Specifications — MHRVGA CableSpecifications — MHRVGA Cable
Description
Part No.
Model
(length)
UL NEC/
C(UL) CEC
UL AWM
Temp.
No.
of
Cond.
Standard
Lengths
Ft. m
Shipping
Weights
Lbs. kg
Conductor
(stranding)
Diameter
Nom. DCR
Nominal
Core OD
Shielding
Materials
(% coverage)
Inch mm pF/ft pF/m
Nom. DCR
Nominal
OD
Inch mm
Nom.
Imp.
(ohms)
Nom.
Vel.
of
Prop.
Nominal
Capacitance
Composite Cable: (3) 26 AWG Miniature Coax • (2) 26 AWG Shielded Twisted Pairs • (7) 26 AWG Insulated Conductors
Overall Cable Shield: Aluminum Foil (100%) + Tinned Copper Braid
Nonplenum Cable • Natural Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
22-024-01 (500')
22-024-03 (1000')
MHRVGA
Min. bend radius: 4.0"
NEC CM
UL 1581
CSA FT-4
AWM 2990
VW-1
60 °C
3
coax
2
shielded
twisted
pairs
7
insulated
conduct-
ors
500
1000
152.4
304.8
549524.5
43.1
26 AWG
(7/34)
0.019"
0.48 mm,
Tinned Cu
41 ohms/
1k ft,
135 ohms
1 km
Same as
above
Same as
above
0.076 1.93
0.033 0.84
0.033 0.84
Alum. Foil
(100%)
Tinned Cu
Serve (95%)
12.2 ohms/
1k ft,
40.0 ohms/
1 km
Tinned Cu
Braid (85%)
Single:
0.105 2.67
red, green, blue
Single:
black & red
black & white
Single:
blue, green,
violet, grey,
yellow, orange,
brown
18.0
Sweep tested 5 MHz to 1 GHz.
66%
35 115
conductor-
conductor
62 203
conductorconductor,
connected to
shield
Nominal
Attenuation
dB/
100 ft
-0.5
-1.2
-1.7
-2.4
-3.8
-4.5
-5.4
-6.3
-7.3
-7.7
-9.1
-11.5
-16.4
-19.5
-43.6
dB/
100 m
-1.7
-3.9
-5.5
-7.8
-12.3
-14.8
-17.6
-20.6
-23.9
-25.4
-29.9
-37.3
-53.8
-64.0
-143.0
MHz
1
59.175 83%
5
10
20
50
71
100
135
180
200
270
400
750
1000
3000
Overall
cable
Alum. Foil and
Tinned Cu
Braid (85%)
Overall:
0.330 8.39
gray
Plenum Cable • Natural Foamed FEP Insulation • PVC Inner Jackets • Blue Fire-Resistant PVC Outer Jacket
22-131-02 (500')
22-131-03 (1000')
MHRVGAP
Min. bend radius: 6.0"
NEC CMP
UL 910
75 °C
3
coax
2
shielded
twisted
pairs
7
insulated
conduct-
ors
152.4
500
1000 304.8
58
99 44.9
26.3
26 AWG
(7/34)
0.019"
0.48 mm,
Tinned Cu
41 ohms/
1k ft,
135 ohms
1 km
Same as
above
Same as
above
0.074 1.88
0.033 0.84
0.033 0.84
Alum. Foil
(100%)
Tinned Cu
Serve (95%)
12.2 ohms/
1k ft,
40.0 ohms/
1 km
Tinned Cu
Braid (85%)
Single:
0.102 2.60
red, green, blue
Single:
black & red
black & white
Single:
blue, green,
violet, grey,
yellow, orange,
brown
Sweep tested 5 MHz to 1 GHz.
66%
16.7
54.875 81%
35 115
conductor-
conductor
62 203
conductorconductor,
connected to
shield
100
135
180
200
270
400
750
1000
3000
1
-0.5
-1.1
-1.6
-2.3
-3.6
-4.3
-5.1
-6.0
-7.0
-7.4
-8.8
-11.8
-17.6
-21.4
-51.2
-1.5
-3.7
-5.4
-7.5
-11.8
-14.1
-16.8
-19.7
-23.0
-24.3
-28.8
-38.7
-57.8
-70.1
-168.0
5
10
20
50
71
Overall
cable
Alum. Foil and
Tinned Cu
Braid (85%)
Overall:
0.330 8.38
blue
02 December, 2008