Everspring Industry Co SA823 User Manual

SA823 U-NET REPEATER
p
g
r
r
The SA823 is a signal repeater to extend the range of U-Net two-way wireless technology. It is fully compatible with any U-Net enabled sensors and controller.
The signal repeater is designed to be installed by a system installer in cases where signal reception is poor or extended range is required for the home. The repeater does not alter the existing binding network between gateway and devices, in fact devices do not need to be physically removed from their mounting location when adding the repeater. This allows the installer to service the user in the shortest time possible without disrupting to the home interior.
It comes with installer friendly feature such test mode to indicate signal strength using LED display and audible beeps for areas not in line of sight such as corners. Powered by backup battery, this allows the repeater to be easily placed anywhere while searching for its optimum location. There is the also a Beacon mode which allows the installer to conveniently walk around the home to observe signal strengths from the gateway when deciding on the best location.
Product Overview
Front View
RF Stat
Batt
Rear View
Wall
Tamp
Back
Repeater network overview
The role of the Repeater in a U-Net network can be summarized in the diagram below. Level : Repeaters are distinguished into Level-1
and Level-2 as set by their Level jumper setting. Each pair of Level-1 and 2 repeaters define a unique signal path to the gateway. Signals from each pair will not cross over to another pair.
View with Battery Cover removed
Mode Switch
Level Jumpe
Buzze
Learn Button
Factory
- Level-1: Repeater closest to the gateway. In most cases adding a Level-1 Repeater is sufficient to
cover a wide range. A gateway can have more than one Level-1 Repeaters to branch out at different angles from the gateway.
- Level-2: Repeater to extend signal from Level-1 Repeater. Only one Level-2 repeater can be added for each Level-1 Repeater.
To create the link between the pairs, repeaters must perform U-net binding with each other. Repeaters with the same level cannot bind with each other.
Lastly, like all end devices under the gateway’s network, each repeater must perf orm U-n et binding with the gateway. This ensures the gateway is aware of the repeater’s own condition such as low battery, tamper, etc.
Note: It is advisable to use as few Repeaters as possible in a network in order to reduce signal hops between device and Gateway. Like any wireless network, more signal hops not only mean longer delay in transmission but also adds higher risk of signal interference resulting in lost messages as more devices are added. This degrades the overall network quality.
Join: The repeater becomes associated with an end device through ‘Joining’. This is a loose form of binding that tells a repeater which devices it should repeat signals for and which do not. Joining is a manual process similar to U-net binding except there is no need to remove end devices from their mounting position to activate a learn key. Simply trigger the end device for it to transmit its ID which is then picked up by the repeater. Joining does not disrupt the original U-net binding between end devices with gateway.
Inversely, a device is disassociated from the Repeater through ‘Un-join’. Removing a device from the Repeater’s memory helps to reduce unnecessary transmission of RF signal which will improve overall quality of the network.
LED Table
The table below describes the LED indication at various stages of the unit’s operation.
Pairing stage:
During the Repeater’s pairing activity, Status LED along with the buzzer beeps indicate the status of the paring.
Status Status LED Buzzer Beep
Factory reset state. Repeater not
aired to any Gateway.
Enter pairing mode Steady RED Short beeps every 1 sec, followed by Waiting to bind with gateway, time out
in 30 secs. Pairing successful LED OFF 1 Long beep
Pairing fail after time out or terminated Joining fail because exceed device limit
Device Un-join successful LED OFF 2 Long beep Level-2 Repeater disconnected successful Activate Factory Reset Steady RED Short beeps, followed by 1 long beep
Testing stage (Mode switch set to TEST)
During Test mode, RF LED and the buzzer beeps indicate the signal strength.
RF LED – Test Mode Buzzer beep sound Description
Flash GREEN 3 times Short beep 3 times Signal is Good, Test mode Flash ORANGE 2 times Short beep 2 times Signal is Normal, Test mode Flash RED 1 time Short beep 1 time Signal is Weak, Test mode Flash GREEN 3 times Long beep 3 times Signal is Good, Beacon mode Flash ORANGE 2 times Long beep 2 times Signal is Normal, Beacon mode Flash RED 1 time Long beep 1 time Signal is Weak, Beacon mode
After power up, Blinks RED every 2 secs for 30 secs.
Blink RED, every 1 sec Short beeps every 1 sec
Flashes RED 3 times Short beep 3 times On RED for 1 sec then OFF 3 short beeps
LED OFF 2 Long beep
None
1 lon
beep
1
Status LED – Test Mode Description
k
k
Flashes ORANGE, every 1 sec Test mode activated
Normal usage (Mode switch set to NORMAL): Once the Repeater is installed and set for daily use, the LED display becomes as follows:
Status LED – Daily usage Explanation
Steady GREEN Powered by AC power, Normal mode Flashes GREEN, every 30 secs. Powered by backup battery, Normal mode Flashes RED, every 30 secs. Backup battery is low Flashes ORANGE, every 30 secs. Powered by AC but detected backup battery is low
RF LED
Flash GREEN Signal received, Normal mode Flash RED Repeater Tamper switch activated
Daily usage Explanation
Binding With Gateway
The Repeater supports Auto-Binding feature where it will automatically enter binding mode when first powered up after a factory reset.
1. Remove the wall bracket by pushing it downwards and then remove the battery cover.
2. Prepare three AA 1.5V batteries. Do not insert them into the unit yet.
3. Ensure the Level jumper in the Repeater is set to Level-1.
4. Set a U-net compatible gateway into binding mode. Usually this is achieved by pressing the Link
button on the gateway.
5. Insert the batteries with correct polarity at this point. Within a few seconds a long beep sound will
be heard indicating the pairing is complete.
6. Time-out will occur if the binding process was unsuccessful, indicated by 3 short beeps. If this
happens, refer to the Manual Binding procedure in the Troubleshooting section.
Note: A Repeater must reset back to factory default before it can pair with another gateway. See the Factory Reset section in the Troubleshooting section.
Adding a Device (Join process)
1. Put repeater into Joining mode by pressing the learn button until 3 beeps is over and release.
Repeater will enter learning mode for 30 secs.
2. Bring the repeater in close range to the device, around ~10cm.
3. Simply trigger the device (PIR trigger, door sensor open, etc.) to emit a signal which will be picked
up by the Repeater. Note:
- Unlike binding, there is no need to press learn key on device.
- Refer to the LED Table for details of pairing indicators.
4. Once the signal is picked up by the Repeater, it will emit one long beep sound. Joining process is
complete. From now on Repeater will start routing signal for this device.
5. Time-out will occur if the Joining process is unsuccessful, indicated by 3 short beeps.
Note: PIR motion sensors will have a retrigger interval or sleep period which lasts longer than the Repeater’s 30 secs Join period. If time out occurs, try again when the PIR is ready. If necessary, cover the PIR with a dark cloth when preparing the Repeater.
6. Repeat the steps above for other devices.
Note :
- Each Repeater supports a maximum of 8 devices.
- Keypad and Siren devices are NOT supported by this Repeater.
- Remote keyfobs do not need to Join to any Repeater. All Repeaters will retransmit signals from Remote Keyfobs in the same network.
- A Repeater will Join only devices from the same gateway paired to the Repeater
- A device can Join to only one Repeater at any one time. If the device needs to Join to another Repeater, it must first Un-Join from the first Repeater. The Un-Join procedure is similar to Join procedure except two beeps will be heard when completed.
- If any device is deleted by the gateway, the gateway will inform the Repeater to Un-Join this device from its memory.
Testing
There are two signal test methods provided by the Repeater;
- Test Mode : this tests the signal between the end device to Repeater
- Beacon Mode : this tests the signal between the Repeater to Gateway. It is also used to test signal
between Repeaters.
RF LED Flash Green 3 times Flash Orange 2 times Flash Red 1 time Beep sound* 3 long beeps 2 long beeps 1 long beep
Good Normal Wea
Test Mode
This is used when searching for a good spot to mount the Repeater. In this mode the unit will indicate signal strength for each signal sent by the device.
1. Join a device to the Repeater as described above.
2. Set the Mode switch to Test mode.
3. Place the Repeater at a distance away from the end device.
4. Trigger the device, e.g. open a door sensor or press the on/off button on a smart plug. The
Repeater will indicate the received signal strength as follows:
RF LED Flash Green 3 times Flash Orange 2 times Flash Red Beep sound 3 short beeps 2 short beeps 1 short beep
5. Set the Mode switch back to Normal mode to exit.
Good Normal Wea
1 time
Beacon Mode
In this mode the Repeater transmits a ping signal to the gateway at every 5 sec s interval. The reply signal from the gateway is then measured for strength and indicated by RF LED and buzzer beeps. This feature allows the installer to walk around the premises while observing the signal quality at the spot. This is useful for;
- identifying weak areas for placing a sensor
- testing signal strength between Repeater and Gateway before mounting it permanently
- testing the signal strength between Repeater pairs when adding a second Repeater.
To use Beacon mode with a Gateway;
1. Set the Mode switch to Test mode.
2
g
y
g
y
2. Press the Tamper switch on the Repeater. The ping signal will be sent every 5 secs. The Repeater will indicate the received signal strength as follows:
*same as Test Mode but long beeps instead of short beeps
3. Set the Mode switch back to Normal mode to exit.
A matrix summary of the Test Mode and Beacon Mode can found in Appendix A.
Mounting the Repeater
A clean smooth surface is required to securely mount the Repeater. The unit should be placed on the wall, at least 1.5m high from floor, for improved reception.
1. Use the wall bracket as a template to mark and drill the position of 3 mounting holes on the wall.
2. Fix the wall bracket to the wall using the plastic wall plugs and fixing screws provided.
3. Connect the DC adaptor to DC jack of the unit and place the battery cover over the battery compartment. Note : the unit should always be powered DC adaptor instead of its backup battery.
4. Slide the unit down into its wall bracket ensuring the tamper switch is pressed by the wall bracket as shown below.
Tamper Protection
Tamper protection is activated when the tamper switch is pressed continuously for more than 2 minutes. Removing the unit from its wall bracket will release the tamper switch and generate a full alarm condition.
Maintenance
1.
The unit reports its presence to the gateway every 60 minutes. This way the gateway will be alerted if the Repeater becomes missing.
2. Low Battery: When its backup battery becomes low, the unit will report back to the gateway and
the Status LED will flash every 30secs. Replace the battery the soonest possible to keep the unit operating during a power cut.
Level-2 Repeater Connecting a Level-2 Repeater
This follows the same procedure as binding to a Gateway.
1. Firstly, bind the second Repeater to the Gateway as in the section Binding with Gateway.
2. Once completed, setting its Level jumper to Level-2.
3. Set the unit into pairing mode by press and holding its Learn button for 3 secs until a long beep
sound is heard, then release the button. The unit is now ready to pair for 30 secs.
4. Within 30 secs, set Level-1 Repeater into pairing mode also by performing the previous step
above.
5. Soon both units will emit a long beep indicating both are now connected to each other. Refer to
the LED Table for details of pairing indicators.
Disconnecting a Level-2 Repeater
1. Set the Level-1 Repeater into pairing mode by press and holding its Learn button for 3 secs until a
long beep is heard, then release the button.
2. Within 30 secs, bring the Level-2 Repeater in close range to Level-1 Repeater, around ~10cm
and press the Tamper switch on the Level-2 Repeater.
3. 2 long beeps will be heard on Level-1 Repeater indicating both are now disconnected from each
other.
Note:
- Level-2 will still preserve all the Join devices in its memory. It will continue to serve these devices even after connecting to a new Repeater or directly to Gateway. Only by doing a Factory reset will all the Join devices be erased from the Repeater’s memory.
- Level 3 jumper is for factory use only.
Troubleshooting
The troubleshooting table lists some possible causes and solutions
Symptom Cause of Failure Recommendation
Binding with Gateway does not work. Remote keyfob cannot Join to
Repeater. Keypad and Siren cannot Join to
Repeater. Repeater keeps beeping whenever a
signal is received.
Repeater is added but still cannot achieve desired range.
Cannot pair a second Repeater to first Repeater
Manual Binding
1. Set the unit into pairing mode by pressing and holding its Learn button for 3 secs until a long beep
sound is heard, then release the button. The unit is now ready to pair for 30 secs.
2. Set a U-net compatible gateway into binding mode. Usually this is achieved by pressing the Link
button on the gateway.
3. Within 5 secs the unit will emit a long beep indicating the binding procedure is complete. Refer to
the LED Table for details of pairing indicators.
The Repeater has previously been paired with another
Remote keyfob does not require Join procedure
Keypad and Siren are not supported.
Repeater set to Test Mode Switch Mode jumper to Normal Mode.
1. Range is too far.
2. Signal is blocked by thick wall.
Both Repeaters are set to the same Level
atewa
Perform factory reset on the Repeater. None. All the Repeaters in the network
will transmit si Keep keypad or siren within range of the
Gatewa
1. Set the Repeater to Level-2 and add a Level-1 Repeater in between to extend range.
2. Place Repeater near openings in the wall such as a door or window.
Set one of them to a different Level using the Level jumper.
nals from remote keyfob
3
Reset To Factory Default
0 -
H
0
-
AAA
3
(EU)
)
To reset the unit back to factory default state:
1. Press and hold the Learn button for 3 secs until a long beep sound is heard, then release the button.
2. Within 30 secs, press and hold the Learn button again but this time for more than 6 secs until
another long beep sound is heard. This indicates the reset is complete. The LED will blink every 2 secs indicating no paired ID code is stored its memory.
Specification
Operating temperature range0°C to +50°C Operating humidity 1 Power supply I/P: 10
Backup battery 1.5V Battery life Between 24~48 hrs Frequency range 868MHz
** Specifications are subject to change without notice.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the recei ver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FC C Rules. Ope ration is subject to the following two cond itions: (1) Thi s device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
RF exposure warning
This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a sep a ratio n dist a nce of at lea st 2 0 cm from all pe rsons and mu st not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and
get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for
disposal at least for free of charge.
85% R
240Vac 50/60Hz 0.5A
O/P: DC9V 2000mA
batteries x
/ 923MHz (America
www.everspring.com
50 Sect. 1 Zhonghua Rd Tucheng NewTaipeiCity 236 Taiwan..
4
Appendix A : Repeater test matrix table
A
A
Level-1
Repeater
Level-2
Repeater
To Enter
Observe Results
To Exit
To Enter
Observe Results
Target: End Device Target: Gateway Target: Level-2 Repeater Target: Level-1 Repeater
1. Set Mode switch to 'Test'
2. Trigger/Activate the device
To Enter
1. Set Mode switch to 'Test’.
2. Press Tamper switch on Repeater to start Beacon Mode.
To Enter
1. Set Mode Switch on Level-1 Repeater to 'Test'.
2. Press Tamper switch on Level-2 Repeater to start Beacon Mode.
t every 5 secs:
1. LED Signal strength indicator on both Repeaters.
2. Short Beeps emitted by Level-1 Repeater for signal strength
3. Gateway registers a
N/A
1. LED Signal strength indicator on Repeater
2. Short Beeps emitted by Repeater for signal strength
Observe Results
At every 5 secs:
1. LED Signal strength indicator on Repeater
2. Long Beeps emitted by Repeater for signal strength
3. Gateway registers a Tamper event
Observe Results
Tamper event.
Set Mode switch back to 'Normal'.
1. Set Mode switch to 'Test'
2. Trigger/Activate the device
To Exit
To Enter
Set Mode switch back to 'Normal'.
No specific test mode. Press Tamper switch to send Tamper event to Gateway.
To Exit
Set Level-1 Repeater Mode switch back to 'Normal'.
To Enter
1. Set Mode Switch on Level-1 Repeater to 'Test'.
2. Press Tamper switch on Level-2 Repeater to start Beacon Mode.
t every 5 secs:
1. LED Signal strength indicator on Repeater
2. Short Beeps emitted by Repeater for signal strength
Observe Results
Gateway registers a Tamper event.
N/A
Observe Results
1. LED Signal strength indicator on both Repeaters.
2. Short Beeps emitted by Level-1 Repeater for signal strength.
3. Gateway registers a Tamper event
To Exit
Set Mode switch back to 'Normal'.
To Exit None To Exit
Set Level-1 Repeater Mode switch back to 'Normal'.
5