USE & CARE MANUAL
PORTABLE AIR CONDITIONER
Read and follow all safety rules and operating instructions before
first use of this product.
Table Of Contents
Page
Introduction.......................................................................................2
Electrical Specifications....................................................................3
Energy-Saving Tips...........................................................................4
Window Installation...........................................................................4
Operating Instructions.......................................................................5
Care and Maintenance....................................................................14
Remote Controller Features............................................................15
Air Conditioner Warranty.................................................................18
Operation Panel
Vertical Louver
Blades
Unit Parts Identification
Adjustable Vertical
Louver
Carrying Handle
(both side)
Water Tank
Caster
1
Introduction
This Owners Manual will provide you with valuable information necessary for the proper care and main-
tenance of your new appliance. If properly maintained, you appliance will give you many years of trouble
free operation. Please take a few moments and read the instructions thoroughly and familiarize yourself
with all of the operational aspects of this appliance.
Your Portable Air-Conditioner is a multi-functional room air-exchanging, air-processing appliance, designed
to offer you the functions of: Cooling, Dehumidifying and Independent Fan. This unit can be conveniently
moved from room to room within your home and setup in just minutes.
It is recommended that the air processing appliance is in an upright position at all times for proper operation
and efficiency. If the air processing appliance has been placed in a horizontal ( unit placed on side) position,
the unit must be placed in an upright position for a minimum of two hours prior to operation.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along with
the following information which is located on the manufacturers nameplate located on the rear panel of the
unit.
Model Number:
Serial Number:
Date of Purchase:
Dealer"s Name and Address:
This information will be required if your unit requires servicing and/or for general inquiries.
Keep these instructions for future reference.
This symbol denotes a caution or warning.
!
!
Do not leave this unit unattended in a space
where people or animals who cannot react to a
failed unit are located. A failed unit can cause
extreme overheating or death in such an
enclosed, unattended space.
CAUTION
!
2
Electrical Specifications
1. All wiring must comply with local and national
electrical codes and be installed by a qualified
electrician. If you have any questions regarding
the following instructions, contact a qualified
electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installation and
operation of this unit.
3. This unit draws 9.6 amps (nameplate rated)
under Cooling mode and may be used in
any properly wired, general purpose 15 amp
household grounded receptacle.
4. For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether the wall outlets in your home
are properly grounded, please consult a
qualified electrician. DO NOT USE PLUG
ADAPTERS OR EXTENSION CORDS.
5. The manufacturers nameplate is located on the
rear panel of the unit and contains electrical
and other technical data specific to this unit.
6. To avoid the possibility of personal injury, always
disconnect the power supply to the unit, before
installing and/or servicing.
Table 1
Suggested Individual Branch Circuit
Nameplate Amps
7.4 to 12.0
AWG-American Wire Gage
Based on copper wire at 60 C temperature rating.
AWG Wire Size
14
o
Table 2
Receptacle and Fuse Types
Rated Volts 115
Amps 15
Wall Outlet
Fuse Size
Time Delay Fuse Plug Type
(or circuit breaker)
Unit Specifications:
Cooling Capacity
Heating Capacity
Dehumidifying Capacity
Noise Level
Power Source
Refrigerant
Water Tank Capacity
Unit Weight
Unit Dimensions(inches)W D H
Unit Dimensions(cm)W D H
Fan speeds
Control Panel(llluninated)
Time of Day Clock
Auto - Timer
Power Consumption:
Cooling
Heating
MODEL MPK-10CR
Not Applicable
76 Pints (36L/24Hrs)
Less than 54 dB(A)
3.5L(7.4Pints)
33kg(72.7 lb.)
12.8" 18.1" 33.1"
32.5 46 84
Soft Touch Controls
1100Watts(9.6 Amps)
Not Applicable
10000 Btu/h
115V / 60Hz
R22
3
No
Yes
Fan
NOTE: Product features or Specifications as described or illustrated are subject to change without notice.
3
90W(0.8Amps)
Energy-Saving Tips
This appliance is designed to be highly
efficient in energy savings. Follow these
recommendations for greater efficiency.
1) Select a thermostat setting that suits your
comfort needs and leave at that chosen
setting.
2) The air filter is very efficient in removing
airborne particles. Keep the air filter clean at
all times.
3) Use drapes, curtains or shades to keep
direct sunlight from penetrating and heating
room, but do not allow drapes or curtains to
obstruct the air flow around the unit.
Window Installation
Electric Shock Hazard
To avoid the possibility of personal
injury, disconnect power to the unit
before installing or servicing.
!
CAUTION
!
To avoid installation/operation difficulties,
read these instructions thorughly.
4) Start your air conditioner before the outdoor air
becomes hot and uncomfortable. This avoids an
initial period of discomfort while the unit is cooling
off the room. Use of the automatic start / stop
programmable TIMER feature can be a major
asset in this regard if utilized to the fullest extent.
5) When outdoor temperatures are cool enough,
turn the air conditioner off and use the FAN
MODE on HIGH, MED or LOW. This circulates
indoor air, providing some cooling comfort and
utilizes less electricity.
The exhaust/window kit must be installed at all times
when the unit is operating under the COOLING mode.
There should be at least 11.8"(30 cm) clearance
between the unit and any other objects or building
structure. The unit should be installed on a level
surface. The window kit does not have to be installed
during operation of the remaining two modes.
(Dehumidifying/Fan).
Installation Accessories Fig.1
Description Qty
Flexible exhaust hose with adapters.........3/pc
stretches from 31" (79cm) up to 89" (226cm)
Window exhaust adapter(flat mouth)...........1pc
Adjustable window/window slider kit....2/pc
from 26 / " (67.3cm) up to 47 / "(121.6cm)
17
28
Drain hose connector..................................1 pc
SPECIAL NOTE: Exterior drain hose extension
(direct drain) is not included with this unit and can
be purchased through any local Hardware Store.
Fig. 1 Installation Accessories
Flexible Exhaust Hose
31 - 89""
Unit Connection
4
Window Exhaust
Transition Adapter
Adapter
Window Kit Installation
Your window kit has been designed to fit most
standard "vertical"and "horizontal" window
applications. However, it may be necessary for
you to improvise/modify some aspects of the
installation procedures for certain types of
windows. Please refer to Fig. 2 & Fig. 2a for
minimum and maximum window openings.
Water Tank Safety Feature
This unit is equipped with a fail-safe switch
mechanism which prevents the unit from
condensing water in the event the water tank is
accidentally displaced, and / or FULL with water.
If this situation occurs, the LED window shows
"P1" and the WATER FULL indicator light will
flash red continuously until the water tank is
correctly positioned and/or emptied.
NOTE: The fan motor will continue to operate
under this condition. This is normal, but no
cooling or dehumidifying will occur until the
tank is emptied and/or correctly installed (It
may take several minutes before the
compressor resumes normal operation).
Horizontal Window
Window Slider Kit
Minimum:
Maximum: 47 / "(121.6cm)
Vertical
Window
1
26 / " (67.3cm)
2
7
8
Fig. 2a
Window Slider Kit
Minimum: 4"(10.1cm )
Maximum: 73 / "(186.7cm)
1
2
Fig. 2
Operating Instructions
Before Starting This Unit
1) Select a suitable location, making sure you
have easy access to an electrical outlet.
2) Install the Flexible Exhaust Hose and the
Adjustable Window Slider Kit as depicted in
Fig. 3 & Fig. 3a.
3) Plug the unit into a 115V / 60Hz grounded
electrical outlet (Refer to the nameplate).
DO NOT USE AN EXTENSION CORD.
4) Make sure the Water Tank is correctly
positioned inside the cabinet otherwise the
unit will not operate. Fig 4.
5) To turn the unit on, press the POWER key
(On / Off Switch). Fig. 5.
Fig. 3
5
Fig. 3a
Fig. 4
Fig. 5