Everbilt DP370C, DP550C User Manual

5 (1)

SKU# 1001480251 1001480255

Model# DP370C DP550C

USE AND CARE GUIDE

CONVERTIBLE JET PUMP

Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service

8 a.m. - 6 p.m., EST, Monday-Friday

1-844-241-5521

WWW.HOMEDEPOT.COM

THANK YOU

We appreciate the trust and confidence you have placed in Everbilt through the purchase of this convertible jet pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.

Thank you for choosing Everbilt!

Everbilt DP370C, DP550C User Manual

Table of Contents

Table of Contents..........................................................

2

Shallow Well Installation ..............................................

5

Performance ..................................................................

2

Pressure Switch Assembly Instructions...................

10

Safety Information.........................................................

2

Deep Well Installation.................................................

11

Warranty.........................................................................

3

Troubleshooting..........................................................

17

Pre-Installation ..............................................................

4

 

 

Performance

SKU

HP

 

 

GPH of Water @ Total Discharge Pressure of 40 psi

 

Max. Pressure

0 ft.

10 ft.

 

20 ft.

30 ft.

40 ft.

50 ft.

60 ft.

70 ft.

 

 

 

 

1001480251

3/4

612

486

 

372

360

318

270

210

180

67 psi

 

 

 

 

 

 

 

 

 

 

 

 

1001480255

1

822

696

 

540

444

420

360

306

276

67 psi

 

 

 

 

 

 

 

 

 

 

 

 

Safety Information

DANGER: Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury, and/or death.

DANGER: ALWAYS disconnect the power to the pump before servicing.

DANGER: Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing.

DANGER: Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.

WARNING: Wear safety goggles at all times when working with pumps.

WARNING: This is a dual voltage 115/230 V pump. VOLTAGE SELECTOR INSIDE PRESET TO 230V.

For 115V selection, please open the terminal cover and set the switch to the proper voltage. All wiring should be performed by a qualified electrician.

WARNING: Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords.

WARNING: Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.

WARNING: The pump should be connected to a 230V/115V GFCI outlet protected with a

10 amp (230V)/20 amp(115V) fuse or circuit breaker.

CAUTION: Know the pump and its applications, limitations, and potential hazards.

CAUTION: Secure the pump to a solid base.

CAUTION: Periodically inspect the pump and system components. Disconnect the pump from the power supply before inspecting.

2

Safety Information (continued)

CAUTION: Follow all electrical and safety codes, particularly the Canadian Electrical Code, and local codes and ordinances.

IMPORTANT: The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in.

IMPORTANT: Ensure the electrical power source is adequate for the requirements of the pump.

IMPORTANT: This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems and remedies.

Warranty

The manufacturer warrants the products to be free from defects in materials and workmanship for a period of one year from date of purchase. This warranty applies only to the original consumer purchaser and only to products used in normal use and service. If within one year this product is found upon examination by the manufacturer to be defective in materials or workmanship, the manufacturer’s only obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturer’s discretion, provided that the product has not been damaged through misuse, abuse, accident, modifications, alterations, neglect or mishandling. Your original receipt of purchase is required to determine warranty eligibility.

The purchaser must pay all labor and shipping charges necessary to replace the product covered by this warranty.

This Limited Warranty does not cover products which have been damaged as a result of an accident, misuse, abuse, negligence, alteration, improper installation or maintenance, or failure to operate in accordance with the instructions supplied with the products, or operational failures caused by corrosion, rust, or other foreign materials in the system.

Requests for service under this warranty shall be made by returning the defective product to the manufacturer as soon as possible after the discovery of any alleged defect. The manufacturer will subsequently take corrective action as promptly as reasonably possible.

The manufacturer does not warrant and especially disclaims any warranty, whether express or implied, of fitness for a particular purpose, other than the warranty contained herein. This is the exclusive remedy and any liability for any and all indirect or consequential damages or expenses whatsoever is excluded.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Contact the Customer Service Team at 1-844-241-5521 or visit WWW.HOMEDEPOT.COM.

For warranty registration please go to www.gppumpsus.com

3

WWW.HOMEDEPOT.COM

 

Please contact 1-844-241-5521 for further assistance.

Pre-Installation

APPLICATION

This unit is a convertible jet pump designed for pumping water where the water level is less than 70 ft. deep. If the water level to the pump is deeper than 70 ft., a deep well submersible pump should be selected. A pressure switch pre-set at 30 psi “on”/ 50 psi “off” has been installed on the pump. The pressure switch will automatically turn the pump on and off based on the system pressure.

TOOLS REQUIRED

Flathead

Phillips

 

Screwdriver

Wrench

Screwdriver

Safety goggles

Tape Measure

Thread Tape

PACKAGE CONTENTS

Part

Description

 

Part

Description

A

Pump

 

E

Pressure regulator

B

Venturi tube (J32P-18/#11)

 

F

Pressure tube

 

 

 

 

 

C

Nozzle (#02)

 

G

Pressure gauge

D

O Ring

 

 

 

 

 

 

 

 

SPECIFICATIONS

 

Power supply

115V/230V, 60 HZ., 20/10 Amp Circuit

 

 

Liquid temp. range

32°F to 77°F (0°- 25°C)

 

 

Discharge size

1 in. FNPT

 

 

Suction size

1-1/4 in. FNPT

 

 

Shallow well water level

25 ft.

 

 

Deep well water level

70 ft.

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

Pre-Installation (continued)

DETERMINE THE DEPTH OF YOUR WELL

Tie a small but heavy weight such as a fishing weight to the end of a piece of cotton string. Lower the weight into the well until it reaches the bottom of the well. Make a mark on the string at ground level. Pull the weight out of the well and measure from the bottom of the weight to the ground level mark. This is the depth of your well. Subtract 5 ft. from the depth of your well. If this number is less than 25 ft., shallow well installation should be taken. If this number is more than 25 ft. and less than 70 ft., deep well installation should be taken. If this number is more than 70 ft., a deep well submersible pump should be selected. Measure the ground level mark to the mark where the cotton string is wetted. This number is your well’s water level. It should also be at least 10 ft. below the well’s water level while the pump is running in order to prevent the pump from sucking air due to water level drawdown.

LOCATION OF THE PUMP

Decide on the area for the pump installation. Select a pump location with adequate space for future pump maintenance. It can be located in the basement or utility room of the house, at the well, or between the house and the well. If installed outside of the house, it should be protected by a pump house with auxiliary heat to prevent possible freezing. Protect the pump against flooding and excess moisture. The well also should be protected for sanitary reasons. Mount the pump as close to the well as possible.

TANKS - PRE-CHARGED STORAGE

For best performance of the pump, it is recommended that you use a diaphragm pressure tank (sold separately). It is best to have this in place before installing the pump. A pre-charged storage tank has a flexible bladder or diaphragm that acts as a barrier between the compressed air and water. This barrier prevents the air from being absorbed into the water and allows the water to be acted on by compressed air at initially higher than atmospheric pressures (pre-charged). More usable water is provided than with a conventional type tank.

CAUTION: In order for the pump and tank to operate properly, the pressure tank needs to be drained of all water BEFORE INSTALLING THE NEW PUMP. After draining, if you are using the supplied 30/50 psi pressure switch at the pre-set settings, add or adjust the air pressure in the tank to 28 psi of pressure BEFORE startup.

For wells 25 ft. or less in depth, shallow well installations should be adapted. The shallow well installations have only one single pipe between the pump and well water.

Shallow Well Installation

MATERIALS REQUIRED (NOT INCLUDED)

One can PVC cement & primer (read instructions carefully)

One well seal with vent plug

 

 

One can thread compound (read instructions carefully)

Foot valve

 

 

Thread tape

Priming tee and plug

 

 

Rigid pipe

Relief valve

 

 

Check valve

Adaptor

 

 

Flexible plastic pipe/clamps

Tank

 

 

Tank tee

 

 

 

WARNING: All joints and connections must be AIRTIGHT. A single leak will prevent the proper operation of the pump. Wrap thread tape clockwise on all threaded connections. For all non-threaded connections, you must use PVC Purple Primer and PVC Cement to ensure airtight seals. Measure all pipe lengths before attaching.

NOTE: A foot valve is a check valve that is used to keep the water from running back into the well from the pump and maintain hydraulic pressure when the pump is not running. If the foot valve does not hold the water the pump will lose it's prime and will not pump water. If the foot valve open pressure is too high (the spring is too stiff), or the flow area is too small, the pump suction head and flow rate will significantly drop.

NOTE: The suction pipe size should not be less than 1-1/4 in. The suction size of this pump is 1-1/4 in. FNPT.

5

WWW.HOMEDEPOT.COM

 

Please contact 1-844-241-5521 for further assistance.

Shallow Well Installation (continued)

REPLACING AN EXISTING PUMP

WARNING: Risk of electric shock. Can shock, burn or kill. Disconnect power to pump before working on pump or motor.

1.Drain and remove the old pump. Check the old pipe for scale, lime, rust, etc., and replace it if necessary.

2.Install the pressure gauge in the pump body.

3.Install the pump in the system. Make sure that all pipe joints in the suction pipe are air-tight as well as water tight. If the suction pipe can suck air, the pump will not be able to pull water from the well.

4.Adjust the pump mounting height so that the plumbing connections do not put a strain on the pump body. Support the pipe so that the pump body does not take the weight of piping or fittings.

You have just completed the well plumbing for your new shallow well jet pump. Please go to discharge pipe and tank connections.

6

Loading...
+ 13 hidden pages