Specifications subject to change without notice.
Copyright © 2008 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.
www.extech.com
2/9/09 - R1
Built-in InfraRed Thermometer
Quickly identify overheating motors or locate hot spots on electrical
panels and HVAC vents without contact
True RMS MultiMeter with IR Thermometer
Specifications
Display Counts 40,000 count
Basic Accuracy 0.06%
DC/AC Voltage 0.01mV to 1000VDC
0.1mV to 1000VAC
DC/AC Current 0.01μA to 20A
Resistance 0.01Ωto 40MΩ
Capacitance 0.001nF to 10,000μF
Frequency 0.0001Hz to 40MHz
IR Temperature (30:1 ratio) -22 to 1022°F (-30 to 550°C)
Temperature (Type K) -50 to 1382°F (-45 to 750°C)
Duty Cycle 0.01 to 99.99%
Diode/Continuity Yes
Dimensions 7.25x3.25x2.25"(184x83x57mm)
Weight 12.3oz (349g)
Features:
• Built-in Non-contact InfraRed Thermometer with laser pointer
• True RMS CAT III-1000V, CAT IV-600V rated with
0.06% basic DCV accuracy
• Heavy duty Double molded, water resistant package
• Large backlit 40,000 count LCD with 40-segment bargraph
• Memory for storage and recall of three measurements
• Type K thermocouple contact temperature measurements
• Features include HOLD, RELATIVE and PEAK HOLD
• 1000V input protection on all functions
• Min, Max and Average recording
• Auto power off with disable feature
• Capacitance, Frequency, Diode and Continuity functions
• Complete with double molded test leads, magnetic hanging
strap, Type K bead wire temperature probe, case, and 9V battery
Ordering Information
EX570 ..............True RMS Industrial MultiMeter
EX570-NIST ......EX570 MultiMeter w/ NIST Certificate
EX570-NISTL* ..EX570 MultiMeter w/ Limited NIST Certificate
(Limited NIST - Product certified to all functions except IR Thermometer)
Accessories
TL810................Electrical Test Lead Kit
TP200 ..............Type K Clamp Probe (212ºF/100ºC)
Built-in IR Thermometer quickly identifies
hot spots on electrical panels.
Patented