Extreme Networks 10018 User Manual

Pluggable Hardware Installation Guide
100287-00 Rev. 15
Copyright © 2012–2014 Extreme Networks
AccessAdapt, Alpine, Altitude, BlackDiamond, Direct Attach, EPICenter, ExtremeWorks Essentials, Ethernet Everywhere, Extreme Enabled, Extreme Ethernet Everywhere, Extreme Networks, Extreme Standby Router Protocol, Extreme Turbodrive, Extreme Velocity, ExtremeWare, ExtremeWorks, ExtremeXOS, Go Purple Extreme Solution, ExtremeXOS ScreenPlay, ReachNXT, Ridgeline, Sentriant, ServiceWatch, Summit, SummitStack, Triumph, Unified Access Architecture, Unified Access RF Manager, UniStack, XNV, the Extreme Networks logo, the Alpine logo, the BlackDiamond logo, the Extreme Turbodrive logo, the Summit logos, and the Powered by ExtremeXOS logo are trademarks or registered trademarks of Extreme Networks, Inc. or its subsidiaries in the United States and/or other countries.
sFlow is the property of InMon Corporation. iBooks is property of Apple, Inc. Specifications are subject to change without notice. All other registered trademarks, trademarks, and service marks are property of their respective
owners. For additional information on Extreme Networks trademarks, please see: http://
www.extremenetworks.com/company/legal/trademarks/.

Table of Contents

Preface.........................................................................................................................................5
Conventions.............................................................................................................................................................................5
Related Publications............................................................................................................................................................6
Providing Feedback to Us................................................................................................................................................ 7
Chapter 1: Licensing Requirements.........................................................................................8
Optical Interfaces Licensing Requirements.............................................................................................................8
Licensing of Third-Party Optical Modules................................................................................................................9
Chapter 2: Extreme Networks SFP and SFP+ Modules.......................................................12
Overview of SFP and SFP+ Modules......................................................................................................................... 12
Types of Optical SFP and SFP+ Interfaces.............................................................................................................12
Prepare to Install or Replace an SFP Module....................................................................................................... 22
Install an SFP Module....................................................................................................................................................... 23
Connecting Fiber Cables................................................................................................................................................ 25
Remove an SFP Module.................................................................................................................................................. 25
Chapter 3: QSFP+ Modules.....................................................................................................26
QSFP+ Modules...................................................................................................................................................................26
SR4 QSFP+ Module...........................................................................................................................................................26
LR4 QSFP+ Module........................................................................................................................................................... 27
Install a QSFP+ Module....................................................................................................................................................27
Remove a QSFP+ Module.............................................................................................................................................. 29
Chapter 4: Direct-Attach Cables...........................................................................................30
Types of Direct-Attach Cables....................................................................................................................................30
SFP+ Direct-Attach Passive Cable............................................................................................................................30
QSFP+ Direct-Attach Cables........................................................................................................................................34
Chapter 5: Extreme Networks XFP Modules........................................................................37
Overview of XFP Modules..............................................................................................................................................37
Install an XFP Module.......................................................................................................................................................38
Remove an XFP Module...................................................................................................................................................41
Chapter 6: Extreme Networks XENPAK Transceivers........................................................42
Overview of XENPAK Modules................................................................................................................................... 42
Installing and Removing a XENPAK Module........................................................................................................ 46
Chapter 7: Extreme Networks CFP2 modules.....................................................................49
CFP2 Overview................................................................................................................................................................... 49
CFP2 Modules details.......................................................................................................................................................49
Installing a CFP2 Module..................................................................................................................................................51
Removing a CFP2 Module..............................................................................................................................................52
Appendix A: Safety Information............................................................................................53
Fiber Optic Ports and Optical Safety.......................................................................................................................53
GBIC, SFP (Mini-GBIC), SFP+, QSFP+, XENPAK, and XFP Regulatory Compliance.........................54
Sicherheitshinweise...........................................................................................................................................................54
LWL-Ports und optische Sicherheit..........................................................................................................................54
Konformität von GBIC, SFP (Mini-GBIC), QSFP+, XENPAK undXFP........................................................55
Pluggable Hardware Installation Guide 3
Table of Contents
Appendix B: Technical Specifications.................................................................................. 56
SFP Specifications............................................................................................................................................................. 56
SFP+ Specifications...........................................................................................................................................................62
QSFP+ Specifications.......................................................................................................................................................65
XFP Specifications.............................................................................................................................................................66
XENPAK Specifications...................................................................................................................................................70
CFP2 Specifications.......................................................................................................................................................... 74
Pluggable Hardware Installation Guide 4

Preface

Conventions

This section discusses the conventions used in this guide.

Text Conventions

The following tables list text conventions that are used throughout this guide.
Table 1: Notice Icons
Icon Notice Type Alerts you to...
Note Important features or instructions.
Caution Risk of personal injury, system damage, or loss of data.
Warning Risk of severe personal injury.
New This command or section is new for this release.
Table 2: Text Conventions
Convention Description
Screen displays
The words enter and type
[Key] names Key names are written with brackets, such as [Return] or [Esc]. If you must press two
Words in italicized type Italics emphasize a point or denote new terms at the place where they are defined in
This typeface indicates command syntax, or represents information as it appears on the screen.
When you see the word “enter” in this guide, you must type something, and then press the Return or Enter key. Do not press the Return or Enter key when an instruction simply says “type.”
or more keys simultaneously, the key names are linked with a plus sign (+). Example: Press [Ctrl]+[Alt]+[Del]
the text. Italics are also used when referring to publication titles.
Pluggable Hardware Installation Guide 5

Platform-Dependent Conventions

Unless otherwise noted, all information applies to all platforms supported by ExtremeXOS software, which are the following:
BlackDiamond® X8 series switch
BlackDiamond 8800 series switches
Cell Site Routers (E4G-200 and E4G-400)
Summit® family switches
SummitStack
When a feature or feature implementation applies to specific platforms, the specific platform is noted in the heading for the section describing that implementation in the ExtremeXOS command documentation. In many cases, although the command is available on all platforms, each platform uses specific keywords. These keywords specific to each platform are shown in the Syntax Description and discussed in the Usage Guidelines.

Terminology

Preface
When features, functionality, or operation is specific to a switch family, the family name is used. Explanations about features and operations that are the same across all product families simply refer to the product as the “switch.”

Related Publications

Documentation for Extreme Networks products is available at: www.extremenetworks.com. The following is a list of related publications currently available:
ExtremeXOS User Guide
ExtremeXOS Hardware and Software Compatibility Matrix
ExtremeXOS Legacy CLI Quick Reference Guide
ExtremeXOS ScreenPlay User Guide
Using AVB with Extreme Switches
BlackDiamond 8800 Series Switches Hardware Installation Guide
BlackDiamond X8 Switch Hardware Installation Guide
Extreme Networks Pluggable Interface Installation Guide
Summit Family Switches Hardware Installation Guide
Ridgeline Installation and Upgrade Guide
Ridgeline Reference Guide
SDN OpenFlow Implementation Guide
SDN OpenStack Install Guide
Some ExtremeXOS software files have been licensed under certain open source licenses. Information is available at: www.extremenetworks.com/services/osl-exos.aspx
Pluggable Hardware Installation Guide 6

Providing Feedback to Us

We are always striving to improve our documentation and help you work better, so we want to hear from you! We welcome all feedback but especially want to know about:
Content errors or confusing or conflicting information.
Ideas for improvements to our documentation so you can find the information you need faster.
Broken links or usability issues.
If you would like to provide feedback to the Extreme Networks Information Development team about this document, please contact us using our short online feedback form. You can also email us directly at
internalinfodev@extremenetworks.com.
Preface
Pluggable Hardware Installation Guide 7

1 Licensing Requirements

Optical Interfaces Licensing Requirements Licensing of Third-Party Optical Modules

Optical Interfaces Licensing Requirements

The following notes describe the licensing requirements for 40G and 100G optical interfaces used in Extreme Networks hardware.
Caution Beginning with EXOS 15.4, customers adding new unapproved third-party 40G or 100G optical interface modules to their Extreme Network switches will receive an informational message via SNMP/ Syslog. This message will indicate that they have an unapproved third­party 40G or 100G optic and that in EXOS 15.5 a third party 40G/100G feature license will be required for full functionality of the new hardware. Customers can purchase a feature license to remove this warning message.
Caution Beginning with EXOS 15.5, customers will need to purchase a feature license to achieve full functionality of new unapproved third-party 40G or 100G optical interfaces. If customers do not purchase the feature license for these new modules, they will receive an informational message via SNMP/ Syslog. This message will indicate that they have an unapproved third­party 40G or 100G optic and that a feature license is required for full functionality of the new hardware. Customers will have 90 days to obtain the feature pack before the port's egress bandwidth is rate-limited to 25% of line rate.
Warning Extreme Networks authorized and certified optical modules are tested to work in all supported Extreme Networks hardware and switching equipment. Extreme Networks does not provide any warranty or compliance statement pertaining to any third-party non­approved hardware. Use of non-approved optics modules and corresponding interface modules is solely at your own risk and without any liability, warrant, or service obligation by Extreme Networks. Extreme recommends use and integration of only manufacturer certified hardware as expressly referenced within the applicable Extreme Networks product documentation. In addition, any non-approved third-party optic modules in use by you shall be compliant with all regulatory standards as applicable to the location of operation that may include but not limited to NRTL, FCC CFR 21 1040.10, CDRH Letter of Approval, CE marked, EN60825-1 and or GR-468.
Pluggable Hardware Installation Guide 8
Licensing Requirements

Licensing of Third-Party Optical Modules

Extreme Networks optical modules are tested to work in all supported Extreme Networks switches. We recommend that all customers use Extreme Networks optical modules in their Extreme Networks switches. Extreme Networks assumes no liability for third-party optical modules. Although Extreme Networks does not block third-party optical modules, we cannot ensure that all third-party optical modules operate properly in all Extreme Networks switches. The customer assumes all risks associated with using third-party optical modules in Extreme Networks switches.
Extreme Networks’ recommended policy is for its customers to purchase Extreme authorized and qualified optical devices as further described on Extreme’s then-current price lists. Historically, Extreme Networks customers were not technically restricted from integrated use of non-approved 3rd party optical devices to attach to high-speed ports. In keeping with standard industry practices, to maximize overall product quality and reduce servicing challenges, Extreme Networks will restrict the integration of non-qualified 3rd party optical devices within 40G and 100G product environments, unless you purchase the EXOS 3rd Party 40G/100G Optics feature license to allow such integration.
Note Pursuit of such integration remains outside of Extreme’s standard committed terms of
product warranty and support Direct customer support for such usage of high-speed unapproved 3rd party optical devices will continue to be limited, and considered out of scope.
The use of 1G and 10G optic devices by customers is not affected by this new Feature Pack use requirement.
Extreme Networks’ policy regarding the use of 3rd Party Optics can be viewed in our Pluggable Interface Modules Installation Guide, and related policies, located here: www.extremenetworks.com
This EXOS 15.5 release creates a new requirement for customers to purchase a feature license pack named “3rd Party Optics Feature License”. Like other feature-pack licenses, once you apply the license to a specific switch, the feature is enabled for the life of the switch. Without such a license, switches with 40G and 100G hardware ports that are inserted with unapproved 3rd Party optics modules will have 90 days before the egress traffic on that particular port is automatically limited to 25% of line rate.
Note The restriction is flagged by show port conf command output, and warningmessages are
issued when 3rd party 40G and 100G optical devices are inserted. The restriction is lifted when the “3rd Party Optics Feature License” license is installed.
Note Purchase of an “EXOS 3rd Party Optics Feature License” seeks to enable the unrestricted use
of unapproved 3rd party 40G & 100G optical transceiver for the life of the switch.
The purchaser of the “EXOS 3rd Party Optics Feature License” is solely responsible for the use of optic devices that are compliant with applicable standards and safety requirements. The use of non­compliant optic modules may result in damage to the equipment or personal injury. Extreme Networks does not provide any warranty or compliance statement pertaining to any third party non-approved
Pluggable Hardware Installation Guide 9
Licensing Requirements
hardware, including unapproved 3rd party optic modules. See applicable hardware manual for more detail of these requirements.
The EXOS 3rd Party 40G/100G Optics Licensing feature has the following caveats and restrictions:
The system reads and interprets the license information, and maintains a flag that indicates the
presence of the optics license. When you insert the optical transceiver, if the 3rd Party optic license is installed no further action is
necessary. If the device is an Extreme optical transceiver no further action is necessary.
If the optical transceiver is restricted, the system sets a flag, R.
If the optical transceiver is restricted, the system installs an egress rate limiter of 25% associated
with the port. If the device is restricted, the system generates a warning EMS message that indicates the
restriction. If you remove the optical transceiver, the following conditions occur:
The system unsets the flag that indicates a restriction in the port.
The system removes the egress rate limiter associated with the port, or restores a configured
one.
When you enable a port, the following conditions occur:
The system determines if the port is restricted.
The system generates a warning message to a console with restricted ports.
The system generates a warning EMS message that indicates a restriction.
When you enable a license, the system reads and interprets the new license information. If it
determines the optics license is now active, and it was not active before, the following conditions occur:
Sets the “optics license” present flag.
Searches the port list for restricted ports.
Removes the egress rate limiter associated with the port, or restores a configured one.
Note This feature requires you to coordinate with other Extreme corporate processes, including how to generate a license generation and how to purchase a license
All platforms that support 40G and 100g optical devices are supported with this feature. The current list of devices subject to restriction includes:
QSFP+ SR4
QSFP+ LR4
QSFP+ Passive Copper 0.5m Cable
QSFP+ Passive Copper 1m Cable
QSFP+ Passive Copper 2m Cable
QSFP+ Passive Copper 3m Cable
QSFP+ Passive Copper 5m Cable
QSFP+ Active Optical 10m Cable
QSFP+ Active Optical 20m Cable
QSFP+ Active Optical 100m Cable
QSFP+ to SFP+ Fan Out Passive Copper 3m Cable
Pluggable Hardware Installation Guide 10
QSFP+ to SFP+ Fan Out Passive Copper 5m Cable
QSFP+ to SFP+ Fan Out Passive Copper 1m Cable - QSFP+ end
QSFP+ to SFP+ Fan Out Passive Copper 2m Cable - QSFP+ end
CFP2 LR4
CFP2 SR10
Licensing Requirements
Pluggable Hardware Installation Guide 11
2 Extreme Networks SFP and SFP+
Modules
Overview of SFP and SFP+ Modules Types of Optical SFP and SFP+ Interfaces Prepare to Install or Replace an SFP Module Install an SFP Module Connecting Fiber Cables Remove an SFP Module

Overview of SFP and SFP+ Modules

Extreme Networks switches and routers support small form factor pluggable (SFP) interface modules, also known as mini-GBICs. Extreme Networks devices support both optical and copper SFP and SFP+ modules. The type of switch, router, or other component determines the compatible type of SFP or SFP +module.
Use only Extreme Networks-certified SFP and SFP+ modules, available from Extreme Networks, in the SFP port on the switch or router.

Types of Optical SFP and SFP+ Interfaces

Extreme Networks switches support many interfaces. This includes the following types of optical SFP and SFP+ interfaces:
SX and Industrial Grade SX SFP modules (see SX and Industrial Grade SX SFP Modules)
LX and Industrial Grade LX SFP modules (see LX and Industrial Grade LX SFP Modules)
ZX SFP module (see ZX SFP Module)
1000BASE-BX bidirectional SFP modules (see 1000BASE-BX Bi-Directional SFP Modules)
1000BASE-BX-D
1000BASE-BX-U
100FX SFP module for Gigabit Ethernet ports (see 1100FX SFP Module for Gigabit Ethernet Ports)
Dual-speed 100FX/1000LX SFP module (see Dual-speed 100FX/1000LX SFP Module)
LX100 SFP module (see LX100 SFP Module)
100BASE-LX10 SFP module (see 100BASE-LX10 SFP Module)
100BASE-BX bidirectional SFP modules (see 100BASE-BX Bi-Directional SFP Modules)
100BASE-BX-D
100BASE-BX-U
Pluggable Hardware Installation Guide 12
Extreme Networks SFP and SFP+ Modules
100FX SFP module for 100-Mbps Ethernet (fast Ethernet) ports (see 100FX SFP Module for Fast
Ethernet Ports)
SR SFP+ (see SR SFP+ Module)
LR SFP+ (see LR SFP+ Module)
ER SFP+ (see ER SFP+ Module)
LRM SFP+ (see LRM SFP+ Module)
ZR SFP+
10/100/1000BASE-T copper SFP and industrial grade module
The information in this guide about hardware platform support for each type of SFPs is current as of the date this guide was published. Support for specific SFP types may have been added to other switches or I/O modules besides those listed in this guide. For current information about hardware support and the minimum required software for SFPs, refer to the most recent version of the ExtremeXOS Hardware and Software Compatibility Matrix.
Technical specifications for all SFP modules are listed in Technical Specifications.

SX and Industrial Grade SX SFP Modules

The SX (part no. 10051) and Industrial Grade SX (part no. 10051H) SFP modules provide a 1000BASE-X optical connection using LC connectors and multimode fiber cable up to 550 meters long.
The SX SFP module conforms to the 1000BASE-SX standard.
The SX SFP module operates at a commercial temperature range (-40C to 70C). The Industrial Grade SX SFP module operates at a wide temperature range (-40C to 85C).
SX and Industrial Grade SX SFP modules are supported in the following Extreme Networks devices:
BlackDiamond 8800 series switches
BlackDiamond X8 switch
BlackDiamond 10808 switch
BlackDiamond 12800 series switches
BlackDiamond 20800 series switches
Summit X150 series switches
Summit X250e series switches
Summit X440 series switches
Summit X450 series switches
Summit X450a series switches
Summit X450e series switches
Summit X460 series switches
Summit X480 series switches
Summit X650-24x switch: ports 1 through 22, VIM1 module ports
Summit X670 series switches
E4G series routers (Ethernet ports)
Summit WM3000 series controllers
Pluggable Hardware Installation Guide 13
Extreme Networks SFP and SFP+ Modules
Optical Budget Calculation
When you plan an installation using the SX SFP module, Extreme Networks recommends that 3 dB of the total budget be reserved for losses induced by cable splices or connectors and operating margin.
There is no minimum attenuation or minimum cable length restriction.
For technical specifications for the SX and Industrial Grade SX SFP, see Technical Specifications.

LX and Industrial Grade LX SFP Modules

The LX (Part No. 10052) and Industrial Grade LX (Part No. 10052H) SFP modules provide a 1000BASE­X optical connection using LC connectors and single-mode fiber (SMF) cable up to 10 km long.
The LX SFP module conforms to the 1000BASE-LX standard.
The LX SFP module operates at a commercial temperature range (-40C to 70C). The Industrial Grade SX SFP module operates at a wide temperature range (-40C to 85C).
LX SFP modules are supported on the following Extreme Networks devices:
BlackDiamond 8800 series switches
BlackDiamond X8 switch
BlackDiamond 10808 switch
BlackDiamond 12800 series switches
BlackDiamond 20800 series switches
Summit X150 series switches
Summit X250e series switches
Summit X440 series switches
Summit X450 series switches
Summit X450a series switches
Summit X450e series switches
Summit X460 series switches
Summit X480 series switches
Summit X650-24x switch: ports 1 through 22, VIM1 module ports
Summit X670 series switches
E4G series routers (Ethernet ports)
Optical Budget Calculation
Measure cable plant losses with a 1310 nm light source and verify this to be within budget.
When you calculate the maximum distance attainable using optical cable with a specified loss per kilometer (for example 0.25 dB/km), Extreme Networks recommends that 3 dB of the total budget be reserved for losses induced by cable splices or connectors, and operating margin. There is no minimum system budget or minimum cable length restriction because the maximum receive power is the same as the maximum transmit power. There is no minimum attenuation or minimum cable length restriction.
Pluggable Hardware Installation Guide 14
Extreme Networks SFP and SFP+ Modules
For technical specifications for the LX and Industrial Grade LX SFP, see Technical Specifications.

ZX SFP Module

The ZX SFP module is a long-haul SFP that provides a 1000BASE-X optical connection using LC connectors and SMF cable up to 80 km long.
ZX SFP modules are supported on the following Extreme Networks devices:
BlackDiamond 8800 series switches
BlackDiamond X8 switch
BlackDiamond 10808 switch
BlackDiamond 12800 series switches
BlackDiamond 20800 series switches
Summit X150 series switches
Summit X250e series switches
Summit X440 series switches
Summit X450 series switches
Summit X450a series switches
Summit X450e series switches
Summit X460 series switches
Summit X480 series switches
Summit X650-24x switch: ports 1 through 22, VIM1 module ports
Summit X670 series switches
E4G series routers (Ethernet ports)
Optical Budget Calculation
Measure cable plant losses with a 1550 nm light source and verify this to be within budget.
When you calculate the maximum distance attainable using optical cable with a specified loss per kilometer (for example, 0.25 dB/km), Extreme Networks recommends that you reserve 3 dB of the total budget for losses induced by cable splices or connectors and operating margin. A minimum system budget or attenuation is required to prevent saturation of the receiver.
For technical specifications for the ZX SFP, see Technical Specifications.

1000BASE-BX Bi-Directional SFP Modules

The 1000BASE-BX SFP modules include the 1000BASE-BX-U SFP module and the 1000BASE-BX-D SFP module.
These two SFP modules are used together to permit a bidirectional Gigabit Ethernet connection using a single strand of SMF cable and LC connectors. The 1000BASE-BX-D SFP operates at wavelengths of 1490 nm TX/1310 nm RX, and the 1000BASE-BX-U SFP operates at wavelengths of 1310 nm TX/1490 nm RX. The 1000BASE-BX-U SFP module is always connected to the 1000BASE-BX-D SFP module. The
Pluggable Hardware Installation Guide 15
Extreme Networks SFP and SFP+ Modules
maximum transmission distance for this connection is 10 km. The 1000BASE-BX SFP modules conform to the IEEE 802.3ah 1000BASE-BX10 standard.
The 1000BASE-BX SFP modules are supported on the following Extreme Networks devices:
BlackDiamond 8800 series switches
BlackDiamond X8 switch
BlackDiamond 10808 switch
BlackDiamond 12800 series switches
BlackDiamond 20800 series switches
Summit X150 series switches
Summit X250e series switches
Summit X440 series switches
Summit X450 series switches
Summit X450a series switches
Summit X450e series switches
Summit X460 series switches
Summit X480 series switches
Summit X650-24x switch: ports 1 through 22, VIM1 module ports
E4G series routers (Ethernet ports)
For technical specifications for the 1000BASE-BX SFP, see Technical Specifications.

1100FX SFP Module for Gigabit Ethernet Ports

The 100FX SFP module for Gigabit Ethernet (GE) ports (part number 10063) provides optical links up to 2km long using multimode fiber cable.
The 100FX SFP for GE ports conforms to the 100FX-MMF standard.
The 100FX SFP modules are supported in the following Extreme Networks devices:
BlackDiamond 8800 series switches
G24x I/O module
MSM-G8x module
G48Xa I/O module
BlackDiamond 20800 series switches
Summit X440 series switches
Summit X450-24x switch: ports 5 through 24 (not supported on combination ports)
Summit X450a-24x, X450a-24xDC switches: ports 1 through 20 (not supported on combination
ports) E4G series routers (Ethernet ports; not supported on E4G-400 combination ports)
For technical specifications for the 100FX SFP for Gigabit Ethernet ports, see Technical Specifications.
Pluggable Hardware Installation Guide 16
Extreme Networks SFP and SFP+ Modules

Dual-speed 100FX/1000LX SFP Module

The dual-speed 100FX/1000LX SFP module operates at either 100 Mbps or 1000 Mbps over SMF links up to 10 km long.
Operating at 100 Mbps, the dual-speed SFP conforms to the 100BASE-LX standard. Operating at 1000 Mbps, the dual-speed SFP conforms to the 1000BASE-LX standard.
The dual-speed 100FX/1000FX SFP modules are supported in the following Extreme Networks switches:
BlackDiamond 8800 series switches
BlackDiamond 12800 series switches
BlackDiamond 20800 series switches
Summit X440 series switches
Summit X450-24x switch: ports 5 through 24 (not supported on combination ports)
Summit X450a-24x, X450a-24xDC switches: ports 1 through 20 (not supported on combination
ports) E4G series routers (Ethernet ports)
Optical Budget Calculation
The 100FX/1000LX SFP module complies with the 100FX-SMF standard.
To use the 100FX/1000LX SFP module in 100FX-MMF operation, a minimum attenuation of 6 dB is required. After the SFP module is installed, connect a 6-dB attenuator to the transmitter side (Tx) of the SFP module. Next, connect the attenuator to the single-mode end of a mode conditioning patch cord. The mode conditioning patch cord transitions the SFP module from SMF to MMF operation.
When in SMF operation, 100FX-SMF or 1000LX, measure cable plant losses with a 1310 nm light source and verify this to be within budget. When you calculate the maximum distance attainable using optical cable with a specified loss per kilometer (for example 0.25 dB/km), Extreme Networks recommends that 3 dB of the total budget be reserved for losses induced by cable splices or connectors and operating margin.
Note The 100FX/1000LX SFP module detects link status based only on the presence of light in the
receive cable. Therefore, if a single strand is broken, the link partner on the other port will not detect link down.
For technical specifications for the 100FX/1000LX SFP, see Technical Specifications.

LX100 SFP Module

The LX100 SFP module provides a 1000BASE-X optical link up to 100km long using LC connectors and SMF cable.
The LX-100 SFP modules are supported on the following Extreme Networks devices:
Pluggable Hardware Installation Guide 17
Extreme Networks SFP and SFP+ Modules
BlackDiamond 8800 series switches
BlackDiamond X8 switch
BlackDiamond 10808 switch
BlackDiamond 12800 series switches
BlackDiamond 20800 series switches
Summit X150 series switches
Summit X250e series switches
Summit X440 series switches
Summit X450 series switches
Summit X450a series switches
Summit X450e series switches
Summit X460 series switches
Summit X480 series switches
Summit X650-24x switch: ports 1 through 22, VIM1 module ports
Summit X670 series switches
E4G series routers (Ethernet ports)
For technical specifications for the LX100 SFP, see Technical Specifications.

100BASE-LX10 SFP Module

The 100BASE-LX10 SFP module provides a 100-Mbps optical connection using LC connectors and SMF cable.
The maximum transmission distance for this connection is 10 km.
The LX10 SFP module is supported in the following Extreme Networks devices:
Summit X250e series switches: all ports
Summit X150 series switches: combination ports only
Summit X460 series switches
Summit X440 series switches
Summit X480 series switches
E4G series routers (Ethernet ports)
For technical specifications for the 100BASE-LX10 SFP, see Technical Specifications.

100BASE-BX Bi-Directional SFP Modules

The 100BASE-BX SFP modules include the 100BASE-BX-U SFP module and the 100BASE-BX-D SFP module.
These two SFP modules are used together in a Summit family switch to permit a bidirectional 100­Mbps Ethernet connection using a single strand of SMF cable and LC connectors. The 100BASE-BX-U SFP module is always connected to the 100BASE-BX-D SFP module. The 100BASE-BX-D SFP operates at wavelengths of 1550-nm TX/1310-nm RX wavelength), and the 1000BASE-BX-U SFP operates at
Pluggable Hardware Installation Guide 18
Extreme Networks SFP and SFP+ Modules
wavelengths of 1310 nm TX/1550 nm RX. The maximum transmission distance for this connection is 10 km. The 100BASE-BX SFP modules conform to the IEEE 802.3ah standard.
The 100BASE-BX SFP modules are supported in the following Extreme Networks devices:
Summit X250e series switches: all ports
Summit X150 series switches: combination ports only
Summit X440 series switches
E4G series routers (Ethernet ports)
For technical specifications for the 100BASE-BX bi-directional SFP, see Technical Specifications.

100FX SFP Module for Fast Ethernet Ports

The 100FX SFP module for fast Ethernet (FE) ports (part number 10067) provides a 100-Mbps optical link using LC connectors and 1310-nm multimode fiber (MMF) cable.
The maximum transmission distance for this connection is 2 km.
The 100FX SFP module for FE ports is supported in the following Extreme Networks devices:
Summit X250e series switches: all ports
Summit X150 series switches: combination ports only
Summit X440 series switches
E4G series routers (Ethernet ports)
For technical specifications for the 100FX SFP module for fast Ethernet ports, see Technical
Specifications.

SR SFP+ Module

The SR SFP+ module provides a 10-Gbps optical connection using LC connectors and multimode fiber cable up to 300 meters long.
The SR SFP+ module conforms to the 10GBASE-SR standard.
The SR SFP+ module is supported in the following Extreme Networks switches and modules:
BlackDiamond X8 switch
Summit X650-24x switch
VIM1-10G8X versatile interface module for the Summit X650 series switches
XGM2-2sf option card in the Summit X350, X450a, and X450e series switches
XGM3-2sf option card in the Summit X460 series switches
Summit X670 series switches
E4G series routers (Ethernet ports)
For technical specifications for the SR SFP+, see Technical Specifications.
Pluggable Hardware Installation Guide 19
Extreme Networks SFP and SFP+ Modules

LR SFP+ Module

The LR SFP+ module provides a 10-Gbps optical connection using LC connectors and single-mode fiber cable up to 10 kilometers long.
The LR SFP+ module conforms to the 10GBASE-LR standard.
The LR SFP+ module is supported in the following Extreme Networks switches:
BlackDiamond 8800 series switches
BlackDiamond X8 switch
Summit X650-24x switch (ports 1 through 24 on the front panel)
VIM1-10G8X versatile interface module for the Summit X650 series switches
XGM2-2sf option card in the Summit X350, X450a, and X450e series switches
XGM3-2sf option card in the Summit X460 series switches
Summit X670 series switches
E4G series routers (Ethernet ports)
For technical specifications for the LR SFP+, see Technical Specifications.

ER SFP+ Module

The ER SFP+ module provides a 10-Gbps optical connection using LC connectors and single-mode fiber cable up to 40 kilometers long.
The ER SFP+ module conforms to the 10GBASE-ER standard.
The ER SFP + module is supported in the following Extreme Networks switches:
BlackDiamond 8800 series switches
BlackDiamond X8 switch
Summit X650-24x switch (ports 1 through 24 on the front panel)
VIM1-10G8X versatile interface module in the Summit X650 series switches
XGM2-2sf option card in the Summit X350, X450a, and X450e series switches
XGM3-2sf option card in the Summit X460 series switches
Summit X670 series switches
E4G series routers (Ethernet ports)
For technical specifications for the ER SFP+, see Technical Specifications.

LRM SFP+ Module

The LRM SFP+ module provides a 10-Gbps optical connection using LC connectors and multimode fiber cable up to 220 meters long. The LRM SFP+ module conforms to the 10GBASE-LRM standard.
The LRM SFP+ module supports link lengths of 220 meters on legacy multimode fiber (MMF) cable. To ensure that specifications are met over Fiber Distributed Digital Interface (FDDI) grade OM1 and OM2 fibers, the transmitter should be coupled through a mode conditioning patch cord. No mode conditioning patch cord is required for applications over OM3 fiber.
Pluggable Hardware Installation Guide 20
Extreme Networks SFP and SFP+ Modules
The LRM SFP+ is supported in the following Extreme Networks switches:
BlackDiamond 8800 series switches
BlackDiamond X8 switch
Summit X650-24x switch (ports 1 through 24 on the front panel)
VIM1-10G8X versatile interface module in the Summit X650 series switches
XGM2-2sf option card in the Summit X350, X450a, and X450e series switches
XGM3-2sf option card in the Summit X460 series switches
Summit X670V-48x switch
E4G series routers (Ethernet ports)
For technical specifications for the LRM SFP+, see Technical Specifications.

ZR SFP+ Module

ZR SFP+ Module The ZR SFP+ module is a long-haul SFP+ module that provides a 10GBASE-X optical connection using LC connectors and SMF cable up to 80 km long.
ZR SFP+ modules are supported on the following Extreme Networks devices:
BlackDiamond 8800 series switches
BlackDiamond X8 switch
Summit X650-24x switch (ports 1 through 24 on the front panel)
VIM1-10G8X versatile interface module in the Summit X650 series switches
XGM2-2sf option card in the Summit X350, X450a, and X450e series switches
XGM3-2sf option card in the Summit X460 series switches
Summit X670V-48x switch
E4G series routers (Ethernet ports)
Caution In cases where there are more than six available ports, only 50% of the available ports on the switch should be populated when using the SFP+ ZR optic. Populate the ports so that there is one empty port for every two vertical ports to evenly distribute the occupied ports.
Warning To prevent permanent damage to the ZR SFP+ and other equipment: always check the optical input power of the receiver before inserting the fiber. The maximum optical input power for the receiver is -7 dBm. If you use optical loopback for diagnostics purposes, the loopback requires a minimum of 15 dB optical attenuation. The recommended attenuation range is 15 dB to 20dB.
For optical budget calculation measure cable plant losses with a 1550 nm light source and verify this to be within budget. When you calculate the maximum distance attainable using optical cable with a specified loss per kilometer (for example, 0.25 dB/km), Extreme Networks recommends that you reserve 3 dB of the total budget for losses induced by cable splices or connectors and operating margin. A minimum system budget or attenuation is required to prevent saturation of the receiver.
For technical specifications for the ZR SFP+, see Technical Specifications.
Pluggable Hardware Installation Guide 21
Extreme Networks SFP and SFP+ Modules

10/100/1000BASE-T Copper SFP and Industrial Grade SFP Module

The Extreme Networks 10/100/1000BASE-T copper SFP module is compatible with the Gigabit Ethernet standard and 1000 Base-T standard as specified in the IEEE 802.3ab standard. This SFP module provides a 100-Mbps connection using Category 5 cable.
The 10/100/1000BASE-T copper SFP module operates at a commercial temperature range (0C to 70C). The Industrial Grade 10/100/1000BASE-T copper SFP module operates at a wide temperature range (-40C to 85C).
Note If the 10/100/1000BASE-T copper SFP GBIC is plugged into a 10G SFP+ port, the GBIC will function only at 1G speeds.
10/100/1000BASE-T SFP module is supported in the following Extreme Networks devices:
BlackDiamond 8800 series switches
Black Diamond X8 series switches
Summit X440 series switches (not supported on combination ports)
Summit X450 series switches (not supported on combination ports)
Summit X450a series switches (not supported on combination ports)
Summit X450e series switches (not supported on combination ports)
Summit X460 series switches (not supported on combination ports)
Summit X650 series switches
Summit X650-24x switch: ports 1 through 22, VIM1 module ports
Summit X650-24t switch: VIM1 module ports
Summit X670-48x and X670V-48x switches
E4G series routers (Ethernet ports; not supported on E4G-400 combination ports)
For technical specifications for the ZR SFP+, see Technical Specifications.

Prepare to Install or Replace an SFP Module

Complete the following tasks before inserting the SFP module:
1 Inspect and clean the fiber tips, coupler, and connectors. 2 Prepare and clean an external attenuator, if needed. 3 When handling fiber cables, take the following precautions to prevent damage to the cables:
a Do not stretch the fiber. b Make sure the bend radius of the fiber is not less than 2 inches (5.08 cm).
4 Extreme Networks recommends the following guidelines when installing or replacing SFP modules
on an active network: a Use the same type of SFP module at each end of the link, except for the 1000BASE-BX and
100BSE-BX bi-directional SFP modules. The bi-directional SFP modules include a D-type and a U-type. You must use one D-type SFP and one U-type SFP together to allow for a single fiber bidirectional connection.
b Connect one end of the link to the Tx port. Without an attenuator, measure the total loss from
the Tx port to the other site of the link. The total loss must not exceed the total optical system budget.
Pluggable Hardware Installation Guide 22
Extreme Networks SFP and SFP+ Modules

Install an SFP Module

You can add or remove SFP modules in your switch without powering off the system.
Pluggable Hardware Installation Guide 23