DVI DA2 and DVI DA4 Setup Guide
These instructions provide a quick setup guide for the Extron® DVI DA2 and DVI DA4. Installation and service must be performed by authorized personnel only. To install, cable, and power on the DVI DA2 and DVI DA4:
Step 1 — Mounting
Step 2 — DVI Input/Output Cable Connections
Connect these cables, but do not power on the equipment yet:
Connect a DVI cable from the Input connector to the video source device.
Connect a DVI cable from the Local Monitor connector to the desired local output device.
Connect DVI cables from the output connectors to the desired display devices.
DVI DA2
1 2
DVI-D INPUT DVI-D OUTPUT
LOCAL MONITOR
POWER 12V
Extron DVI DA2
DVI Distribution Amplier
0.4A MAX
Flat Pane l Displa y
PC
Local Mo nitor
Extron USA - West
Extron USA - East
Extron Euro pe
Extron Asia
Extron Japa n
Extron Chi na
Extron Mid dle East
DVI DA2 and DVI DA4 Setup Guide (Continued)
Step 3 — Power Cable Connections
Connect the 12 VDC power supply to the power receptacle of the unit.
CAUTION: This product is intended to be supplied by a Listed Power Unit marked “Class 2” or “LPS”,
rated 12 VDC, maximum 1.0 A. Always use a power supply supplied or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the Extron A/V processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.
The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 75, and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to building structure or similar structure.
POWER 12V
0.4A MAX
RidgesSmooth
A A
Power Supply
Output Cord
DC Power Cord Captive Screw Connector
Ground +12 VDC
AC Power Cord
SECTION A–A
External
Power Supply
(12 VDC, 1 A )
NOTES: The length of the exposed wires in the stripping process is critical. The ideal length is
3/16 inches (5 mm). If the exposed section is longer, the exposed wires may touch, causing a short circuit between them. If it is shorter, the wires can be easily pulled out even if tightly fastened by the captive screws.
Do not tin the wires. Tinned wire does not hold its shape and can become loose over time.
Step 4 — Applying Power
NOTE: Output 1 is used as DDC reference and Hotplug Detect and a local monitor must be
connected to it before the source device is powered on. Since Output 1 is used for reference, all displays connected to the other outputs must be capable of handling resolutions greater than or equal to that of Output 1.
Power on the local monitor.
Power on the display devices.
Power on the source input device.
Headqua rters
+800.6 33.9876
Inside USA / Canada Only
+1.714.491.1500 +1.714.491.1517 FAX
+800.6 33.9876
Inside USA / Canada Only
+1.919.863.1794 +1.919.863.1797 FA X
+800.3 987.6673
Inside Europe Only
+31.33.4 53.4040 +31.33.4 53.4050 F AX
© 2010 Extron Electronics. All rights reserved.
+800.7 339.8766
Inside Asia Only
+65.63 83.440 0 +65.63 83.466 4 FAX
+81.3.35 11.7655 +81.3.35 11.7656 FAX
+400. 883.1568
Inside China Only
+86.21. 3760.1568 +86.21. 3760.1566 FA X
www.extron.com
+971.4.2 991800 +971.4.2 991880 FA X
68-1376-50
Rev C
04 10
Loading...