ETC SmartLink LinkPower Supply Kit User Manual

ETC® Setup Guide
SmartLink™ LinkPower Supply Kit

Overview

One SmartLink LinkPower Supply (S-LPS) powers up to four wall stations over the SmartLink™ network.
Note:
You may have only one station power source on the SmartLink network. This source may be either the LinkPower Supply (S-LPS) or a SmartLink Station Power Module (S-SPM) which powers up to 16 SmartLink stations. As well, you may have up to four SmartLink host products in a SmartLink system. One SmartLink host product (SmartPack, SmartSwitch, Unison DRd with SmartLink or Sensor + with SmartLink) in the system must have a LinkPower Supply or Station Power Module installed for wall station power.
Due to the similar design for the SmartPack Wall Mount and the SmartSwitch Relay Panel control terminations, the following instructions may be used for either product.

Installation Procedur e

The LinkPower supply kit (7021K1010) includes a LinkPower supply and four screws.
Step 1: Remove power from the control electronics.
For a SmartPack Wall Mount, turn the Standby breaker off.
For a SmartSwitch relay panel, turn the circuit breaker off at the breaker panel.
Step 2: Remove the two screws securing the I/O panel to the chassis.
Step 3: Fold the I/O panel down to reveal the control terminations.
Step 4
Step 5
LinkPower
supply
I/O board
Step 4: Angle the LinkPower supply board approximately 10°, insert the four pins as found on the
LinkPower supply into the receptacle on the I/O board.
Step 5: Align the LinkPower supply with the four screw mounts located on the I/O panel and
secure with the four screws provided.
Do not over-tighten the screws.
Step 6: Close the I/O panel and secure with the two screws.
Step 7: Re-apply power to the control electronics.
If you are having difficulties, contact ETC Technical Services directly at one of the offices listed in the contacts list below.
Corpora te H eadquarter s London , UK Rome, IT Holzkirch en, DE Hong Kon g Service: Web: 7024M22 00
Via Ennio Q uirino Vi sconti, 11, 001 93 Rome , Italy Tel +39 (0 6) 32 111 683 Fax +44 (0) 20 8752 8486
Rm 1801, 18/F, Tower 1 Ph ase 1, Enterprise Squ are, 9 Sh eung Yuet Roa d, Kowloon Bay, K owloon, Hong Kong Tel + 852 2 799 1 220 F ax +852 2799 9325
(Amer icas) se rvice@etcconne ct.com (UK) s ervic e@etceur ope.com (DE) techse rv-hoki@etcconne ct.com (Asia) se rvice@etc asia.com
www.etcconnect.c om
Rev B Rel ease d 2009- 06  ETC intend s this document t o be pr ovided i n its e ntirety.
3031 P leasan t Vi ew Road, P.O. Box 6 20979, Middleto n, Wisconsin 53 562-097 9 USA Tel +608 8 31 4116 Fax +608 8 36 1736
Ohms trasse 3 , 8360 7 Holzkirchen, Ge rman y Tel +49 (8 0 24) 47 00-0 Fax +49 (80 24) 47 0 0-3 0 0
Copyright © 2009 ETC. All Right s Reserved. P roduct info rmation and specific ations subject to change.
.cnI ,slortnoC ertaehT cinortcelE1 fo 1 egaPnoitallatsnI tiK ylppuS rewoPkniL kniLtramS
Loading...