 52 controller acts as an extended remote control panel, providing user-friendly control for a display’s power, volume, and input selection. Because the MLC 52 offers a central point of control for a display device’s key functions, it eliminates the need for the display’s handheld IR remote control, making operations much more efficient. With the MLC 52, there are no misplaced remotes to search for, no confusing menus to navigate through, and no dead batteries to replace.
No matter what brand of display is installed in each presentation venue, the MLC 52 MediaLink Controllers always provide a consistent control method from room to room. Presenters with little or no training can walk into any MediaLink equipped classroom and operate the A/V system with ease.
Confi gurable Buttons for Flexible Control Options
The MLC 52 MediaLink Controllers are easy to confi gure and no programming is required to make them work. Each MLC 52 has six buttons that can be confi gured to control almost any function of the projector, such as selecting an input, controlling the volume, muting the picture or switching it on and off. Using the intuitive setup software provided, these buttons can be confi gured to send out any IR or RS-232 command supported by the projector, making it easy to customize the controller to meet the needs of single-display A/V systems.
Each button can store up to four separate commands, providing additional fl exibility to meet the specifi c control requirements for most display devices. When a button is confi gured for Macro mode, all of the stored commands associated with that button can be sent with the press of a single button. In Toggle mode, the button steps through a series of two, three, or four commands, issuing a single command with each press of the button.
Free Projector Drivers
Extron creates and administers a wide selection of commonly used projector control drivers. These IR and serial RS-232 drivers allow MediaLink Controllers to communicate with a display device. They enable control of basic projector functions such as power, input selection, and volume adjustment. Go to the Extron Web site at www.extron.com to download drivers for the latest and most popular projectors.
Three Easy Ways to Confi gure
The MLC 52 enables integrators to choose any of three methods when configuring the controllers. When used with the supplied Windows
®
-based configuration software, installation files can be saved and used to duplicate additional MLC 52 models. The files can also be archived for later use.
Simple configuration wizard - Experience
fast and simple setup within minutes using the front panel configuration port, supplied software, and the PC’s RS-232 port. Quickly allocate a function to a button just by dragging the command to the desired button.
IR learning - Set up the MLC 52 directly by
beaming commands from the IR remote to the MLC 52, without the need for software and a PC.
IR beaming - Setting up multiple controllers
with the same configuration is made easy with IR beaming. Simply beam the complete configuration from one MLC 52 controller to another controller, without using any cable or software.
Convenient MK size
The MLC 52 RS MK Series controllers were designed to fit the standard 1-gang (MLC 52 RS MK)
or 2-gang
(MLC 52 RS VC MK) MK Electric size boxes. This gives maximum flexibility to the installer to mount the controller in either MK size junction boxes, surface mount boxes, or cable channels.
MLC 52 RS MK MediaLink Controller
Page 3
Overview
MLC 52
Display ON/OFF
Clearly labeled buttons make it easy and convenient to turn the display on and off, eliminating the need for an external display remote
Volume Control
Provides level control of a display’s speaker or variable line level output. If control is not required or additional source switching is needed, these buttons can be configured for input selection, display mute, auto-image, or other commands
MK Standard Size
MLC 52 RS MK Series controllers fit conveniently in standard MK size junction boxes
MLC 52 RS MK Front Panel
Configuration Port
Allows for configuration of the MLC 52 via the front panel
White or Brushed Aluminum
Available in white or brushed aluminum finish to complement a wide range of environments
Backlit Buttons
Illuminated buttons can be custom-labeled with supplied label insert sheets for easy identification. These buttons are helpful for presenters in low-light environments
Multiple Memories
Each button can store up to four IR or serial RS-232 commands
Volume Control Knob
The MLC 52 RS VC MK features an integrated volume control knob for use with any Extron amplifier or preamplifier with a
remote volume control port
Built-In IR Emitter/Receiver
Enables IR learning of commands from the display’s handheld remote. Also provides IR beaming for controller­to-controller configuration without software
IR Learning Indicators
LEDs that provide visual feedback of memory block status and learning mode
MLC 52 Back Panel
MLC 52 RS VC MK in brushed aluminum finish
Inactivity Timer for Display Shut-off
Adjustable timer controls automatic shutdown to conserve energy, prevent plasma burn-in, or extend projector lamp life
IR Remote Control Input Port
Hardwired IR input for control with optional handheld remote and signal repeater
Display Control Port
Provides serial RS-232 and IR universal display control
MLC 52 RS MK Back Panel
Page 4
POWER
12V 3A MAX.
OUTPUTS
4/8 Ohms SPEAKERS
INPUTS
L
R
L
R
REMOTE
10V VOL/MUTE
L
MPA 122
R
VOLUME
MLC 52
OFF
ON
PC
DVD
VCR
Projector
PC VGA with Audio
DVD/VC R Combo S-vide o and Compos ite Vide o with Audi o
Audio Outp ut
Extron MPA 122
Mini Power A mplie r
Volume Control
Extron MLC 52 RS VC MK
Basic MediaLink® Controller with IR, RS-232, and Volume Control
RS-232 Projector Control
Extron SI 26X
Ceiling Speakers
Extron EMEA
+800.3987.6673
Inside Europe Only
+31.33.453.4040 +31.33.453.4050 FAX
Extron USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714 .491.1 500 +1.714 .491.1 517 FAX
Extron USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794 +1.919.863.1797 FA X
Extron Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400 +65.6383.4664 FAX
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China
+400.883.1568
Inside China Only
+86.21.3760.1568 +86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800 +971.4.2991880 FAX
09-01 68-1672-01 REV. A
specifications
Specifi cations are subject to change without notice.
© 2009 Extron Electronics. All rights reserved. All trademarks mentioned are the property of their respective owners.
MLC 52
Application Diagram and Specifi cations
CONTROL — HOST PORTS
Serial control port ............................................... 1 bidirectional RS-232 front panel 2.5 mm mini stereo jack
Baud rate and protocol ....................................... 9600 baud, 8 data bits, 1 stop bit, no parity
Serial control pin confi gurations ......................... Mini stereo jack: tip = TX, ring = RX, sleeve = GND
Program control ................................................. Extron’s confi guration program for Windows
®
Extron’s Simple Instruction Set (SIS™)
IR learning frequencies ....................................... 30 kHz to 62 kHz
IR learning distance ............................................ 4" (10 cm) to 14" (36 cm) from the front panel
CONTROL — SERIAL PORT
Display control port ............................................ (1) 3.5 mm captive screw connector, 6 pole for unidirectional
RS-232 control (±5 V) (connector is shared with IR control
port and power input)
Baud rate and protocol (RS-232) ......................... 57600 to 1200 (9600 default) baud (confi gurable);
8 (default) or 7 data bits;
1 stop bit; no parity (default), or even or odd parity
CONTROL — PROJECTOR/PLASMA (IR PORT)
IR control port .................................................... (1) 3.5 mm captive screw connector,
6 pole for IR (port is shared with power input);
TTL level (0 to 5 V) modulated infrared control from 30 kHz
up to 60 kHz
CONTROL — REMOTE VOLUME (VC MODELS ONLY)
Volume control port ........................................ (1) 3.5 mm direct insertion captive screw connector, 3 pole
Pin confi guration ............................................ 1 = +10 VDC, 50 mA (max); 2 = volume (variable voltage);
3 = GND
Volume control voltage range .......................... 0 V (mute) to 10 V (maximum volume)
GENERAL
External power supply......................................... 100 VAC to 240 VAC, 50/60 Hz, external; to 12 VDC, 2 A,
regulated
Power input requirements ................................... 12 VDC, 0.15 A
Mounting
MLC 52 RS MK, MLC 52 RS VC MK ................ Mounts to a standard 47 mm deep MK electric type British
standard wall box
Enclosure type ................................................... Metal
Enclosure dimensions MLC 52 RS MK
Faceplate .................................................. 3.4" H x 3.4" W x 0.1" D
8.5 cm H x 8.5 cm W x 0.3 cm D
(1-gang MK electric type British Standard wall box frame size)
GENERAL (CONT.)
Device ........................................................... 2.7" H x 1.7" W x 1.4" D
(6.8 cm H x 4.3 cm W x 3.5 cm D) (Overall rear dimensions, including connectors. Allow at least 1.85" [4.7 cm] depth in the wall or furniture for device
and cable clearance.) MLC 52 RS VC MK
Faceplate ...................................................... 3.4" H x 5.7" W x 0.1" D
8.5 cm H x 14.6 cm W x 0.3 cm D
(2-gang MK electric type British Standard wall box frame size)
Device ........................................................... 2.7" H x 3.3" W x 1.4" D
(6.8 cm H x 8.4 cm W x 3.5 cm D)
(Overall rear dimensions, including connectors. Allow at
least 1.85" [4.7 cm] depth in the junction box for device and
cable clearance.)
Product weight ................................................... MLC 52 RS MK 0.2 lb (0.1 kg)
MLC 52 RS VC MK 0.3 lb
Shipping weight ................................................. 3 lbs (2 kg)
Vibration ............................................................ ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety ......................................................... CE, CUL, UL
EMI/EMC .................................................... CE, C-tick, FCC Class A, ICES, Section 508 of the
Rehabilitation Act (29U.S.C.794d), VCCI Class A
MTBF ................................................................ 30,000 hours
Warranty ............................................................ 3 years parts and labor
NOTE: All nominal levels are at ±10%
Model Version Description Part Number
Two-Gang
MLC 52 RS MK White Faceplate ............................................................................ 60-744-23
MLC 52 RS MK Brushed Aluminum Faceplate ........................................................ 60-744-24
Two-Gang with Integrated Volume Control Knob
MLC 52 RS VC MK White Faceplate ............................................................................ 60-745-23
MLC 52 RS VC MK Brushed Aluminum Faceplate ........................................................ 60-745-24
Optional Accessories
CFG Cable 9 DB Female-2.5 mm TRS Confi g Cable - RS Version Only ................ 70-335-01
IPL T S2 Two Serial Port IP Link Ethernet Control Interface .............................. 60-544-01
IR Link Wall-Mountable IR Signal Repeater .................................................. 60-404-02
IR Sensor Remote IR Receiver ......................................................................... 70-223-01
Included Accessories
EPS 1210B 100-240VAC, 50/60Hz, to 12VDC,2A, wire ...................................... 70-055-01
MLC 52 Series
Button Labels Text and Icon Labels ....................................................................... 33-1262-01
International Labels MediaLink International Faceplate Labels ......................................... 33-1167-0X
IR Emitter and Shield Kit IR Emitter Kits ................................................................................. 70-283-01
Loading...