Technical Data Sheet
Infrared Remote-control Receiver Module
IRM-37xxT SERIES
Features
• Photo detector and preamplifier in one package
• Internal filter for PCM frequency
• Improved inner shielding against electrical field disturbance
• TTL and CMOS compatibility
• Low power consumption
• Improved immunity against ambient light
• Suitable burst length 10 cycles/burst≧
• Pb free
• BiCMOS manufacture IC ; ESD HBM>4000V ; MM>250V
• The product itself will remain within RoHS compliant version.
Descriptions
The IRM-37xxT is miniaturized receivers for infrared remote control systems.
PIN diode and preamplifier are assembled on lead frame, the epoxy package is
designed as IR filter. The demodulated output signal can directly be decoded by
a microprocessor.IRM-37xxT is the standard IR remote control receiver
series, supporting all major transmission codes.
Applications
․Light detecting portion of remote control
․AV instruments such as Audio, TV, VCR, CD, MD, etc.
․Home appliances such as Air-conditioner, Fan , etc.
․The other equipments with wireless remote control.
․CATV set top boxes
․Multi-media Equipment
Electro-Optical Characteristics (Ta=25℃, and Vcc=3V)
Parameter SymbolMIN. TYP. MAX.Unit
IRM-37xxT SERIES
Notice
V
℃
℃
℃
4mm from mold body
less than 10 seconds
Condition
Consumption Current Icc
Peak Wavelength
Reception Distance
Half Angle(Horizontal)
Half Angle(Vertical)
High Level Pulse Width TH
Low Level Pulse Width TL
High Level Output Voltage VH
Low Level Output Voltage VL
Notes:
*1:The ray receiving surface at a vertex and relation to the ray axis in the range of θ= 0° and θ=45°.
*2:A range from 30cm to the arrival distance. Average value of 50 pulses.
The specified electro-optical characteristics is satisfied under the following
Conditions at the controllable distance.
cMeasurement place
A place that is nothing of extreme light reflected in the room.
dExternal light
Project the light of ordinary white fluorescent lamps which are not high
Frequency lamps and must be less then 10 Lux at the module surface.
(Ee≦10Lux) eStandard transmitter
A transmitter whose output is so adjusted as to Vo=400mVp-p and the output
Wave form shown in Fig.-1.According to the measurement method shown in
Fig.-2 the standard transmitter is specified.
However , the infrared photodiode to be used for the transmitter should be
λp=940nm,∆λ=50nm. Also, photodiode is used of PD438B(Vr=5V).
(Standard light / Light source temperature 2856°K). fMeasuring system
According to the measuring system shown in Fig.-3