EXTECH 433201A, 433202A User Guide

User's Guide
Microprocessor Calibrator/Thermometer Models 433201A and 433202A
Introduction
Congratulations on your purchase of the Extech 433201A (115V) or 433202A (220V) Microprocessor Thermocouple Calibrator/Thermometer.
In the ‘Measurement’ mode, a millivolt (mV) signal is accepted from a thermocouple and is displayed on the 4-digit LCD display. A built-in temperature offset feature can be used to compensate for variations found in standard thermocouples. By adjusting the offset, measurement accuracy for a particular thermocouple can be optimized for a particular temperature.
In the ‘Source’ mode, a millivolt signal is output to an external device with the corresponding temperature (according to standard temperature tables) displayed on the LCD display. Preset temperature settings (source mode only) according to thermocouple type are stored in five memory locations for easy recall.
If desired, the meter can be switched to the mV mode where Measurement and Source values can be displayed in millivolts rather than temperature.
Careful use of this device will provide years of reliable service.
433201A V1.5 05/07
Description
1. LCD display – Temperature values can be displayed in adjustable display can be easily moved to the best viewing angle.
2. POWER/MODE button – Press to power meter on/off and to select the desired mode of operation. With the meter powered on, momentarily press the POWER/MODE button (<2 sec) to toggle between MEASURE and SOURCE mode. In MEASURE mode the meter displays the temperature or mV value for an attached thermocouple or thermocouple simulator. In the SOURCE mode, the meter outputs a mV signal. To power off, press and hold the POWER/MODE button for more than 2 seconds.
3. FINE/COARSE output adjustment buttons – Use the ▼/▲ buttons to set the desired temperature. Press and hold for COARSE adjustment; momentarily press for FINE adjustment.
oC/o
4.
F button – Press to select the desired unit of measure
5. TYPE button – Press to select a thermocouple type
6. MEM – In SOURCE MODE, the Memory button provides access to five memory locations with preset output values depending on which thermocouple type is being used.
oC/o
F or in millivolts. The
Memory
Location
M1
M2
M3
M4
M5
Type
J, K, C, R, S, N
o
32.0
F
o
(0.0
C)
o
212.0
F
o
(100.0
C)
o
932.0
F
o
(500.0
C)
o
1382.0
F
o
(750.0
C)
o
1832.0
F
o
(1000.0
C)
Type T Type E mV
32.0
(0.0
212.0
(100.0
392.0
(200.0
572.0
(300.0
752.0
(400.0
o
F
o
C)
o
F
o
C)
o
F
o
C)
o
F
o
C),
o
F
o
C)
32.0
(0.0
212.0
(100.0
482.0
(250.0
932.0
(500.0
1382.0
(750.0
o
F
o
C)
o
F
o
C)
o
F
o
C)
o
F
o
C)
o
F
o
C)
10.00mV
25.00mV
40.00mV
50.00mV
0mV
7. Output/Input mini connector – Thermocouples, thermocouple wire, and calibration cables are connected here.
8. AC adaptor/recharger jack
9. Battery compartment – Houses the supplied 9V Nickel Metal Hydride rechargeable battery. An alkaline battery can also be used.
10. Neck Strap Posts- Attach the neck-strap to the two posts on the front corners of the meter.
433201A V1.5 05/07