Everstar Mpk-10cr-1 Owner's Manual

5 (1)

USE & CARE MANUAL

PORTABLE AIR CONDITIONER

Read and follow all safety rules and operating instructions before first use of this product.

Table Of Contents

 

 

Page

Introduction.......................................................................................

2

Electrical Specifications....................................................................

3

Energy-Saving Tips...........................................................................

4

Window Installation...........................................................................

4

Operating Instructions.......................................................................

5

Care and Maintenance....................................................................

14

Remote Controller Features............................................................

15

Air Conditioner Warranty.................................................................

18

Unit Parts Identification

Operation Panel

Adjustable Vertical

Vertical Louver Louver

Blades

Carrying Handle

(both side)

Water Tank

Caster

1

Introduction

This Owners Manual will provide you with valuable information necessary for the proper care and maintenance of your new appliance. If properly maintained, you appliance will give you many years of trouble free operation. Please take a few moments and read the instructions thoroughly and familiarize yourself with all of the operational aspects of this appliance.

Your Portable Air-Conditioner is a multi-functional room air-exchanging, air-processing appliance, designed to offer you the functions of: Cooling, Dehumidifying and Independent Fan. This unit can be conveniently moved from room to room within your home and setup in just minutes.

It is recommended that the air processing appliance is in an upright position at all times for proper operation and efficiency. If the air processing appliance has been placed in a horizontal ( unit placed on side) position, the unit must be placed in an upright position for a minimum of two hours prior to operation.

For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with the following information which is located on the manufacturers nameplate located on the rear panel of the unit.

Model Number:

Serial Number:

Date of Purchase:

Dealer"s Name and Address:

This information will be required if your unit requires servicing and/or for general inquiries. Keep these instructions for future reference.

!This symbol denotes a caution or warning.

!

CAUTION

!

Do not leave this unit unattended in a space where people or animals who cannot react to a failed unit are located. A failed unit can cause extreme overheating or death in such an enclosed, unattended space.

2

Electrical Specifications

1.All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding the following instructions, contact a qualified electrician.

2.Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit.

3.This unit draws 9.6 amps (nameplate rated) under Cooling mode and may be used in any properly wired, general purpose 15 amp household grounded receptacle.

4.For your safety and protection, this unit is grounded through the power cord plug when plugged into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly grounded, please consult a qualified electrician. DO NOT USE PLUG

ADAPTERS OR EXTENSION CORDS.

5.The manufacturers nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit.

6.To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing and/or servicing.

Table 1

Suggested Individual Branch Circuit

Nameplate Amps

AWG Wire Size

7.4 to 12.0

14

AWG-American Wire Gage

Based on copper wire at 60oC temperature rating.

Table 2

Receptacle and Fuse Types

Rated Volts

115

Amps

15

 

 

Wall Outlet

 

 

 

Fuse Size

 

 

 

Time Delay Fuse

Plug Type

(or circuit breaker)

 

Unit Specifications:

 

MODEL MPK-10CR

Cooling Capacity

 

10000 Btu/h

Heating Capacity

 

Not Applicable

Dehumidifying Capacity

 

76 Pints (36L/24Hrs)

Noise Level

 

Less than 54 dB(A)

Power Source

 

115V / 60Hz

Refrigerant

 

R22

 

Water Tank Capacity

 

3.5L(7.4Pints)

Unit Weight

 

33kg(72.7 lb.)

Unit Dimensions(inches)W

D H

12.8" 18.1"

33.1"

Unit Dimensions(cm)W D

H

32.5 46

84

Fan speeds

 

3

 

Control Panel(llluninated)

 

Soft Touch Controls

Time of Day Clock

 

No

 

Auto - Timer

 

Yes

 

Power Consumption:

 

 

 

Cooling

 

1100Watts(9.6 Amps)

Heating

 

Not Applicable

Fan

 

90W(0.8Amps)

 

 

 

 

NOTE: Product features or Specifications as described or illustrated are subject to change without notice.

3

Energy-Saving Tips

This appliance is designed to be highly efficient in energy savings. Follow these recommendations for greater efficiency.

1)Select a thermostat setting that suits your comfort needs and leave at that chosen setting.

2)The air filter is very efficient in removing airborne particles. Keep the air filter clean at all times.

3)Use drapes, curtains or shades to keep direct sunlight from penetrating and heating room, but do not allow drapes or curtains to obstruct the air flow around the unit.

4)Start your air conditioner before the outdoor air becomes hot and uncomfortable. This avoids an initial period of discomfort while the unit is cooling off the room. Use of the automatic start / stop programmable TIMER feature can be a major asset in this regard if utilized to the fullest extent.

5)When outdoor temperatures are cool enough, turn the air conditioner off and use the FAN MODE on HIGH, MED or LOW. This circulates indoor air, providing some cooling comfort and utilizes less electricity.

Window Installation

 

Electric Shock Hazard

 

 

To avoid the possibility of personal

 

injury, disconnect power to the unit

 

before installing or servicing.

!

CAUTION

!

To avoid installation/operation difficulties,

read these instructions thorughly.

Installation Accessories Fig.1

 

Description

Qty

Flexible exhaust hose with adapters.........

3/pc

stretches from 31" (79cm) up to 89" (226cm)

Window exhaust adapter(flat mouth)...........

1pc

Adjustable window/window slider kit....

2/pc

from 261/2" (67.3cm) up to 477/8"(121.6cm)

 

Drain hose connector..................................

1 pc

SPECIAL NOTE: Exterior drain hose extension (direct drain) is not included with this unit and can be purchased through any local Hardware Store.

The exhaust/window kit must be installed at all times when the unit is operating under the COOLING mode. There should be at least 11.8"(30 cm) clearance between the unit and any other objects or building structure. The unit should be installed on a level surface. The window kit does not have to be installed during operation of the remaining two modes. (Dehumidifying/Fan).

Fig. 1 Installation Accessories

Flexible Exhaust Hose

Window Exhaust

Adapter

31" - 89"

Transition Adapter

 

Unit Connection

 

4

 

Everstar Mpk-10cr-1 Owner's Manual

Window Kit Installation

Your window kit has been designed to fit most

standard "vertical"and "horizontal" window

applications. However, it may be necessary for

you to improvise/modify some aspects of the

installation procedures for certain types of

windows. Please refer to Fig. 2 & Fig. 2a for minimum and maximum window openings.

Water Tank Safety Feature

This unit is equipped with a fail-safe switch mechanism which prevents the unit from condensing water in the event the water tank is accidentally displaced, and / or FULL with water. If this situation occurs, the LED window shows

"P1" and the WATER FULL indicator light will flash red continuously until the water tank is correctly positioned and/or emptied.

NOTE: The fan motor will continue to operate under this condition. This is normal, but no cooling or dehumidifying will occur until the tank is emptied and/or correctly installed (It may take several minutes before the compressor resumes normal operation).

Horizontal Window

 

Window Slider Kit

 

Minimum: 261/2" (67.3cm)

Fig. 2

Maximum: 477/8"(121.6cm)

Vertical

Window

Fig. 2a

Window Slider Kit

Minimum: 4"(10.1cm )

1

Maximum: 73 /2"(186.7cm)

Operating Instructions

Before Starting This Unit

1)Select a suitable location, making sure you have easy access to an electrical outlet.

2)Install the Flexible Exhaust Hose and the

Adjustable Window Slider Kit as depicted in Fig. 3 & Fig. 3a.

3)Plug the unit into a 115V / 60Hz grounded electrical outlet (Refer to the nameplate).

DO NOT USE AN EXTENSION CORD.

4)Make sure the Water Tank is correctly positioned inside the cabinet otherwise the unit will not operate. Fig 4.

5)To turn the unit on, press the POWER key (On / Off Switch). Fig. 5.

Fig. 3

Fig. 3a

Fig. 4

Fig. 5

5

Loading...
+ 14 hidden pages