Response Mk2 DIN Rail GatewaysETC
Gateway Series
GENERAL INFORMATION
ETC’s Response Mk2 Four-Port Gateway provides data distribution using the quality and reliability of ETC’s network technology. Built for Net3 using industry-standard sACN, DMX and RDM, the Response Gateway unlocks the power of your networked system.
• Road houses
• Touring
• University/professional theaters
• Convention halls
• Tech tables
• Stage manager panels
• System integration
FEATURES
• Distributes DMX and RDM data to any input/output device over Ethernet
• Available in three different port counts
• Supports Net3 protocol powered by ACN
• Configurable DMX/RDM Output or Input
• Simple configuration and service of each port
• Onboard screen and buttons for labeling, status and configuration
• Power, network and port direction status indicators
• Touch to Wake Sensor
• Power over Ethernet (PoE) or external DC power supply
• Configurable using Concert Software
ORDERING INFORMATION
DIN Rail Gateways
MODEL DESCRIPTION
RSN-DMX1-DIN Response MK2 1-port Gateway - DIN Rail
RSN-DMX2-DIN Response MK2 2-port Gateway - DIN Rail
RSN-DMX4-DIN Response MK2 4-port Gateway - DIN Rail
Mounting Accessories
MODEL DESCRIPTION
DIN-RM DIN rail Rack Mount Kit
DIN14 Small DIN rail Enclosure - Vertical
DIN14-H Small DIN rail Enclosure - Horizontal
DIN28 Large DIN rail Enclosure
1 of 4
Page 2
Response Mk2 DIN Rail GatewaysETC
Gateway Series
SPECIFICATIONS
FUNCTIONAL
• Supports Net3/ACN (ANSI E1.31 and E1.17)
• Supports RDM (ANSI E1.20)
• Supports USITT DMX512-A (ANSI E1.11)
• USITT DMX512 and ANSI E1.11 DMX512-A compliant
• Flexible Output Patch allows a 512-address universe to begin at any output address
• Advanced Input Patch
• Support for per-address- or per-universe-level priority
• Maximum delay time from input to output not greater than one packet time
• Selectable DMX refresh rate with a maximum at least 40Hz
• Supports up to 256 total RDM devices
MECHANICAL
• Intuitive four-button interface
• Onboard display for identification, status and configuration
• Molded plastic enclosure
• Mounting complies with DIN43880 (35/7.5 rail)
• DIN installation enclosure available
• Network, power and data activity LED indicators
- Blue power indicator, green network activity indicator
- Bi-color DMX activity indicator
• RJ45 for connection to lighting network
• Reset button for hard reset or forced reboot
ENVIRONMENTAL
• Ambient operating temperature: 0° to 40°C (32° to 104°F)
• Operating humidity: 5% - 95% non-condensing
• Storage temperature: -40° to 70°C (-40° to 158°F)
ELECTRICAL
• Compliant with IEEE 802.3i for 10BASE-T, 802.3u for 100BASE-TX and 802.3af for Power over Ethernet
• 12-24VDC power input for use with non-PoE systems
• Maximum seven watt current draw
CONFIGURATION
• Local configuration options
• Remote configuration provided by Net3 Concert
- Supports up to 512 DMX addresses per port
- Supports up to 63,999 Streaming ACN universes
• DMX data input or output configurable by user
• Multiple sources may be combined to the network with each source or address allowed an independent priority
• Individual port start address and offset
• User-configurable labeling
REGULATORY AND COMPLIANCE
• cETLus Listed
• CE compliant
• EAC certified
• RoHS compliant
• WEEE
ADDITIONAL INFORMATION
DMX512
Often shortened to DMX (Digital Multiplex), this communication protocol is used mainly to control dimmers and multi-parameter fixtures. A universe of DMX is defined as 512 channels. DMX sends a nearly continuous stream of level information for each control channel. It is a form of RS-485 digital serial communication.
RDM
Remote Device Management (ANSI E1.20) is a protocol enhancement to DMX512 that allows low-speed bidirectional communication between a system controller and attached RDM devices over a standard DMX line. This protocol will allow remote configuration, status monitoring, and management of devices.
sACN
Streaming ACN (ANSI E1.31), sends DMX-style control over TCP/ IP networks. It provides a fast and efficient mechanism to transport the well-understood DMX protocol over Ethernet using an industry­standard protocol.
ACN
Architecture for Control Networks (ANSI E1.17) is a standard for high-speed bidirectional communication over TCP/IP on Ethernet network infrastructure. ACN is an open suite of protocols used between network devices for the purposes of greater and more adaptive control.
NET3
ETC’s enhanced implementation of the standard ACN Protocol Suite (ANSI E1.17 and E1.31) including additional communication protocols for specialized applications and support of legacy systems.
2 of 4
Page 3
TYPICAL SYSTEM RISER
1 3 5 7
2 4 6 8
910111213 15 17 19
14 16 18 2021222324
LNK /ACT
G1 G2
LNK /ACT
LNK /ACT
PoE
MASTER
1 23 4
5 67 8
STACK ID
PWREPSDIAG
TEMPFAN
LNK/ACT FDX/HDX
G3 G4
STACKING PORT
SELECT
RESET
Paradigm Touchscreen
P-TS7
Ethernet Switch
Paradigm ERn2
Sensor3
Power Control Rack
Ethernet
Ethernet
Ethernet
Response
4-Port Gateway
Eos Ti Console
Source Four LED
Series 2
Ethernet
etcconnect.com
Power
Network
TM
Mk2 DMX Gateway
serial number
3060167
Intertek
USC
Model RSN-DMX4-DIN
TM
Network
Power
etcconnect.com
Mk2 DMX Gateway
3060167
Intertek
USC
Response
4-Port DIN Gateway
PUSH
DMX OUTPUT
DMX
DMX Plug-in Station
ETCNet
PUSH
Ethernet Cable
DMX Cable
DMX Cable
Response Mk2 DIN Rail GatewaysETC
Gateway Series
3 of 4
Page 4
PHYSICAL
UNLESS OTHERWISE SPECIFIED
PO Box 620979 Middleton WI 53562-0979
etcconnect.com
Fax +1 608 836 1736
Toll Free +1 800 688 4116
Tel +1 608 831 4116
3031 Pleasant View Rd
ETC, Inc.
ALL DIMENSIONS ARE IN INCHES.
REPRESENTATIVE:
APPLICATIONS ENGINEER:
DATE
PROJECT MANAGER:
ORIGINAL FILE:
BY REV.
LOCATION:
DRAWING TITLE:
CONTRACT WITH:
JOB:
JOB NUMBER:
Response Mk2 DIN Rail GatewaysETC
Gateway Series
Response DIN Rail Gateway Dimensions
MODEL HEIGHT WIDTH DEPTH
in mm in mm in mm
RSN-DMX-DIN 3.53 90 6.36 162 2.39 61
Response DIN Rail Gateways
Power
Network
Intertek
USC
3060167
Mk2 DMX Gateway
TM
Model
RSN-DMX4-DIN RSN-DMX2-DIN RSN-DMX1-DIN
Response DIN Rail Gateways Weights
MODEL WEIGHT SHIPPING WEIGHT
lb kg lb kg
RSN-DMX*-DIN 0.56 0.25 2.00 0.91
etcconnect.com
Model RSN-DMX4-DIN RSN-DMX2-DIN RSN-DMX1-DIN
Model RSN-DMX4-DIN RSN-DMX2-DIN RSN-DMX1-DIN
etcconnect.com
etcconnect.com
Intertek
Intertek
Power
Network
USC
3060167
3060167
USC
Power
Network
Mk2 DMX Gateway
Mk2 DMX Gateway
TM
TM
Corporate Headquarters l Middleton, WI USA Global Offices l London, UK l Rome, IT l Holzkirchen, DE l Paris, FR l Hong Kong l Singapore l New York, NY l Orlando, FL l Los Angeles, CA
Copyright©2019 ETC. All Rights Reserved. All product information and specifications subject to change. Rev A 10/19
Trademark and patent info: etcconnect.com/IP
etcconnect.com
4 of 4
Loading...