Specifications
INSTRUCTION MANUAL
Display 2000 count liquid crystal display Units Measurement range -58 to 572oF (-50 to 300oC) Resolution 0.1o to 199.9o, 1o > 199.9o Accuracy ±1.8oF (1oC) from –22 to 452oF (-30 to 250oC) : ±4oF
Sensor length 5” (130mm) Sensor tip diameter 0.57” (14.5mm) Sensor material Stainless steel Auto Off After one hour of operation Operating temperature for display 14 to 122oF (-10 to 50oC) (dial display) Battery one 1.5V LR44 cell or equivalent (A76/G13) cell
oC/o
F selectable
C) outside this range
(2
Operation
Battery Installation/Replacement
Using a coin or a screwdriver, turn the battery compartment cover a quarter turn to the left. Remove the cover and install/replace the battery observing the proper polarity.
Taking Temperature Measurements
1. Slide the ON/OFF switch to turn the thermometer on. The digital display will begin to indicate temperature. If the display does not operate, replace the battery.
2. Slide the
3. Place the sensor disk flat against the surface to be measured and read the temperature on the display.
F/C button to select the desired temperature units.
Considerations
For best results, the probe disk should be held flat against the surface and the surface are should be free of any dirt or substance that will inhibit thermal contact.
The thermometer should not be placed inside any oven or microwave.
Remove the battery from the thermometer if it is not to be used for an extended time period.