Exergen TemporalScanner 2000 Series User Manual

EXERGEN
EXERGENEXERGEN
EXERGEN
TemporalScanner
TM
2000 Series
A kinder, gentler way to take temperature
1
Greenes DS, Fleisher GR. (Boston Childrens Hospital). Accu-
racy and tolerability of a non-invasive temporal artery thermome-
ter for use in infants. Pediatric Academic Societies/American
Academy of Pediatrics Conference, 5/2000.
More accurate than ear thermometry
1
Temporal Artery Thermometry
T
he temporal artery (TA) area has a long history of
temperature assessment dating back thousands of
years with recorded references to palpation of the head
for fever assessment. Branching from the external ca-
rotid, the superficial TA courses within about a millime-
ter of the skin’s surface over the lateral forehead, pro-
viding good heat conduction to the skin surface, is
readily accessible, and provides no risk of injury from
being touched. Since it is not an anastomosing vessel,
perfusion remains high and stable, ensuring the reliabil-
ity of conditions for the patented Arterial Heat Balance
method to compute accurate temperatures.
This new, superior class of thermometry has been
shown to improve outcomes and reduce costs by non-
invasively measuring temperature with a degree of
clinical accuracy unachievable with other methods of
thermometry.
3
What is arterial temperature?
Arterial temperature is the same temperature as the blood flowing from the heart via the aorta. It is the best determinate of body temperature, and unaffected by the artifactual errors and time delays of oral and rectal methods.
What is the TemporalScanner?
The TemporalScanner is an infrared thermometer designed for non-invasive temperature assessment at the temporal artery (TA). It is a kinder, gentler way to take temperature, and a better method for patient and clinician alike. It is breakthrough technology.
How does it work?
Temperature is measured by gently stroking the TemporalScanner across the forehead, and includes a momentary touch of the probe to the neck area behind the ear lobe, to account for any cooling of the forehead as a result of diaphoresis. The patented arterial heat balance technology (AHB
TM
) automatically measures the temperature of the skin surface over the artery and ambient temperature, synthesizing the two to produce arterial
About Temporal Artery Temperature
4
temperature by sampling and calculating these paired readings some 5000 times with each use.
How accurate is it?
It has been clinically proven in all departments for all patients in premier university hospitals and proven to be more accurate than ear thermometry.
What are the benefits of TA thermometry?
Besides the inherent accuracy, as a site for temperature measurement, TA presents many benefits: no risk of injury for patient or clinician, eliminates the need for disrobing or unbundling, and is suitable for all ages.
Unique to infrared thermometry, the instrument can be used with or without disposable covers, thereby providing a substantial cost savings unavailable with other methods of thermometry.
About Temporal Artery Temperature
5
Probe Cone Probe Sensor Lens
Probe
LCD Display Screen
LED Indicator Light
ON Button
Automatic turn-off in 30 seconds
Product Map
LED Indicator Light
Thumb-Push Ridges
Battery Compartment
9-volt battery
6
Loading...
+ 14 hidden pages