Eurocave INOA 50, INOA 25 User Manual

Page 1
Operating and installation instructions - INOA cellar conditioners
March 2009
1
Page 2
CONTENTS
WELCOME TO THE WORLD OF EUROCAVE
1 • CONDITIONER DESCRIPTION
3 • ELECTRICAL POWER SUPPLY
4 • CARE FOR THE ENVIRONMENT AND ENERGY SAVING
5 • TECHNICAL SPECIFICATIONS
6 • CELLAR INSULATION
7 • INSTALLING YOUR CONDITIONER
I- General points
II- Drilling the wall
III- Fitting
IV- Discharging condensate
8 • CONDITIONER OPERATION
9 • INSTALLING THE REMOTE CONTROL
I- Remote control description
II- Installing the remote control inside the cellar
III- Installing the remote control outside the cellar
10 • COMMISSIONING YOUR CONDITIONER
I- Connection
II- Switching on
III- Remote control description
IV- Installing the remote control
V- Setting the temperature
VI- Silent function
VII- “Heating” function
VIII- Changing the remote control batteries
IX- Discharging condensate
11 • MAINTENANCE
12 • OPERATING FAULTS
2
Venting plate and wall mounting bracket dimensions
p.18
p.15
p.15
p.15
p.16
p.18
p.18
p.18
p.19
p.19
p.20
p.20
p.20
p.20
p.21
p.21
p.7
p.8
p.9
p.9
p.10
p.10
p.11
p.13
p.14
p.6
p.6
p.4
p.5
p.6
Page 3
Des solutions adaptées à tous vos besoins - Solutions to meet all your needs
All Ihren Bedürfnissen angepaßte Lösungen - Soluciones adaptadas a todas sus necesidades
ARMO IRES À VINS - W INE C ABIN ETS
W EINK LIMASCHRÄNKE - ARMARIO S PARA VINO S
SYSTÈMES DE RANGEMENT - STO RAG E SYSTEMS
REGALSYSTEME - SISTEMAS DE C OLO CAC IÓN
CLIMATISEURS DE C AVE
CELLAR C ONDITIO NERS
W EINK ELLERKLIMAG ERÄTE
CLIMATIZADO RES PARA BO DEGA
SERVICE D U VIN AU VERRE
SYSTEM TO SERVE W IN ES BY THE GLASS
O FFENAUSSC HANKSYSTEM
DISPENSADO R D E VIN O PO R C OPA
O rigine Classic Compact
Cuir - Leather - Leder - Cuero Meuble à Vins Elite
Modulothèque Modulocube Modulorack
Inoa* Vin au Verre*
Sommelier
* Produit non disponible dans cer tains pays. Product not available in certain countries.
3
Page 4
O ur greatest wish is to accompany your enthusiasm for wine throughout the years… To do so, EuroCave puts all of its know-how into action to bring together the essential factors in optimal wine maturing:
Temperature:
The two worst enemies of your wine are extreme temperatures and sudden uctuations in temperature. A constant temperature of 10° to 14°C (50 to 57°F) is considered to be ideal for your wine to reach its full potential. O wing to its electronic regulation system, your EuroC ave IN O A conditioner is activated as soo
n as the cellar temperature rises one degree above the programmed temperature. Furthermore, the presence of a heater built into the air distributor protects your wine from any signicant fall in temperature.
Humidity:
This is an essential factor, enabling corks to retain their sealing qualities. The level of humidity must be higher than
50% (ideally between 60 and 75 %). By maintaining a constant evaporation temperature, above 0°C , your EuroC ave IN OA conditioner ensures minimal drying out of the air of your cellar and an ideal level of humidity.
Protection from light:
Light, and more especially its ultra-violet component, will rapidly prove noxious to your wine by irreversible oxidation of its tannins. For this reason we strongly advise that wines be stored in the dark, far from U.V. light.
P
rotection from vibration:
Vibration disturbs the slow process of your wine’s biochemical evolution, and is often fatal for the nest wines. The housing of your EuroC ave conditioner is fully sound-proofed (by 20 mm polyethylene foam) and the compressor and fans are tted with silent blocks to absorb any residual vibration.
Natural aeration:
A constant supply of air from the outside is also indispensable.
All of these specic features can
be found in the EuroCave IN O A conditioner you have bought. W e thank you for the
condence you have placed in us.
French wines
Alsace 10°C Beaujolais 13°C Bordeaux Sweet W hite 6°C Bordeaux Dr y W hite 8°C Bordeaux Red 17°C Bourgogne White 11°C Burgundy R ed 18°C Champagne 6°C Jura 10°C Languedoc-Roussillon 13°C Provence Rosé 12°C Savoie 9°C Vins de Loire D ry W hite 10°C Vins de Loire Sweet 7°C Vins de Loire R ed 14°C Vins du Rhône 15°C Vins du Sud O uest Sweet 7°C Vins du Sud O uest Red 15°C
Australian wines
Cabernet franc 16°C Cabernet sauvignon 17°C Chardonnay 10°C Merlot 17°C Muscat à petit grain 6°C Pinot noir 15°C Sauvignon W hite 8°C Semillon 8°C Shiraz 18°C Verdhelo 7°C
Other wines
C°61 ainrofilaC C°51 elihC C°71 niapS C°61 ylatI
Usual wine serving temperatures
WELCOME TO THE WORLD OF EUROCAVE
4
Page 5
1 - Conditioner / ceiling distance: 200 mm min. 2 - Ceiling 3 - Cellar wall 4 - Metal mounting frame 5 - Flexible ducting 6 - Aesthetic front panel 7 - Grid, to be cleaned regularly (see p.11) 8 - Mounting frame / conditioner seal 9 - Evaporator, to be cleaned regularly
10 -
Condenser, to be cleaned regularly
11 - Inside of cellar 12 - Remote control 13 - Grid securing screws (quantity: 24) 14 - Aesthetic front panel securing screws
(quantity: 4)
15 -
Screws to x frame to the wall (quantity: 4)
16 - Screws to x conditioner to the frame
(quantity: 4)
1 - CONDITIONER DESCRIPTION
HOT AIR
COLD AIR
5
Page 6
2 - IMPORTANT SAFETY RECOMMENDATIONS
Your conditioner’s power lead is supplied without a plug. Installation of a power plug or connection of the conditioner to a junction box must be carried out by a qualied electrician. In all cases, the connection of your conditioner must be carr ied out on an earthed socket to prevent any risk of electric shock. Have an electrician carry out the installation. He will tell you whether or not the socket is correctly earthed an
d,if necessary, will perform any work required
to bring your installation in line with standards.
IMPORTANT: any electrical work must be carried out by a qualied electrician.
Electric connection must be carried out by means of a device to ensure isolation from the mains system.T he isolating device should open all of the contacts of all the poles ensuring complete disconnection in line with the conditions in over-voltage categor y III
. Installation must be carried out in compliance with
national installation regulations.
Should you move to another country, check that the conditioner’s electrical rating (see grey identication label) complies with the country (voltage, frequency).
Ensure that the plug (230 V – 13 A*) is correctly earthed and that your installation
is protected by a dierential circuit breaker (30 mA*).
*not valid for some countries
3 - ELECTRICAL POWER SUPPLY
For your personal safety, the conditioner must be correctly earthed.
4 - CARE FOR THE ENVIRONMENT
AND ENERGY SAVING
Never use your conditioner for anything other than its specic pur pose as described in this guide. Never unplug the conditioner by pulling on the supply lead. Take a rm hold on the plug and pull out smoothly in a straight line from the wall socket. If the power lead is damaged, it must be replaced by a qualied electrician. Do not allow children to climb, sit, stand on or hang from the conditioner.They could damage the conditioner, as well as badly hurting themselves.
Never damage your app
liance’s refrigeration unit.
W hen using your conditioner, you should always observe certain basic precautions, especially:
Warning
Disposal of packaging: The packaging used by EuroC ave is made of recyclable materials. After unpacking your conditioner, take the packaging to a waste disposal centre. For the most part it will be recycled.
Recycling: A caring gesture Electrical and electronic equipment have potentially hazardous eects on the environment and public health due to the presence of noxious substances. You should therefore never dispose of electrical or electronic equipment with unsorted municipal waste. W hen buying a new EuroCave product (wine cabinet, cell
ar conditioner,Vin au Verre), you can take advice about the recycling of your old appliance from
your EuroCave dealer.
In compliance with legal provisions covering respect and care for the environment, your conditioner does not contain C FCs.
Energy saving:
- Install your conditioner in an
appropriate place and within the recommended temperature ranges.
- Keep the door open for as short a time as possible.
N.B.: Care for the environment: when replacing your conditioner, consult your local municipal refuse department in order to observe the appropriate recycling procedure. For refrigerant gases, substances and some parts contained in the conditioner, EuroCave uses recyclable materials which require a special packaging disposal procedure to be foll
owed.
Place unusable appliances out of use by unplugging them.
6
Page 7
INOA CELLAR CONDITIONER
EuroCave Inoa 25 Cellar conditioner
Dimension W385 x D322 x H1250 mm Weight: 43 KG Power supply 230V / 50 Hz
Volume up to 25 m3 (*)
Cooling Capacity 600W Electrical Power 500W (**) Heater element 650W Cooling Gas: R134a External Temp -5°C to 35°C Noise level: 44dbA – 50dbA Supplied with a 3.50 m power lead without plug Ref: INOA 25
EuroCave Inoa 50 Cellar conditioner
Dimension W385 x D322 x H1250 mm Weight: 46 KG Power supply 230V / 50 Hz
Volume up to 50 m3 (*)
Cooling Capacity 1200W Electrical Power 800W (**) Heater element 650W Cooling Gas: R134a External Temp -5°C to 35°C Noise level: 44dbA – 50dbA Supplied with a 3.50 m power lead without plug Ref: INOA 50
INOA 25 INOA 50
S PECI F ICATIONS
* for an isolated wine cellar following our advice please refer to our insulation guide ** for an internal temperature of 12°C and an external temperature of 32°C
F
UNCTION
The purpose of the cellar conditioner is to climate control any kind of fully insulated room creating an ideal wine cellar environment by monitoring and adjusting the temperature and humidity.
T EC H NOLO GY
The conditioner’s housing is dampened against sound and the compressor
and fans are fitted with silent blocks to absorb any residual vibration.
A quiet conditioner: the system automatically adjusts speeds to ambient temperature conditions, combined with the use of particularly quiet fans, allows the conditioner to operate very discreetly.
Energy efficiency: Inoa conditioners use the compressor infrequently, insulation between the condenser and the evaporator minimises any exchange between the cold and hot sections of the appliance, thus favouring energy efficiency.
The Inoa come as standard with the hot air discharge opposite the cold air exit. It can be ordered with the hot air exit on the left or the right side as an option.
Important information
For insulation, installing, positioning and more please make sure you have read our Installation guide and our Insulation guide.
5 - TECHNICAL SPECIFICATIONS
7
Page 8
2 - TECHNICAL SPECIFICATIONS
3 - CELLAR INSULATION
Dimensions Power Sample Cooling Weight Electrical Heating Refrigerant External in mm supply volume m
3
serutarepmetW ecnatsiserW rewopgKW yticapac
Inoa 25 W385 x D322 230 V up to 600 W** 43 Kg 550 W** 650 W R134a -5°C to 35°C
x H1250 / 50 Hz 25 m3 * (without CFCs)
Inoa 50 W385 x D322 230 V up to 1200 W** 46 Kg 800 W** 650 W R134a -5°C to 35°C
x H1250 / 50 Hz 50 m3 * (without CFCs)
* in a very well insulated room - ** for an internal temperature of 12° C and an external temperature of 32° C. Supplied with a 3.50 m power lead without plug.
Traditional building materials such as stone, concrete and brick are very poor insulators and only underground sections represent any real insulation. It is therefore essential, in the majority of cases, to insulate the entire room to be conditioned.
Insulate – yes but how?
We recommend that you use extruded polystyrene, currently the most ecient product on the market. It is the least ammable and the most durable material. It also has the advantage of not being attacked by rodents. Furthermore,extruded polystyrene boards can be layered and therefore prevent thermal bridges.To increase your conditioner’s lifespan and reduce electricity consumption, we recommend that you use extruded polystyrene which is at least 80 mm thick.
80 mm of extruded polystyrene provides the same amount of insulation as a 5m thick stone wall.
The insulation must be completely continuous (no gaps).
Insulation boards: dierent methods of tting are possible
How can you determine whether or not a material is a good insulator? The insulation performance of a material is established by its R thermal resistance (m2.°C/W). It determines the material’s ability to conduct heat. R = e/ λ - The greater the R coecient, the better the insulation. (λ = thermal conductivity coecient)
There are 3 types of insulation boards:
Insulator only, complex (with plaster cover) or sandwich (plaster both sides)
Depending on the type of insulator chosen, several methods of tting are possible:
Against the walls
- Standard extruded polystyrene board:pre-cut to the dimensions of the area to be conditioned,they are tted using high-bond mortar.For a more acceptable nish, it is possible to x rails onto which you screw the plaster board panels over the polystyrene.
- Sandwich or complex boards: the polystyrene is already integrated into the plaster board. Whatever the method used, all kinds of decorative nishes are possible to obtain an attractive wall. If you
only
want to condition a section of your room, install a plaster board dividing wall then insulate the side of the room to be conditioned.
N.B.: Before being insulated, walls must be clean.If they are too damp,clean them with a wire brush then clean with a high pressure water jet and paint with an emulsion paint.
On the ceiling and door
The process for insulating the ceiling and door is identical to that of the walls. We recommend that you use extruded polystyrene.
On the floor (insulation optional)
- Original clay oor: not insulating favours the passage of humidity, which is good for the wine.
- Concrete oor (for example): Concrete is a very poor insulator.A few centimetres of ne gravel can, in some cases, improve insulation.
It is essential that the surface material used for the oor (whether or not covering
insulation) can support the weight of wine racks and has resistance to compression.
Tools required
- handsaw, tape measure, bricklayer’s ruler, trestles, screwdriver or screw gun, drill, hammer,level, plumb line, wood mallet, spatula, precision knife...
8
Page 9
4 GB
7 - INSTALLING THE CONDITIONER
I - General points
- If the power lead is damaged, it must be replaced by a qualied electrician.
- Never damage the appliance’s refrigerating circuit.
Your conditioner’s power lead is supplied without a plug.“Fitting a power plug or connecting the conditioner to a junction box must be carried out by a qualied electrician. In all cases, connection of your conditioner must be carried out on an earthed socket to prevent any risk of electric shock. 230V-13A* earthed power outlet with dierential circuit breaker (30mA*) protected by a fuse.
*not valid for some countries
IMPORTANT : any electrical work must be carried out by a qualied electrician. Power outlet not valid for some countries.
Electric connection must be carried out by means of a device to ensure isolation from the mains system. The isolating device should open all of the contacts of all the poles ensuring complete disconnection in line with the conditions in over-voltage
category III. Installation must be carried out in compliance with national installation
regulations.
Positioning your conditioner:
The conditioner produces cold air inside the cellar and expels hot air outside (see diagram A).
- Do not install the conditioner facing the door of the room (risk of condensation on the door joints).
- Do not place the external section of the conditioner above a source of heat.
- For insulation reasons, there must be no windows or bay windows in the room to be conditioned.
- No piped hot water must pass through the room to be conditioned (e.g. under-oor heating).
- Is it not better to state that pipes with hot water must be insulated so that there is no heat loss?
- The exterior of the conditioner must not be located in an area subject to atmospheric exposure.
- No heat-producing appliance must be located in the area to be conditioned (e.g. refrigerator, radiator, boiler).
- Do not obstruct the air entry and exit points.
- Never place a container or
object containing liquid on top of the conditioner.
- The room where the hot air is expelled must, ideally, be approximately twice as large as the wine cellar and well ventilated so that the hot air can be properly expelled.
- Wait 48 h before plugging in so that the uids in the internal circuits can settle.
- Never connect several conditioners to a multi-socket.
Recommendations:
- Fit your conditioner as close as possible to the ceiling in order to ensure uniform dispersal of cold air in the cellar.
- We recommend that you leave a space of 200 mm between the ceiling and conditioner housing to make it easier to t the appliance onto its base.
- Air outlets (hot and cold) must not be obstructed by any obstacles (minimum distance: 1500 mm). Direct the cold air outlet so it is facing the bottles (see diagram D).
Installation: (see B diagrams) The conditioner was designed to be completely modular and adapt to any type of cellar. You
can, amongst other options, install it either outside or inside your cellar, position it close to the oor (xed to the wall) or at a height (we recommend, however, installing it at a height for improved air convection). Additionally, hot air can be expelled from dierent angles (to be specied when ordering): facing forwards, right or left. You also have the option of expelling hot air outside the room by way of extractor piping (standard piping, 160 mm in diameter, not supplied). Finally, you can choose to t the conditioner onto a door.
Ventilated room
Temperature: Max.: 35°C Min.: -5°C
CELLAR
Diagram A
Bottles
Door
Door
Conditioner
Conditioner
CELLAR
CELLAR
Diagram D
Hot air expelled
Cold air discharged
Cold air discharged
Conditioner housed inside the cellar
with extraction facing forwards /
aesthetic front panel on the outside
Conditioner housed outside the cellar with extraction facing forwards / aesthetic front panel on the inside
Conditioner housed outside the cellar
with extraction on the left side /
aesthetic front panel on the inside.
Conditioner housed inside the cellar, tted onto an adapted door.
Diagram B Diagram B
Diagram B Diagram B
Bottles
Door Conditioner
CELLAR
Bottles
Hot air expelled
9
Page 10
7 - INSTALLING THE CONDITIONER
Fitting: (see C diagrams) The conditioner comes supplied with a metallic mounting frame which simplies the process of drilling air entry and exit holes. It also has extendable ducting to be cut to length (75 cm each) in order to install the conditioner whatever the thickness of the wall. Finally, the conditioner is supplied with an aesthetic front panel and 4 grids for an aesthetic appearance.
II- Drilling the wall
- Determine the location of the conditioner housing (inside or outside the cellar)
- Position the metallic mounting frame:(1)
in relation to the ceiling if tting the conditioner at a height (maintain a distance of 200 mm between the top of the frame and the ceiling),
in relation to the oor for a low tting (maintain a distance of 80 mm between the bottom of the frame and the oor).
- Use the metallic frame to outline the position of the 2 drill holes (2).
- Drill the wall.The holes must be larger than the outline drawn – between 210 mm min. and 280 mm max.
III- Fitting
- Fold the ring’s 4 supports inwards (1).
- Fit
the 2 extendable ducts onto the rings of the metallic frame (2).
- Screw the securing rings onto the ducts (3).
- Position the metallic frame while passing the exible ducts through the 2 holes drilled into the wall (4).
- Push back the 4 supports towards the outside of the ring (5).
- Screw the metallic frame onto the wall with 2 high screws and two low screws (not supplied).Use screws suitable for the wall material (6).
- We recommend that you put a bead of silicone between the plate and the wall to ensure eective sealing.
- Pull the 2 ducts (xed to the metallic frame) through the other side of the wall (7).
- Stretch the ducts to the maximum in order to make them as smooth as possible (8).
- Cut the ducts ush with the wall using a Stanley knife for the material (9) and pliers for the metallic wiring (10).
(1)
(1) (2) (3) (4) (5)
(2)
(6) (7) (8) (9) (10)
Metallic mounting frame
Extendable ducting
Wall drill holes
Aesthetic front panel
Aesthetic front panel
Grid
Grid
Wall drill holes
Extendable ducting
Metallic mounting frame
C margaiDC margaiD
Conditioner housed inside the cellar
Conditioner housed outside the cellar
10
Page 11
11
Page 12
7 - INSTALLING THE CONDITIONER
- Position and t the aesthetic front panel to the wall (screws not supplied). Use screws suitable for the wall material (11).
- We recommend that you put a bead of silicone between the panel and the wall to ensure eective sealing.
- Fold the ange’s 4 supports inwards (12).
- Place the ducts onto the anges ensuring that they are well secured on the supports (13).
- Push the 4 supports towards the outside of the ange (14).
- On the side of the conditioner to be placed against the wall unscrew the 2 grids from the housing using the supplied Hex wrench and retain the screws.) (15).
- Using the screws retained in the last instruction, screw the 2 grids onto the aesthetic front panel (16).
- Unscrew the 2 screws on the top of the conditioner using a Hex wrench (supplied), on the side to be placed against the wall. Retain the two screws (17).
- Fix the conditioner housing to the metallic
frame, taking care to press rmly onto the foam (18).
- Screw down the conditioner housing using 2 screws at the top (those retained earlier) and 2 screws at the bottom (supplied in the accessories packet) (19).
Fitting onto a door:
You can t the conditioner onto a door. In this case, it is ESSENTIAL to check that the door is capable of supporting a weight of 46 kg and that it does not produce vibration. The procedure for tting is the same as for the wall.
Fitting close to the floor:
When the conditioner is tted close to the oor it is ESSENTIAL that it is xed to the wall.
Conditioner with air extraction via piping:
Repeat the steps described at the beginning of paragraph III.
Conditioner housed outside the cellar:
- On the conditioner housing, unscrew the 2 grids (openings that will not be placed against the wall) using a Hex wrench (supplied).
- Where the grids were located, position and screw, using a Hex wrench (supplied) the 2 anges* onto the housing (1) and (2).
- Fit together the reducer* (3).
- Position the air extraction piping (standard piping, 160 mm in diameter, not supplied).
*Consult your EuroCave distributor
(11)
(16)
)3()2()1(
(17) (18) (19)
(12) (13) (14) (15)
12
Page 13
7 - INSTALLING THE CONDITIONER
Conditioner housed inside the cellar:
There are 2 methods for attaching the hot air extraction piping:
- Attaching the piping directly to the aesthetic front panel:
- Position and screw, using a Hex wrench (supplied), the two supplied anges* onto the aesthetic front panel (1).
- Fit together the reducer (2).
- Position the air extraction piping (standard piping, 160 mm in diameter, not supplied) (3).
- Attaching the piping directly to the conditioner housing (the extraction piping passes through the wall):
If using this method, you must not use the exible ducting supplied with the
conditioner.
- Fit the reducer* directly onto the mounting frame through the wall (1).
- Position the air extraction piping (standard piping, 160 mm in diameter, not supplied) (2) (3).
For this type of fitting, it is necessary to ensure sealing around the piping.
*Consult your EuroCave distributor
IV- Discharging condensate
The conditioner was designed to allow condensate to be discharged (discharge pipe located under the conditioner’s housing) either inside
the cellar, if the humidity level is too low, or outside the cellar. Simply pass the pipes through the wall to discharge the condensate into the room next to the conditioner housing.
Ensure that the piping is not cramped.
(1) (2) (3)
(1) (2) (3)
13
Page 14
8 - CONDITIONER OPERATION
Cold air
Hot air
(heated if necessary)
Hot air
Evaporator
Condenser
Compressor
Fan
Turbine
Heater
The IN OA conditioner is tted with a refrigerating unit:
an evaporator forces cold air inside the room,
a condenser expels the hot air outside.
14
The evaporator fan operates continuously to ensure that air is constantly mixed and that temperatures are as uniform as possible,in accordance with speeds automatically adjusted according to requirements.
Page 15
I- Remote control description
Radio frequency remote control (433.92 Mhz) Each remote control has a personalised code matched to the conditioner. Power supply: 2 x 3V (CR 2430 battery, supplied)
II- Installing the remote control inside the cellar
We recommend that you place the remote control as close as possible to the bottles.
Fit the unit close to your bottles using the supplied pegs and screws (see diagram below)
NB: Do not place the remote control in the path of the conditioner’s cold air ow.
Temperature indicator
Low battery indicator
Knob
9 - INSTALLING THE REMOTE CONTROL
Temperature units (according to the country)
Conrmation and on/o key
Temperature and setting display
Adjustment keys
On / o indicator
15
Page 16
III- Installing the remote control outside the cellar
The remote control can also be placed outside the cellar. In this case, it is essential to connect a sensor (supplied with the appliance) to the remote control before installing it.
a- Connecting the sensor to the remote control
- On the back of the remote control, push the 2 batteries downwards using a screwdriver (see diagram below).
- Remove the central knob, unscrew the screw with a small screwdriver and open the unit (see diagram below)
On the back, connect the sensor’s 2 wires (blue and red) to the circuit connector using a small at screwdriver (see diagram below). You can connect either the blue wire or the red wire to the circuit connector. Pass the wires through the recess on the top of the unit.
- Close the unit, ensuring that the wires pass through the recess and are not jammed
- Rescrew and replace the central knob
9 - INSTALLING THE REMOTE CONTROL
Battery CR2430
16
Page 17
- Programming the remote control
Where placing the remote control outside the cellar, having connected the external sensor, it is essential to reprogramme the unit
- To turn on the remote control, press and hold down the key for about 8 seconds until the indicator goes o.
- First press and continuously hold down the key, at the same time press and continuously hold down the key for several seconds until three
lines appear.The model number is then displayed and ashes. .
- Press .
- The screen appears indicating IN (IN= internal installation). Press the key to change to OUT external mode.
- The display appears indicating OUT (OUT= external installation). Press to conrm.
- The pictogram appears. Press .
- The screen appears. Press .
- The pictogram appears. Press .
- .appears. Press .
- The pictogram appears. Press .
- The screen appears, then .
If you wish to reprogramme the remote control for
an internal sensor, disconnect the wired sensor and reprogramme the remote control in internal mode
(IN) by repeating the rst two steps described in the paragraph above (see 5-III-b p.11):
The 2nd screen displays indicating OUT (OUT= external installation). Press the key to change to IN internal mode. Press to conrm.
Then repeat the same steps, as indicated in the above paragraph (see 5-III-b).
c- Fitting
- Fit the remote control and sensor using the screws and pegs supplied (see diagram on page 9, chapter II).
- Place the sensor inside the cellar.
- Place the sensor as close as possible to the bottles N.B.: the sensor has a range of 3 metres.
9 - INSTALLING THE REMOTE CONTROL
17
Page 18
10 - COMMISSIONING YOUR CONDITIONER
I- Connection
Check that the plug is connected to a power supply (presence of correct amp fuses, functioning 30 mA* dierential circuit breaker - not applicable to cer tain countries).Wait 48 hours before plugging in your conditioner.
II- Switching on
- Place the switch, located under the conditioner, in position 1.
- Press and hold down the key on your remote control for about 8 seconds, until the indicator goes o.
To put your conditioner on stan
dby,press and hold down the key on your remote control for about 5 seconds and release it before the indicator
goes o.
III- Remote control description
Radio frequency remote control (433.92 Mhz). Each remote control has a personalised code matched to the conditioner.
Temperature indicator
Low battery indicator
Knob
Temperature units (according to the country)
Conrmation and on/o key
Temperature and setting display
Adjustment keys
O n / o indicator
18
Page 19
10 - COMMISSIONING YOUR CONDITIONER
IV- Installing the remote control
You can install the remote control inside your cellar. We recommend that you place it as close as possible to the bottles. Fix the unit close to your bottles using the supplied pegs and screws (see diagram below)
N.B.: D o not place the remote control in the path of the conditioner’s cold air ow.
It is also possible to place the remote control outside the cellar. In this case, an external sensor (supp
lied) must be connected to the remote control and then the remote control must be reprogr ammed.
For further details, contact your EuroCave retailer.
V- Setting the temperature
Setting the temperature of your conditioner is carried out entirely from the remote control which has the following layout:
- Temperature display: displays the actual temperature inside your cellar.
- Setting keys: allow you to select the desired temperature inside the cell
ar.
To adjust the temperature:
- Press then immediately release the key. The setting then appears (the temperature ashes).
- - W hen the temperature ashes, you have 7 seconds to change the setting by pressing the or keys, otherwise the display automatically returns to the previous setting.
The recommended setting range for maturing wine: 10 to 14° C.
Temperature units (according to the country)
Selection and conrmation key
Cellar temperature display
Cellar temperature setting keys
Temperature indicator
19
Page 20
10 - COMMISSIONING YOUR CONDITIONER
- Press the key to conrm the new setting, the display then returns to the new setting.
The setting can be adjusted between 9 and 15°C. Beyond this range, the and keys do not work.
WARNING: to operate correctly, your conditioner must be in a location where the ambient temperature is between -5°C is 35°C.
W hen making signicant modications to temperature settings, it can take several hours for the temperature in your cellar to stabilise and for the conditioner to display the desired temperature.
VI- Silent function
Your EuroC ave conditioner is tted with a silent function which allows the sound level to be reduced when you enter the cellar.
W hen the conditioner is on:
- Press and hold down the key for 3 seconds.
The display then appears. N ext the current temperature is displayed.
You will be able to see this function via the pictogram which ashes for 15 minutes.
The compressor then remains in operation an
d the fans change to slow speed for 15 minutes.
After this, the conditioner returns to the default operating speed.
VII- Heating function
The EuroC ave IN OA conditioner has a heater (650 W ) allowing the internal temperature in your cellar to be maintained at an optimal level. As soon as the temperature drops below the programmed temperature, the heating function is automatically activated.
VIII- C hanging the remote control batteries
Remote control power supply: 1 x 3 V (CR 2430 battery) (2 batteries supplied) Battery life: 2 years approx The remote control is supplied with 2 batteries. O nly one battery is required (pull o the plastic strip to make it useable). The other battery is a spare.
- W hen the battery runs out, the pictogram ashes on the remote control’s display.
- Take the remote control o the wall.
- On the back of the remote control, push the used batt
ery down using a screwdriver (see diagr am opposite).
- Pull the strip from the spare battery, which will then be ready for use.
- Remember to buy a replacement for the spare battery.
IX - Discharging condensate
Your conditioner was designed to allow condensate to be discharged (discharge pipe located under the conditioner’s housing) either inside the cellar, if the humidity level is too low, or outside the cell
ar.
Simply pass the pipe through the wall to discharge the condensate into the room next to the conditioner housing.
Ensure that the piping is not kinked.
20
Page 21
12 - OPERATING FAULTS
If the conditioner is not working, there may be loss of synchronism between the appliance and the remote control.
Synchronising procedure:
- Remove the conditioner housing upper cover (4 screws) (1).
- To turn on the remote control, press and hold down the key for about 8 seconds, until the indicator goes o.
- Place the switch, located under the conditioner, in position 1. The green LED on the board comes on (2).
- Press and hold down the On/O button (brown button) on the board for more than 6 seconds, then release (3).The green LED will then start to ash (synchronising mode).
- Simultaneously press the and keys on the remote control until ! is displayed .
- As soon as the green LED on the board stops ashing (end of synchronising mode), the conditioner and remote control are then synchronised.
- Exit "RF" mode by pressing the key on the remote control.
(1) (2) (3)
On/ o button
Green LED
11 - MAINTENANCE
It is necessary to thoroughly clean the conditioner’s internal elements every year.
- Unplug the appliance.
- Place the appliance on the ground to disassemble it (4 screws).
- Vacuum the 4 air entry and exit grids.
- Remove the upper cover (2 screws) (1).
- Snap o from the top the 2 columns in order to access the 8 screws of the 2 front sections (2).
- Disassemble the front sections by removing the screws (square end pieces, not supplied).
- Thoroughly clean the ribs of the 2 exchangers with a vacuum cleaner (3).
- Repeat these instructions in the opposite order to reassemble the appliance.
(1) (2) (3)
Ribs of the 2 exchangers
21
Page 22
12 GB
WARNING
The information in this document is subject to modication without prior notice. EuroCave oers no guarantee on this equipment item if it is used for any specic purpose other than that for which it was designed. EuroCave cannot be held responsible for any errors in this manual, nor for any damage linked to or following the provision, performance or use of the equipment item. All photocopying, reproduction, translation, wether partial or total, are strictly prohibited, without prior written consent from EuroCave.
22
Page 23
www.eurocave.co.uk - eurocave@aroundwine.co.uk
Around Wine 40 New Cavendish Street London W1G 8UD 020 7935 4679 eurocave@aroundwine.co.uk
23