Extreme Networks 4411OU Users Manual

Installing the ExtremeWireless Outdoor AP3965
Electrical Hazard: Only qualified personnel should perform
installation procedures.
Overview of the AP3965
The AP3965 enables you to extend your Wireless LAN beyond the boundaries of indoor locations. It is resistant to harsh outdoor conditions and extreme temperatures (Operating Temp. -40ºC~60ºC). Using the advanced wireless distribution mesh feature of Wireless LAN, the AP3965 can extend your Wireless LAN to outdoor locations without Ethernet cabling. Mounting brackets are provided for quick and easy mounting of the AP to walls and poles.
Note: In this Quick Reference, any reference to AP3965applies to both AP3965 an “i” model (with internal antennas) and an “e” model (with external antennas).
Figure 1 AP3965 Top View
Unpacking the AP3965
The AP3965 box includes a cardboard separation. 1 Unpack the AP3965 from its carton. 2 Verify the contents of the carton as listed in
Table 1 Contents of the AP3965
Quantity Item
1 AP3965 Quick Reference 1 WS-AP3965i/e model that you ordered. Under the cardboard separation: 1 H” shaped bracket that is used for mounting the AP. 1 Metal bracket for attaching the AP to a pole, pipe, or mast. 1 #10AWG ground wire w ith a ring terminal crimped on it (6 foot
The following hardware is included: 4 Additional hex nuts for the concrete anchors. 4 Concrete wall anchor assemblies that include the anchors, a
4 Split washer for the concrete anchors. 4 Cable clamps, all are ½" wide. Two clamps accommodate a 2.5"
8 Screw assemblies, size M4, that include the screws, flat
1 Ground Screw assembly, size M4, that include the screw, star
length)
flat washer, and a hex nut.
maximum diameter pole and two clamps accommodate a 6”-7” diameter pole.
washers, and split washers.
washer, and split washer.
Ta b le 1.
a Use 4 M4 screw assemblies to attach the AP to the “H”
bracket on the side that does not have the PEM stand­offs.
b Tighten the four screws to a torque of 12.0 in-lbs.
5 Secure the anchors to the wall, then secure the bracket
to the anchors.
6 If using #10 screws, tighten them to a torque of 25 in-lbs.
If using ¼” screws, tighten them to 45 in-lbs.
Figure 2 AP3965 Wall Mount “H” Bracket
5 Put the metal band around the pole and insert it into the
clamp. Turn the clamp screw clockwise, tightening the band around the pole.
Figure 4 AP with Mounting Bracket—Horizontal Position
Figure 5 AP3965 Pole Mount—Vertical Pole
1 Status 5 Radio 1 (5 GHz)
2 LAN 1 (Ethernet 1) 6 LAN Ports (POE):
3 LAN 2 (Ethernet 2) 7 Console Port and Reset Button 4 Radio 2 (2.4 GHz) .
War nin g: Always install and torque all LAN and Console
caps properly, regardless of installation site location.
LAN 1 PDE Port LAN 2 PSE Port output of DC48V, 0.26A
AP3965 models have the following specifications:
• Radios: 2 radios (2.4 GHz and 5 GHz)
•LEDs: 5 (see
Figure 1)
• Power: 802.3at (PoE+) compliant
• The AP3965 supports the 802.11ac and 802.11n wireless standards, with full backward compatibility with legacy
802.11a, and 802.11b/g. The AP3965 with external antenna connectors supports a variety of antennas. (External antennas must be ordered separately.)
• The AP3965 interoperates fully with Wireless LAN, including support for VoWLAN, branch office mode, guest services, RTLS, availability and mobility features.
• Mounting brackets for a wall or pole mount
TM
• Enabled for use with an ExtremeCloud
Note: All radio and LAN ports are labeled on the AP3965.
entitlement.
For detailed installation information about the AP3965, see the ExtremeWireless AP3965i/e Installation Guide.
Optional: You may also need antennas, terminators, or cables. Refer to
www.extremenetworks.com/support for
product numbers.
Note: Before mounting the AP3965, read the “RF Safety Distance” on page 2.
Mounting the AP3965
Use these instructions as guidelines for mounting and connecting the AP3965 easily and safely. The installation of the AP3965 should be performed by a professional installer to ensure proper operation and compliance with local safety guidelines.
Attach the AP3965 to a surface that can support it and withstand its environment. It can be mounted to a wall, girder, ceiling, or pole, and the surface material can be concrete, brick, wood, metal, or plastic.
Positioning the AP for Installation
Mount the AP so that the glands are on the side of the AP closest to the ground, and not above the plastic cover. You must provide a 3-inch drip loop on all cables.
Attach the Ground Wire
Use the M4 ground screw assembly, with the star washer, to attach the ground wire’s ring terminal to the back of the AP. The wire should be as close to the AP bottom as possible. Tighten the screw to a torque of 12.0 in-lbs.
Mounting the AP3965 to a Wall
1 Using the mounting bracket as a guide, mark the location
for the mounting screws. The wall bracket provides 8 attachment holes. Use 4 (1 in each corner), Place the bracket and mark the 4 hole centers.
2 Drill four holes into the wall as follows:
– for installing the AP on a masonry wall, use a 5/16” diameter
bit.
– for other materials, use the appropriate drill for the screws
being used.
3 For masonry installations, drill at least 1/8” [3MM] past
the depth of the screw, or bolt, being used, and place four anchor assemblies into the holes.
4 Attach the AP to the “H” Bracket:
Mounting the AP3965 to a Pole
1 Determine the diameter of the pole.
Pole Diameter Cable Clamp Size
<= 2.5” [63.5mm], Use small cable clamp. 6” - 7” (178mm) Use large cable clamp
For other pole diameters, provide your own stainless steel cable clamp. The band must be ½” [12.7mm] wide.
2 Attach the AP to the “H” bracket on the side that does
not have the PEM stand-offs. Tighten the four screws to a torque of 12.0 in-lbs.
3 Using four M4 screw assemblies, attach the pole bracket
onto the “H” bracket. Tighten the screws to 12.0 in-lbs.
Figure 3 Attaching Pole Mount to “H” Bracket
4 Attach the cable clamp to the pole bracket. Open the
cable clamp by turning a flat bladed screwdriver counterclockwise. Then, insert the non-clamp end into the pole bracket through the holes.
Note: It is easier to install both clamps before attaching to the pole.
Installing External Antennas
1 Professionally install the external antennas intended for
area coverage. For information about antenna selection and installation, refer to the External Antenna Site Preparation and Installation Guide.
2 Attach the external antenna cables to the Standard
Polarity Type-N connectors on the AP3965.
Connecting & Powering the AP3965
You can power up the AP3965 using Power over Ethernet based on 802.3at (PoE+) compliant switch or PoE+ injector.
• The PoE injector must be 802.3at compliant. The PoE injector is not provided with the AP.
Note: When the AP3965 is powered by the Power Injector, the DATA port of the Injector should be connected to a non PoE switch or, if the switch is PoE capable, PoE must be DISABLED on the DATA port.
• A waterproof RJ45 connector is provided to connect the PoE injector to the AP3965. You must connect the RJ45 connector to the RJ45 cable. For instructions, refer to the ExtremeWireless Outdoor AP3965 Installation Guide.
Notice
Copyright © 2016 Extreme Networks, Inc. All Rights Reserved.
Legal Notices
Extreme Networks, Inc. reserves the right to make changes in specifications and other information contained in this document and its website without prior notice. The reader should in all cases consult representatives of Extreme Networks to determine whether any such changes have been made.
The hardware, firmware, software or any specifications described or referred to in this document are subject to change without notice.
Trademarks
Extreme Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks, Inc. in the United States and/or other countries.
All other names (including any product names) mentioned in this document are the property of their respective owners and may be trademarks or registered trademarks of their respective companies/owners.
For additional information on Extreme Networks trademarks, please see:
www.extremenetworks.com/company/legal/trademarks/
Documentation & Support
For product support, including documentation, visit:
www.extremenetworks.com/support/
Extreme Networks, Inc. 145 Rio Robles San Jose, CA 19534 Tel: +1 408-579-2800 Toll-free: +1 888-257-3000
Regulatory and Compliance Information
Federal Communications Commission (FCC) Notice:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Industry Canada Notice:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
This radio transmitter (IC: 4141B-4411OAC) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (IC: 4141B-4411AC) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour
l'exploitation de l'émetteur.:
Antennas for the AP 3965e Antenna Gain
Part No.
(Short Description)
30711 (WS-AO-DQ05120N) 2.4G/5G Sector 5.5 5.5
30712 (WS-AO-5Q04060N) 5G Sector N/A 4
30713 (WS-AO-2Q05060N) 2.4G Sector 5 N/A
30714 (WS-AO-DE07025N) 2.4G/5G Sector 7.5 6.5
30715 (WS-AO-DE13025N) 2.4G/5G Sector 13 12
30716 (WS-AO-5Q05025N) 5G Sector N/A 4.5
30717 (WS-AO-5Q11025N) 5G Sector N/A 11.5
30718 (WS-AO-DE10055N) 2.4G/5G Sector 10.5 7.5
30720 (WS-AO-DE07100N) 2.4G/5G Panel 7 6
30724 (WS-AO-DQ04360N) 2.4/5G Omni 5.5 6
WS-AO-5D23009N (WS-AO-5D23009N)
Frequency
Band
5G Sector N/A 23
Antenna
Typ e
2.4G Gain5GGain
Note: All antennas use Standard Polarity Type-N connectors. The antennas used for this transmitter must be installed to provide a
separation distance of at least 39 cm (150cm for WS-AO-5D23009N) from all persons and must not be co-located or operating in conjunction with another antenna or transmitter.
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 39 cm (150cm pour WS-AO­5D23009N) de distance entre la source de rayonnement et votre corps.
Dynamic Frequency Selection (DFS) for devices operating in the bands 5250- 5350 MHz, 5470-5600 MHz and 5650-5725 MHz
Sélection dynamique de fréquences (DFS) pour les dispositifs fonctionnant dans les bandes 5250-5350 MHz, 5470-5600 MHz et 5650-5725 MHz
This device may not be operated in the band 5150-5250 MHz outdoors. This band is restricted to indoor use only to reduce potential harmful interference to co-channel mobile satellite systems.
Ce dispositif ne peut pas être utilisé dans la bande 5150-5250 MHz à l'extérieur. Cette bande est limitée à une utilisation en intérieur afin de réduire les interférences nuisibles potentiel de co- canal avec les systèmes mobiles par satellite.
The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall be such that the equipment still complies with the e.i.r.p. limit.
le gain maximal d'antenne permis pour les dispositifs utilisant les bandes 5250-5350 MHz et
5470-5725 MHz doit se conformer à la limite de p.i.r.e. The maximum antenna gain permitted for devices in the band 5725-5850
MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate.
le gain maximal d'antenne permis (pour les dispositifs utilisant la bande 5725-5850 MHz)
doit se conformer à la limite de p.i.r.e. spécifiée pour l'exploitation point à point et non point à point, selon le cas.
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible.
Pour les produits disponibles aux États-Unis / Canada du marché, seul le canal 1 à 11 peuvent être exploités. Sélection d'autres canaux n'est pas possible.
High-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.
Les radars à haute puissance sont désignés comme utilisateurs principaux (c. utilisateurs prioritaires ) des bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient provoquer des interférences et / ou endommager les appareils LE- LAN.
Refer to the ExtremeWireless Outdoor AP3965 Installation Guide, Appendix B, “Regulatory Information,” for complete regulatory information.
RF Safety Distance
AP3965e, FCC ID: QXO-4411OAC
The antennas used for this transmitter must be installed to provide a separation distance of at least 39 cm (150cm for WS-AO-5D23009N) from all persons and must not be co-located or operating in conjunction with another antenna or transmitter.
AP3965i, FCC ID: QXO-4411OU
The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co­located or operating in conjunction with another antenna or transmitter.
Safety Guidelines
This section contains notices that you must adhere to ensure your personal safety and to prevent any damage to the equipment.
Grounding Warning:
War nin g: To operate the ExtremeWireless Outdoor AP3965 safely, the chassis ground connector must have a suitable cable connected. Do not use the ExtremeWireless Outdoor AP3965 without a ground cable connected.
Qualified Personnel:
Electrical Hazard: Only qualified personnel should perform installation procedures. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. A qualified person understands the requirements and risks involved with installing outdoor electrical equipment in accordance with national codes.
Lightning Protection Warning:
War nin g: Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system.When implementing your lightning protection concept, make sure you adhere to the VDE 0182 or IEC 62305 standard.
The AP3965 has a built-in lightning protector; no external lightning protector is required. You must, however, note that the lightning protector is not an adequate protection against a lightning strike. The lightening protector only works within the framework of a comprehensive lightning protection concept. If you have questions, ask a qualified specialist company.
European Waste Electrical and Electronic
Equipment (WEEE) Notice
In accordance with Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE):
1 The symbol above indicates that separate collection of electrical and electronic
equipment is required.
2 When this product has reached the end of its serviceable life, it cannot be disposed of
as unsorted municipal waste. It must be collected and treated separately.
3 It has been determined by the European Parliament that there are potential negative
effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment.
4 It is the users’ responsibility to utilize the available collection system to ensure WEEE
is properly treated. For information about the available collection system, please contact Extreme Customer Support at 353 61 705500 (Ireland).
NCC Statement
This product complies with the requirements of Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Declaration of Conformity in Languages of the European
Hereby, Extreme Networks, Inc. declares that the radio equipment type Wireless LAN Access Point is in compliance with Directive 1999/5/EC. The full text of the EU declaration of conformity is available at the following Internet address:
http://www.extremenetworks.com/
Note: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Hazardous Substances
Community
ExtremeWireless Access Points
Quick Reference
P/N 31016 WS-AP3965i-FCC P/N 31017 WS-AP3965i-ROW P/N 31018 WS-AP3965e-FCC P/N 31019 WS-AP3965e-ROW
P/N 9034916-02 Rev00
TM