Introduction
Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC
Voltage, DC Current, and Resistance testing. Proper use and care of this meter will provide
many years of reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device
indicates that the operator must refer to an explanation in the Operating
Instructions to avoid personal injury or damage to the meter.
WARNING
CAUTION
MAX
600V
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules
listed below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
Function Maximum Input
V DC or V AC 600V AC and DC 200Vrms on the 200mV range
mA DC 200mA DC 250V fast acting fuse
ADC 10A 250V fast acting fuse
Resistance, Continuity 250Vrms 15 seconds max
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 500V above
earth ground.
4. NEVER connect the meter leads across a voltage source while the function switch is in
the current, resistance, or diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and disconnect the power when
making resistance or diode tests.
6. ALWAYS turn off power and disconnect test leads before opening the covers to replace
the fuse or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse covers are in
place and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
This WARNING symbol indicates a potentially hazardous situation, which
if not avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which
if not avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth
ground exceeds 600VAC or VDC.
This symbol adjacent to one or more terminals identifies them as being
associated with ranges that may, in normal use, be subjected to
particularly hazardous voltages. For maximum safety, the meter and its
test leads should not be handled when these terminals are energized.
This symbol indicates that a device is protected throughout by double
insulation or reinforced insulation.
Input Protection Limits
(30 seconds max every 15 minutes)
2
MN42-EU - V1.1 – 07/2010
Controls and Jacks
1. Non-Contact Voltage Sensor
2. LCD Display
3. Function switch
4. Positive jack
5. COM jack
6. 10A jack
Note: Tilt stand, fuse, and battery compartment
are on rear of unit.
Symbols
•))) Continuity
Diode
µ micro (amps)
m milli (volts, amps)
k kilo (ohms)
Ω Ohms
Alternating (AC) current
Direct (DC) current
BAT Battery test
-
+
Low battery icon
1
2
3
4
5
6
3