ETQ IN800 i Owner's Manual

THEMETHOD OF GASOLINE PRESSURE ADDING DEVICE:
When the gasoline inside the tank is less than halfway, and also meets the following situations. Then there is a need to use the pressure adding device.
1). First time using the engine.
3). If the engine is working for more than a half hour, and stopped for 10 minutes you will need to restart.
Following steps need to do one by one:
1). turn the air intake switch to "off " position
1. off 2. on
Picture 1 Picture 2
2). After the engine is running, turn the air intake switch to the “On” position.
3). Move the adding pressure device “up and down” several times, until you can feel the pressure
when moving the device “down”.
Picture 3
4). wait 10-20 seconds, then you can start it.
*Remark: Need to add: inverter products working environment temperature: MAX 40
1. Do not open the plastic cover to operate the product.
2. If cover is opened it will damage the engine because the inner heat of the unit will not be able to dissipate appropriately.
3. The unit cannot be used if any parts have been disassembled.
1
PREFACE
Thank you for purchasing products from EASTERN TOOLS & EQUIPMENT, INC. We appreciate your
business. The following manual is only a guide to assist you and is not a complete or comprehensive
manual of all aspects of maintaining and repairing your generator. The equipment you have
purchased is a complex piece of machinery. We recommend that you consult with a dealer if you have
doubts or concerns as to your experience or ability to properly maintain or repair your equipment. You
will save time and the inconvenience of having to go back to the store if you choose to write or call us
concerning missing parts, service questions, operating advice, and/or assembly questions. Our
gasoline generators have some of the following features:
• Lightweight construction
• Air cooled
• Four-stroke gasoline internal combustion engine
• Recoil starter
• Large fuel tank
• Automatic voltage stabilizer
• Circuit protector
• AC and DC outputs
• Low oil level sensor
The ETQ air-cooled gasoline generators are widely used when electrical power is scarce. Our
generators provide a portable mobile solution in supplying power for field operations during project
construction.
This manual will explain how to operate and service your generator set.
If you have any questions or suggestions about this manual, please contact your local dealer or us
directly. Consumers should notice that this manual might differ slightly from the actual product as
more improvements are made to our products. Some of the pictures in this manual may differ slightly from the actual product as well. Eastern Tools and Equipment, Inc. reserves the right to make changes at any time without notice and without incurring any obligation.
The engine exhaust from this product contains chemicals known to the state of California to cause
cancer, birth defects or other reproductive harm.
Please read manual before operating this machine.
The generator is a source of electricity, and can cause electrical shocks that can cause severe injury or
death if misused. Do not operate with wet hands and do not let the generator get wet. Keep away from
rain and snow.
2
TABLE OF CONTENTS
1)
SAFETY PRECAUTIONS 03
2)
COMPONENT IDENTIFICATION 05
3)
PRE-OPERATION CHECK 07
4)
STARTING THE ENGINE 10
5)
GENERATOR USE 12
6)
STOPPING THE ENGINE 15
7)
MAINTENANCE TIPS AND INSTRUCTIONS 17
8)
TRANSPORTING/STORAGE 23
9)
TROUBLESHOOTING (FAQS) 24
10)
SPECIFICATIONS 25
11)
WARRANTY 26
3
1) SAFETY PRECAUTIONS
z Generator is designed to give safe and dependable service if operated according to instructions.
z Read the Owner’s Manual before operating the generator.
z Failure to do so could result in personal injury or equipment damage.
z Operate the generator ONLY outdoors, and at least 3 feet away from open doors or windows.
z Never run the generator indoors as the engine gives off poisonous carbon monoxide, an odorless
and colorless gas.
z Inhaling carbon monoxide will cause nausea, fainting or death.
z Keep the generator at least 3 feet away from flammable matter for adequate ventilation.
z Be sure to stop the engine before refueling.
z Do not overfill the fuel tank.
z If fuel is spilled, wipe it away carefully and wait until the fuel has dried before starting the engine
again.
z When changing oil, make sure that the fuel cap is tightly secured to prevent fuel leakage.
4
z The muffler is very hot during operation, and remains hot for some time after the engine has
stopped. Do not touch the muffler while it is hot.
z Allow the engine to cool down before moving the generator (Pay attention to the warnings that are
attached to the generator).
z Connections between standby power and a building’s electrical system must be installed by a
qualified electrician, and must comply with all applicable laws and electrical codes.
z Improper installation may cause electrical current to run back into the electrical transmission lines,
which may electrocute utility company workers or others who come into contact with these lines during a power outage.
z If the generator is not installed properly, it may explode, burn, or cause a fire in the building’s
electrical system when the power is restored.
z Always conduct a pre-operation inspection (see page 7) before starting the engine.
z Place the generator at least 1m (3ft) away from buildings or other equipment during operation.
z Operate the generator on a level surface. If the generator is tilted, fuel spillage may result
z Know how to stop the generator quickly and understand the operation of all the controls. Never
operate without proper instructions.
z Keep children and pets away from the generator when it is in operation.
z Keep away from rotating parts while the generator is running.
z The generator can cause electric shocks when misused; do not operate with wet hands.
z Do not operate the generator in rain or snow, and do not allow the generator to get wet.
5
2) COMPONENT IDENTIFICATION
FUEL CAP LEVER
FUEL CAP
CHOKE LEVER
Picutre 4
CONTROL PANEL
LEFT SIDE MAINTENANCE COVER
FUEL VALVE
STARTER GRIP ENGINE SWITCH
SPARK PLUG MAINTENANCE COVER
MUFFLER
Picture 5
6
CONTROL PANEL
OUTPUT INDICATOR LIGHT
OVERLOAD INDICATOR LIGHT
OIL ALERT INDICAT OR LIGHT
Picture 6
AC RECEPTACLE
GROUND
7
3) PRE-OPERATION CHECK
Be sure to check the generator on a level surface when the engine does not work.
1) Check oil level.
Open the left side maintenance cover by unscrewing the cover screw. Remove the oil filler cap,
and wipe the dipstick with a clean rag. Check the oil level by inserting the dipstick in the hole
without screwing it in. If the oil level is below the end of the dipstick, add the recommended
amount of 0.25 litre of SF 10W-30 oil to the crankcase.
CAUTION:
OIL FILLER HOLE
UPPER LEVEL
Select the engine oil according
to the surrounding temperature.
Surrounding temperature (° C)
OIL FILLER CAP
Use high-detergent, premium quality, 4-stroke engine oil. Using non-detergent oil or 2-stroke engine
oil could shorten the service life of the engine. Running the generator with a low oil level could result
in serious damage to the engine.
NOTE: The Oil Alert System will automatically stop the engine before the oil level falls below the safe
limit. In order to avoid the inconvenience of an unexpected shutdown, it is recommended that the oil level be checked on a regular basis.
2) CHECKING THE FUEL LEVEL
Verify that the generator has sufficient fuel before each use. When adding fuel after the
generator has been used, verify that the generator is turned OFF, and allow it to cool down.
If the fuel level is low, refill the fuel tank to the proper level, as specified. Unleaded or low-lead gasoline is recommended in order to minimize deposits in the combustion chamber. Use gasoline within 30 days of purchase. Using old gasoline may cause
problems. Securely tighten the fuel filler cap after refueling.
Verify that the generator is properly grounded in accordance with local requirements.
Before adding fuel, all electrical loads must be disconnected and the generator must be turned off.
8
Fuel Tank Capacity: 1.8L
UPPER LIMIT MARK
FUEL CAP
Picture 7
3) CHECKING THE AIR FILTER
Check the air filter in order to verify that it is clean and in good condition. Loosen the cover screw
and remove the left side maintenance cover. Press the latch tab on the top of the air filter body,
remove the air filter cover, and check the air filter. Clean or replace the air filter if necessary.
CAUTION: Do not run the engine without an air filter. Rapid engine wear will result from
contaminants such as dust and dirt being drawn into the engine through the carburetor.
Picture 8
OPEN
COVER SCREW
MAINTENANCE COVER
LEFT SIDE
Picture 9
AIR CLEAN COVER
COVER SCREW HOLE
9
Loading...