
User's Guide
Flexible Borescope
Model BR136
Congratulations on your purchase of the Extech BR136 Flexible
Borescope. This device includes a bright light to illum inate the
viewed object and has a Removable 90 degree side viewing
adaptor that rotates 360 degrees. This device is shipped fully
tested and, with proper use, will provide years of reliable
service.
Operation
Slide the Light On/Off button up to turn on the object
illumination light. Slide it down to turn the light off.
Viewing
Look through the eyepiece. The image is
broken up in pixels. This is because individual
optical fibers are used to carry the image from
the end of the borescope to the eyepiece.
Focusing
Turn the knurled portion of the eyepiece to sharpen the image.
This compensates for differences in eyesight only.
Mirror
The borescope is fitted with a 90°
view mirror tip that can be rotated
360°. The mirror tip can also be
removed for straight-on viewing.
Cleaning
1. Wipe the cable down with a lint free cloth to remove
any liquid
2. Immerse the cable with a mild soap solution, gently
clean with a sponge or int free cloth and rinse with
clean water
3. Clean the lens with a cloth dipped in alcohol.
Storage
The BR136 should be completely dried before storage. Wipe
the lenses dry with a cotton swab and clean lens surfaces with
a lens cleaner such as silica wax to prevent water marks
Battery Replacement
Press the battery compartment
release button to remove the battery
compartment from the base of the
handle. Replace the 3 AA batteries
and replace the compartment.
Battery
Compartment
Focus
Light On/Off
Battery Compartment
Release
Side View Adaptor
Depth of Observation: 1 – 6” (30 – 150mm)
Viewing Direction 0°
Side View Adaptor: 90°, Viewing Angle 45°
Shaft Diameter: 0.35” (9mm)
Tip Diameter 0.31” (8mm)
Side View Adaptor Dia.: 0.39” (10mm)
Working Length: 46” (1168mm)
Optical system: fiber optic (7200 fibers)
Illumination LED with 100,000 hr life
Probe Temp. withstand 14°F to 176°F (-10°C to 80°C)
Compatibility Water, diesel, gasoline, brake
fluid, antifreeze, motor oil, gear oil
and kerosene
Power 3 AA batteries
Weight: 13oz. (370g)
Carrying Case Dimensions: 13 x 9.84 x 2.75” (330mm x
250mm x 70mm)
Warranty
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of
defects in parts and workmanship for one year from date of shipment (a six month
limited warranty applies to sensors and cables). If it should become necessary to
return the instrument for service during or beyond the warranty period, contact the
Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit
our website www.extech.com for contact information. A Return Authori zation (RA)
number must be issued before any product is returned to Extech. The sender is
responsible for shipping charges, freight, insurance and proper packaging to
prevent damage in transit. This warranty does not apply to defects resulting from
action of the user such as misuse, improper wiring, operation outside of
specification, improper maintenance or repair, or unauthorized modification. Extech
specifically disclaims any implied warranties or merchantability or fitness for a
specific purpose and will not be liable for any direct, indirect, incidental or
consequential damages. Extech's total liability is limited to repair or replacement of
the product. The warranty set forth above is inclusive and no other warranty,
whether written or oral, is expressed or implied.
All rights reserved including the right of reproduction in whole or in part in any
Technical support: Extension 200; E-mail: support@extech.com
Repair & Returns: Extension 210; E-mail: repair@extech.com
Product specifications subject to change without notice
For the latest version of this User’s Guide, Software updates, and other
up-to-the-minute product information, visit our website: www.extech.com
Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451
Copyright © 2007 Extech Instruments Corporation
Support line (781) 890-7440
form.
BR136 V2.2 5/07