User’s Guide
AC Voltage Detector
Voltage Detector Model No. 40130
CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.
Safety Symbols
Caution ! Refer to the explanation in this Manual Double Insulation or Reinforced insulation
!
Operating Instructions
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation
WARNING: Risk of Electrocution. Keep hands and fingers on the body of the probe and away from the probe tip
AC VOLTAGE DETECTION
1. Press the audible tone switch (1) to select tone on or off (IN = ON; OUT = OFF)
2. Touch the probe tip (3) to the hot conductor or insert into the hot side of the electrical outlet.
3. If AC voltage is present, the detector light will flash (2) and the audible warning will sound (if enabled).
NOTE: The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the
cord to assure placing the tip in close proximity to the live conductor.
NOTE: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor.
This is normal operation
1
AC VoltageDetector
2
3
Battery Installation
1. Open the battery door (end cap) by gently prying up/out at the pocket clip using a small screwdriver.
2. Insert two AAA batteries (observe polarity).
3. Replace the battery door
NOTE: If your meter does not work properly, check the battery to make sure that it still good and that it is
properly inserted.
End cap
Removal
for battery
replacement
Specifications
Voltage Sensitivity 100 to 300V AC Bandwidth 50/60Hz
Detection distance <0.2” Over voltage Category III 600V
Operating Temperature 32 to 122
Altitude Operating below 2000 meters Relative Humidity 80% up to 31
Battery 2 AAA batteries Dimensions/Weight 6x0.75x1” / 2oz
Safety For indoor use and in accordance with Overvoltage Category III, Pollution Degree 2.
UL Listed The UL mark does not indicate that this product has been evaluated for the accuracy of its readings.
o
F (0 to 50oC) Storage Temperature -4 to 140oF (-20 to 60oC)
o
C, decreasing to 50% at 40oC
Lifetime Limited Warranty
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for the useful life of
the product. This excludes wear from normal use and/or abuse. Proof of original purchase must accompany any claims. If it should
become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at
(781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com (click on Contact Extech and go to Service Department
to request an RA number). A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is
responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to
defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or
repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific
purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or
replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or
implied.
AC VoltageDetector