See Eurotech Worldwide Presence (on the back cover) for full contact details.
Page 3
Table of Contents
Table of contents
Important user information............................................................................................................................. 4
Safety notices and warnings .......................................................................................................................... 4
Life support policy .......................................................................................................................................... 5
CE notice........................................................................................................................................................ 5
ISIS ICE end panels ......................................................................................................................................... 9
ISIS ICE power supply................................................................................................................................... 11
In order to lower the risk of personal injury, electric shock, fire or equipment damage, users must
observe the following precautions as well as good technical judgment, whenever this product is
installed or used.
All reasonable efforts have been made to ensure the accuracy of this document; however, Eurotech
assumes no liability resulting from any error/omission in this document, or from the use of the
information contained herein.
Eurotech reserves the right to revise this document and to change its contents at any time without
obligation to notify any person of such revision or changes.
Safety notices and warnings
The following general safety precautions must be observed during all phases of operation, service, and
repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere
in this manual violates safety standards of design, manufacture, and intended use of the equipment.
Eurotech assumes no liability for the customer’s failure to comply with these requirements.
The safety precautions listed below represent warnings of certain dangers of which Eurotech is aware
of. You, as the user of the product, should follow these warnings and all other safety precautions
necessary for the safe operation of the equipment in your operating environment.
Installation in cupboards and safes
In the event that the product is placed within a cupboard or safe, together with other heat generating
equipment, ensure proper ventilation.
Do not operate in an explosive atmosphere
Do not operate the equipment in the presence of flammable gases or fumes. Operation of any
electrical equipment in such an environment constitutes a definite safety hazard.
Alerts that can be found throughout this manual
The following alerts are used within this manual and indicate potentially dangerous situations:
Danger, electrical shock hazard:
Information regarding potential electrical shock hazards:
Personal injury or death could occur. Also damage to the system, connected peripheral devices, or
software could occur if the warnings are not carefully followed.
Appropriate safety precautions should always be used, these should meet the requirements set out
for the environment that the equipment will be deployed in.
Warning:
Information regarding potential hazards:
Personal injury or death could occur. Also damage to the system, connected peripheral devices, or
software could occur if the warnings are not carefully followed.
Appropriate safety precautions should always be used, these should meet the requirements set out
for the environment that the equipment will be deployed in.
4
Information and/or Notes:
These will highlight important features or instructions that should be observed.
ETH_ISIS_ICE_USM
Page 5
Important user information
Use an appropriate power supply
Only start the product with a power supply that conforms to the voltage requirements as displayed on
the voltage label attached to the system. In case of uncertainty about the required power supply,
please contact your local Eurotech Technical Support Team (see page 6
Use power supplies that are compliant with SELV regulation.
Use certified power cables. The power cable must fit the product, the voltage and the required current.
Position cable with care, Avoid positioning cables in places where they may be trampled on or
compressed by objects placed on it. Take particular care of the plug, power-point and outlet of power
cable.
Avoid overcharging power-points.
) or the electricity authority.
Antistatic precautions
To avoid damage caused by ESD (Electro Static Discharge), always use appropriate antistatic
precautions when handing any electronic equipment.
Life support policy
Eurotech products are not authorized for use as critical components in life support devices or systems
without the express written approval of Eurotech.
CE notice
The product described in this manual is marked with the label in accordance with the 1999/5/EC
regulation.
Eurotech shall not be liable for use of its products with equipment (i.e. power supplies, personal
computers, etc.) that are not CE marked.
WEEE
The information below is issued in compliance with the regulations as set out in the 2002/96/EC
directive, subsequently superseded by 2003/108/EC. It refers electrical and electronic equipment and
the waste management of such products.
When disposing of a device, including all of its components, subassemblies and materials that are an
integral part of the product, you should consider the WEEE directive.
The symbol to the right has been attached to the equipment or, if this has not been
possible, on the packaging, instruction literature and/or the guarantee sheet. By using this
symbol, it states that the device has been marketed after August 13th 2005, and implies
that you must separate all of its components when possible, and dispose of them in
accordance with local waste disposal legislations.
Because of the substances present in the equipment, improper use or disposal of the refuse can cause
damage to human health and to the environment.
With reference to WEEE, it is compulsory not dispose of the equipment with normal urban refuse,
arrangements should be instigated for separate collection and disposal.
Contact your local waste collection body for more detailed recycling information.
In case of illicit disposal, sanctions will be levied on transgressors.
5
Page 6
ISIS ICE - user manual
RoHS
This device, including all it components, subassemblies and the consumable materials that are an
integral part of the product, has been manufactured in compliance with the European directive
2002/95/EC known as the RoHS directive (Restrictions on the use of certain Hazardous Substances).
This directive targets the reduction of certain hazardous substances previously used in electrical and
electronic equipment (EEE).
Technical assistance
For any technical questions, or if you cannot isolate a problem with your device, or for any enquiry
about repair and returns policies, feel free to contact your local Eurotech Technical Support Team.
See Eurotech Worldwide Presence (the back cover) for full contact details.
Transportation
When transporting any module or system, for any reason, it should be packed using anti-static material
and placed in a sturdy box with enough packing material to adequately cushion it.
Any product returned to Eurotech that is damaged due to inappropriate packaging will not be covered by the
warranty!
Device labelling
The ISIS ICE serial label is affixed to the end panel of the enclosure this contains the Eurotech part
number which in turn contains information on the version and issue of this product the label also
contains a serial number which is unique to each individual ISIS ICE.
The labels will also display product conformity marking.
6
ETH_ISIS_ICE_USM
Page 7
Product overview
Product overview
The ISIS Industrial Compact Enclosure (ICE) encloses a special build version of the ISIS Single Board
Computer (SBC). The ISIS has been modified so that it can plug directly into the ISIS ICE interface
PCB thereby transferring essential interconnection signals such as USB, Ethernet, RS232 and power
to the front panel connectors. The ISIS ICE also protects the ISIS, and provides a CE-compliant
product for use straight out of the box.
The ISIS ICE consists of two extruded ‘U’ shaped sections fitted together and held in place by end
panels. The end panels are fitted with PC style breakout connectors.
Up to three TNC style RF connectors can be added to provide breakouts for the optional GPS, GPRS,
and WiFi modules.
The GPS requirement must be specified when ordering as this is not an aftermarket option.
For all detailed information on the setting up and use of the ISIS please refer to the ISIS Single Board
Computer user manual available on the Eurotech website: www.eurotech.com
The ISIS ICE is available fitted with an optional hard disc drive. This option is also available as an after
market accessory available from Eurotech.
.
Variants
The ISIS ICE is available in three sizes according to the size of the extruded ‘U’ section. The three
sizes available are High-High (as above), High-Low and Low-Low:
The High-High option includes the ISIS ICE LINUX High/High variant and the ISIS ICE XPe
High/High variant. These variants offer the largest available I/O expansion with the addition of
up to two PC/104 I/O cards. Space for a third PC/104 card is available. For details on how to
add the third PC/104 card please contact Eurotech sales.
The High-Low option includes the ISIS ICE LINUX High/Low variant and the ISIS ICE XPe
High/Low variant which allow for one additional PC/104 I/O card to be fitted.
Low-Low option includes the ISIS ICE LINUX Low/Low variant and the ISIS ICE XPe Low/Low
variant which have no I/O expansion available but are much more compact.
7
Page 8
ISIS ICE - user manual
Interface PCB
All variants of the ISIS ICE contain the main ISIS ICE interface PCB. The ISIS plugs directly into the
ISIS ICE interface PCB which acts as the main PC interface to the PC/104 stack. Any expansion
boards that are required in the system plug into the PC/104 stack connectors. The PCB contains a
PSU module, a Mini PCI socket, a SIMM card socket, a memory backup battery and the breakout
connectors for the VGA, USB and Ethernet. Two RS232 connectors are routed out to the front
connector panel.
Mini PCI modules
The GPRS and Wi-Fi options can be made available by the addition of a Mini PCI express module.
The GPRS Mini PCI Express module should be fitted to the ISIS ICE interface PCB where the site for
the SIMM card is situated. The Wi-Fi Mini PCI Express module should be fitted directly to the ISIS.
Please refer to the ISIS Single Board Computer user manual available on the Eurotech website:
www.eurotech.com
This product was tested with the following Mini PCI card products:
GPRS, Sierra Wireless MC 8790
Wi-Fi, Gigabit modelGW-WS50G-RH
.
PC/104 expansion
A comprehensive range of PC/104 I/O cards are available from Eurotech. These are fitted to the
PC/104 stack. Many Eurotech PC/104 I/O cards are available with interconnect breakout cables which
fit directly into to the 25 way ‘D’ positions provided on the ISIS ICE for this purpose.
8
ETH_ISIS_ICE_USM
Page 9
ISIS ICE end panels
ISIS ICE end panels
The pictures below show the positions of the connectors on all three ISIS ICE variants. Connector
designations are clearly marked. The RF connectors shown are normally blanked off because GPS,
Wi-Fi and GPRS are optional. The PC section is common to all three variants.
The rear panel of the ISIS ICE variants differs due to the amount of I/O breakout that is available with each.
All I/O positions are normally fitted with blanking covers, as in the High-Low variant shown on the next page.
ISIS ICE High-High variant
Front view
Rear view
The I/O connectors
shown here are optional
positions, available in
addition to those on the
rear panel.
Optional positions for O/I
connectors are available
for use depending upon
cable runs.
9
Page 10
ISIS ICE - user manual
ISIS ICE High-Low variant
Front view
Rear view
ISIS ICE Low-Low variant
Front view
Rear view
I/O is not available on
this variant.
10
ETH_ISIS_ICE_USM
Page 11
ISIS ICE power supply
ISIS ICE power supply
The ISIS ICE runs from a DC power-supply in the range 9-36V DC, taking a maximum of 5.5A at the
lower DC voltage. The unit is over voltage protected and will shut down if the protection current is
exceeded.
The required power connector for this product is provided with the ISIS ICE and is available as a spare
part from Eurotech.
The connector is Switchcraft part number S760K (www.switchcraft.com
It is essential that the wires are soldered onto the tabs on the connector. The front panel indicates the
polarity:
The positive conductor is soldered to the tab that is connected to the centre pin.
The negative conductor is soldered to the tab connected to the outer barrel.
):
11
Page 12
ISIS ICE - user manual
Connectors
RS232 connectors COM1 and COM2
Pin Signal name Pin Signal name
1 Data Carrier
Detect (DCD)
2 Receive Data
(RX)
1
5
3 Transmit Data
(TX)
5 Ground 6 Data Set ready
7 Request To
Send (RTS)
9 Ring Indicator
(RI)
VGA CRT connector
Pin Signal name Pin Signal name
1 Red 2 Green
3 Blue 4 No Connect
5 Ground 6 Ground
7 Ground 8 Ground
9 +5V (Fused) 10 Ground
4 Data Terminal
Ready (DTR)
(DSR)
8 Clear To Send
(CTS)
9 6
5
10 6
15
1
11
12
11 No Connect 12 DDCSDA
13 HSYNC 14 VSYNC
15 DDCSCL
ETH_ISIS_ICE_USM
Page 13
LAN (Ethernet)
RJ-45 10/100Mb/s.
Pin Signal name
1 TX+
2 TX-
3 RX+
4 No Connect
5 No Connect
6 RX-
7 No Connect
Connectors
8 No Connect
USB connectors
Two USB type A dual stacked connectors.
Pin Signal name Pin Signal name
1 VBUS1 1' VBUS2
2 D1- 2' D2-
3 D1+ 3' D2+
4 GND 4' GND
13
Page 14
ISIS ICE - user manual
Adding GPRS, Wi-Fi and PC104 I/O
To add the optional Wi-Fi, GPRS and PC/104 I/O modules, access to the inside of the enclosure is
required. The following describes how to dismantle the ISIS ICE in order to gain access to the
connection points for these options.
Tools required:
2mm and 2.5mm hexagon key/Allen keys (size measured across the flats).
A Pozidrive screwdriver suitable for M3 Pozidrive screws.
A medium sized flat bladed screwdriver.
Observe antistatic precautions when dismantling the ISIS ICE and when handling the ISIS.
To access the ISIS ICE board assembly, follow these steps:
1. Remove the four bottom M4 dome head hexagon drive fixing screws, two on the front cover and
two on the back cover.
2. Carefully remove the extrusion. (If a hard disk drive has previously been fitted it is recommended
that the complete rear cover is removed before attempting to remove the bottom extrusion.)
This gives complete access to the underside of the ISIS ICE interface PCB:
3. Remove the four remaining M4 fixing screws on the front and rear plate.
14
ETH_ISIS_ICE_USM
Page 15
Adding GPRS, Wi-Fi and PC104 I/O
4. Remove the four outermost front and rear M3 Pozidrive screws holding the board in place:
Pozidrive
screws
5. Place a medium sized flat bladed screwdriver into the space between the ISIS heatsink and the top
extrusion and twist to free the heat pad from the extrusion:
6. Remove the ISIS board assembly:
The assembly is still attached to the front panel and should not be dismantled further. Access to all
serviceable parts is now available. It should not be necessary to further dismantle the ISIS ICE.
Flat bladed
screwdriver
15
Page 16
ISIS ICE - user manual
)
Adding the optional hard disc drive
Observe antistatic precautions when dismantling the ISIS ICE and handling the Hard Disc Drive.
To add the optional hard disk drive, follow these steps:
1. Remove the bottom extrusion and rear panel as described in steps 1-4 of Adding GPRS, Wi-Fi and
PC104 I/O
, page 14. (You do not need to totally dismantle the enclosure).
2. Fit the hard disk drive to the hard disk drive mounting plate using the four screws and nuts
supplied. Do not tighten the nuts, they should be quite loose.
M3 screws and nuts
Hard disk drive bracket
Before proceeding, check that the orientation of the hard disk drive is correct when the two halves of the
extrusion are fitted together. You can do this by trying out the positions before sliding the hard disk drive
into place.
3. Fit the nuts into the grooves on the extrusion:
Grooves (present
on both sides
16
ETH_ISIS_ICE_USM
Page 17
4. Slide the hard disk drive assembly onto the base:
The hard disk drive assembly position can be adjusted to suit alignment.
Adding the optional hard disc drive
5. Fit the IDE cable pin to pin, so that when the enclosures are joined the cable is not twisted:
6. Close the two halves together and re-fit the end panel to complete:
17
Page 18
ISIS ICE - user manual
ISIS ICE dimensional drawings
This section provides dimensional drawings with mounting detail for all three ISIS ICE variants.
The ISIS ICE is fitted with four M4 threaded nuts. These nuts slide into the grooves in the underside of the
enclosures. The measurement Mounting Centres shown below (105mm) is the distance between the centres
of the M4 mounting nuts.
ISIS ICE High-High variant
Mounting Centres
Fitted with 2 off high profile extrusions
18
ETH_ISIS_ICE_USM
Page 19
ISIS ICE High-Low variant
ISIS ICE dimensional drawings
Fitted with 1 off low profile extrusion and 1off
high profile extrusion
Mounting Centres
19
Page 20
ISIS ICE - user manual
ISIS ICE Low-Low variant
Fitted with 2 off low profile extrusions
Mounting Centres
20
ETH_ISIS_ICE_USM
Page 21
Appendix A – ISIS ICE EMC and R&TTE compliance
Appendix A – ISIS ICE EMC and R&TTE compliance
The European Directive 89/336/EEC on Electro-Magnetic Compatibility (EMC) requires that generated
electro-magnetic disturbance must be in accordance with European Harmonised Standards for
Electro-Magnetic Emissions and Immunity.
The ISIS ICE has been independently tested and found to meet the following standards for Light
industrial and Information technology equipment & railways standards as described below for specific
applications where electrostatic discharge may exceed those stated below such as trackside
applications please contact Eurotech technical support for further information and advice.
Emissions EN 50122
Immunity: EN 55024
Specific emissions and immunity standards
Specifically, the Catalyst EC ICE meets the following standards:
Radiated immunity: EN 6100-4-3:2006
(10V/m 1400MHz-2100MHz 80% 1kHz AM)
Conducted immunity: EN 6100-4-6:1996
(11kHz 80% AM 150kHz-80MHz 10V RMS signal and DC power)
Fast transients 2KV: EN 6100-4-4:1995
Electrostatic discharge: EN 6100-4-2: 1995
4KV on contact and 8KV across an air gap
The ISIS ICE is designed to carry Radio transmitting equipment such as the Wi-Fi and GPRS and has
been tested to meet the R&TTE requirements for equipment fitted with intentional radiators.