Extron electronic MKP 2000 User Manual

User’s Manual
www.extron.com
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805 USA
714.491.1500 Fax 714.491.1517
Extron Electronics, Europe
© 2005 Extron Electronics. All rights reserved.
Extron Electronics, Asia
135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.6383.4400 Fax +65.6383.4664
Extron Electronics, Japan
Kyodo Building 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 Fax +81.3.3511.7656
MKP 2000
Remote Control Panel
68-971-01 Rev. A
01 05
Precautions
Safety Instructions • English
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
Caution
Read Instructions • Read and understand all safety and operating
instructions before using the equipment.
Retain Instructions • The safety instructions should be kept for future
reference.
Follow Warnings • Follow all warnings and instructions marked on the
equipment or in the user information.
Avoid Attachments • Do not use tools or attachments that are not
recommended by the equipment manufacturer because they may be hazardous.
Consignes de Sécurité • Français
Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel contient des instructions importantes concernant l’exploitation et la maintenance (réparation).
Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de tensions dangereuses non isolées posant des risques d’électrocution.
Attention
Lire les instructions• Prendre connaissance de toutes les consignes de
sécurité et d’exploitation avant d’utiliser le matériel.
Conserver les instructions• Ranger les consignes de sécurité afin de
pouvoir les consulter à l’avenir.
Respecter les avertissements • Observer tous les avertissements et
consignes marqués sur le matériel ou présentés dans la documentation utilisateur.
Eviter les pièces de fixation • Ne pas utiliser de pièces de fixation ni
d’outils non recommandés par le fabricant du matériel car cela risquerait de poser certains dangers.
Sicherheitsanleitungen • Deutsch
Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und die einen elektrischen Schock verursachen können, herrschen.
Achtung
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden,
sollten Sie alle Sicherheits-und Bedienungsanleitungen genau durchlesen und verstehen.
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit
des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und
Anleitungen auf dem Gerät oder in der Benutzerdokumentation.
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte,
die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.
Instrucciones de seguridad • Español
Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de operación y mantenimiento (o cambio de partes) que se desean destacar en el contenido de la documentación suministrada con los equipos.
Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja o alojamiento del producto, y que puedan representar riesgo de electrocución.
Precaucion
Leer las instrucciones • Leer y analizar todas las instrucciones de
operación y seguridad, antes de usar el equipo.
Conservar las instrucciones • Conservar las instrucciones de seguridad
para futura consulta.
Obedecer las advertencias • Todas las advertencias e instrucciones
marcadas en el equipo o en la documentación del usuario, deben ser obedecidas.
Evitar el uso de accesorios • No usar herramientas o accesorios que no
sean especificamente recomendados por el fabricante, ya que podrian implicar riesgos.
Warning
Power sources • This equipment should be operated only from the power source
indicated on the product. This equipment is intended to be used with a main power system with a grounded (neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or disable it.
Power disconnection • To remove power from the equipment safely, remove all
power cords from the rear of the equipment, or the desktop power module (if detachable), or from the power source receptacle (wall plug).
Power cord protection • Power cords should be routed so that they are not likely to
be stepped on or pinched by items placed upon or against them.
Servicing • Refer all servicing to qualified service personnel. There are no user-
serviceable parts inside. To prevent the risk of shock, do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards.
Slots and openings • If the equipment has slots or holes in the enclosure, these are
provided to prevent overheating of sensitive components inside. These openings must never be blocked by other objects.
Lithium battery • There is a danger of explosion if battery is incorrectly replaced.
Replace it only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Avertissement
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation
indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fil de terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la désactiver.
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger,
déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de
manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des objets.
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-
maintenance par un technicien qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.
Fentes et orifices • Si le boîtier de l’appareil comporte des fentes ou des orifices,
ceux-ci servent à empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais être bloquées par des objets.
Lithium Batterie • Il a danger d'explosion s'll y a remplacment incorrect de la
batterie. Remplacer uniquement avec une batterie du meme type ou d'un ype equivalent recommande par le constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.
Vorsicht
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene
Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen,
sollten Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht
im Weg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden können.
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifiziertem
Servicepersonal durchgeführt werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse
aufweist, dienen diese zur Vermeidung einer Überhitzung der empfindlichen Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten blockiert werden.
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird.
Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.
Advertencia
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo
de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puentearia ni eliminaria.
Desconexión de alimentación eléctrica • Para desconectar con seguridad la
acometida de alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el cable del receptáculo de la pared.
Protección del cables de alimentación • Los cables de alimentación eléctrica se
deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal
calificado. En el interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no intentar personalmente la reparación/ mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento,
es para evitar el sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir con otros objetos.
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición
incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante. Desachar las baterías usadas siguiendo las instrucciones del fabricante.
Extron’s Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, Europe, Africa, and the Middle East: and Central America:
Extron Electronics Beeldschermweg 6C
1001 East Ball Road 3821 AH Amersfoort
Anaheim, CA 92805, USA The Netherlands
Asia: Japan:
Extron Electronics, Asia Extron Electronics, Japan 135 Joo Seng Road, #04-01 Kyodo Building PM Industrial Bldg. 16 Ichibancho Singapore 368363 Chiyoda-ku, Tokyo 102-0082
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions or non-Extron authorized modification to the product.
If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), 65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
Extron Electronics, Europe
Japan
Quick Start Guide — MKP 2000
Install and set up the MKP 2000 as follows:
Step 1
Turn all of the equipment of f and disconnect it from the power source.
Step 2
Install the cables to and from the control panel in a wall, podium, or desk. See Rear Panel and Side Panel Connections in chapter 2, Installation, for guidelines.
Step 3
Prepare the wall, podium, desk, or other surface to mount the MKP. See Preparing the site, installing the mud ring or wall box in chapter 2, Installation.
Step 4
Install the control panel in a wall, podium, desk, or other surface. See Mounting the MKP to the mud ring or wall box in chapter 2, Installation.
Step 5
Connect the input and output cables. See Rear Panel and Side Panel Connections in chapter 2, Installation, for guidelines.
Step 6
Connect the power supply. See Power supply wiring in chapter 2, Installation.
Step 7
Connect power cords and turn on the equipment in the following order: output devices (such as projectors or monitors), the connected matrix switcher, and input devices (such as DSSs or cable boxes).
Step 8
If necessary, set the control panel’s and matrix switcher’s IP parameters. See Viewing and configuring the IP and and MKP set-up
parameters in chapter 3, Local Operation, or System Settings Page in chapter 5, HTML Operation.
Step 9
If necessary, set the control panel’s RS-232 port for pass-through or no-pass-through mode and whether the MKP is the primary device (connected to the switcher) or secondary device (connected through another device). See Viewing and configuring the IP and and MKP set-up parameters in chapter 3, Local Operation, or System Settings Page in chapter 5, HTML Operation.
MKP 2000 Remote Control Panel • Quick Start Guide QS-1
Quick Start Guide — MKP 2000, cont’d
Table of Contents
Step 10
Program the control panel with the size of the connected switcher. See System Settings Page in chapter 5, HTML Operation.
Step 11
Use the control panel to select inputs and outputs. See Front Panel Operations in chapter 3, Local Operation.
Chapter 1 • Introduction ..........................................................1-1
About the MKP 2000 Remote Control Panel ...........1-2
RS-232 connection to the switcher ....................................... 1-3
Ethernet connection to the switcher ...................................1-3
Chapter 2 • Installation.............................................................2-1
MKP Installation Overview...............................................2-2
UL Requirements for Wall Box Installation ............. 2-3
Installation Procedures ....................................................... 2-3
Preparing the site, installing the mud ring or wall box......2-4
Mounting the MKP to the mud ring or wall box ................2-7
Rear Panel and Side Panel Connections .................... 2-8
Control connections ............................................................ 2-10
RS-232 cable termination.................................................2-11
TP cable termination ........................................................... 2-12
Power supply wiring............................................................2-14
Chapter 3 • Local Operation .................................................. 3-1
Front Panel Controls and Indications ......................... 3-2
Front Panel Operations.......................................................3-3
Creating a tie ......................................................................... 3-3
Viewing the last input or output tied from the MKP .........3-4
Viewing and configuring the IP and MKP
set-up parameters..................................................................3-4
Host control port setting and pass-through communications
Control panel security lockout (executive mode)................3-8
Rear Panel Resets .................................................................. 3-8
Performing soft resets ........................................................... 3-8
Performing a hard reset ...................................................... 3-10
...........................................3-7
QS-2
MKP 2000 Remote Control Panel • Quick Start Guide
Chapter 4 • SIS Operation .......................................................4-1
RS-232 Links..............................................................................4-2
Routing matrix switcher commands.....................................4-2
Ethernet Link ...........................................................................4-3
Default IP address.................................................................. 4-3
Host-to-MKP Instructions .................................................. 4-3
MKP-Initiated (Unsolicited) Messages........................4-3
MKP Error Responses...........................................................4-4
Using the Command/Response Table ..........................4-4
iMKP 2000 Remote Control Panel• Table of Contents
Table of Contents, cont’d
Symbol definitions for MKP SIS commands ......................... 4-6
Command/response table for MKP SIS commands..............4-8
Chapter 5 • HTML Operation..................................................5-1
Dowload the Startup Page ...............................................5-2
System Status Page .............................................................. 5-4
System Settings Page..........................................................5-5
IP Settings section.................................................................. 5-6
Unit Name field .................................................................5-6
DHCP radio buttons ........................................................... 5-6
IP Address field .................................................................. 5-6
Gateway IP Address field ................................................... 5-6
Subnet Mask field..............................................................5-6
MAC Address field ............................................................. 5-6
Switcher Settings section ...................................................... 5-7
MKP Connection Priority settings ......................................5-7
Host Control Port settings ................................................. 5-7
Switcher IP settings............................................................5-7
Switcher Size settings ........................................................ 5-7
Authorized inputs and authorized outputs ....................... 5-8
Front panel configuration lock.......................................... 5-8
Date/Time Settings fields ....................................................... 5-8
Port (RS-232) Settings Page .............................................5-9
Passwords Page .................................................................... 5-10
Firmware Upgrade Page ..................................................5-11
File Management Page ..................................................... 5-13
Special Characters...............................................................5-14
Appendix A • Reference Data.............................................. A-1
Specifications ......................................................................... A-2
Part Numbers.......................................................................... A-3
Included parts ....................................................................... A-3
Installation accessories ......................................................... A-3
Cables .................................................................................... A-3
Mounting and Cabling Specifications ....................... A-4
Electrical box cutout............................................................. A-4
Panel mount cutout template ............................................. A-4
Extron Comm-Link cable ...................................................... A-6
MKP 2000 Remote Control Panel
Chapter One
1
Introduction
About the MKP 2000 Remote Control Panel
All trademarks mentioned in this manual are the properties of their respective owners.
ii
MKP 2000 Remote Control Panel • Table of Contents
68-971-01 A
01 05
Introduction
This manual provides installation and operation instructions for the Extron MKP 2000.
About the MKP 2000 Remote Control Panel
The MKP 2000 is a network-ready remote control panel that can control any Extron matrix switcher. The MKP’s RS-232 ports allow it to communicate with other devices (another MKP or a matrix switcher) locally and its Ethernet port allows it to communicate with multiple devices.
An MKP 2000 user can remotely create ties by specifying an input and then an output to be tied to the input. The MKP can also be dedicated to a specific group of inputs and outputs when configured using the built-in Web pages.
The MKP 2000 is mounted in a two-gang wall plate that can be installed in a wall, conference table, podium, or other convenient location.
Although the matrix switcher system can have up to 128 inputs and 128 outputs, a conference room may have 3 input devices and 2 output devices, a training room next door may have 4 input devices and 1 output device, and so on. Typically, each room will have one or more MKP control panels assigned to it, with each MKP limited to the inputs and outputs that it can control. In the example in Figure 1-1, the “presentation room” (top center) has one output device, projector (C) and four input devices: a video camera (13), a laptop computer (12) and two PCs (11 and 14). The “Media Room” contains the matrix switcher, as well as other inputs (1-6) and possibility some control device(s).
Input
13
C
12
Video Conference Room
Input
10
Input
7-9
Input
11
A
B
s c
i on r
n t
o x
tr E c le E
123
456
INPUT OUTPUT
789
TAKE
BACK 0
CANCEL
MKP 2000
Figure 1-1 — Typical MKP 2000 applications
An overflow crowd in the video conference room and/or the training room may need to see a lecture going on in the presentation room. In this case, the video camera (input 13) must be available to those other rooms, so the MKPs in the video conference and training rooms will be programmed to allow selection of input 13 for displays in those rooms, in addition to any video sources and/or displays in those rooms.
RS-232 connection to the switcher
Any number of MKP 2000s can be connected to a matrix switcher through its RS-232 port, but one MKP must be designated as the primary controller. Other MKPs can be daisy chained through the primary MKP remote control panel.
Presentation Room
Input
MKP-2000 Keypad
14
Training Room
D
Input
1-6
Media Room
P l
a y
e
V
r
C
1
P
R
la
y e
D
r
V
2
P
D
la
y e
V
r
C
3
R
D
S S
L
D
a
e
s
RED
v
e
i
r c e
C o
GR
n
C
t
r
O
EE
o
ll
M
e
N
P
r
A
C
Q
O
P
B
M
C
LU
P
A
C
E
Q
HO
O
M
P
RIZ
C
P A
Q
O N
P
TAL S
C
V
ER
ync
TICA
L Sync
AU
D IO
Ethernet connection to the switcher
Any number of MKP 2000s can be connected to a matrix switcher as part of an Ethernet local area network (LAN).
1-2 1-3
MKP 2000 Remote Control Panel • Introduction
MKP 2000 Remote Control Panel • Introduction
Introduction
Chapter Two
2
1-4
MKP 2000 Remote Control Panel • Introduction
Installation
MKP Installation Overview
UL Requirements for Wall Box Installation
Installation Procedures
Rear Panel and Side Panel Connections
MKP 2000 Remote Control Panel • Introduction
Installation
CAUTION
Installation and service must be performed by authorized personnel only. UL Listed electrical boxes are recommended. See UL Requirements
for Wall Box Installation on the next page.
The MKP 2000 remote control panel should be installed in a standard, 2-gang electrical wall box (figure 2-1). Figure 2-1 shows the MKP installed in a wall. This could also be in a desk, a podium, or any other convenient location.
The procedures provided here assume that the electrical wall boxes and the cables have been installed for the system. Rear Panel and Side Panel Connections, starting on page 2-8 provides guidance for terminating the cables.
MKP Installation Overview
To install an MKP 2000 remote control panel, follow these steps:
Disconnect power from the matrix switcher and all MKPs
1
in the system. Prepare the site: cut a hole in the wall/furniture, install
2
the electrical box or mud ring, and prepare the cables. Instructions are included in this manual and/or with the wall box. See Preparing the site, installing the mud ring or wall box in this chapter.
Connect the cable between the MKP and the
3
matrix switcher. See Rear Panel and Side Panel Connections on page 2-8.
UL Requirements for Wall Box Installation
The following Underwriters Laboratories (UL) requirements pertain to the installation of the MKP 2000 into a wall or furniture (figure 2-1).
23
OUTPUT
1
6
INPUT
5
R
4
9
TAKE
8
EL
7
CANC
0
K C A
B
Figure 2-1 — MKP mounted in a wall box
1. These units are not to be connected to a centralized DC
power source or used beyond their rated voltage range.
2. These units must be installed in UL listed junction boxes.
3. These units must be installed with conduit in accordance
with the National Electrical Code.
0
200
MKP
2-2
Connect power cords to the MKP and the matrix switcher.
4
Test the MKP’s ability to communicate with the matrix
5
switcher. Disconnect power from all the devices.
6
Mount the MKP into the electrical box or to the mud ring.
7
If using a wall box, see Mounting the control panel to the mud ring or wall box in this chapter.
Restore power to the devices.
8
MKP 2000 Remote Control Panel • Installation
Installation Procedures
The MKPs are mounted into a wall, furniture, or any other convenient location. Follow the instructions appropriate to the mounting option you have selected.
CAUTION
MKP 2000 Remote Control Panel • Installation
The control panel must be installed into an Underwriters Laboratories (UL) approved electrical wall box.
When installing MKP control panels, you must conform to all national and local electrical codes.
2-3
Installation, cont’d
Preparing the site, installing the mud ring or wall box
Choose a location that allows cable runs without interference. Allow enough depth for both the wall box and the cables. You may need to install the cables into the wall, furniture, or conduits before installing the control panel.
The installation must conform to national and local electrical codes and to the equipment’s size requirements. An actual-size cut-out template that shows the cutout requirement for the circuitry enclosure on the rear of the control panel is provided in appendix A of this manual.
Installation using a UL listed wall box (available from Extron) is recommended for most mounting options, but the included mud rings can be used instead.
Before using the mud rings, verify that the installation conforms to national and local electrical codes.
CAUTION
Install the mud ring or wall box as follows: 1a. If you are using a mud ring, use the template that came
with the mud ring. Cut out the indicated center portion.
1b. If you are using a wall box, cut out or make a 100% size
photocopy of the cut-out template in appendix A that corresponds to the faceplate you are using, and cut out the center portion of it as indicated on the template.
2. Place the template (or the wall box or mud ring) against
the installation surface, and mark the guidelines for the opening on the wall or furniture.
3. Cut out the wall/furniture material from the marked area.
4. Check the opening size by inserting the wall box, mud
ring, or control panel into the opening. The box or mud ring (if used) and/or control panel should fit easily into the opening. Enlarge or smooth the edges of the opening if needed.
Extron provides one mud ring with each MKP control panel. However, the user may choose to use a wall box. Because the tolerances on electrical boxes are very loose, it is recommended that you measure the actual box that you plan to use before making any precise cuts.
The electrical box must be at least 2.5" (7 cm) deep to accommodate the MKP’s rear enclosure.
To meet the UL listing requirements, this device must be installed in a wall box.
5. If you are using a wall box, feed cables through the wall
box punch-out holes, and secure them with cable clamps to provide strain relief.
6. Exposed cable shields (braids or foil) are potential sources
of short circuits. Trim back and/or insulate shields with heat shrink (figure 2-2).
Wall Stud
Screws or Nails
Cable Clamp
Foil Shield
Installation Cable
Screw
Braided Shield
Figure 2-2 — Grounding outer braided and foil shields
To prevent short circuits, the outer foil shield can be cut back to the point where the cable exits the cable clamp. Both braided and foil shields should be connected to an equipment ground at the other end of the cable.
MKP 2000 Remote Control Panel • Installation
MKP 2000 Remote Control Panel • Installation
2-52-4
Installation, cont’d
Flush with Wall Surface
Screws or Nails
Wall Stud
Wall Box
7a. If you are using a mud ring, follow the directions, if any,
that came with the mud ring to attach the clips that fasten the ring to the wall or furniture (figure 2-3).
To meet the UL listing requirements, this device must be installed in a wall box.
Sheet Rock
Backing Clip
0.75" #6-32 Screw
Sheet Rock
Backing Clip
1.25" #6-32 Screw
Backing Clip can
be in either orientation.
See Detail A or Detail B.
Mounting Bracket
Detail A
Detail B
Mounting Bracket
R
3
T U P
T
2
U
1
6
TO
U
P N I
5
E
K
4
A T
89
L
E
C
7
N
A
C
0
K C A
B
0
0
2
P
K
M
Extron MKP 2000
Figure 2-3 — Attaching a mud ring to a wall
7b. If you are using a wall box, insert the wall box into the
opening, and attach it to the wall stud/furniture with nails or screws, leaving the front edge flush with the outer wall or furniture surface (figure 2-4).
If attaching the wall box to wood, use four #8 or #10 screws or 10-penny nails. A minimum of 1/2 inch (1.3 cm) of screw threads must penetrate the wood.
If attaching the wall box to metal studs or furniture, use four #8 or #10 self-tapping sheet metal screws or machine bolts with matching nuts.
Figure 2-4 — Attaching a wall box to a wall stud
8. Connect the Ethernet and/or RS-232 cable (as appropriate)
and the power cable and test the MKP before fastening the
0
MKP into the wall box. See Rear Panel and Side Panel Connections on page 2-8, for details.
The rear panel connectors will be inaccessible after installation.
Mounting the MKP to the mud ring or wall box
1. Remove power from the control panel by disconnecting
the power supply.
2. Place the control panel through the opening in the wall or
furniture and into the wall box. Take care not to damage the cables, which fit behind the MKP, at the back of the wall box.
2-6
MKP 2000 Remote Control Panel • Installation
MKP 2000 Remote Control Panel • Installation
2-7
Installation, cont’d
3. Mount the MKP’s faceplate to the mud ring or wall box
with machine screws (figure 2-5).
23
OUTPUT
1
6
INPUT
5
R
4
9
TAKE
8
EL
7
CANC
0
K C A
B
0
P 200
K
M
Figure 2-5 — Mounting the MKP to the wall box
4. Reconnect the power supply and restore power.
Rear Panel and Side Panel Connections
All connectors are on the rear or side of the MKP (figure 2-6). These connectors will be inaccessible once the MKP is installed.
LAN (Ethernet) port — If desired, connect a Category (CAT) 5e
1
or higher (network) cable between this connector and either the matrix switcher to be controlled or to an Ethernet local area network (LAN).
LAN
See TP cable termination, on page 2-12, to properly wire the RJ-45 connector for your application.
Ethernet connection indicators The Link and Act LEDs indicate the status of the Ethernet connection. The Link LED indicates that the MKP is properly connected to an Ethernet LAN. This LED should light steadily. The Act LED indicates transmission of data packets on the RJ-45 connector. This LED should flicker as the MKP communicates.
Host RS-232 port — If desired, connect a host computer or
2
control system to this 3-pole, 3.5 mm, RS-232 connector (figure 2-7).
HOST
RS-232
SWITCH
RS-232
GND
GND
Tx
Rx
Tx
Rx
Pin Function
TX
Transmit data
RX
Receive data
Gnd
Signal ground
Figure 2-7 — RS-232 connector
Switcher RS-232 port — If desired, connect a cable between this
3
3-pole, 3.5 mm, RS-232 connector and a matrix switcher (figure 2-7).
RS-232
SWITCH
RS-232
Tx
HOST
Rx
GND
Tx
Rx
GND
12 VDC
GND
1
2
LAN
TWEEKER TO REMOVE
PRESS TAB WITH
3
4
HOS
RS-232
T
Tx
Rx
GND
SWI
TCH
Tx
RS-232
Rx
GND
12 VDC
GND
Figure 2-6 — MKP rear and side panels
MKP 2000 Remote Control Panel • Installation
Power connector — Plug the included external 12 VDC power
4
supply into this 2-pole captive screw connector. See Power supply wiring, on page 2-14 to wire the connector.
LAN
TWEEKER TO REMOVE
PRESS TAB WITH
MKP 2000 Remote Control Panel • Installation
2-92-8
Installation, cont’d
Control connections
The MKP has two RS-232 ports; a Host port (1) and a Switcher port (2); and an Ethernet (LAN) port (3).
An MKP control panel can be directly connected to any Extron matrix switcher through the switcher’s RS-232 port (figure 2-8). A control system or host computer can be connected via the MKP’s host RS-232 port. Additional MKPs can be connected to the matrix switcher through the MKP that is RS-232 connected to the switcher (the primary MKP). The additional (secondary) MKPs are connected to the primary MKP via the primary MKP’s Ethernet port.
123
456
INPUT OUTPUT
789
TAKE
CANCEL
BACK 0
MKP 2000
MKP 2000
123
456
INPUT OUTPUT
789
TAKE
CANCEL
BACK 0
MKP 2000
MKP 2000
Figure 2-8 — MKP connection using the RS-232 port
An MKP control panel can be directly connected to any Ethernet-enabled matrix switcher via the switcher’s Ethernet port (figure 2-9) using a network (TP) cable that is wired as a crossover cable (see TP cable termination to properly wire the cable).
123
456
789
BACK 0
MKP 2000
Figure 2-9 — Direct MKP connection using the LAN port
LAN Port
INPUT OUTPUT
TAKE
CANCEL
Crossover
MKP 2000
Cable
MKP 2000
123
456
INPUT OUTPUT
789
TAKE
CANCEL
BACK 0
MKP 2000
Ethernet
123
456
INPUT OUTPUT
789
TAKE
CANCEL
BACK 0
MKP 2000
MKP 2000
I
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
N P U T S
O U T P U T S
Matrix Switcher
Ethernet
CONTROL
MAV 2400 SERIES SWITCHER
Matrix Switcher
I
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
N P U T S
O U T P U T S
Switcher RS-232 Port
123
456
INPUT OUTPUT
789
TAKE
CANCEL
BACK 0
MKP 2000
MKP 2000
Host RS-232 Port
Control System
I/O
Any number of control panels can be connected, as part of a network, to any Ethernet-enabled matrix switcher via the switcher ’s Ethernet port (figure 2-10). All TP cables in this example are wired as patch (straight) cables.
MKP 2000
123
456
INPUT OUTPUT
123
456
789
BACK 0
INPUT OUTPUT
TAKE
CANCEL
MKP 2000
789
BACK 0
TAKE
CANCEL
MKP 2000
MKP 2000
I
123
456
INPUT OUTPUT
789
TAKE
CANCEL
I/O
CONTROL
MAV 2400 SERIES SWITCHER
BACK 0
MKP 2000
MKP 2000
Ethernet
Patch Cable
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
Matrix Switcher
N P U T S
I/O
CONTROL
O U T P U T S
MAV 2400 SERIES SWITCHER
PC
Figure 2-10 — Network MKP connection using the LAN port
RS-232 cable termination
Each MKP control panel has two RS-232 ports that are connected using 3.5 mm, 3-pole direct insertion connectors. Wire the connectors as follows:
The total cable length between an MKP control panel and a matrix switcher should not exceed 100 feet (30 m).
1. Choose a cable such as Extron’s Comm-Link cable. The
wire specifications for Comm-Link cable are on page A-6. Colors may vary from this example.
2. Trim approximately 1.5" (3.8 cm) of the cable jacket to
expose the four insulated wires and a bare drain wire (silver-colored).
3. Cut off the foil shield and discard it.
4. Strip 1/4" ( 0.6 cm) of insulation from three of the four
wires.
5. Twist the strands of each wire, insert them into the direct
insertion connector, and tighten the captive screws.
MKP 2000 Remote Control Panel • Installation
MKP 2000 Remote Control Panel • Installation
2-112-10
Installation, cont’d
TP cable termination
It is vital that your Ethernet cables be the correct cables, and that they be properly terminated with the correct pinout. Ethernet links use Category (CAT) 5e or CAT 6, unshielded twisted pair (UTP) or shielded twisted pair (STP) cables, terminated with RJ-45 connectors. Ethernet cables are limited to a length 328' (100 m).
Do not use standard telephone cables. Telephone cables will not support Ethernet or Fast Ethernet.
Do not stretch or bend cables. Transmission errors can occur .
The cable used depends on your network speed. The MKP supports both 10 Mbps (10Base-T — Ethernet) and 100 Mbps (100Base-T — Fast Ethernet), half-duplex and full-duplex, Ethernet connections.
10Base-T Ethernet requires CAT 3 UTP or STP cable as a minimum.
100Base-T Fast Ethernet requires CAT 5e UTP or STP cable as a minimum.
The Ethernet cable can be terminated as a straight-through cable or a crossover cable and must be properly terminated for your application (figure 2-11).
Crossover cable — Direct connection between the MKP and a host computer or an Ethernet-enabled matrix switcher (figure 2-9).
Patch (straight) cable — Network connection between the MKP and an Ethernet LAN (figure 2-10).
Patch (straight) cable
Side 1 Side 2
Pin Wire color Pin Wire color
1 White-orange 1 White-orange
1&2
Clip DownSide
1 Pins2345678
1
2345678
3&6
4&5
RJ-45 connector
7&8
Twisted Pairs
2 Orange 2 Orange 3 White-green 3 White-green 4 Blue 4 Blue 5 White-blue 5 White-blue 6 Green 6 Green 7 White-brown 7 White-brown 8 Brown 8 Brown
Crossover cable
Side 1 Side 2
Pin Wire color Pin Wire color
1 White-orange 1 White-green 2 Orange 2 Green 3 White-green 3 White-orange 4 Blue 4 Blue 5 White-blue 5 White-blue 6 Green 6 Orange 7 White-brown 7 White-brown 8 Brown 8 Brown
Figure 2-11 — RJ-45 connector and pinout tables
MKP 2000 Remote Control Panel • Installation
MKP 2000 Remote Control Panel • Installation
2-132-12
Installation, cont’d
Power supply wiring
Figure 2-12 shows how to wire the connector.
Smooth
Figure 2-12 — Power connector wiring
CAUTION
To verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter.
CAUTION
Ridges
Power Supply
Output Cord
Power supply voltage polarity is critical. Incorrect voltage polarity can damage the power supply and the MKP. Identify the power cord negative lead by the ridges on the side of the cord (figure 2-12).
The length of the exposed (stripped) copper wires is important. The ideal length is 0.2" (5 mm). Longer bare wires can short together. Shorter wires are not as secure in the direct insertion connectors and could be pulled out.
AA
SECTION A–A
12 V
Direct Insertion
Connector
MKP 2000 Remote Control Panel
0.2” (5 mm)
GND
Chapter Three
3
2-14
Do not tin the power supply leads before installing in the direct insertion connector. Tinned wires are not as secure in the connectors and could be pulled out.
The two power cord wires must be kept separate while the power supply is plugged in. Remove power before wiring.
Alternatively, an Extron P/S 100 Universal 12 VDC Power Supply, part #60-357-01, can power up to ten Extron 12 VDC devices using only one AC power connector.
MKP 2000 Remote Control Panel • Installation
Local Operation
Front Panel Controls and Indications
Front Panel Operations
Rear Panel Resets
Local Operation
Front Panel Controls and Indications
123
1
Figure 3-1 — MKP 2000 controls and indicators
0, 1 through 9 buttons — These buttons allow you to enter an
1
input or output when you create a tie. Back button — This button allows you to delete the least-
2
significant (rightmost) digit of an entered input or output number.
Cancel button — This button allows you to clear the LED
3
display to 000, erasing any number that you have entered or any error message.
Input button — This button allows you to specify that the next
4
number that you enter with the numeric keys (1) is an input. Output button — This button allows you to specify that the
5
next number that you enter with the numeric keys (1) is an output.
Take button — This button confirms the potential tie that you
6
have created with the input and output selection. This button is the equivalent of the Enter button on the matrix switcher’s front panel.
LED display — This display shows the input or output number
7
that was most-recently entered using the MKP’s numeric keys (1). In certain modes, it can also show the various IP addresses programmed into the MKP.
456
789
BACK 0
BACK 0
2 63 54
CANCEL
CANCEL
INPUT OUTPUT
TAKE
MKP 2000
The LED display shows the most recent input or output number entered on the numeric keys only. Ties created using other devices (other MKPs, a PC or control system, or the matrix switcher’s front panel) are not shown in the LED display.
Front Panel Operations
7
Creating a tie
1. Press the Input button to specify that the next number
entered is an input number.
The Input LED lights.
The LED display shows the last input selected from this MKP.
The last selected output is locked (unable to be changed; assigned as the output to which the entered input is tied unless a different output is assigned [see steps 3 and 4]).
2. Use the numeric keys to enter the desired input.
The LED display shows the input that you enter.
The Take LED blinks.
If you push the Take button now, the selected input is tied to the locked output.
3. Press the Output button to specify that the next number
entered is an output number.
The Output LED lights.
The LED display shows the last output selected from this MKP.
The last selected input is locked (unable to be changed; assigned as the output to which the entered input is tied unless a different input is assigned [see steps 1 and 2]).
4. Use the numeric keys to enter the desired output.
The LED display shows the output that you enter.
The Take LED blinks.
5. Press the Take button to confirm the change.
The Take LED goes out.
The LED display show the last output that was tied from this MKP.
3-2
MKP 2000 Remote Control Panel • Local Operation
MKP 2000 Remote Control Panel • Local Operation
3-3
Local Operation, cont’d
When an input or output outside the available range for this MKP or the connected matrix switcher is selected, the LED display shows N-A.
Viewing the last input or output tied from the MKP
Press either the Input button or the Output button.
The Input or Output LED lights.
The LED display shows the last tied input or output (depending on which LED, Input or Output, is lit).
The LED display shows the most recent input or output number entered on the numeric keys only. Ties created using other devices (other MKPs, a PC or control system, or the matrix switcher’s front panel) are not shown in the LED display.
Viewing and configuring the IP and MKP set-up parameters
To configure the MKP to operate in your LAN system, one or more of the following IP addresses and the host control port setting may need to be changed:
The MKP’s IP address (default = 192.168.254.253)
The MKP’s subnet address (default = 255.255.0.0)
The MKP’s gateway address (default = 0.0.0.0)
The target matrix switcher’s IP address (default = 0.0.0.0)
Host control port setting (pass-through or no pass­through) (default = no pass-through)
MKP’s connection setting
Primary — Controls the switcher directly. Secondary — Controls the switcher through another
MKP and its Switcher RS-232 port.
Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields (octets) separated by dots (periods). Each octet can be numbered from 000 through 255. Leading zeroes, up to 3 digits total per octet, are optional. Values of 256 and above are invalid.
If any of the default address conflict with other equipment at your installation, you can change the IP address(es) to any valid value.
Editing the Extron IP address and other parameters while connected via the LAN port can immediately disconnect the user from the MKP. Extron recommends editing this field using the front panel or the RS-232 link
and protecting the Ethernet access to these parameters by assigning an administrator’s password to qualified and knowledgeable personnel only.
Edit these addresses and set the host control setting as follows:
1. Simultaneously press and hold the Input, Output, and
Take buttons for approximately 2 seconds until the LED display changes and then release the buttons.
The LED display shows the most-significant (left-most) octet of the MKP’s IP address (figure 3-2 on page 3-6).
Pressing the Input button changes the IP address shown in the LED display, cycling through the various IP addresses, and then selects the host control setting, as shown in figure 3-2.
The Input LED is lit and the Output LED is
unlit when the MKP’s IP address is displayed.
The Input LED is unlit and the Output LED is
lit when the MKP’s subnet mask is displayed.
The Input LED is blinking and the Output LED
is unlit when the MKP’s gateway IP address is displayed.
The Input LED is unlit and the Output LED is
blinking when the MKP’s target matrix switcher ’s IP address is displayed.
Both the Input LED and the Output LED are lit
when the host control setting is displayed.
Both the Input LED and the Output LED are
blinking when the connection priority is displayed.
Pressing the Output button changes the octet of the selected IP address that is shown in the LED display, cycling through the four octets as shown in figure 3-2.
No dot (period) appears in the LED display
when the most-significant octet is shown.
A dot (period) appears to the right of the left-
most digit in the LED display when the second octet is shown.
A dot (period) appears to the right of the second
digit in the LED display when the third octet is shown.
A dot (period) appears to the right of the right-
most digit in the LED display when the least­significant octet is shown.
MKP 2000 Remote Control Panel • Local Operation
MKP 2000 Remote Control Panel • Local Operation
3-53-4
Local Operation, cont’d
editable addresses and to reach the MKP set-up settings.
Press the Input button to cycle through the displayed and
Simultaneously press and hold
the buttons for 2 seconds.
Release the buttons.
INPUT OUTPUT
TAKE
INPUT
MKP 2000’s
IP Address
INPUT
MKP 2000’s
Subnet Mask
Matrix
INPUT
INPUT
INPUT
INPUT
MKP 2000’s
Gateway
Address
Switcher’s
IP Address
Host Control
Setting
Connection
Priority
Figure 3-2 — Selecting octet fields and host control
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
The LED display shows the most-significant octet of the MKP 2000’s IP address.
Press the Output button to cycle through the displayed and editable octets.
OUTPUT
1 9 21 6 8.2
5
2
0
0
0
0
Most-significant Octet (no dot)
OP
n
No
Pass-through
OUTPUT OUTPUT
OUTPUT OUTPUT OUTPUT
5
.
52 5 5.0
00 0 0.0
00 0 0.
.
.
.
42 5 3..
.
0
00 0 0..
.
0
00 0 0..
.
0
00 0 0..
.
Least-significant Octet
(dot in right-most position)
PA S
Por t
Pass-through
SECPri
Connected to
Switcher
OUTPUT OUTPUT
Control Though
Primary (RS-232)
2. Use the Input button and Output button to select and
display the desired address and octet.
3. Press the Cancel button to clear the octet to 000.
4. Use the 0 through 9 buttons to enter the desired value for
the octet.
5. Repeat steps 2 through 4 to select and change other
addresses and/or octets.
6. Use the Input button to select the host control setting
display.
7. If necessary, use the Output button to toggle the setting
.
.
.
Host control port setting and pass-through communications
.0
between pass-through and no pass-through.
8. Use the Input button to select the connection priority
display.
9. If necessary, use the Output button to toggle the setting
between primary and secondary.
10. When all addresses and octets and the host control and
priority settings are correct, press the Take button.
When the MKP is:
Connected to a computer or control system via its Host
RS-232 port and
Is in pass-through mode,
The MKP redirects valid matrix switcher SIS commands that it receives on its Host RS-232 port to its Switcher RS-232 port.
When the MKP is:
Connected to a computer or control system via its Host
RS-232 port and
Is in no pass-through mode,
The MKP acts on all valid MKP commands received. It does not pass the command to its Switcher RS-232 port.
When the MKP is:
Selected as primary, it directly controls the matrix switcher via its Switch RS-232 port or LAN port
Selected as secondary,
The MKP controls the matrix switcher through connection to the
primary MKP’s IP address
3-6 3-7
MKP 2000 Remote Control Panel • Local Operation
MKP 2000 Remote Control Panel • Local Operation
Local Operation, cont’d
Control panel security lockout (executive mode)
The front panel security lockout limits the MKP’s front panel operation to input and output selection only (IP address modification is locked).
To toggle the lock on and off, press and hold the 1, 3, Back, and Cancel buttons for approximately 3 seconds until the LED display shows the appropriate “LOC” (on or off) message (figure 3-3). When the MKP lock is turned on, the LED display shows “LOC” for three seconds and then “ON” for three seconds. When the lock is turned off, the LED display shows “LOC” and then “OFF” for 3 seconds.
Simultaneously press
and hold the buttons.
1 3
3
seconds
BACK CANCEL
The LED display shows
the LOC message.
3
seconds
LOC ON
Figure 3-3 — Control panel lockout
Rear Panel Resets
Performing soft resets
The remote control panel has three soft resets available that restore various tiers of MKP settings to their default settings.
Events (mode 3) reset — This function restarts the
communications and control events.
IP system (mode 4) reset — IP system reset function
resets most IP protocols to their default settings.
IP system reset clears the Internet protocol (IP) settings, but does not reset the target address, the host control setting, the priority setting, or any user-loaded files.
Absolute (mode 5) reset — Absolute reset performs all of the system reset functions and clears the MKP’s IP address to 192.168.254.253 and subnet mask to
255.255.0.0. This function is identical to the
Esc
ZQQQ SIS command, see chapter 4, SIS Operation).
Perform a soft reset of the MKP as follows:
1. Press and hold the Reset (R) button until the Reset LED
blinks off once (events reset), twice (IP system reset), or three times (absolute reset) (figure 3-4).
R
Press and hold the Reset button.
Events
(Mode 3)
Reset
3 seconds
R
LED flashes
once.
R
Release, then
immediately
press and release again.
R
Press and hold the Reset button.
IP System
(Mode 4)
Reset
6 seconds
R
LED flashes
twice.
R
Release, then
immediately
press and release again.
R
Press and hold the Reset button.
Absolute
(mode 5)
Reset
9 seconds
R
LED flashes
three times.
R
Release, then
immediately
press and release again.
Figure 3-4 — Soft resets
2. Release the Reset button and then immediately press and
release the Reset button again. Nothing happens if the second momentary press does not occur within 1 second.
3-8
MKP 2000 Remote Control Panel • Local Operation
MKP 2000 Remote Control Panel • Local Operation
3-9
Local Operation, cont’d
Performing a hard reset
The hard reset function restores the MKP to the original factory default settings, including the default (factory) firmware configuration and the default IP settings. A hard reset performs all of the reset-whole-MKP functions, absolute reset functions, and erases all user-installed software or firmware. Perform a hard reset as follows:
Ensure that you have backed up any locally-created HTML, JavaScript, or other files that you have uploaded to the MKP’s user file space before you perform the hard reset. A hard reset will erase all locally-created files from the MKP.
1. If necessary, turn off power to the switcher.
2. Press and hold the Reset button on the rear panel while
you apply AC power to the MKP (figure 3-5).
Press and hold the Reset button while you apply power to the MKP.
R
The LED flashes on and off.
MKP 2000 Remote Control Panel
Chapter Four
4
Power
3-10
Release the Reset button.
R
Figure 3-5 — Hard reset
MKP 2000 Remote Control Panel • Local Operation
SIS Operation
RS-232 Links
Ethernet Link
Host-to-MKP Instructions
MKP-Initiated (Unsolicited) Messages
MKP Error Responses
Using the Command/Response Table
SIS Operation
RS-232 Links
The MKP’s rear panel 3-pole, 3.5 mm, Host RS-232 connector (figure 4-1) can be connected to the RS-232 serial port output of a host device such as a computer running the HyperTerminal utility, an RS-232 capable PDA, or a control system. This connection makes software control of the control panel possible. The rear panel Switcher connector can be connected to the Remote or RS-232 port of a matrix switcher.
The default protocol for both ports is as follows:
9600 baud* no parity
8-bit, 1 stop bit no flow control
Tx
HOST
Rx
RS-232
GND
Tx
SWITCH
Rx
RS-232
GND
Figure 4-1 — RS-232 connector pin assignments
Routing matrix switcher commands
When the MKP is connected to the matrix switcher via its Switcher RS-232 port, the MKP can redirect SIS matrix switcher commands received on the Host RS-232 port to the matrix switcher.
If the MKP receives a valid matrix switcher SIS command on its Host RS-232 port, it redirects the command to its Switcher RS-232 port only if the MKP is set to Pass-through mode. See the pass-through port redirect command set on page 4-8 to set the Pass-through mode.
Pin Function
TX
Transmit data
RX
Receive data
Gnd
Signal ground
*The default baud rate is 9600, but this can also be changed, using the MKP’s web pages, to 19200, 38400, or 115200 baud to match the switcher’s baud rate. See
Port (RS-232) Settings in chapter 5, HTML Operation, to change the baud rate.
Ethernet Link
The rear panel LAN connector on the MKP can be connected directly to a host computer (for set-up) or a matrix switcher (for switcher control) or to an Ethernet LAN or WAN (to which a host computer, other MKPs and a matrix switcher can also be connected).
Connection directly to a host computer requires a crossover cable.
Connection via an Ethernet LAN requires a patch (straight) cable.
See TP cable termination in chapter 2, Installation to create crossover and patch cables.
Default IP address
To access the MKP via the Ethernet port, you will need the Extron IP address. If the address has been changed to an address comprised of words and characters, the actual numeric IP address can be determined using the ping (ICMP) utility. If the address has not been changed, the factory-specified default is 192.168.254.253.
Host-to-MKP Instructions
The switcher accepts SIS (Simple Instruction Set) commands through the Host RS-232 port and Ethernet port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each switcher response to an SIS command ends with a carriage return and a line feed (CR/LF = ), which signals the end of the response character string. A string is one or more characters.
MKP-Initiated (Unsolicited) Messages
When a local event such as a front panel operation occurs, the switcher responds by sending a message to the host. The switcher-initiated messages are listed below (underlined).
(C) Copyright 2004, Extron Electronics MKP 2000, Vx.xx The switcher initiates the copyright message when it is first
powered on or when connection via Internet protocol (IP) is established. Vx.xx is the firmware version number.
Password:
The switcher initiates the password message immediately after the copyright message when the controlling system is connected using TCP/IP or Telnet and the switcher is password protected.
MKP 2000 Remote Control Panel • SIS Operation
MKP 2000 Remote Control Panel • SIS Operation
4-34-2
SIS Operation, cont’d
This message means that the switcher requires an administrator or user level password before it will perform the commands entered via this link. The switcher repeats the password message response for every entry other than a valid password until a valid password is entered.
Login Administrator Login User
The switcher initiates the login message when a correct administrator or user password has been entered. If the user and administrator passwords are the same, the switcher defaults to administrator privileges.
MKP Error Responses
When the switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, the switcher returns an error response to the host. The error response codes are:
E01 — Invalid input channel number (too large) E10 — Invalid command E12 — Invalid output number (too large) E13 — Invalid value (out of range) E14 — Illegal command for this configuration E24 — Privilege violation (Ethernet, Extron software only) E99 — Invalid or no response from target switcher
ASCII to HEX Conversion Table
Space
The MKP always redirects a subset of valid matrix switcher­specific SIS commands on its Ethernet port and, if configured in pass-through mode, on its Switcher RS-232 port.
It is not the purpose of this manual to define in detail the passed-through matrix switcher-specific SIS commands. Refer to the applicable matrix switcher’s manual.
Symbols are used throughout the tables to represent variables in the command/response fields. Command and response examples are shown throughout the MKP SIS commands table.
Using the Command/Response Table
The command/response table begins on page 4-8. Lower case letters are acceptable in the command field except where indicated for the gain and attenuation commands. The table below shows the hexadecimal equivalent of each ASCII character used in the command/response tables.
MKP 2000 Remote Control Panel • SIS Operation
MKP 2000 Remote Control Panel • SIS Operation
4-54-4
SIS Operation, cont’d
Symbol definitions for MKP SIS commands
= CR/LF (carriage return/line feed) (0x0D 0A)
= space
X1
= On/off status 0 = off/disable 1 = on/enable
X2
= RS-232 port number 1 = host 2 = switcher
X3
= n=–1= redirect serial port data from the specified port to allow for
a transparent pass through mode. The response is returned with leading zeroes. n = the maximum number of serial ports that the IP link supports. X5 is verified at this port.
X4
= Time (in 10 ms increments) to wait for receive data before
releasing the port to another source (min = 1 [10 ms], maximum = 32767 [32.767 seconds], default = 10 [100 ms]).
X5
= Numerical value (nnnn) to set L (length of message to receive) or
assign as a D (delimiter). L = number of byte count (min = 0, max = 32767, default = 0). D= decimal number for ASCII character (min = 0, maximum = 00255, default = 00000L).
The numeric value directly precedes the identifier; for example: X5 = “3L” to specify a 3-byte length or X5 = “10D” to specify an ASCII delimiter of 0A. The identifier, “L” or “D” must be uppercase.
X6
= Firmware version Bootstrap version (x.xx)
X7
= Verbose firmware version-description-upload date/time. See
page 4-8.
X8
= Voltage 1 (3.3 V), Voltage 2 (12.0 V),
Temperature (degrees Fahrenheit) (xxx.xx)
X9
= Verbose/response mode 0 = no password assigned
1 = verbose mode 2 = tagged responses for queries 3 = 1 and 2 (verbose and tagged)
The default X9 value is 0 for telnet and 0 for RS-232. If tagged responses are enabled, all read commands return the constant
string plus the data, the same as setting the value. For example, the MKP responds Ipn•
X10
= Security level 0 = clear/none
X12
Esc
to the
•CN command.
11 = user password assigned 12 = administrator password assigned
X11
= Name 12 characters maximum.
Upper and lower case alphanumeric characters and “ ” + _ : = / and spaces are valid.
The following characters are invalid in the name: + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X12
= Default name Factory default name
(combination of the model name + last 3 pairs of MAC address).
X13
= Time and date (set) MM/DD/YY-HH:MM:SS
where:
MM = month: 01 (Jan.) — 12 (Dec.) DD = day: 01 through 31 YY = year: 00 through 99 HH = hour: 00 through 24 MM = minutes: 00 through 59 SS = seconds: 00 through 59
X14
= Time and date (read) Day,•DD•Mmm•YYYY•HH:MM:SS
where:
Day = weekday: Mon through Sun DD = day: 01 through 31 Mmm = month: Jan through Dec YYYY = year: 2000 through 2099 HH = hour: 00 through 24 MM = minutes: 00 through 59 SS = seconds: 00 through 59
X15
= GMT offset –12.0 through +14.0. Hours and
minutes removed from GMT
X16
= Daylight Savings Time 0 = Daylight Savings Time off/ignore
1 = Daylight Savings Time on (northern hemisphere) 2 = Daylight Savings Time on (Europe) 3 = Daylight Savings Time on (Brazil)
X17
= IP address ###.###.###.###
X18
= Hardware (MAC) address ##-##-##-##-##-##
X19
= Connection priority 0 = Primary
1 = Secondary
X20
= Password 12 digits, alphanumeric
The following characters are invalid in passwords: {space} + ~ @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X21
= Web page priority 0 = Internal (default on power up)
1 = User
MKP 2000 Remote Control Panel • SIS Operation
MKP 2000 Remote Control Panel • SIS Operation
4-74-6
SIS Operation, cont’d
X3
Unlock front panel.
Read front panel lock: 1 = locked, 0 = unlocked.
Turn redirect mode on.
X5
,
X4
,
View redirect mode on/off status.
See Appendix A for part numbers.
Firmware version x.xx.
Provide a detailed status of the Ethernet protocol
firmware, the MKP controller firmware, and any
firmware upgrade. The firmware that is running is
marked by asterisk (*). A caret (^) indicates that the
firmware has a bad checksum or an invalid load.
?.?? indicates that firmware is not loaded.
Voltage and temperature readings.
reset, sets the MKP’s IP address to 192.168.254.254,
and sets the subnet mask to 255.255.0.0.
that sent the command.
Password level protection assigned.
Assign a name to the MKP.
Reset the MKP’s name to the factory default.
).
X12
may be
X11
Read assigned MKP name (
Set the time and date.
Read the time and date.
The divider between hours and minutes is a period.
•Ccd
Ccd00000,00000,00000L
X2
X2
X1
CD Cpn
X5
*
X4
*
X3
*
*0CD Cpn
X2
X2
1*2*50*10D*CD Cpn01•Ccd00002,00050,00000L
Esc
Esc
(host to MKP) (MKP to host)
Esc
Example:
Lock front panel 1x Exe1 Lock front panel.
Unlock front panel 0x Exe0
Command/response table for MKP SIS commands
Command ASCII Command Response Additional description
Front panel security lockout (executive mode)
4-8
MKP 2000 Remote Control Panel • SIS Operation
Read front panel lock x
Configure redirect mode
Pass-through (RS-232 port redirect)
Disable redirect
X5
,
X4
,
X3
CD
X2
Esc
View redirect
Information request I MKP•2000 Report model name.
View, information, part number, and firmware requests
X6
X7
Request for part number N 60-682-00
Query firmware version Q
Query verbose firmware version 0Q
X8
Response description: Ethernet protocol firmware version - controller firmware version - updated firmware version
Query status S
X12
X11
X1
X10
CV Vrb1 The MKP reports all status changes to the device
ZQQQ Zpq Performs all of the reset functions as the master
Esc
(host to MKP) (MKP to host)
Command/response table for MKP SIS commands (continued)
Command ASCII Command Response Additional description
Absolute reset
Resets
X9
CV
CK
Esc
Esc
Esc
Set verbose mode on
Verbose mode
Read connection’s security level
Read verbose mode
IP setup
X11
CN Ipn
•CN Ipn•
CN
Esc X11
Esc
Esc
Set MKP name
Set MKP name to factory default
Read MKP name
X15
X14
X14
X15
CT Ipt
CZ Ipz
X15
CT
CZ
Esc X13
Esc
Esc
Esc
Read time/date
Set GMT offset
Set time/date
Read GMT offset
MKP 2000 Remote Control Panel • SIS Operation
4-9
SIS Operation, cont’d
Set the switcher to display the local time as
Daylight Savings Time (+1 hour) in summer
months.
X16
X1
X16
variable, but not both. The response is as shown
X19
Set MKP to report changes from other sources.
Read the verbose mode.
or the
X17
X19
,
X18
,
X17
X17
X1
X17
X17
X18
X17
X17
X17
Sip
X19
,
X18
X20
,
X17
X20
X20
X21
X1
X20
X1
X21
X10
SI
X19
CX Ipx
X16
,
(host to MKP) (MKP to host)
Command/response table for MKP SIS commands (continued)
Command ASCII Command Response Additional description
Esc
Set Daylight Savings Time
IP setup (continued)
CX
Esc
Read Daylight Savings Time
CI Ipi
DH Idh
X1
DH
CI
Esc
Esc
Esc X17
Esc
Set DHCP on or off
Read DHCP status
Set MKP IP address
Read MKP IP address
CS Ips
CG Ipg
— or —
CH
CS
CG
Esc
Esc X17
Esc
Esc X17
Esc
Esc X17
The set target IP parameters command can be issued with either the
regardless of which variable is entered.
Read hardware (MAC) address
Set subnet mask
Read subnet mask
Set target (switcher) IP parameters
Set gateway IP address
Read gateway IP address
MKP 2000 Remote Control Panel • SIS Operation
CA Ipa
SI
•CA Ipa•
Esc
Esc X20
Esc
Set administrator password
Clear administrator password
Read target (switcher) IP parameters
CU Ipu
CA
Esc
(host to MKP) (MKP to host)
Command/response table for MKP SIS commands (continued)
Command ASCII Command Response Additional description
Esc X20
When you have connected multiple MKPs to control a switcher through a primary MKP control panel, do not set a user password on the
primary MKP.
Read administrator password
Set user password
IP setup (continued)
Cpag Iwp
CV Vrb
•CU Ipu•
CU
Esc
Esc
Read user password
Clear user password
X1
Cpag
Esc X21
Esc
Esc
Switch web page priority
Read web page priority
Set verbose mode
CV
CK
Esc
Esc
Read verbose mode
Read connection’s security level
MKP 2000 Remote Control Panel • SIS Operation
4-114-10
SIS Operation, cont’d
MKP 2000 Remote Control Panel
Chapter Five
5
4-14
HTML Operation
Download the Startup Page
System Status Page
System Settings Page
Port (RS-232) Settings Page
Passwords Page
Firmware Upgrade Page
File Management Page
Special Characters
MKP 2000 Remote Control Panel • SIS Operation
HTML Operation
The MKP can be configured through its Ethernet port, connected via a LAN or WAN, using a web browser such as Microsoft’s Internet Explorer. The browser’s display of the MKP’s configuration has the appearance of web pages. This chapter describes the factory-installed HTML pages, which are always available and cannot be erased or overwritten.
If your Ethernet connection to the matrix switcher is unstable, try turning off the proxy server in your Web browser. In Microsoft’s Internet Explore, click Tools > Internet Options > Connections > LAN Settings, uncheck the “Use a proxy server...” box, and then click Ok.
Download the Startup Page
Access the MKP using HTML pages as follows:
1. Start the Web browser program.
2. Click in the browser’s Address field.
3. Enter the MKP’s IP address in the browser’s Address field.
If the local system administrators have not changed the value, the factory-specified default, 192.168.254.253, is the correct value for this field.
4. If you want the browser to display a page other than the
default page (such as a custom page that you have created and uploaded), enter a slash (/) and the file name to open.
The browser’s Address field should display the address in the following format: xxx.xxx.xxx.xxx/ {optional_file_name.html}.
The following characters are invalid in file names: {space} + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
5. Press the keyboard Enter key. The MKP checks to see if it
is password protected. If the MKP is not password protected, proceed to step 7. If the MKP is password protected, the MKP downloads the
Enter Network Password page (figure 5-1).
Figure 5-1 — Enter Network Password page
A User Name entry is not required.
6. Click in the Password field and type in the appropriate
administrator or user password. Click the OK button.
7. The MKP checks several possibilities, in the following
order, and then responds accordingly: a. Does the address include a specific file name, such as
10.13.156.10/file_name.html? If so, the MKP downloads that HTML page.
b. Is there a file in the MKP’s memory that is named
“index.html”? If so, the MKP downloads “index.html” as the default startup page.
c. If neither of the above conditions is true, the MKP
downloads the factory-installed default startup page, “nortxe_index.html” (figure 5-2), also known as the System Status page.
MKP 2000 Remote Control Panel • HTML Operation
MKP 2000 Remote Control Panel • HTML Operation
5-35-2
HTML Operation, cont’d
System Status Page
The System Status page (figure 5-2) provides an overall view of the status of the MKP, including various IP addresses, the status of the Host and Switch RS-232 ports, and the voltage. The System Status page is the default page that the switcher downloads when you connect to the MKP. Access the System Status page from other MKP HTML web pages by clicking the Status tab.
System Settings Page
You can change most of the IP parameters on the System Settings page (figure 5-3). Click the Configuration tab or the System Settings link on the left of the Port Settings, Password, or Firmware Upgrade page to download the System Status page.
Port Settings
Passwords
Firmware
Upgrade
Figure 5-2 — System Status page
MKP 2000 Remote Control Panel • HTML Operation
Figure 5-3 — System Settings page
The page is divided into three sections: IP Settings, Switcher Control Settings, and Date/Time Settings. There are three types of controls on the System Settings page: simple fields with no drop boxes, fields with drop boxes, and radio buttons.
Most IP protocol variables, such as the Unit Name, IP Address, Gateway IP address, Subnet Mask, and Switcher IP Address are presented in simple fields.
Most non-IP switcher variables and time and date variables are presented in fields with drop boxes.
On/off and multiple choice selections are radio buttons. All changes made on the System Settings must be confirmed by
clicking the Submit button in the appropriate section. Clicking the Cancel button abandons the changes.
MKP 2000 Remote Control Panel • HTML Operation
5-55-4
HTML Operation, cont’d
IP Settings section
Unit Name field
The Unit Name field contains the locally-assigned name of the MKP. This name field can be changed to any valid name, up to 24 alphanumeric characters.
The following characters are invalid in the unit name: + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
DHCP radio buttons
The DHCP On radio button directs the MKP to ignore any entered IP addresses and to obtain its IP address from a Dynamic Host Configuration Protocol (DHCP) server (if the network is DHCP capable). The DHCP Off radio button turns DHCP off. Contact the local system administrator.
IP Address field
The IP Address field contains the IP address of the MKP. This value is encoded in the MKP’s flash memory.
Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields (octets) separated by dots (periods). Each octet can be numbered from 000 through 255. Leading zeroes, up to 3 digits total per field, are optional. Values of 256 and above are invalid.
The factory-installed default address is 192.168.254.253, but if this conflicts with other equipment at your installation, you can change the IP address to any valid value.
IP address changes can cause conflicts with other equipment. Only local system administrators should change IP addresses.
Gateway IP Address field
The Gateway IP Address field identifies the address of the gateway to the switcher’s to be used if the MKP and the server are not on the same subnet.
The gateway IP address has the same validity rules as the MKP’s IP address. The default is 000.000.000.000.
Subnet Mask field
The Subnet Mask field is used to determine whether the MKP is on the same subnet as the switcher ’s server when you are subnetting. The default is 255.255.000.000.
MAC Address field
The Media Access Control (MAC) Address is hardcoded in the MKP and cannot be changed.
Switcher Settings section
MKP Connection Priority settings
Click the appropriate radio button to select among:
The Ethernet (IP) port to issue commands to the connected switcher
The MKP as primary (its Switch RS-232 port connected to the switcher)
The MKP as secondary (the MKP controls the switcher through another MKP)
Host Control Port settings
If the RS-232 radio button is selected in the Switcher Control Method box, click the MKP 2000 or Control System Pass Through radio button to select that function for the Host RS-232 port.
MKP 2000 selected — Commands received on the Host RS-232 port are executed by the MKP.
Pass Through selected — Commands received on the Host RS-232 port are forwarded to the connected switcher via the Switch RS-232 port.
If the IP radio button is selected in the Switcher Control Method box, the Host Control Port Settings selections are grayed out and unavailable.
Switcher IP settings
If the connected matrix switcher is Ethernet enabled, its IP address and password (if assigned) can be entered in these fields. The address and password are required for the MKP and the matrix switcher to communicate via their RJ-45 LAN connections. The default IP address value is 000.000.000.000.
If the Secondary MKP Connection Priority is selected, this section and all of the selections within it are labeled “Primary MKP” rather than “Switcher”.
Switcher Size settings
The MKP cannot determine the matrix size of the switcher to which it is connected. You must use the Switcher Size drop boxes to specify the number of inputs and outputs.
When creating ties from the front panel, if an input or output outside the available range for this MKP or the connected matrix switcher is selected, the LED display shows N-A.
MKP 2000 Remote Control Panel • HTML Operation
MKP 2000 Remote Control Panel • HTML Operation
5-75-6
HTML Operation, cont’d
Authorized inputs and authorized outputs
You can use the Authorized Inputs and Authorized Outputs drop boxes to narrow the number of inputs and outputs that are controllable from the MKP.
When creating ties from the front panel, if an input or output outside the available range for this MKP or the connected matrix switcher is selected, the LED display shows N-A.
Front panel configuration lock
Click the appropriate radio button to select the Unlocked or Locked to disable or enable the MKP control panel.
Date/Time Settings fields
The Date/Time Settings fields provide a location for viewing and setting the time functions.
If setting the time, set the local time. The Zone variable allows you to then enter the offset from Greenwich Mean Time (GMT).
The Zone field identifies the standard time zone selected and displays the amount of time, in hours and minutes, that the local time varies from the GMT international time reference.
When daylight savings time is turned on, the switcher automatically updates its internal clock between Standard Time and Daylight Savings Time in the spring and fall on the date that the time change occurs in the United States of America, Brazil, or Europe (depending on the radio button selected). When Daylight Savings Time is turned off, the switcher does not adjust its time reference.
Port (RS-232) Settings Page
The Port Settings page (figure 5-4) allows you to configure the MKP’s two (Host and Switch) RS-232 ports. Access the Port Settings page by clicking the Configuration tab and then the Port Settings link on the left side of the System Settings page.
System (IP)
Settings
Passwords
Firmware
Upgrade
Figure 5-4 — Port Settings page
The Serial Port 1 radio button selects the Host RS-232 port and the Serial Port 2 radio button selects the Switch RS-232 port. All changes made on the Port Settings must be confirmed by clicking the Submit button. Clicking the Cancel button abandons the changes.
The Extron defaults are shown below, but many switcher models have configurable ports. Extron default RS-232 port settings are:
9600 baud no parity
8 data bits 1 stop bit
no flow control
MKP 2000 Remote Control Panel • HTML Operation
MKP 2000 Remote Control Panel • HTML Operation
5-95-8
HTML Operation, cont’d
Passwords Page
Access the Passwords page (figure 5-5) by clicking the Configuration tab and then the Passwords link on the left side of the System Settings page.
System (IP)
Settings
Port Settings
Firmware
Upgrade
Figure 5-5 — Passwords page
The fields on the Passwords page are for entering and verifying administrator and user passwords. Passwords are case sensitive and are limited to 12 uppercase and lowercase alphanumeric characters. Each password must be entered twice; once in the Password field and then again in the Re-enter Password field. Characters in these fields are masked (•••••). If you do not want to password protect an access level, leave the Password field and the Re-Enter Password field blank. All changes made on the Port Settings must be confirmed by clicking the Submit button. Clicking the Cancel button abandons the changes.
To clear an existing password (so that no password is required), enter a space in the Password and Re-enter Password fields and click the Submit button.
An administrator password must be created before a user password can be created.
When you have connected multiple MKPs to control a switcher through a primary MKP control panel, do not set a user password on the primary MKP.
Firmware Upgrade Page
The Firmware Upgrade page provides a way to replace the firmware that is coded on the MKP’s control board without taking the MKP out of service, opening the enclosure, and replacing the firmware chip. Access the Firmware Upgrade page (figure 5-6) by clicking the Configuration tab and then the Firmware Upgrade link on the left side of the System Settings page.
System (IP)
Settings
Port Settings
Passwords
Figure 5-6 — Firmware Upgrade page
Update the switcher firmware as follows:
The Firmware Upgrade page is only for replacing the firmware that controls all switcher operation. To insert your own HTML pages, see File Management Page, on page 5-13.
1. Visit the Extron web site, www.extron.com and select
either:
• The download tab and then select firmware files
• The MKP 2000 product page
2. Select the latest firmware file for the MKP and download
it. Note the folder to which you save the firmware file.
3. Connect the PC to the MKP via the switcher’s Ethernet
port.
4. Access the MKP using HTML pages.
5. Click the Configuration tab.
6. Click the Firmware Upgrade link.
MKP 2000 Remote Control Panel • HTML Operation
MKP 2000 Remote Control Panel • HTML Operation
5-115-10
HTML Operation, cont’d
7. Click the Browse button. An open file window appears
(figure 5-7).
Figure 5-7 — Firmware upgrade open file window
8. Navigate to the folder where you saved the firmware
upgrade file. Select the file.
Valid firmware files must have the file extension ‘.S19’. Any other file extension is not a firmware upgrade.
The original factory-installed firmware is permanently available on the MKP. If the attempted firmware upload fails for any reason, the MKP automatically reverts to the factory-installed firmware.
9. Click the Open button.
10. Click the Upload button. The firmware upload to the MKP
may take a few minutes. The MKP’s LED display shows UPL, then 777, and then the firmware version number. When the LED display shows ... , the firmware upload is complete.
File Management Page
To delete files such as HTML pages from the switcher or to upload your own files to the switcher, click the File Management tab. The switcher downloads the file management HTML page (figure 5-8).
Figure 5-8 — File Management page
The files listed in figure 5-8 are shown for example only and may not be present on your switcher.
To delete a file, click the individual Delete button to the right of the file that is no longer needed.
Upload your own files as follows:
The following characters are invalid in file names: {space} + ~ @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
1. Click the Browse button.
2. Browse through your system and select the desired file(s).
If you want one of the pages that you create and upload to be the default startup page, name that file “index.html”.
3. Click the Upload File button. The file(s) that you selected
appear in the list.
MKP 2000 Remote Control Panel • HTML Operation
MKP 2000 Remote Control Panel • HTML Operation
5-135-12
HTML Operation, cont’d
Special Characters
The HTML language reserves certain characters for specific functions. The MKP will not accept these characters as part of its name, passwords, or locally created file names. Valid file names:
Are a maximum of 24 uppercase or lowercase alphanumeric characters
Cannot include spaces or underscore characters
Cannot start with a number or a dash
Cannot end with a dash
MKP 2000 Remote Control Panel
Appendix A
A
5-14
Reference Data
Specifications Part Numbers
Mounting and Cabling Specifications
MKP 2000 Remote Control Panel • HTML Operation
Reference Data
Specifications
Control/remote — keypad
Extron remote key pad control .. (2) 3.5 mm, 3-pole captive screw
connectors
General
External power supply ............... 100 VAC to 240 VAC, 50/60 Hz, external,
autoswitchable; to 12 VDC, 1 A, regulated
Power input requirements ......... 12 VDC, 350 mA
Temperature/humidity .............. Storage: -40 to +158 °F (-40 to +70 °C) /
10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) /
10% to 90%, noncondensing
Rack mount................................... No, but furniture/wall mountable in a
wall box
Enclosure type.............................. Metal
Enclosure dimensions
Plate ................................... 4.5" H x 4.6" W x 0.1" D (2 gang)
(11.4 cm H x 11.7 cm W x 0.3 cm D)
Enclosure .......................... 2.7" H x 3.4" W x 2.0" D
(6.7 cm H x 8.6 cm W x 5.1 cm D)
Allow at least 1" (2.5 cm) D for connectors
and cable.
(Depth excludes connectors.)
Product weight............................. 0.4 lbs (0.2 kg)
Shipping weight........................... 2 lbs (1 kg)
Vibration ....................................... ISTA 1A in carton (International Safe
Transit Association)
Listings .......................................... UL, CUL
Compliances ................................. CE, FCC Class A, VCCI, AS/NZS, ICES
MTBF ............................................. 30,000 hours
Warranty ....................................... 3 years parts and labor
All nominal levels are at ±10%.
Specifications are subject to change without notice.
Part Numbers
MKP 2000 Remote Control Panel Part number
MKP 2000, black 60-682-02 MKP 2000, white 60-682-03 MKP 2000, RAL 9010 (off white) 60-682-05
Included parts
These items are included in each order for an MKP 2000:
Included parts Part number
MKP 2000 12 VDC, 1A external power supply 70-055-01 MKP 2000 user’s guide
Two-gang mounting bracket/mud ring (black, white, RAL 9010 [off white]) 70-086-11, 21, 51
Installation accessories
Accessories Part number
Two-gang “J” box 2.5” deep 980084
Cables
Cables Part number
Comm-Link Cable: Cut lengths:
50 feet (15.2 m) 26-461-01 100 feet (30 m) 26-461-02 200 feet (60 m) 26-461-03 400 feet (120 m) 26-461-04
Bulk spools:
500 feet (152 m) 22-119-02 1,000 feet (305 m) 22-119-03
MKP 2000 Remote Control Panel • Reference Data
MKP 2000 Remote Control Panel • Reference Data
A-3A-2
Reference Data, cont’d
Mounting and Cabling Specifications
Electrical box cutout
Any standard box that meets the local electrical codes can be used, but boxes from different manufacturers can have different size openings. Extron recommends testing the fit of the MKP inside the electrical box and then placing the box flush against the mounting surface and tracing the cutout area.
Panel mount cutout template
Figure A-1 is a drawing that shows the dimensions for cutting a hole to accommodate the keypad circuit board for mounting the keypad on a flat surface. This type of installation can include a desk or podium, or a control panel or dashboard, where the back is protected and does not require an electrical box.
Drawn to scale; may be used as a template.
2.63”
3.38”
I/O
VOLUME
Circuit Board Box (behind front panel)
(cut-out area should be slightly
larger)
MKP 2000 Remote Control Panel • Reference Data
MKP 2000
Full Size
Figure A-1 — Panel mount cutout template
MKP 2000 Remote Control Panel • Reference Data
A-5A-4
Reference Data, cont’d
Extron Comm-Link cable
Wire specifications for Extron Comm-Link cable (figure A-2) are as follows:
A (red) = 18 AWG B (violet or blue) = 22 AWG (grouped and shielded) C (white) = 22 AWG D (Drain) = 24 AWG E (black) = 18 AWG
Comm-Link cable was designed for use with MKP control panels
g
A-6
Figure A-2 — Comm-Link cable
MKP 2000 Remote Control Panel • Reference Data
Loading...