www.evertz.com
5601ACO2
Automatic Changeovers
5601ACO2 2RU Automatic Changeover System complete with 2 power supplies,
2 power cords and 2 DB15 cables (BNC cables not included)
LTC/IRIG Inputs and Outputs:
Standard: SMPTE 12M-1 frame rate set by
5601MSC or IRIG-B
Inputs: 2 per 5601MSC
Outputs: 2
Connectors:
Inputs: Female DB15
Outputs: 3-pin male XLR type
Signal Level: Set in 5601MSC
Coaxial Inputs and Outputs:
Type: Depends on signal connected from
5601MSC
HD-SDI, SD-SDI, Analog TG, AES,
DARS, bi-level or tri-level sync, colour
black, 10MHz, Word Clock
Number: 16 groups each consisting of two
inputs and one output
Connector: BNC per IEC 61169-8 Annex A
ACO General Purpose Inputs and Output:
Inputs:
GPI1: Master select in Manual GPI control mode
Low: Selects Master A
High: Selects Master B
GPI2: Future use
Outputs:
GPO1: Low: Master A is selected
High: Master B is selected
GPO2: Low: Master A & Master B differ or
PSU failure
High: Master A and B have equivalent
signals
Type:
Inputs: Opto-isolated input with internal pull-up
to +5V
Outputs: Normally closed relay to ground.
10kW internal pull-up to +5V when relay
is in active position
Connector: 4 pins plus 2 ground pins on 12-pin
removable terminal block
Signal Level: +5V nominal
MSC General Purpose Inputs and Output:
Inputs: 2 GPI inputs connected to both
Master A and Master B
Outputs: 2 GPI outputs connected from Master
A through AUXI/O A
2 GPI outputs connected from Master
B through AUXI/O B
Connector: 6 pins on 12-pin removable terminal block
Signal Level: As specified in 5601MSC manual
Changeover conditions:
Changeover is a voting system based on which source has the
most good signals and that the good signals on the current
master are also present on the backup master. The input
signals are considered good according to the following criteria:
Video: Level below 70 IRE
Sync: H timing detect
10MHz: 3dB level below 0.3V p-p
DARS: Sync word error
LTC: Level below 0.3V p-p
Incorrect sync word
Electrical:
Power: Auto ranging 100-240V AC,
50/60Hz, 40W
Configuration: Dual redundant supplies
Fuse Rating: 250V, 1 amp, time delay
Safety: ETL Listed
Complies with EU safety directives
EMI/RFI: Complies with FCC Part 15 Class A
Complies with EU EMC Directive
Physical:
Dimensions: 19" W x 3.5" H x 11.5" D.
(483mm W x 90mm H x 292mm D)
Weight: 16lbs (3.5kg)
Specifications
Ordering Information
• Three protected switches select automatic, front panel or GPI activation
of changeover
• Front panel status LEDs show the health of each of the inputs
• Front panel status LEDs show the operational modes of the changeover
• Redundant power supply standard
• Push button to show cause of last changeover
• Dual hot swappable power supplied and fans
• Hot swappable main board
• GPIO input/outputs
• Automatic changeover is a voting system based on which source has the
most valid signals and that the valid signals on the present master are
also on the backup
• VistaLINK
®
control for device configuration and status monitoring
(5601ACO2 and 5601ACO2 only)
• 6 video/sync or other coaxial signals
• 10MHz frequency reference
• Word clock output
• DARS and 2 AES
• 2 Longitudinal (LTC/EBU) timecode outputs
• 8 SD/HD/3G outputs
• 2 Analog video test signal output
Features & Benefits