Extron IPA T RLY4 User Manual

IPA T RLY4
User’s Guide
Relay Accessory Box
68-739-03 Rev. C
03 09
Introduction
IPA T RLY4
1 2 3 4 C
INPUTS
COM 3
LAN
UID# 093012052
POWER
12V .5A MAX
COM 2
1
COM1
TX RX TX RX
I/O
2
3
4
COM2
Extron IPL T SF24
Ethernet Control Interface
Extron IPA T RLY4
Relay Accessory
NO C NC
NO C NC NO C NC
NO C NC
RELAY 1
RELAY 2
RELAY 3
RELAY 4
Lighting System
Front
Rear
Extron
12 V Power Supply
+12 VDC
(Common)
The Extron IPA T RLY4 Relay Accessory is an IPLink® Accessory product. The Relay Accessory consists of four output relays with normally open (when the relay is de-energized) (NO) and normally closed (NC) contacts.
The Relay Accessory converts a solid state (up to 12 VDC) signal, from a source such as the Flex I/O port of an Extron IPL T SF24 or the digital I/O port of an MLC 104 IP Plus, to a relay contact closure. The relay contacts can handle up to 24 VAC or 24 VDC as a tally signal, contact closure signal, or control signal to drive devices in your system, such as a lighting system (figure 1) or remote screens. The relay contacts are protected by an overvoltage circuit.
Figure 1 — Typical IPA T RLY 4 application
The compact IPA T RLY4 can be concealed out of the way anywhere in your system with the included Velcro® strip.
1 IPATRLY4•Introduction