101 Sheffield Road, Welshpool, Western Australia, 6106
SHRIRO AUSTRALIA PTY. LIMITED
23-27 CHAPLIN DRIVE, LANE COVE, NSW 2066
Telephone: 1300 766 066
FOR PEACE OF MIND AND THE HIGHEST LEVEL OF AFTER SALES
SERVICE, REGISTER YOUR PRODUCT ON: www.everdure.com -
(Refer to the Everdure Product Warranty Registration Form on this
manual)
PLEASE READ THESE INSTRUCTIONS CAREFULLY
BEFORE USING YOUR NEW EVERDURE HEATER
IMPORTANT
1
EVB 0480
EVERDURE MODEL LUMINA SERIES II
The Everdure Convection gas space heaters are described as thermostatically controlled, portable, flueless
convection heaters for use with Natural gas.
The heater is supplied with an approved flexible hose.
A label is attached to the rear of the heater stating the type of gas for which it has been manufactured and
adjusted.
GENERAL REQUIREMENTS
The heater shall be installed in accordance with the manufacturer’s instructions, local gas fitting regulations,
uniform building regulations, municipal building codes, the AGA installation code for gas burning
appliances and equipment and any other relevant statutory regulations.
The heater is intended to be installed as a free standing portable heater, its portability being restricted by the
number of gas outlet points being provided.
The heater must NOT
be BUILT IN. Do not install the heater in a bedroom or a bathroom.
Special room ventilation may apply in your particular state. If in doubt, contact your local gas authority.
Locations where strong draughts occur should be avoided as they may cause unsatisfactory operation of the
heater.
The heater should be installed at least 1 metre from flammable materials, e.g. curtains, and to be 200mm
clear of all walls.
The minimum room size for this appliance is 60 m3.
NOTE
This appliance has been fully function tested prior to packaging. The appliance will give off a slight
smell, as it burns off lubricants used in the manufacturing process.
This appliance is not intended for fireplace insert.
No adjustment is required or available to the user.
No installation is required apart from connection to gas and electrical supplies. Please note, if an
extension lead has to be used, only use an approved lead purchased from your local electrical
supplier. The use of extension leads is not recommended.
After unpacking the heater, check for any damage. If any damage is found, please contact your
supplier.
2
DATA LABEL
The Data Label, as shown below, is located on the rear panel of the heater.
EVERDURE CONVECTION HEATER MODEL LUMINA SERIES II
Gas Type N.G.
Nom Gc Mj/Hr 24
Burner Pressure Hi kPa 0.82
Main Burner Injector mm 2.30
Turn down Injector mm 2.0
A.G.A. Cert. No 6789
IMPORTANT INFORMATION
GAS SUPPLY
Your heater is fitted with a flexible hose and bayonet coupling which enables you to connect or disconnect it
from the gas supply.
Note: If your heater has been disconnected for some time, there will be air in the flexible hose. It will
therefore take a little longer to ignite when you first turn it on.
TO CONNECT
Insert the coupling end into the wall socket firmly and rotate the knurled section clockwise to it’s locked
position.
TO DISCONNECT
Apply firm forward pressure to the knurled area, rotate anti clockwise and pull towards you. The hose
should now come away from the wall socket. Gas is automatically isolated when the hose is disconnected.
ELECTRICAL SUPPLY
Your heater is fitted with a power supply lead, which should be connected to a standard domestic socket. If
the supply lead is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
CONTROLS
The controls are located on the top left hand side of the heater. The control buttons are designed to be easy
to read and use for operation. When first connecting the heater to the power supply, or after a power failure,
the reset button requires pressing until the heater beeps. When the ‘ON’ button is pressed, the heater
conducts a self-check before the heater is ignited. Please note, there is a slight delay before the ignition
sequence takes place.
DESCRIPTION OF OPERATION
Your new convection space heater is thermostatically controlled. Operating the heater has been made easy
with an easy to read display and easy press buttons. The heater will modulate between high and low heat
3
settings whilst operating, depending on the heat setting and the temperature of the room.
SLEEP TIMER
The heater can be switched off automatically using the Sleep Timer.
POWER FAILURE
Your Everdure heater will not operate in the event of a power failure. Should the power fail while the
heater is operating, the heater will stop running. When the power is re-established, it will be necessary to
press the reset button before operating the heater.
PROGRAM
The heater can be programmed to switch ON automatically and also to switch OFF. The heater can be
programmed for two separate ON/OFF times. For more details see the program section of this booklet.
SAFETY FEATURES
The heater has many safety features designed for safe operation of the heater. A child lock is fitted to
prevent children from operating the heater. A tilt switch is fitted which will stop the heater operating if it
receives a knock or if it is knocked over. An over-temperature sensor is located on the inside of the heater
and detects if the heater is operating at a temperature which is unsafe for operation. If the unit becomes too
hot due to a blockage or a fan problem, the heater will stop operating and reverts to a reset mode. The unit
is also fitted with an ODS system, which will shut the unit down if oxygen levels are too low in the room
which causes Flame Failure.
FAN MODE
The heater has a fan mode, which enables it to be operated so that it only circulates the room air. This
function is recommended for warmer temperatures when heat is not required.
LEDS
The heater has 4 LED lights on the front of the heater, which indicates how the heater is operating. The
green LED, which is located on the right hand side, indicates that there is power to the heater. The orange
LED next to the green indicates that the heater is on Hi. The red LED next to the orange LED indicates that
the heater is on Low. The Yellow LED indicates that there is a fault with the heater. If the fault light is
displayed, check the screen for further details, and refer to the fault finding section in this booklet.
4
Important Warnings
Do not spray aerosols in the vicinity of the heater while operating.
Keep combustible materials away from heater. See page 2 for details.
Do not sit on or lean against the heater.
Do not place any obstructions in front of the heater. See page 2 for details.
Do not allow children to place items into the louvre section of the heater.
This heater is not intended for use by young children or infirm persons unless they have been adequately
supervised by a responsible person to ensure that they can use the heater safely.
Do not allow children to play unsupervised near the heater whilst the heater is operating.
Do not place any articles onto the heater. This includes clothing (dry or wet) and containers of water, etc.
Do not allow anybody to lay down or sleep in front of the heater, especially near the louvres.
Do not turn off the heater by pulling the plug from the wall or switching off the power at the wall.
Do not connect to an LP gas cylinder located indoors.
Do not operate the heater in a room smaller than 60 m3. See warning label on page 11.
HEATER DIMENSIONS AND FEATURES