Extech DV40 User guide

V2.0 6/08
is greater
Range -30 to 230°C (-20 to 445°F)
Resolution 0.1°C/F
Accuracy ± 2.0% of reading or ±2ºC/4ºF whichever
Emissivity settings 0.95 fixed
Distance to Target Ratio 1:1
Voltage Sensitivi ty 50V to 1000V AC
Bandwidth 50/60Hz
Detection distanc e 1” @ 105V
Display 9999 count LCD display
Operating Temperature 0 to 50°C (32 to 122°F)
Operating Humidity 10% to 80% RH
Power Supply 3 LR44 or A76 button batteries
Weight 1.25oz. / 35.5g
Specifications
IR Thermometer
Non-Contact Voltage Detector
General
Storage Temperature -10 to 60°C(14 to 140°F)
Altitude Operating below 2000 meters
Overvoltage Category IV-600V, Category
III 1000V, Pollution Degree 2.
Copyright © 2008 Extech Instruments Corporation
Dimensions/Weight 6.25x1” (159x25mm) / 1.25oz / 35.5g
Safety For indoor use and in accordance with
All rights reserved including the right of reproduction in whole or in part in any form
on a known live circuit to verify proper operation
ensuring that the LED i s working correctly. Continue holding the NCV button.
electrical outlet .
glow.
the probe tip along a length of the cord to assure placing the tip in close proximity
Operating Instructions
1. .IRT measure button
2. LCD display.
3. IRT port
4. Battery compartment
5. NCV detector
6. NCV indicator cone
Voltage Detector and IR Thermometer
User’s Guide DV40 Non-Contact
probe and away from the probe tip
on a known live circuit to verify proper operation
Safety
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector
Instructions in this manual before using this product.
CAUTION: Read, understand and follow Safety Rules and Operating
AC VOLTAGE DETECTION
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector
1. PRESS and HOLD the NCV button.
2. The cone tip will light up for approximately 2 seconds and then turn off,
3. Place the probe tip near the hot conductor or next to the hot side of the
7. NCV measurement button
8. Battery compartment release latch.
This symbol, adjacent to another symbol or terminal, indicates the user
the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use,
Do not attempt to repair this unit. There are no user serviceable parts.
Do not expose the unit to extreme temperatures or high humidi ty
Do not use the unit if it is wet or damaged
Do not apply more than the rated voltage between the probe tip and ground.
Do not operate with the case open
4. If AC voltage is present, the detector cone will produce a steady constant
hazardous voltages may be present Double insulation
BATTERY INSTALLATION
to the live conductor.
NOTE: The conductors in electrical cord sets are often twisted. For best results, rub
latch and sliding the cover down.
1. Access the battery compartment by gently pressing the pocket clip release
surface temperature will appear in the display.
value will remain in the display until the meter turns off (approximately 30
seconds).
The temperature units s election switch
is located in the battery compartment.
sources of energy will randomly trip the sensor. This is normal operation.
NOTE: The detector is designed with high sensitivity. Static electricity or other
2. Insert three LR44 button batteries (observe polarity).
3. Replace and latch the cover
accurate readings position the meter as close as possible to the target..
IR TEMPERATURE MEASUREMENTS
NOTE: The IR thermometer has a distance to target ratio of 1:1. For the most
1. Point the IR sensor toward object to be measured,
2. PRESS and HOLD the IR button.
3. The meter will turn ON, “SCAN” will flash in the display and the measured
4. Release the MEASURE button, “HOLD” will appear and the last measured
You, as the end user, are legally bound (Battery ordinance) to return
all used batteries and accumulators; disposal in the household
garbage is prohibit e d!
You can hand over your used batterie s / accumulator s, gratuitousl y,
at the collection points for our branches in your community or
wherever batteries / accumulators are sold!
Follow the valid legal stipulations in respect of the dis posal of the
that it still good and that it is properly inserted.
NOTE: If your meter does not work properly, check the battery to make sure
device at the end of its lifecycle
Disposal
Displaying °F or °C
Loading...