Everspring Industry Co AC136 User Manual

AC136
Panic Button
Front View
 Panic
ON
/OFF Knob  Panic
ON/
OFF Knob
Inside View
 Battery Compartments
Link Button
 Rear Cover Latch
LED Indicator
Rear View
 Rear Cover
The AC136 Panic Button is a Z-Wave PlusTM enabled device and is fully compatible with any Z-WaveTM enabled network. The device can be set up in a Z-wave network to communicate directly with other end devices such as lighting controllers, or to report directly a Z-wave controller (usually a gateway).
The Panic Button is a portable wireless switch designed to control the Panic/Disarm status of other associated devices thru the Z-WaveTM controller. After receiving the signals emitted by the Panic Button, the Z-WaveTM controller can then give commands or operate according to its own settings. Its great compatibility with Z-WaveTM products makes it suitable for smart home cloud based platforms.
Product Overview
3 3
LINK
55
6
7
4
Adding to Z-WaveTM Network
Auto Inclusion
The detector supports Auto Inclusion feature where it will automatically enter Inclusion mode when first powered up after a factory reset.
1. Gently lever the bottom edge of the front cover to detach it from the main body.
2. Put a Z-Wave Controller into inclusion mode.
3. Insert 2 AAA-size 1.5V alkaline batteries to battery compartment with the correct polarity. The LED on the device should turns ON.
4. The Inclusion process should be completed when the LED turns off.
Note: If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion.
Testing
1. For the Panic Button to control other devices on the Z-Wave for Panic and 10 seconds long pressing for disarm, a Scenes needs to be created. Scenes are user defined elements in controller that determines what actions to take when an event occurs. The Panic Button creates the event to this Scene which then controls other activation devices such as plugs or dimmers, or perhaps set the alarm to Arm or Disarm mode.
2. After binding with the Z-Wave the Gateway after about 2 minutes. Subsequently it will send the data once the button is pressed..
TM
controller, the Panic Button will send data about its battery power to
TM
controller by 2 seconds long pressing
Installation
The Panic Button can be installed on the wall either by using the supplied double-sided tapes or the screws:
1. Using the double-sided tape: first peel one side of the tape and place the sticky side onto the back of the Panic Button. Then peel the other side of the tape and attach the unit onto a proper location on the wall.
2. Using the screws:
i. Detach the rear cover by removing the front cover and then pressing the rear cover latch
(see item in Product Overview).
ii. Use the rear cover as a template to mark on the wall the positions of two screws. The marks
should be in horizontal positions and the distance between the two marks is 60mm.
iii. Drill the holes using an appropriate size drill bit. Insert the supplied plastic wall plugs first for
a cement wall. For a wooden wall the wall plugs would not be needed.
iv. Position the rear cover on the wall and turn the two screws into the wall (or wall plugs). DO
NOT fasten too tightly as the rear cover might be damaged. Then replace the main body
Note: Ensure the unit is installed within transmission range of the gateway using the test above.
and the front cover.
Maintenance
Manufacturer ID
Product Type
Product
ID
0x0060
0x000
A 0x000
2
Event
Length
Program started
0x0C 0x01 null
Program started
Clear 0x0C 0x00 1
byte 0x01
Program completed
0x0C 0x03 null
Program completed
Clear 0x0C 0x00
1 byte
0x03
The power is applied for the
firs
t time
0x08 0x01 null
The battery is Low
0x08 0x0A null
Minimum Wake Up Interval
600s
(10
minutes
)
Maximum Wake Up Interval
86400
s
(1
day)
Default Wake Up Interval
14400
s
(4
hours)
Wake Up Interval Step Seconds
600s (10 mi
nutes)
No node ID
The Z
-
Wave Controller does not allocate a node
2-s
econd on, 2
-
second off
1. Do not put the unit in humid or dusty places or facing direct sunlight.
2. Do not place the unit near combustible substances or any source of heat, e.g. fires, radiators, boilers etc.
3. The suitable ambient temperature for the unit is -10°C - +40°C.
Low Battery: The Panic Button will inform the Gateway when its battery runs low. Also, if the unit has completed binding with a Gateway and the front cover is detached, you can see the LED flashes once when you press the up/down key to indicate low battery condition.
Programming
Z-Wave Group
The unit supports either one of two Z-wave Association Groups:
Group 1: Association with 1 Controller node. Group 2: Association with 4 nodes (i.e. end devices such as smart plugs and other lighting
controllers).This allows the On/Off module to receive commands directly from these end devices without the participation of the controller.
Group 1 commands: When the unit is powered for the first time, the unit will send a Notification Report to the node of Group 1. When device status being changed, the unit will send Notification command to the node of Grouping
1.
Upon device status being changed, the unit will check its battery status simultaneously. When the battery level of the unit drops to an unacceptable level, the unit will emit Notification report to the nodes of Grouping 1. Device Reset: When performing Factory Reset the unit will send Device Reset Locally Notification to the node of Group1.
Group 2 commands:
When device is pressed by Up key, the unit will send BASIC SET command which contains a value that is adjustable, to the nodes of Grouping 2. When device is pressed by Down key, the BASIC_SET command will also be sent to the nodes of Grouping 2.
Role Type Node Type Installer Icon User Icon
Slave Sleeping report
Z-Wave Plus node
Notification Sensor
Version
Protocol Library 3 (Slave_Enhance_232_Library)
Protocol Version 4.6 ( 6.71.00)
Manufacturer
Notification Sensor
Notification
Event Type Event
Parameters
Event Parameters
Battery
Battery Report (value) Description
0x64 Battery is high
0x10 Battery is normal
0x00 Battery is low
Command Classes
COMMAND_CLASS_ZWAVEPLUS_INFO_V2  COMMAND_CLASS_ASSOCIATION_V2 * COMMAND_CLASS_ASSOCIATION_GRP_INFO * COMMAND_CLASS_TRANSPORT_SERVICE_V2  COMMAND_CLASS_VERSION_V2 * COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2* COMMAND_CLASS_DEVICE_RESET_LOCALLY* COMMAND_CLASS_POWERLEVEL_V1* COMMAND_CLASS_BATTERY* COMMAND_CLASS_SECURITY  COMMAND_CLASS_SECURITY_2  COMMAND_CLASS_NOTIFICATION_V8* COMMAND_CLASS_WAKE_UP_V2* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 *
*Items marked an asterisk are secure command classes.
Wakeup Command Class
After it has been included into a Z-wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life.
The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below:
AGI (Association Group Information) Table
Group Profile Command Class & Command (List) N bytes Group Name(UTF-8)
1 General
2 Control Basic Set Basic Set
Notification Report Device Reset Locally Notification
Lifeline
Troubleshooting
The table below lists the several steps involved when adding or removing the detector from the Z-wave network.
Action/Status Description LED indication
Loading...
+ 1 hidden pages