Extron electronic DVI DL 201 TX-RX, DVI DL 201 RX User Manual

Extron
ASS THRU
Setup Guide — DVI DL 201 Tx/Rx
The Extron® DVI DL 201 Tx and DVI DL 201 Rx are dual link DVI transmitter (Tx) or receiver (Rx) units. Using three CAT 5/5e/6/7 twisted pair cables, DVI-D signals can be extended up to 100 feet (30 m) at resolutions up to 2560x1600 @ 60 Hz. They can be purchased as a pair or as individual units.
W
N
C
N
Step 1
Turn off all equipment or disconnect it from power sources. Mount the transmitter and receiver as desired. Follow the instructions included with the appropriate mounting kit.
Step 2
Use the three port captive screw connections to transmit pass-through RS-232 and IR signals from a control device to a remote device. RS-232 signals are bidirectional and use three wires (see diagram A. at right). IR signals are unidirectional and use two wires (see diagram B. at right). In each case the control device is wired to the transmitter in exactly the same way as the remote device is wired to the the receiver.
Step 3
Determine how the source device will obtain the EDID information and perform one of the following procedures:
Option 1 — To capture the EDID of a desired display and store it in the EDID Minder for future use:
a. Connect the display to the local monitor output of the transmitter.
b. Power on the transmitter and the local monitor.
c. Configure the DDC switches as shown in the figure at right.
These instructions provide a quick setup guide for experienced installers. Installation
and service must be performed by authorized personnel only.
The DVI DL 201 Tx/Rx works with unshielded twisted pair (UTP) cable or shielded twisted
pair (STP) cable. STP cables are required to ensure FCC Class A and CE compliance.
supply specified by Extron for this unit. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage
DVI DL 201 Tx
Dual Link DVI Transmitte r
DDC ROUTE
REMOTE
POWER 12V
0.4A MAX
LOCAL
SPARE
3
2
1
DO NOT CONNECT OUTPUTS TO LAN
LOCAL OUTPUT OUTPUT
DVI-D INPUT
RS-232 PASS-THRU
to the supply and the transmitter or receiver.
One power supply is provided
when the transmitter and receiver are purchased together. A power supply is not provided when either unit is purchased separately.
RS-232
Control System
PC w/ Dual Lin k DVI Output
A.
DVI DL 201 Transmitter or Receiver
RS-232 Control or Display Device
Local Monitor
Extron DVI DL 201 R x
Dual Link DVI Receive r
2560 x 1600 Fla t Panel Display w ith Dual-Link DVI Input
CONTROL
PASS THRU
Tx Rx
Tx Rx
B.
DVI DL 201 Transmitter or Receiver
IR Control or IR emitter
CAT 5/5e/6/7 Cabl es up to 200 feet
CONTROL PASS THRU
Tx Rx
DVI DL 201 Rx
DVI-D OUTPUT
Dual Link DVI Cable
P
ON
OFF
RS-232
CONTROL
Tx Rx
S G
EDID MINDER
DEFAULT EDID
ON
1 2 3
REMOTE DDC
Setup Guide — DVI DL 201 Tx/Rx (cont’d)
EDID
d. Press and release the EDID “Store” button (see the figure at right). The
rear panel LED turns amber while the EDID information is read and stored from the local monitor. Afterwards, the LED turns green.
e. Power off and disconnect the display from the transmitter.
f. Connect the transmitter to the receiver.
g. Connect a source device to the transmitter.
h. Connect a display device to the receiver and, if required, a local monitor to the transmitter.
i. Power on the display device(s), the transmitter, and the receiver.
j. Power on the source device.
Option 2 — To use the default EDID (2560x1600 @ 60 Hz):
a. Configure the DDC switches as shown in the figure at right.
b. Connect a source device to the transmitter.
c. Connect a display device to the receiver and, if required, a local monitor to
the transmitter.
d. Connect the transmitter and receiver.
e. Power on the transmitter, receiver, and display devices.
f. Power on the source device.
Option 3 — To use DDC pass-through routed to the local monitor:
a. Configure the DDC switches as shown in the figure at right.
b. Connect a source device to the transmitter.
c. Connect a display device to the receiver and, if required, a local monitor to
the transmitter.
d. Connect the transmitter and receiver.
e. Power on the transmitter, receiver, and local monitor.
f. Power on the source device.
g. Power on the display device.
STORE
ON
OFF
ON
OFF
EDID MINDER
DEFAULT EDID
ON
1 2 3
EDID MINDER
DEFAULT EDID
ON
1 2 3
REMOTE DDC
REMOTE DDC
Option 4 — To use DDC pass-through routed to the remote display:
a. Configure the DDC switches as shown in the figure at right.
b. Connect a source device to the transmitter.
c. Connect a display device to the receiver and, if required, a local monitor to
the transmitter.
d. Connect the transmitter and receiver.
e. Power on the transmitter, receiver, and display devices.
f. Power on the source device.

Troubleshooting

For complete instructions, consult the User’s Manual, which is available at the Extron website.
If problems are encountered, verify that the cables are routed and connected properly.
If the problems persist, contact the Extron Service Department.
Extron USA - West
Headqua rters
+800.6 33.9876
Inside USA / Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
Extron USA - East
+800.6 33.9876
Inside USA / Canada Only
+1.919.863.1794 +1.919.863.1797 FA X
Extron Euro pe
+800.3 987.6673
Inside Europe Only
+31.33.4 53.4040 +31.33.4 53.4050 F AX
© 2010 Extron Electronics. All rights reserved.
Extron Asia
+800.7 339.8766
Inside Asia Only
+65.63 83.440 0 +65.63 83.466 4 FAX
Extron Japa n
+81.3.35 11.7655 +81.3.35 11.7656 FAX
Extron Chi na
+400. 883.1568
Inside China Only
+86.21. 3760.1568 +86.21. 3760.1566 FA X
Extron Mid dle East
+971.4.2 991800 +971.4.2 991880 FA X
ON
OFF
EDID MINDER
DEFAULT EDID
ON
1 2 3
68-1531-50
Rev. A
01 10
REMOTE DDC
Loading...