LAMP REPLACEMENT:
1. Switch o the electricity at the mains.
2. Pull the bezel o the front of the tting.
3. Pull the bezel o the front of the bulb
4. Turn the lamp anti-clockwise to remove from the lampholder.
5. Fit a new lamp.
REPLACEMENT LAMP TyPE:
• MAINS requires 1 x GU10 PAR16 energy saving lamp
(not included)
• LOW VOLTAGE requires
saving lamp (not included)
• Fittings are rated at 50W max.
Issue 2013
1 x GU5.3 MR16 energy
FOR PRODUCT ADVICE:
• T: 01933 673 144
• F: 01933 678 083
CLEANING:
Clean this light tting only with a soft dry cloth. Do not use any chemical or abrasive cleaners.
Do not use any chemical or abrasive cleaners.
EVENTUALLy, yOU MAy WANT TO REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” eective August 2005—UK WEEE Regulations eective 2nd January 2007). Environment Agency Registered Producer: WEE/ GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST  DO NOT DISPOSE WITH HOUSEHOLD WASTE.
IF yOU ExPERIENCE PROBLEMS:
If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specic instructions regarding individual installations.
0.5M
Visit our website:
www.eterna-lighting.co.uk
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
GU10
Pack contents:
1 x Fitting
Model:
SLGUCR / SLGUSN / SLGUWH
SLLVCR / SLLVSN / SLLVWH
Mains / Low Voltage IP65 Shower Light
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
GU5.3
Page 2
READ THIS FIRST:
Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.
This product contains glass, care must be taken when assembling, tting or handling to prevent personal injury or damage to the product.
This light tting must be installed by a competent person in accordance with the Building Regulations making reference to the current edition of the IEE Wiring Regulations (BS7671). The Building Regulations may be obtained from OPSI or viewed and downloaded from www.communities.gov.uk following the link for Building Regulations.
As the buyer, installer and/or user of this produc t it is your own responsibility to ensure that this tting is t for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.
This product is designed and constructed according to the principles of the appropriate British Standard and is intended for normal domestic service. Use of this tting in any other environment, for example where prolonged periods of use may be expected and/or higher than normal ambient temperatures, may result in a foreshortened working life.
Switch o the mains before commencing installation and remove the appropriate circuit fuse.
When working at heights, please use a suitable platform.
Suitable for indoor use only.
This product is suitable for use in living areas, and Bathroom zones 1 and 2 (see diagram below and current IEE Wiring Regulations for details). If being tted in a bathroom a 30mA RCD must be used.
Bathroom Zones Diagram
ZONE 1
ZONE 2
ZONE 2
225cm
60cm radius from tap
This product is suitable for installation on surfaces with normal ammability e.g. wood, plasterboard, masonry. It is not suitable for use on highly ammable sur faces (e.g. polystyrene, textiles).
ZONE 0
60cm240cm
If installing/mounting a light tting to a plastic ceiling, you must seek advice from the ceiling manufacturer regarding the type and specication of light ttings that may be used. Light ttings that generate and retain heat such as halogen downlights or ush ttings with incandescent lamps, may damage or discolour a plastic ceiling.
Before making xing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.
Do not cover the t ting with any insulating materials.
The lamp must be positioned so that there is at least
0.5m (500mm) between the bulb and any illuminated surface. Spotlights should be positioned well away from curtains and beds to ensure this distance is maintained.
Do not attach to surfaces which are damp, freshly painted or otherwise electrically conductive (e.g. metallic surfaces).
If the location of your new t ting requires the provision of a new electrical supply, the supply must conform with the requirements of the Building Regulations making reference to the current edition of the IEE Wiring Regulations (BS7671).
This product is designed for permanent connection to xed wiring: this should be either a suitable lighting circuit (protected with a 5 or 6 Amp MCB or fuse) or a fused spur (with a 3 Amp fuse) via a fused connection unit. We recommend that the supply incorporates a switch for ease of operation.
Make connections to the electrical supply in accordance with the following code:
Live: Brown or Red Neutral: Blue or Black
When making connections, ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation. Wrap loose terminal blocks well with insulating tape.
This tting is double insulated; do not connect any part to ear th.
You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation there are electrical tests that should be carried out: these tests are specied in the Wiring Regulations (BS7671) referred to in the Building Regulations.
INSTALLATION:
01. Choose the location for your new tting according to the conditions listed above.
02. Cut a hole of 70mm diameter in your ceiling, Fig 1.
03. Undo the screw in the centre of the terminal block and lift o the cover.
04. Make the connections to your mains supply. Note
that the terminals are not polarised i.e. you may connect either Live or Neutral (Brown or Blue) wires to either terminal.
05. Attach the bracket complete with terminal block to the body of the tting and secure using the screw supplied, Fig 2.
06. Holding the spring clips upwards and with the
lampholder hanging down through the middle, oer the body of the tting into the hole and allow the springs to pull the tting up to the ceiling, Fig 3.
07. Fit a suitable lamp to the lampholder, insert and
turn clockwise until it stops.
08. Clip the lamp into the three clips in the back of
the bezel, Fig 4.
09. Press the bezel, complete with lamp, up into the
tting until pressed fully up to your ceiling, Fig 5.
10. Restore the power and switch on.