ETC Source Four PARNel User Manual

Copyright © 2008 Electronic Theatre Controls, Inc.
All Rights reserved.
Product information and specifications subject to change.
Part Number:
7061M1250-06.01
Rev B
Released: June 2008
User Manual
Production Dates: September 2004 - Present
i Table of Contents
Table of Contents
ETC®, Emphasis®, Expression®, Insight™, Imagine™, Focus™, Express™, Unison®, Obsession® II, ETCNet2™, EDMX™, Source Four
®
, Revolution®, Sensor®, and WYSILink™ are either registered trademarks or trademarks
of Electronic Theatre Controls, Inc. in the United Stat es and other countries.
All other trademarks, both marked and not marked, are the property of their respe ct ive owners.
ETC in te nds this do cumen t, whether pr inted o r electronic, to be provid ed in its e nt irety.
Basic Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Fixture information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Color frame holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Replacing the HPL lam
p . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Focus knob positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Lens identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Changing front lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Cleaning glass lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning the reflector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Basic Assembly 1
Basic Assembly
WARNING:
Please note the following safety warnings before use:
Do not mount the fixture on or near combustible surfaces.
Do not operate the fixture without a lens installed.
Always hang the fixture with the color frame retaining clip in the locked position.
Figure 1
Yoke locking knob
Clear lens
Lamp housing
Yoke
Lens rotating ring
Color frame holder
Color frame
Lens catcher
Gel retaining clip
Tabs
Stippled lens
Focus knob
2 Source Four PARNel User Manual
Fixture information
HPL lamp table
Color frame holder
The color frame holder is equipped with a spring-loaded retaining clip that prevents color frames and accessories from falling out. See Figure 2.
Step 1: Release the retaining clip by pushing it sideways while gently pulling backwards.
Step 2: Insert the color frame.
CAUTION:
Do not use lamps other than the HPL in Source Four fixtures. Use of lamps other than HPL will void UL/cUL safety compliance and your warranty.
Lamp code Watts Volts Initial Lumen Color temp. Average rated life
HPL 780/77* 750 77 22,950 3,250° 300 hours
HPL 550/77* 550 77 16,170 3,250° 300 hours
HPL 550/77X* 550 77 12,160 3,050° 2000 hours
HPL 750/115 750 115 21,900 3,250°K 300 hours
HPL 750/115X 750 115 16,400 3,050° 1500 hours
HPL 575/115 575 115 16,520 3,250°K 300 hours
HPL 575/115X 575 115 12,360 3,050°K 2000 hours
HPL 375/115 375 115 10,540 3,250°K 300 hours
HPL 375/115X 375 115 8,000 3,050°K 1000 hours
HPL 750/120 750 120 21,900 3,250°K 300 hours
HPL 750/120X 750 130 16,400 3,0500°K 1500 hours
HPL 575/120 575 120 16,520 3,250°K 300 hours
HPL 575/120X 575 120 12,360 3,050°K 2000 hours
HPL 750/230 750 230 19,750 3,200°K 300 hours
HPL 750/230X 750 230 15,600 3,050°K 1500 hours
HPL 575/230 575 230 14,900 3,200°K 400 hours
HPL 575/230X 575 230 11,780 3,050°K 1500 hours
HPL 375/230X 375 230 7,250 3,000°K 1000 hours
HPL 750/240 750 240 19,750 3,200°K 300 hours
HPL 750/240X 750 240 15,600 3,050°K 1500 hours
HPL 575/240 575 240 14,900 3,050°K 400 hours
HPL 575/240X 575 240 11,780 3,050°K 1500 hours
HPL 375/240X 375 240 7,250 3,000°K 1000 hours
* To be used with ETC Dimmer Doubler™
WARNING:
Make sure all color frame accessories are locked in position with the retaining clip before hanging the fixture.