Excalibur RS-360-EDPB Operation Manual

Page 1
DELUXE KEYLESS REMOTE START SYSTEM
User Feature Programming: Ignition on, off, press valet 5 times
Transmitter/Controller Operations: LOCK/ARM: Press and release “lock” once UNLOCK/DISARM: Press and release “unlock” once TRUNK RELEASE/2ND CH: Press “trunk” for 3 seconds REMOTE START: Press “start” twice in 5 seconds
(see user feature #8 for options)
the alarm
Technology
RS-360-EDPB
1
2
3
4
The 1-Way Transmitter Part number: 1411-03 Battery: 1 x CR2032 Frequency: 433MHz
1. LOCK button
2. UNLOCK button
3. TRUNK button
4. START button
Feature Programming:
1. Turn the ignition key “on, then “off”
2. Within 7 seconds of step 1, press the valet switch 5 times (user features) or 10 times (installer features). This siren/horn will sound.
3. Press the valet switch the number of times equal to the feature number you wish to access.
4. Press the controller/transmitter button that corresponds to the desired setting.
5. To change additional features, repeat steps 3-4.
6. To exit programming, turn the ignition key “on”, then “off” or the system will exit automatically if there is a 10 sec­ond delay between any steps.
Tach Learning Procedure:
1. Turn the ignition key “on”
2. Within 10 seconds of step 1, press the brake pedal 5 times. The siren/horn will chirp 5 times.
3. Start the engine with the key. When tach is successfully learned, the status light will turn on solid.
4. If you need to relearn a later tach signal due to cold start/ high idle, you can press the valet switch once to learn the current tach signal. The status light will turn off and back on to indicate it has relearned.
Programming Controllers/Transmitters:
1. Be sure to have all controllers/transmitters present and be sure the system is in a disarmed/unlocked state.
2. Turn the ignition key “on”.
3. Within 7 seconds of step 1, press the valet switch 5 times. The siren/horn will sound.
4. Press LOCK on one transmitter/controller until you hear a single chirp.
5. Repeat step 4 for each transmitter/controller to be pro­grammed.
6. To exit programming, turn the ignition key “off” or the sys­tem will exit automatically if there is a 10 second delay between any steps.
Programmable Features Matrix
# Feature
1 Remote Start Run Time 10 min 5 min 15 min 20 min
2 Flashing Light Conrmations
3 Conrmation Chirp Volume Low Med-Low Med-High High
4 BROWN Wire: Siren / Pulsed Horn Pulse LOW Pulse MED Pulse HI Steady Siren
5 Ignition Lock / Unlock Off Ign On = Lock Ign. Off = Unlock Lock + Unlock
6 Door Open Bypass for Feat. #5 On Off
CONVENIENCESECURITYINSTALLER ONLY
7 Unlock w/ Trunk Release On Off
8 RS Activation (Remote) Start x 1 Start x 2 Start x 3 Start x 4
9 Last Door Arming Off On w/o Lock On w/ Lock
10 Automatic Rearming Off On w/o Lock On w/ Lock Enhanced
11 Conrmation Chirps Siren + Horn Siren Only On Demand Off
12 Anti-Carjacking Ignition Door Ignition + Door Off
13 Secure Code Read Operation Guide For Programming Instructions
14 Ignition Override On Off
15 Alarm Trigger Duration 30 sec 60 sec 90 sec 120 sec
16 Arming Delay 3 sec 15 sec 30 sec 45 sec
17 Open Door Warning Upon Arming On Off
Installer Feature Programming: Ignition on, off, press valet 10 times
1 RS Activation (WHITE/BLUE wire) 1 Pulse 2 pulses 3 pulses 4 pulses
2 PINK/WHITE Wire Ignition Accessory Starter
3 Engine Detection Tachless Hi Tachless Lo Tach Wire Data-tach Crank Only
4 Gasoline or Diesel Engine Gasoline 15 sec Diesel 20 sec Diesel 30 sec Diesel
5 Light Relay Function Dome Light Start Ignition Accessory Status
6 Blue Sat Port BLUE Wire Ignition Status
7 Crank Time 0.75 sec 1 sec 1.5 sec 2.25 sec
8 Door Lock/Unlock Outputs 0.8 sec 3 sec Double Unlock Total Closure
9 Remote Start Lock Control Off
10 Turbo Timer Off 1 min 2 min 3 min
11 Manual Transmission On Off
12 Data Port Protocol
13 Alarm Functions On Off
14 Pulse Ign. on Disarm On Off
15 Lock On Prewarn On Off
16 Starter Interrupt Alarm Only Anti-grind Only Alarm/Anti-Grind Automatic
17 Low Temp Crank Extender 0 ms 200 ms 300 ms 400 ms
18 Arm/Disarm or CH. 4/5 Arm/Disarm Arm/CH. 5 CH. 4/Disarm CH. 4/CH.5
19 Horn Relay Function Horn Ignition Trunk Release
20 Low Current/Motorcycle Mode On Off
Lock Button (Brake x 1)
Unlock: ON RS: ON
Green: DBI Black: DBI
Unlock button (Brake x 2)
Unlock: ON RS: Flash
Lock after Start
Green: iData Black: iData
Trunk button (Brake x 3)
Unlock: Flash RS: ON
Pulse After Start below freezing
Unlock before Start
Green: DBI Black: iData
Start button (Brake x 4)
Unlock: Flash RS: Flash
Pulse After Engine Off
Lock + Unlock
Green: iData Black: DBI
Pulse After Start
Lock + Unlock (Brake x 5)
Horn
Page 2
RS-360/260-EDPB Wiring Overview Diagram
Window-mount Receive / Transmit Module
Status Lights
Valet
Switch
- OR -
Door Trigger (-) Input - GREEN
Door Trigger (+) Input - VIOLET
Light Relay N/O (+/-) Input - BLACK/RED
Trunk Release/CH2 (-) Output - RED/WHITE
Light Relay COM Output - GREEN/VIOLET
Starter Interrupt (-) Output - ORANGE
Flashing Light (-) Output - WHITE/BLACK
System Ground (-) Input - BLACK
Brake (+) Input - BROWN/RED
Neutral Safety (-) Input - BLACK/WHITE
Light Relay N/C (+/-) Input - WHITE/RED
Hood Trigger (-) Input - GRAY
Flashing Light (+) Output - WHITE
Horn Relay N/C (+/-) Input - BROWN/BLACK
Horn Relay COM Output - BLUE/BLACK
Horn Relay N/O (+/-) Input - VIOLET/BLACK
18 PIN HARNESS
Tach Input - VIOLET/WHITE
Siren (+) Output - BROWN
Valet Switch
( ( (ECHO) ) )
Status Lights
Remote Start Activation (-) Input - WHITE/BLUE
OEM Alarm Arm / CH4 (-) Output - LT. GREEN/RED
OEM Alarm Disarm / CH5 (-) Output - LT. GREEN/BLACK
3rd Channel (-) Output - PINK
Arm Alarm (-) Input - WHITE
Disarm Alarm (-) Input - BROWN
WIRE LEGEND
Hard wire connection required
Supported via DATA port(s)
BLADE
Harness Port
Black BLADE Programming / interafce Module Data Port
Green Interface Module Data Port
10 AMP
Constant 12v (+) Input - RED/WHITE
Ignition #2 (+) Output - PINK/WHITE
6 PIN POWER HARNESS
Constant 12v (+) Input - RED
Start (+) Output - VIOLET
Ignition #1 (+) Input/Output - PINK
Accessory (+) Output - ORANGE
6 PIN AUX HARNESS
Antenna
30 AMP
30 AMP
Status Light
Valet Switch
3 PIN SAT. RELAY PORT (RED) Start (-) Output - GREEN Constant 12v (+) Output - RED Ignition (-) Output - BLUE
3 PIN SAT. RELAY PORT (BLUE) Accessory (-) Output - GREEN Constant 12v (+) Output - RED Status (-) Output - BLUE
4 PIN DOOR LOCK PORT Unlock #2 (-) Output - PINK Unlock #1 (-) Output - BLUE Constant 12v (+) Output - RED Lock (-) Output - GREEN
BLADE Docking Port (Bottom of module)
Backup Battery Port
Slide Bracket For Backup Battery & Other Accessories
4 PIN SENSOR PORTS Constant 12v (+) Output - RED Ground (-) Output - BLACK Trigger (-) Input - BLUE Pre-warn (-) Intput - GREEN
RS-360/260-EDPB Parts List
Part Number Description
REC-1N+ Window mount antenna module
H-RS6B 6-pin/6-wire main power harness, 50cm long
H-RS18A 18-pin/18-wire secondary harness
H-RS6C 6-pin/6-wire small accessory harness
H-ANT-ECHO-COLOR-B Antenna module harness
DLP-N4 4-pin/3-wire door lock/unlock harness
RS-OUTPUT 3-pin/3-wire satellite relay port harness
AU-47 Pinswitch
www.caralarm.com | www.omegaweblink.com | www.wiresheet.com | 800.554.4053