Eurotech ReliaGATE 10-20 User Manual

Page 1
ReliaGATE 10
-20
Multi
-Service Gateway and Edge Controller
Revision 1 – October 2014 – 110129-00011
Page 2
© 2014 Eurotech
Trademarks
All trademarks both marked and unmarked appearing in this document are the property of their respective owners.
Revision history
Revision
Description
Date
1
Initial release
October 2014
Page 3
ReliaGATE 10-20 User Manual Table of Contents
3
110129
-00011
Table of Contents
Trademarks .................................................................................................................................................................. 2
Revision history ........................................................................................................................................................... 2
Table of Contents ............................................................................................................................................... 3
Safety and Regulatory ........................................................................................................................................ 4
Overview ......................................................................................................................................................... 11
Block Diagram ............................................................................................................................................................ 12
Features ..................................................................................................................................................................... 13
Product Options......................................................................................................................................................... 14
Related Documents ................................................................................................................................................... 14
Interfaces ........................................................................................................................................................ 15
Power......................................................................................................................................................................... 17
Communications ........................................................................................................................................................ 18
User Interface ............................................................................................................................................................ 22
Discrete I/O................................................................................................................................................................ 24
System Specifications ....................................................................................................................................... 25
Mechanical ................................................................................................................................................................ 25
Power Supply ............................................................................................................................................................. 26
Communication ......................................................................................................................................................... 26
Discrete I/Os .............................................................................................................................................................. 29
Environmental ........................................................................................................................................................... 29
Page 4
Safety and Regulatory ReliaGATE 10-20 User Manual
4
110129-
00011
Safety and Regulatory
Carefully read and understand the instructions in this manual before using this device.
Whenever you have any doubt regarding the operation of this device, consult this manual or contact your local Eurotech Technical Support Team (see the last page of this manual for details).
Keep this manual for future reference.
To lower the risk of personal injury, electric shock, fire or damage to equipment, observe the following precautions, as well as using good technical judgment, whenever installing or using the device.
Eurotech has made every effort to ensure the accuracy of this document; however, Eurotech assumes no liability resulting from any error/omission in this document, or from the use of the information contained herein.
Eurotech reserves the right to revise this document or to make changes to its content at any time without any obligation to notify any person of such revision or changes.
Alerts that can be found throughout this manual
SYMBOL
MEANING
DANGER
Information highlighting potential electrical shock hazards:
Personal injury or death could occur.
Damage to the system, connected peripheral devices, or software could occur.
Always use appropriate safety precautions. Also ensure that the installation meets all the requirements as set out for the environment that the equipment will be deployed in.
WARNING
Information highlighting potential hazards:
Personal injury or death could occur.
Damage to the system, connected peripheral devices, or software could occur.
Always use appropriate safety precautions. Also ensure that the installation meets all the requirements as set out for the environment that the equipment will be deployed in.
NOTE
These will highlight important features or instructions.
Page 5
ReliaGATE 10-20 User Manual Safety and Regulatory
5
110129
-00011
Safety notices and warnings
Observe the following safety precautions during all phases of operation, service, and repair of the device.
Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the device.
Eurotech assumes no liability for the customer’s failure to comply with these requirements.
The safety precautions listed below represent warnings of certain dangers of which Eurotech is aware. You, as the user of the device, should follow these warnings and all other safety precautions necessary for the safe operation of the device in your operating environment.
Do not operate in an explosive atmosphere
WARNING Do not operate the equipment in the presence of flammable gases or fumes. Operation of any electrical equipment in such an environment constitutes a definite safety hazard.
Antistatic precautions
WARNING To avoid ESD (Electro Static Discharge) damage, always use appropriate antistatic precautions when handing any electronic equipment.
Connection to power supply or other devices
DANGER Before applying power to the system, thoroughly review all installation, operation, and safety instructions. Failure to install the system power supply correctly or to follow all operating instructions correctly may create an electrical shock hazard, which can result in personal injury or loss of life, and/or damage to equipment or other property
To avoid injuries, always disconnect power and discharge circuits before touching them.
Only start the device with a power supply that meets the requirements stated on the voltage label. In case of
uncertainties about the required power supply, please contact the Eurotech Technical Support Team or the electricity authority
Before connecting other equipment carefully read any supplied instructions
Always disconnect the power before connecting or disconnecting cables
Do not perform connections with wet hands
Check any power cords for damage before use
Page 6
Safety and Regulatory ReliaGATE 10-20 User Manual
6
110129-
00011
Use certified power cables. The power cable must meet the requirements (voltage and current) of the
device.
Position cables with care. Avoid positioning cables in places where they may be trampled on or compressed
by objects placed on them. Take particular care of the plug, power-point and outlet of power cable
Avoid overcharging any power outlets
Only apply power to the device or connected equipment after checking that all the above conditions have
been met
Installation
WARNING
Verify that the mounting location can withstand the added loads caused by the addition of the device, it
should be firmly secured so that it will not cause any potentially hazardous situations (e.g. falling down due to vibration or shock)
Do not operate the device near heat sources or flames.
NOTE:
If the device must be moved from one place to another with different ambient temperatures, ensure sufficient time for the temperature of the device to stabilize before repowering.
Ventilation
WARNING
Ensure adequate ventilation to avoid overheating, Eurotech suggests the following steps:
When installing the device within a cabinet, rack or other enclosed space, be sure to leave sufficient space
to allow adequate air circulation
Do not block any ventilation openings
Maintenance
DANGER
Never open, dismantle or repair the device.
For your maintenance or repair requirement please contact a qualified Eurotech engineer.
If the device does not function correctly and you are unable to find a solution, feel free to contact the Eurotech Technical Support Team.
Page 7
ReliaGATE 10-20 User Manual Safety and Regulatory
7
110129
-00011
If the equipment does not work properly, especially if smells unusual, unplug it immediately and contact the Eurotech Technical Support Team (see last page of this manual for further details).
Cleaning
WARNING
When cleaning the device, remember to:
Ensure sufficient ESD protection during the cleaning process.
Remove any power from the device.
When cleaning an enclosed system or peripheral use a dry cloth on the external casing.
With single boards, use only a low power air brush or soft bristled paintbrush.
Do not use detergents, aerosol sprays, solvents or abrasive sponges.
Page 8
Safety and Regulatory ReliaGATE 10-20 User Manual
8
110129-
00011
Life support policy
WARNING Users must not use Eurotech products as critical components of life support devices or systems without the express written approval of Eurotech Spa.
Warranty
Please contact your local Eurotech Sales Office for detailed warranty terms and conditions.
Refer to the back covers of this manual for full contact details.
CE notice
This product is CE marked.
The CE mark on the product indicates that it conforms to
the essential requirements of the
applicable EC directives.
Eurotech is not responsible for the
use of its products together with equipment (e.g. power
supplies, personal computers, etc...) that are not CE marked and compliant with technical
requirements specified in this manual.
WEEE
The information below complies with the regulations set out in the 2002/96/EC directive, subsequently superseded by 2003/108/EC. It refers electrical and electronic equipment and the waste management of such products.
When disposing of a device, including all of its components, subassemblies and materials that are an integral part of the product, you should consider the WEEE directive.
The use of the following symbol, attached to the equipment, packaging, instruction literature, or
the guarantee sheet, states that the device has been marketed after August 13th 2005, and implies that you must separate all of its components when possible, and dispose of them in accordance withal waste disposal legislations:
Because of the substances present in the equipment, improper use or disposal of the refuse can cause
damage to human health and the environment.
With reference to WEEE, it is compulsory not to dispose of the equipment with normal urban refuse; an
arrangement for separate collection and disposal is essential.
Page 9
ReliaGATE 10-20 User Manual Safety and Regulatory
9
110129
-00011
To avoid any possible legal implications contact your local waste collection body for full recycling
information.
RoHS
This device, including all the components, subassemblies and the consumable materials that are an integral part of the product, have been manufactured in compliance with the European directive 2002/95/EC known as the RoHS directive (Restrictions of the use of certain Hazardous Substances). This directive targets the reduction of certain hazardous substances previously used in electrical and electronic equipment (EEE).
EMC Requirements for Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference
Causing Equipment Regulations. This device complies with Industry Canada RSS Appliance radio exempt from licensing.
The operation is permitted for the
following two conditions:
1) The device may not cause harmful interference, and
2)
The user of the device must accept any interference suffered, even if the
interference is likely to jeopardize the operation.
FCC Part 15 Class B Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment gener
ates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Technical assistance
For any technical questions, or if you cannot isolate a problem with your device, or for any enquiry about repair and returns policies, feel free to contact your local Eurotech Technical Support Team.
See the back cover for full contact details.
Page 10
Safety and Regulatory ReliaGATE 10-20 User Manual
10
110129-
00011
Transportation
When transporting any module or system, for any reason, it should be packed using anti-static material and placed in a sturdy box with enough packing material to adequately cushion it.
Disclaimer:
This equipment generates and can radiate radio frequency energy and may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by such measures as reorienting the receiving antenna, increasing separation between equipment and receiver, or connecting the equipment into an outlet on a different electrical circuit.
Additional restrictions and requirements may be listed in the System Specifications.
Warning: Any product returned to Eurotech that is damaged due to inappropriate packaging will not be covered by the warranty.
Conventions
The following table describes the conventions for signal names used in this document.
Convention
Explanation
GND
Digital ground plane
#
Active low signal
_P
Positive signal in differential pair
_N
Negative signal in differential pair
The following table describes the abbreviations for direction and electrical characteristics of a signal used in this document.
Type Explanation
I
Signal is an input to the system
O
Signal is an output from the system
IO
Signal may be input or output
P
Power and ground
A
Analog signal
3.3
3.3 V signal level
5
5 V signal level
NC
No Connection
Reserved
Use is reserved to Eurotech
Page 11
ReliaGATE 10-20 User Manual Overview
11
110129
-00011
Overview
The ReliaGATE 10-20 is a ready-to-deploy, industrial-grade, smart device that enables communications, computational power, simplified application deployment, and M2M platform integration for immediate service generation. It provides a flexible communication architecture and offers connectivity to a wide range of sensors and edge devices making it easy to deliver data to your business application. ReliaGATE 10-20 supports wireless applications including GPS, Wi-Fi, 2G/3G cellular, and IEEE 802.15.4/ZigBee
®
Standard and wired connectivity
such as USB 2.0, Gigabit Ethernet, serial ports, CAN, analog inputs, and isolated digital I/O.
With the ReliaGATE 10-20, you can easily manage configuration and deliver out-of-the-box connectivity for your M2M and network applications. Software support includes Eurotech’s Everyware
Software Framework (ESF)
that provides the MQTT plug-in enabling connection to Eurotech’s Everyware
Cloud.
The following figure shows a full-feature ReliaGATE 10-20. A ReliaCELL 10-20 cellular module is mounted. Actual units may vary in appearance depending on the selected options.
ReliaGATE 10-20, with ReliaCELL
Page 12
Overview ReliaGATE 10-20 User Manual
12
110129-
00011
Block Diagram
The following diagram illustrates the organization of the ReliaGATE 10-20.
Some features of the processor are accessible on the motherboard, but are not available externally. See the CPU 351-13 user manual for details.
UART 4
Buf
UART
1
Xcvr
USB 5
USB6
USB7
Gigabit Ethernet 2
Gigabit Ethernet 1
Power
RTC
AUD6
MIPI
CSI-2
2
x3
LEDs
GPIOs
wireless modules
Smart Power
Controller
Reset
Vin
Power Input
IGN
CPU OFF
Alive
USB-
ETH
Audio
CODEC
ReliaGATE 10-20
ReliaCELL 10-20
(USB “3.0")
3.3V
PCIe
USB OTG
LCD
Micro HDMI
HDMI
SIM
GPS (SMA)
UART 5
UART 2
SPI
Bus 3
SD
4
(8-bit
)
SD 2 (4-bit)
Keypad
GPIO
USB
2.0
LVDS
Display 0
DDR3
BAT
7­Port USB
HUB
USB 1
USB 2
USB 3
USB 4
Xcvr
Buf
I2C
eMMC NAND
flash
Power
Manager
Freescale i.MX 6
Processor
x2 USB
USB OTG
Wi-Fi/Bluetooth/
ZigBee (SMA)
microSD
Serial 1
Serial 2
Wi-Fi
GPS
CAN
Bus
CAN I/F
x2 A/D
x4 GPIO
Line Out (R)
Mic (R)
CAN 2.0b
DRAM
Cellular
A/D
Debug
RESET
Serial
5
Serial
4
SATA
Serial 5
Serial 4
Page 13
ReliaGATE 10-20 User Manual Overview
13
110129
-00011
Features
Processor
Freescale iMX6 800MHz Solo Core processor
Memory
512 MB DDR3 DRAM
Up to 64GB on-board flash with soldered down eMMC
MicroSD expansion slot
Communications
Two gigabit Ethernet ports
Three USB 2.0 host ports
One CAN2.0 bus
Wi-Fi IEEE 802.11
GPS receiver
Cellular: Accepts ReliaCELL 10-20 modems
Indicators
Ten LED status indicators
Discrete I/Os
Two analog inputs
Four digital inputs
Software
Everyware™ Software Framework option
Supports Everyware
Device Cloud
Power Supply
Supports 12 VDC vehicle power, transient protection, vehicle ignition input, Low Power Mode
4 W power consumption
Battery-backed real-time clock
Page 14
Overview ReliaGATE 10-20 User Manual
14
110129-
00011
Product Options
In addition to the standard features described in the previous section, the ReliaGATE 10-20 is designed to support the following options:
Amplified audio output
Application-specific ZigBee stack
Built-in cellular module
Customization of Smart Power microcontroller
If your application requires one or more of these options, contact your local Eurotech representative for availability.
Related Documents
This manual describes the ReliaGATE 10-20 at the system level and is intended for installers, software developers, and system integrators. The following documents are also important resources for the ReliaGATE 10-20.
Document
Available at
Denali User Manual
http://support.eurotech-inc.com/forums/topic.asp?topic_id=3040
Everyware Cloud Developer’s Guide
http://everywarecloud.eurotech.com/doc/ECDevGuide
Everyware Software Framework Developer’s Guide
http://esf.eurotech.com/doc/ESFDevGuide
Page 15
Interfaces
This section describes the communications, user interface, discrete I/Os, and power supply features of the ReliaGATE 10-20.
The following images illustrate the location of the interface connectors.
Front Panel, ReliaGATE interfaces exposed
Front Panel, ReliaGATE 10-20 installed
Page 16
Interfaces ReliaGATE 10-20 User Manual
16
110129-
00011
Rear Panel
Page 17
ReliaGATE 10-20 User Manual Interfaces
17
110129
-00011
Power
Power Supply
Connector
4-position, 2-row, 4.2mm shrouded pin header
Molex Mini-FitTM 35318-0420 or 35318-0421
Mating connector
4-position, 2-row, 4.2mm shrouded receptacle housing
Molex Mini-Fit 5557 series, p/n 39-01-2040, etc Crimp receptacle for 18-24 AWG wire, tin plated (4 ea) Molex p/n 39-00-0039 or 39-00-0060
The ReliaGATE 10-20 power connector is a 4-pin header located on the rear panel.
Pin
Name
Type
Description
1
RSVD
reserved
2
VIN
PI
Power input
3
GND P Ground
4
IGN I Ignition sense
See
Power Supply, page 26 for electrical specifications.
IGN RSVD
GND VIN
Page 18
Interfaces ReliaGATE 10-20 User Manual
18
110129-
00011
Communications
ReliaGATE 10-20 offers connectivity to a wide range of wireless protocols including GPS, Wi-Fi (IEEE 802.11), and IEEE 802.15.4/ZigBee
®
. The ReliaGATE 10-20 also includes interfaces for wired connectivity such as USB 2.0,
Gigabit Ethernet, EIA-232/485 serial, and CAN 2.0b.
The ReliaGATE 10-20 provides cellular connectivity via pre-certified ReliaCELL modules, which secure directly to the front panel.
Wi-Fi (IEEE 802.11)
Connector
SMA connector (outside threads) with center receptacle
Mating connector
SMA cable with nut (inside threads) and center pin
The ReliaGATE 10-20 includes a Wi-Fi adapter. Connect an external antenna to the "WIFI" SMA connector for the frequency ranges your application will use (2.4 GHz and/or 5 GHz).
See the System Specifications section for additional details.
GPS
Connector
SMA connector (outside threads) with center receptacle
Mating connector
SMA cable with nut (inside threads) and center pin
The ReliaGATE 10-20 includes a multi-channel GPS receiver for accurate location information worldwide.
Connect an external GPS antenna to the GPS SMA connector to enable GPS functionality. The antenna should support a frequency of 1575.42 MHz (GPS L1). For quick signal acquisition and greatest accuracy, the antenna should be mounted with visibility to a wide area of the sky in order to receive signals from multiple positioning satellites.
See the System Specifications section for additional details.
ReliaCELL Docking Bay: USB/Cellular, SD, SIM, Debug
The docking bay is designed to accept a ReliaCELL cellular module. When installed, the ReliaCELL covers Secure Digital, SIM, OTG, and debug connectors.
ReliaCELL Port
Connector
USB Type A socket
M2.5 threaded mounts (4x)
Mating connector
ReliaCELL 10-20 (USB)
M2.5 x 20 screws (4x) (Eurotech mounting kit 250128-90501)
The ReliaGATE 10-20 includes a docking bay for the ReliaCELL 10-20, a family of cellular modem modules that are certified for networks, technologies, and carriers around the world.
Page 19
ReliaGATE 10-20 User Manual Interfaces
19
110129
-00011
Secure the ReliaCELL 10-20 to the bay on ReliaGATE 10-20 as described in the Mechanical section of this manual. Follow the guidelines in the ReliaCELL user manual for antenna selection.
All Eurotech operating systems are designed to support the ReliaCELL 10-20.
USB OTG
Connector
USB OTG mini Type B socket
Mating connector
USB OTG cable, mini Type B plug
This socket supports a USB On-the-Go connection. This socket can be used to restore unit with corrupted software. Contact factory for current level of software support.
MicroSD
Connector
microSD socket, push-push type
Mating connector
microSD storage card
Use a microSD card into the "SD" socket to expand storage capacity of the ReliaCELL 10-20.
Insert the card until it clicks into place. Press on the card again to eject it.
SIM
Connector
SIM socket, push-push type
Mating connector
SIM card from a cellular service provider
If your model of the ReliaCELL 10-20 includes an on-board cellular modem, you may need to insert a SIM card from your cellular service provider into this slot. Insert the SIM until it clicks into the socket. Press on the SIM a second time to eject it.
If you are using a ReliaCELL cellular modem, any required SIM should be installed in the ReliaCELL enclosure, and not in this slot.
Debug
Connector
Three-pin, 0.1 inch pin header
Mating connector
None
The debug connector provides two signals that can be used during product development. Pin 1 located closest to the center-line of the front panel, pin 3 is toward the corner. Used for unit recovery if software becomes corrupted.
Pin
Signal
Description
1
Reset#
Short to ground to reset the system.
2
GND
Ground
3
SD2_Boot
Shunt to ground to boot from SD.
Page 20
Interfaces ReliaGATE 10-20 User Manual
20
110129-
00011
USB
Connector
USB Type A socket
Mating connector
USB Type A plug
The ReliaGATE 10-20 provides two USB 2.0 host ports on the rear panel.
A third USB 2.0 port is designed for use with ReliaCELL 10-20. The connector is located in the ReliaCELL 10-20 bay and employs a USB 3.0 Type A socket to bring out additional signals for use by the ReliaCELL. This socket will work with standard USB 2.0 devices, if an additional port is needed for an application.
Both ports support higher-current peripherals. See the System Specifications for details.
Ethernet
Connector
RJ-45 socket, with chassis-grounded shell
Mating connector
RJ-45 plug, shielded cable optional and supported
The ReliaGATE 10-20 provides two RJ-45, gigabit Ethernet ports on the rear panel.
The left Ethernet port is referenced as Ethernet 1 and is directly connected to the processor. The right Ethernet port is referenced as Ethernet 2 and is driven by a USB 2.0 port. The MAC address for each port is provided on the label that is located on the bottom of the enclosure.
See the System Specifications section for additional details.
Vehicle – CAN 2.0b
The ReliaGATE 10-20 provides a CAN 2.0b (Controller Area Network) bus on the Discrete I/O connector. CAN bus is typically found in vehicles and industrial automation equipment.
See the System Specifications section for additional details.
Page 21
ReliaGATE 10-20 User Manual Interfaces
21
110129
-00011
Serial 1
Connector
DB-9 M header
Mating connector
DB-9 F cable
This connector provides access to two serial ports. Connect a standard EIA-232 cable to access three-wire port Serial 1. Use a customized cable or wiring pinout to access Serial 5.
The transceivers for both ports can be disabled through software.
Pin
EIA-232 Signal
Type
2
RXD1
I
3
TXD1
O 5 GND
P
7
NC
8
NC
1
RDX5
I
4
TXD5
O 6 NC
9
NC
Serial 2
Connector
DB-9 M header
Mating connector
DB-9 F cable
This connector provides access to two serial ports. Connect a standard EIA-232 cable to access four-wire port Serial 2. Use a customized cable or wiring pinout to access Serial 1 (COM4?).
Serial 2 can be software selected to use single-ended EIA-232 or differential EIA-485 signalling. The power-up default is EIA-232.
The transceivers for both ports can be disabled through software.
Pin
EIA-232 Signal
Type
EIA-485 Signal
Type
2
RXD2 I RX2-
I 3 TXD2 O TX2-
O 5 GND P GND
P 7 RTS2 O TX2+
O 8 CTS2 I RX2+
I 1
RDX4 4
TXD4 6
CTS4 9
RTS4
Page 22
Interfaces ReliaGATE 10-20 User Manual
22
110129-
00011
User Interface
The ReliaGATE 10-20 includes LEDs, GPIOs, audio I/O, and A/D inputs to complete the user interface.
LED Indicators
Ten light-emitting diodes (LEDs) on the rear panel indicate the status of ReliaGATE 10-20 subsystems.
LED Group 1: WIFI, CELL, PWR
Group 1 LEDs lie next to the power input and are organized as follows:
LED label
Color
Description
WIFI
red
Wi-Fi Power/Activity
CELL
yellow
On Board Cellular
PWR
green
Controllable by the operating system. Can
indicate system status.
LED Group 2: ZIG, GPS, BT
Group 2 LEDs lie next to the DB9 serial connectors and are organized as follows:
LED label
Color
Description
GPS
yellow
GPS
Ethernet 1 LEDs
The two LEDs on the Ethernet 1 socket illuminate as follows. Illumination indicates connection speed; blinking indicates activity.
Speed
Left
Right
No Link
OFF
OFF
10 Mbps
ON/blink
ON/blink
100 Mbps
ON/blink
OFF
1000 Mbps
OFF
ON/blink
Ethernet 2 LEDs
The two LEDs on the Ethernet 2 socket illuminate as follows. Illumination indicates connection speed; blinking indicates activity.
Page 23
ReliaGATE 10-20 User Manual Interfaces
23
110129
-00011
Speed
Left
Right
No Link
OFF
OFF
10 Mbps
ON/blink
OFF
100 Mbps
OFF
ON/blink
1000 Mbps
ON/blink
ON/blink
HDMI Display
Connector
Micro-HDMI socket
Mating connector
Micro-HDMI cable assembly
The ReliaGATE 10-20 includes an HDMI display output. This output requires licensing for use in commercial applications and is unlabelled on the enclosure. Contact Eurotech Sales if your application requires this feature.
Page 24
Interfaces ReliaGATE 10-20 User Manual
24
110129-
00011
Discrete I/O
Connector
12-position base strip, 3.5mm, green
Phoenix contact 1843897
Mating connector
12-position pluggable terminal block, 3.5mm, with screw
connector Phoenix Contact 1847220 (other orientations available)
A 12-position socket ("base strip") located on the rear panel provides access to analog inputs, general-purpose digital inputs, audio I/O, and the CAN bus. The following figure shows the layout of the base strip.
Screw the mating wires into the pluggable terminal block, plug the terminal block into the base strip, and secure the terminal block to the base strip with the captive screws.
The following table defines the signals on the base strip. See the Specifications section for further details.
Signal Name
Type
Description
A1
I
Analog input 1
A2
I
Analog input 2
GND
P
Ground
D1
I
Digital input 1
D2
I
Digital input 2
D3
I
Digital input 3
D4
I
Digital input 4
GND
P
Ground
MIC
AI
Audio: Microphone input (right channel)
SPKR
AO
Audio: Line output (right channel)
CANH
IO
CAN+
CANL
IO
CAN-
Page 25
System Specifications
Mechanical
The ReliaGATE 10-20 electronics are housed in a sturdy aluminium enclosure consisting of a base plate with mounting tabs and lid. This section provides mechanical details about the enclosure.
Mechanical Drawings
The following mechanical drawings specify the dimensions of the ReliaGATE 10-20 enclosure. Dimensions are in inches [millimeters].
Mechanical Drawing, Top View
Page 26
System Specifications ReliaGATE 10-20 User Manual
26
110129-
00011
Mechanical Drawing, Front Panel
Mounting a ReliaCELL Modem
The ReliaGATE 10-20 includes a bay for mounting the ReliaCELL family of pre-certified cellular modules. Secure it to the front panel using M2.5 screws. Do not over tighten.
Power Supply
Supply Voltage (VIN) 40 V absolute maximum
Symbol
Parameter
Min
Typ.
Max
Units
DC Power Input (VIN)
VIN
Supply voltage, regulated power
7
12 to 24
37
V
V
RTC
RTC backup battery (note 2)
2.8
3
V
Notes:
1. The enclosure on early ReliaGATE 10-20 models indicates a lower limit on the input voltage. While the unit
might run at that voltage, it typically will not start at that voltage.
2. When system power is disconnected, the RTC is battery is powered by a 3V lithium BR1225 coin cell inside
the enclosure.
Communication
Wi-Fi
Feature
Description
IEEE WLAN Standard
IEEE 802.11 a/b/g/n
Access Point and Client
Security
Authentication: Authentication Protocols: Encryption:
WPA and WPA2, 802.1X, EAP-SIM, EAP-AKA PAP, CHAP, TLS, GTC, MS-CHAP, MS-CHAPv2 64-bit and 128-bit WEP, AES-CCMP, TKIP
Page 27
ReliaGATE 10-20 User Manual System Specifications
27
110129
-00011
USB
The ReliaGATE 10-20 includes a seven-port USB hub that controls internal peripherals and provides three ports for external use. The external ports are designed to support higher-current devices.
Loading 3 usb ports at max capacity could be an issue the extended capability is to provide transient load support, 5V regulator maxes out at 3A.
Symbol
Parameter
Min
Typ.
Max
Units
VCC
Output voltage
5 V I
OUT
Output current
1000
mA
Ethernet
Feature
Description
Network Standard
IEEE 802.3/802.3u/802.3ab
Speeds
10/100/1000 Mbps (note 3)
Supports
Auto-negotiation
Auto MDI-X
Note:
3. Ethernet 2 is implemented by a high-speed USB 2.0 to 10/1000/1000 Ethernet Controller. Speeds may be
limited by the USB 2.0 host interface.
Page 28
System Specifications ReliaGATE 10-20 User Manual
28
110129-
00011
GPS
The ReliaGATE 10-20 utilizes a u-blox NEO-6M receiver for GPS functionality.
Parameter
Description
Receiver Type
Channels: Frequency: SBAS:
50 GPS L1, C/A Code WAAS, EGNOS, MSAS
Time-To-First-Fix (all satellites at -130 dBm)
Cold Start (without aiding): Warm Start (without aiding): Hot Start (without aiding): Aided Starts: (dependent on aiding data connection speed and latency)
27 s 27 s 1 s <3 s
Sensitivity (demonstrated with a good active antenna)
Tracking & Navigation: Reacquisition: (for an outage duration 10 s) Cold Start (without aiding): Hot Start:
-161 dBm
-160 dBm
-147 dBm
-156 dBm
Navigation
Update rate:
Up to 5 Hz
Horizontal position accuracy
(CEP, 50%, 24 hours static, -130dBm, SEP: <3.5m)
GPS: SBAS
2.5 m
2.0 m
Configurable Timepulse
Frequency range:
f = 0.25 … 1000 Hz
Accuracy for Timepulse signal
RMS: 99%: Granularity: Compensated:
30 ns <60 ns 21 ns 15 ns
Accuracy
(CEP, 50%, 24 hours static, -130dBm, SEP: <3.5m)
Velocity: Heading:
0.1 m/s
0.5 degrees
Page 29
ReliaGATE 10-20 User Manual System Specifications
29
110129
-00011
Discrete I/Os
The discrete I/Os are designed to meet the following specifications.
Symbol
Parameter
Min
Typ.
Max
Units
Analog Inputs (A1-A2)
VIN
Analog input voltage
0 30
V
f
CONV
Conversion rate (note 5)
5.56 22.2
ksps
A/D sample resolution
8
bit
tRC
low-pass filter time constant (note 6)
2.5 s
IGN
VIN
Input voltage
0 13
V
Digital Inputs (D1-D4) (note 7)
VIH
High-level input voltage
VCC = 5 V
2 VCC V
VIL
Low-level input voltage
VCC = 5 V
0
0.8
V
Notes:
4. Conversion rate is dependent on I
2
C clock rates.
5. Contact your Eurotech sales representative if the analog input in your application requires a faster
response time.
6. Digital inputs and outputs are digitally isolated. Stuffing option for 3.3 VCC, non-isolated I/O is available.
Environmental
The ReliaGATE 10-20 is designed to meet the following environmental specifications.
Parameter
Specification
Operating temperature Industrial
-40°C to +85°C (local ambient)
Relative humidity, non-condensing Up to 95% @ +45°C
Compliance
CE
FCC, IC, 60950-1 MIL-STD-810, version F
Page 30
EUROPE
ITALY
EUROTECH
Tel
: +39 0433.485.411
Fax
: +39 0433.485.499
E
-mail: sales.it@e urotech.com
E
-mail: support.it@eurotech.com
Web:
www.eurotec h.com
UNITED KINGDOM
EUROTECH
Tel:
+44 (0) 1223.403410
Fax
: +44 (0) 1223.410457
E
-mail: sales.uk@eurotech.com
AMERICAS
USA
EUROTECH
Toll free
: +1 888.941.2224
Tel
: +1 301.490.4007
Fax
: +1 301.490.4582
E
-mail: sales.us@eurotech.com
E
-mail: support.us@eurotech.c om
Web:
www.eurotec h-inc.com
ASIA
JAPAN
ADVANET
Tel:
+81 86.245.2861
Fax
: +81 86.245.2860
E
-mail: sales@advanet.jp
E
-mail: tsupport@advanet.jp
Web:
www.advanet.jp
INDIA
EUROTECH
Tel:
+91 80.43.35.71.17
E
-mail: sales.in@eurotech.com
E
-mail: support.in@eurotech.c om
WORLD SUPPORT
HEADQUARTERS
EUROTECH
Via Fratelli Solari, 3/a
For your local contact please refer to: www.eurotech.com/contacts
Specifications and features are subject to change without notice. All trademarks and trade names are the property of their respective owners.
Loading...