Extron TLP Pro 1230WTG Setup Guide

TLP Pro 1230WTG • Setup Guide
Go to www.extron.com for the
complete user guide and installation
instructions before connecting the
product to the power source.

Overview

IMPORTANT:
The Extron® TLP Pro 1230WTG is a 12" ultra-wide tabletop touchpanel with a capacitive, edge-to-edge glass touchscreen and a resolution of 1920x720. It has a weighted base that allows it to stand on any suitable table or desktop. It is ideal for any AV applications requiring a large touchpanel with a fully customizable interface. This guide provides instructions for experienced installers to mount and install the touchpanel. For more complete details, see the TLPPro 1230WTG User Guide at
www.extron.com.

Setup Overview and Checklist

Get Ready

 Download and install the latest version of the following software:
z GUI Designer — For designing layouts for Extron TouchLink
z Global Configurator
z Global Scripter
Scripter provides an Extron-exclusive Python™ library (ControlScript®) and Global Scripter modules to get you started.
z Toolbelt — For device discovery, device information, rmware updates, and conguration of network settings, system
utilities, and user management for TouchLink Pro devices.
®
Plus and Professional — For setting up and conguring the control processor and touchpanel
®
— Provides an integrated development environment for Extron control systems programming. Global
NOTE: All four software programs are available from www.extron.com.
 Obtain the following network information from your network administrator:
DHCP status (on or off). If DHCP is off, you also require:
®
Pro touchpanels and third party touch interfaces
IP address Subnet mask Gateway
Username — This can be either admin or user. Passwords — The factory congured passwords for all accounts on this device have been set to the device serial number.
Passwords can be changed during conguration. Passwords are case sensitive.
NOTE: If the device is reset to default settings, the passwords are reset to the default password, which is extron (for
either admin or user).
 Make a note of the touchpanel MAC address.

Mount and Cable All Devices

ATTENTION:
Do not power on the touchpanels until you have read the Attention in the “Power Supply” section of the
TLPPro 1230WTG User Guide.
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde dans la section «sources d’alimentation» du
TLPPro 1230WTG User Guide.
 Mount the units. There are several mounting options for TouchLink Pro touchpanels (see Mounting on page 2).  Connect cables to the touchpanels (see Rear Panel and Base Features on page 3).  Connect the touchpanel to a power source. These models must be powered by PoE. A power injector must be purchased
separately.
 An Extron IP Link
®
control processor must be connected to the same Ethernet subnetwork as the touchpanel.

Set up the Touchpanels for Network Communication

 Connect the PC that you will use for setup, the control processor, and touchpanel to the same Ethernet subnetwork.  Use the Setup Menu (see page 4) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask,
gateway, and related settings for the touchpanel.
Configure the Touchpanels
 Create a graphical user interface with GUI Designer (see the GUI Designer Help File for step-by-step instructions).  Associate functions with the graphical user interface features using Global Congurator or Global Scripter.
1
TLP Pro 1230WTG • Setup Guide
D
D
E

Mounting

Go to www.extron.com to see a list of optional mounting kits that are available for this model. The kits must be purchased separately. Follow the installation instructions provided with the kit.

Desktop Mounting

These touchpanels come assembled with stands that allow them to be placed on any suitable at surface (for example a desk, table, or lectern).
Fixed Mounting
1. Mark the location for two mounting holes, 4.96inches (126 mm) apart (see figure 2,
2. Drill two pilot holes into the desktop.
3. Insert two #10 at-head wood screws (not provided) through the touchpanel and align them with the two pilot holes.
4. Secure the touchpanel to the tabletop.

SMA-1 Swivel Mount Adapter

To permanently mount the touchpanel and swivel it up to 180° in either direction, use the optional Extron SMA-1 swivel mount adapter.
1. Attach the conduit, insulation disk, and swivel disk and congure the set screws to allow for the degree of swivel that is required
(see the SMA-1 Swivel Mount Adapter Kit User Guide, available at
2. Place the mounting hole in the base over the conduit of the SMA-1.
3. Secure the unit with the backing plate and locking nut as described in the SMA-1 Swivel Mount Adapter Kit User Guide.
www.extron.com).

Front Panel Features

, on page 3).
B
Figure 1. TLP Pro 1230WTG Front Panel
Ambient light sensor — Monitors ambient light level and adjusts screen brightness.
A
Motion sensor — Detects motion between three to ve feet from the touchpanel, and at least 15° from the center axis.
B
z If the Sleep Timer has been set, and no motion has been detected for a user-dened period of time, the touchpanel
enters sleep mode.
z If Wake on Motion has been set, and motion is detected by the sensor while the screen is in sleep mode, the screen
display is restored and active.
For further information about setting the TLP Pro 1230WTG User Guide, which is available at
Capacitive touch screen — Provides simple control of AV systems. The TLP Pro 1230WTG has a 12 inch screen with a
C
1920x720 resolution.
Speakers — Provide stereo audio for video preview and audible feedback from button presses. They are located below the
D
screen, one on each side of the panel.
Status light — Can be programmed to provide system feedback. The LED light bar is located under the screen.
E
A B C
Sleep Timer and Wake on Motion, see the “Setup Menu” section in the
www.extron.com.
2

Rear Panel and Base Features

H
C
J
A
I
Product Category
C
DDDBBB
C
H
H
I
I
GGG
Figure 2. TLP Pro 1225TG Rear Panel and Base
Speakers (2) — For video preview and audible feedback for the user.
A
Mounting Holes — Used to secure the touchpanel to a desktop or other at surface (see Desktop Mounting on page 2).
B
Cable Guide — The LAN/PoE and HDMI cables are inserted through this hole at the back of the base (see “TLP Pro 1230WTG
C
Base Features” in the TLP Pro 1230WTG User Guide).
LAN/PoE Connector — These touchpanels must be powered by Power over Ethernet (PoE; see “Connecting Power” below).
D
ATTENTION:
Do not power on the touchpanels until you have read the Attention notice in the “Power Supply” section of the
TLP Pro 1230WTG User Guide.
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde dans la section «PowerSupply» du
TLP Pro 1230WTG User Guide.
J
J
BBBAAA EEE FFF
A
A
NOTE: The TLP Pro 1230WTG ships without a power injector. The power injector must be purchased separately.
USB connector — Compatible with USB 2.0. The port is concealed behind a plastic cover, which can be removed with a small,
E
at-bladed screw driver.
Rear status light — An LED light bar that can be programmed to provide system feedback.
F
HDMI Connector — A recessed connector for HDMI input.
G
MENU button — Activates the Setup Menu (see page 4).
H
RESET button — Pressing the RESET button allows the unit to be reset in any of three different modes and can also be used to
I
toggle between enabling and disabling the DHCP client (see
RESET LED — Provides feedback about the reset status when the user presses the RESET button (see Reset Modes: A Brief
J
Summary

Connecting Power

ATTENTION:
Do not power on the touchpanels until you have read the Attention notice in the “Power Supply” section of the
Ne branchez pas les écrans tactiles avant d’avoir lu la mise en garde dans la section «PowerSupply» du
The TLP Pro 1230WTG must be powered by Power over Ethernet (PoE). The power injector must be purchased separately. The PI 140 is shown in
).
TLP Pro 1230WTG User Guide.
TLP Pro 1230WTG User Guide.
figure 3 on page 4. Your power injector may look different.
Reset Modes: A Brief Summary on page 4)
3
TLP Pro 1230WTG • Setup Guide
XTP Device
Extr
1. Connect a straight-through Ethernet cable from the power injector
to a switch or router. This cable carries network information from
100-240V~50/60 Hz
1.1A MAX
INPUT OUTPUT
LAN
the switch or router to the power supply input.
2. Connect a second straight-through cable from the power injector
to the PoE/LAN connector of the touchpanel (see on page 3). This cable carries the network information and 48VDC from the power injector to the touchpanel.
3. Connect the IEC power cord to a convenient 100 VAC to 240 VAC,
figure 2,
D
,
on PI 140
To Network or
To a TLP Pro touchpanel
50-60 Hz power source.
Alternatively, use an Ethernet cable to connect the LAN/PoE+ port of
Figure 3. Connecting the Power Injector
the touchpanel to a PoE+ switch.

Reset Modes: A Brief Summary

The TLP Pro 1230WTG offers the following reset modes. For complete information, see the TLPPro 1230WTG User Guide.
Use factory firmware:
Reset All IP Settings:
Reset to Factory Defaults:
Use this mode to replace rmware in the event of rmware failure. Press and hold the RESET button (I) while applying power to the unit.
Use this mode to reset all network settings without affecting user-loaded les. Press and hold the RESET button for 6 seconds. After the RESET LED (J) blinks twice (at 3 and 6 seconds), release and momentarily press the
RESET button.
Use this mode to return the touchpanel to factory default settings, including passwords. Press and hold the RESET button for 9 seconds. After the RESET LED blinks three times (at 3, 6 and 9 seconds), release and momentarily press the RESET button.
NOTES:
The factory congured passwords for all accounts on this device have been set
to the device serial number. Passwords can be changed during conguration. Passwords are case sensitive.
If the device is reset to default settings, the passwords are reset to the default
password, which is extron (for either admin or user).
POWERED TLP
Enable or Disable the
DHCP Client:
Use this mode to toggle between DHCP enabled and DHCP disabled. Press the RESET button ve times, consecutively. After the fth press, do not press the button again within 3 seconds. If DHCP was enabled, it is now disabled and the RESET LED blinks three times. If DHCP was disabled, it is now enabled and the RESET LED blinks six times.
NOTES:
By default DHCP is off and the unit uses a static IP address.
When you disable the DHCP client, the unit reverts to using the previously-set static IP
address.

Setup Menu

Press the Menu button (H) to open the setup menu. Select any of the six available screens (Status, Network, Display,
Audio, Input and Advanced) by tapping the appropriate
button in the navigation bar at the top of the screen (for more information, see the TLPPro 1230WTG User Guide).
Status
Model: TLP Pro 1225MG
Part Number: 60-1787-02
Firmware Version:
Bootloader Version:
PoE Status: Active
Network
Info
1.02.0001-b001
1.03.0000
Display
IP Address: DHCP: Host Name:
Master Volume: Master Mute: Off
Controller IP: 192.168.254.250 Project Size: 1/196 MB
Audio
Network
192.168.254.251 Off TLP-AB-CD-EF
Audio
100
Advanced
Advanced
Input
Resolution: GUI Project: Sleep Timer:
Input
HDMI Port: No Signal
Display
1280x800 1280x800 5 Minutes
Exit
Figure 4. Setup Menu: Status Page for TLP Pro 1230WTG
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
For information about replacing and disposing of batteries, see the TLP Pro 1230WTG User Guide at www.extron.com.
© 2021 Extron — All rights reserved. www.extron.com
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
All trademarks mentioned are the property of their respective owners.
68-3147-50 Rev. A
4
01 21
Loading...