80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
3.5 Amps
60/50 Hz
500 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 8.7%, 50% Load)
0.42 0.66 58.73% 10% 63.80 11.82/0.02 3.38/1.25 5.16/1.25 5.15/0.24 50.39 78.98%
0.58 0.89 29.77% 20% 118.59 11.83/0.05 3.38/2.49 5.14/2.48 5.13/0.48 100.92 85.10%
1.28 0.98 8.70% 50% 286.60 11.88/0.12 3.36/6.23 5.09/6.18 5.09/1.19 250.45 87.39%
2.60 0.99 9.45% 100% 589.50 12.09/0.24 3.33/12.47 5.03/12.34 5.01/2.39 498.05 84.49%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-3.0
-2.0
-1.0
0.0
1.0
2.0
3.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current